Search NASA⌕ Search

SEARCH · Search NASA

Results for “activation volume”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

UCGretina geant4 simulation of the GRETINA Gamma-Ray Energy Tracking Array

UCGretina, a geant4 simulation of the GRETINA gamma-ray tracking array of highly-segmented high-purity germanium detectors is described. We have developed a model of the array, in particular of the Quad Module and the capsules, that gives good agreement between simulated and measured photopeak efficiencies over a broad range of gamma-ray energies and reproduces the shape of the measured Compton continuum. Both of these features are needed in order to accurately extract gamma-ray yields from spectra collected in in-beam gamma-ray spectroscopy measurements with beams traveling at v / c ≳0.3 at the National Superconducting Cyclotron Laboratory and the Facility for Rare Isotope Beams. In the process of developing the model, we determined that millimeter-scale layers of passive germanium surrounding the active volumes of the simulated crystals must be included in order to reproduce measured photopeak efficiencies. In conclusion, we adopted a simple model of effective passive layers and developed heuristic methods of determining passive-layer thicknesses by comparison of simulations and measurements for a single crystal and for the full array. Prospects for future development of the model are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First experimental measurements with the Segmented Inverted-coaxial GerMAnium (SIGMA) detector

The SIGMA project aims to develop a p-type segmented inverted coaxial point contact germanium detector for gamma-ray tracking and imaging. Here the performance of the first prototype of this type of detector is reported. The measurements performed verified the size and shape of the crystal and determined the location of the complex active volumes of the detector segments. The latter determines the charge collection times that are related to the position of interaction. Good agreement is found between the results and the specified crystal design. The energy resolution of the point contact has been measured to be 0.84 keV and 2.21 keV at 122 keV and 1332 keV, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A virtual Frisch-grid geometry-based CZT gamma detector for in-field radioisotope identification

Here, we present a Virtual Frisch-Grid geometry-based CZT gamma detector developed for identifying different radioisotopes over an energy range from a few keV up to 2 MeV, and useful for efficient characterization of CZT crystals. The detector is built with a 3 x 3 matrix of CZT crystals, each measuring approximately 6 mm x 6 mm x 15 mm. The charge generated within the sensor’s active volume is read out via an anode connected directly to the AVG3_Dev integrated circuit. A current signal induced by charge drift is collected on side pads of the crystals, enabling reconstruction of a 3D interaction position. This paper discusses the design, development, and performance of the standalone, mobile detector system, which integrates the AVG3_Dev readout IC developed at Brookhaven National Laboratory, a high-speed FPGA-based with per-channel digital signal processing, and embedded system capabilities. The device is compact, battery-powered, and supports wireless data streaming, making it suitable for field operations for radioisotope identification.

47 OTHER INSTRUMENTATION↗

High-pressure neutron powder diffraction study of an arsenolite deuterium inclusion compound: structure and formation kinetics

High-pressure variable-temperature neutron powder diffraction was employed to investigate the synthesis and structural properties of arsenolite (As 4 O 6 ), a cubic arsenic( III ) oxide polymorph, and its inclusion compound with deuterium. The compound forms with the stoichiometry As 4 O 6 ·2D 2 , consistent with earlier findings. At 295 K and 1.96(2) GPa, D 2 molecules occupy the 16c site (0, 0, 0) and are aligned along the <111> direction. The diffraction data suggest that the D 2 molecules at this site become rotationally disordered upon decompression to 0.78(2) GPa at 120 K, while no occupancy is observed at the 8a position (⅛, ⅛, ⅛) under any of the studied conditions. The kinetic data of the high-pressure inclusion compound synthesis at 1.56(2) and 1.96(2) GPa were analyzed using the Avrami model. The Avrami exponent, 0.135(16), remains invariant with pressure, demonstrating that the reaction topochemistry is unaffected by compression. Similarly, the reaction rates, 0.29(3) and 0.23(3) min −0.135 at 1.56(2) and 1.96(2) GPa, respectively, exhibit negligible pressure dependence and suggest a surprisingly low activation volume of 1.6 cm 3 mol −1 for the reaction. These results provide detailed insight into the structural dynamics and kinetics of deuterium inclusion in arsenolite under high pressure.

Guńka, Piotr A. [Warsaw University of Technology (↗

Progress toward absolute calibrations of DC x-ray sources from 1 keV to >30 keV for Z diagnostics applications

Numerous x-ray diagnostics at the Z facility, time-resolved and time-integrated, would benefit from a local calibrated x-ray source. For many years, Z has used low-power Manson x-ray sources to provide some characterization information for components of Z diagnostics below 30 keV. More recently, we have acquired TruFocus x-ray sources, which operate at voltages up to 100 kV depending on the anode material and model. These DC sources have demonstrated good stability and repeatability. Absolute calibrations of either sources or detectors usually involve another calibrated detector from another source, which has not been readily available locally. Therefore, we have adopted the strategy of characterizing a sensitive semiconductor diode detector by controlling or inferring the active volume. This characterized detector is then used to scale the Manson x-ray spectral shape as measured by an Amptek energy-resolving detector. Here, the result agrees well with the modeled source spectrum. We can apply this technique to the TruFocus as well.

