Search NASA⌕ Search

SEARCH · Search NASA

Results for “active pixel sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The INFN R&D: New pixel detector for the High Luminosity upgrade of the LHC

The High Luminosity upgrade of the CERN-LHC (HL-LHC) demands for a new high-radiation tolerant solid-state pixel sensor capable of surviving fluencies up to a few 10 16 particles/cm 2 at ~3 cm from the interaction point. To this extent the INFN ATLAS-CMS joint research activity, in collaboration with Fondazione Bruno Kessler-FBK, is aiming at the development of thin n-in-p type pixel sensors for the HL-LHC. The R&D covers both planar and single-sided 3D columnar pixel devices made with the Si-Si Direct Wafer Bonding technique, which allows for the production of sensors with 100 μm and 130 μm active thickness for planar sensors, and 130 μm for 3D sensors, the thinnest ones ever produced so far. The first prototypes of hybrid modules bump-bonded to the present CMS and ATLAS readout chips have been tested in beam tests. Furthermore, the preliminary results on their performance before and after irradiation are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pixel Detector Developments for Tracker Upgrades of the High Luminosity LHC

This paper reports on the INFN (Istituto Nazionale di Fisica Nucleare, Italy) research activity in collaboration with FBK foundry, which is aiming at the development of new pixel detectors for the LHC Phase-2 upgrades. The R&D covers both planar pixel devices and 3D detectors built using columnar technology. All sensors are low thickness n-in-p type, as this is the general direction envisaged for the High Luminosity LHC pixel detector upgrades. Hybrid modules with 100 $\upmu $ m and 130 $\upmu $ m active thickness, connected to the PSI46dig readout chip, have been tested on beam test experiments. Selected preliminary results from test beams are described for both planar and 3D devices. The results on the 3D