Crystal spectroscopy↗

Effects of confinement and pressure on the structure and dynamics of carbon dioxide in silica slit pores

An understanding of carbon dioxide fluid properties within geological mesopores is important in applications ranging from carbon sequestration to shale oil recovery. Here, a molecular dynamics study is presented that aims to shed light on these systems by simulation of CO 2 fluid confined in β-cristobalite silica slit pores with different pore widths and pressure conditions. The weakly associating nature of carbon dioxide leads to little difference in structural and interfacial dynamical properties for different pore sizes and pressures. Rather, the behavior is found to be dominated by the entropic effects, namely, how the CO 2 organizes next to the silica surface. The CO 2 self-diffusion coefficient shows the strongest pore size dependence. It is strongly diminished in small pores and does not reach the bulk fluid value even in 6 nm pores. It also decreases with pressure, yielding an activation volume that increases with pore size. These results provide new insight into the behavior of a compressible fluid in nanoscale confinement.

Godahewa, Sahan M. [Univ. of Kansas, Lawrence, KS ↗

First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform

The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of 7.2× 6.1× 7.0 m3. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV/c to 7 GeV/c. Beam line instrumentation provides accurate momentum measurements and particle identification. The ProtoDUNE-SP detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment, and it incorporates full-size components as designed for that module. This paper describes the beam line, the time projection chamber, the photon detectors, the cosmic-ray tagger, the signal processing and particle reconstruction. It presents the first results on ProtoDUNE-SP's performance, including noise and gain measurements, dE/dx calibration for muons, protons, pions and electrons, drift electron lifetime measurements, and photon detector noise, signal sensitivity and time resolution measurements. The measured values meet or exceed the specifications for the DUNE far detector, in several cases by large margins. ProtoDUNE-SP's successful operation starting in 2018 and its production of large samples of high-quality data demonstrate the effectiveness of the single-phase far detector design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the longitudinal diffusion of ionization electrons in the MicroBooNE detector

Accurate knowledge of electron transport properties is vital to understanding the information provided by liquid argon time projection chambers (LArTPCs). Ionization electron drift-lifetime, local electric field distortions caused by positive ion accumulation, and electron diffusion can all significantly impact the measured signal waveforms. This paper presents a measurement of the effective longitudinal electron diffusion coefficient, D L , in MicroBooNE at the nominal electric field strength of 273.9 V/cm. Historically, this measurement has been made in LArTPC prototype detectors. This represents the first measurement in a large-scale (85 tonne active volume) LArTPC operating in a neutrino beam. This is the largest dataset ever used for this measurement. Using a sample of ~70,000 through-going cosmic ray muon tracks tagged with MicroBooNE's cosmic ray tagger system, we measure D L = 3.74 +0.28 -0.29 cm 2 /s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response of AC-coupled low gain avalanche detectors to ionizing and non-ionizing radiation damage

Low gain avalanche diodes with DC- and AC-coupled readout were exposed to ionizing and non-ionizing radiation at levels relevant to future experiments in particle, nuclear, and medical physics and to astrophysics. Damage-related change in their acceptor removal constants and in the resistivity of the region between the guard ring and the active area are reported, as is change in the leakage current and depletion voltages of the active volumes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uniaxial tensile mechanical properties from a scratch on ultra-fine grained tungsten

We demonstrate that surface-based mechanical testing can be used to quantify a wide range of mechanical properties determined using traditional uniaxial tension experiments. These include mapping of dynamic stress–strain behaviour, which can be used as a screening tool for uniaxial tensile ductility (uniform elongation), fracture toughness (K C ), which is shown to be in good agreement with reported plane-strain K IC , as well work-hardening exponents (n), activation volumes (V) energies (Q) and strain-rate sensitivity (m) exponents as a function of temperature. Advantages of the surface-based approach are the ability to work with significantly smaller volumes and accommodate processing defects like pores, voids and cracks. These methods are applied to ultra-fine grained tungsten (average grain size of 650 nm), as it is an ideal candidate for alloy development efforts in advanced energy systems. Tungsten is a useful baseline as it exhibits a near-ambient temperature (approx. 200°C) ductile-to-brittle transition temperature (DBTT), enabling validation efforts for the proposed methods, and extraordinary material properties, including the highest melting temperature of any metal and complex temperature and strain-rate dependencies linked to transitions in dislocation mechanisms.

36 MATERIALS SCIENCE↗

Vapor-Cell-Based Atomic Electrometry for Detection Frequencies below 1 kHz

Rydberg-assisted atomic electrometry using alkali-metal atoms contained inside a vacuum environment for detecting external electric fields at frequencies below a few kilohertz has been quite challenging due to the low-frequency electric-field-screening effect that is caused by the alkali-metal atoms adsorbed on the inner surface of the container. In this work, we report a very slow electric-field-screening phenomenon with a timescale up to the order of seconds on a rubidium-vapor cell that is made of monocrystalline sapphire. Furthermore, using this sapphire rubidium-vapor cell with an optically induced, internal bias electric field, we demonstrate vapor-cell-based, low-frequency atomic electrometry that responds to the electric field strength linearly. Limited by the given experimental conditions, this demonstrated atomic electrometer uses an active volume of 11 mm 3 and delivers a spectral noise floor of around 0.34 mV/m √Hz and a 3-dB low cutoff frequency of around 770 Hz inside the vapor cell. This work investigates a regime of vapor-cell-basedatomic electrometry that was seldom studied before, which may enable more applications that use atomicelectric-field-sensing technology.

74 ATOMIC AND MOLECULAR PHYSICS↗

Projected sensitivity of the LUX-ZEPLIN experiment to the $0\nu\beta\beta$ decay of $^{136}Xe$

The LUX-ZEPLIN (LZ) experiment will enable a neutrinoless double β decay search in parallel to the main science goal of discovering dark matter particle interactions. We report the expected LZ sensitivity to Xe136 neutrinoless double β decay, taking advantage of the significant (>600 kg) Xe136 mass contained within the active volume of LZ without isotopic enrichment. After 1000 live-days, the median exclusion sensitivity to the half-life of Xe136 is projected to be 1.06×1026 years (90% confidence level), similar to existing constraints. We also report the expected sensitivity of a possible subsequent dedicated exposure using 90% enrichment with Xe136 at 1.06×1027 years.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Measurement of Discrimination between Helium and Electron Recoils in Liquid Xenon for Low-Mass Dark Matter Searches

We report the first measurement of discrimination between low-energy helium recoils and electron recoils in liquid xenon. This result is relevant to proposed low-mass dark matter searches which seek to dissolve light target nuclei in the active volume of liquid-xenon time projection chambers. Low-energy helium recoils were produced by degrading α particles from Po 210 with a gold foil situated on the cathode of a liquid xenon time-projection chamber. The resulting population of helium recoil events is well separated from electron recoils and is also offset from the expected position of xenon nuclear recoil events. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above 1.4×10 –48 cm 2 for a WIMP mass of 40GeV/c 2 and a 1000 days exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and bespoke detector systems to assay scintillator are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Erratum to: The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above 1.4 × 10 -48 cm 2 for a WIMP mass of 40 GeV/c 2 and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and be spoke detector systems to assay scintillator are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First results of the NEXT-100 detector using $^{83m}$Kr decays

The NEXT collaboration is investigating the double beta decay of $ ^{136}\mathrm Xe$ using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterráneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from $^{83\text {m}}\textrm{Kr}$ decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for $^{83\text {m}}\textrm{Kr}$ point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an $E^{-1/2}$ extrapolation to $Q_{\beta \beta }$ yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target.

Martínez-Lema, G. [Donostia Intl. Phys. Ctr., San ↗

Structure-Property Relationships of Additively Manufactured Ni-Nb Alloys [Slides]

In this work, scratch and nanoindentation testing was used to determine hardness, fracture toughness, strain rate sensitivity, and activation volumes on additively manufactured graded and uniform Ni-Nb bulk specimens. Characterization showed the presence of a two phase system consisting of Ni 3 Nb and Ni 6 Nb 7 intermetallics. Intermetallics were multimodal in nature, having grain and cell sizes spanning from a few nanometers to 10s of micrometers. The unique microstructure resulted in impressively high hardness, up to 20 GPa in the case of the compositionally graded sample. AM methods with surface deformation techniques are a useful way to rapidly probe material properties and alloy composition space.

36 MATERIALS SCIENCE↗

Structure-Property Relationships of Additively Manufactured Ni-Nb Alloys [Slides]

In this work, scratch and nanoindentation testing was used to determine hardness, fracture toughness, strain rate sensitivity, and activation volumes on additively manufactured graded and uniform Ni-Nb bulk specimens. Characterization showed the presence of a two phase system consisting of Ni 3 Nb and Ni 6 Nb 7 intermetallics. Intermetallics were multimodal in nature, having grain and cell sizes spanning from a few nanometers to 10s of micrometers. The unique microstructure resulted in impressively high hardness, up to 20 GPa in the case of the compositionally graded sample. AM methods with surface deformation techniques are a useful way to rapidly probe material properties and alloy composition space.

36 MATERIALS SCIENCE↗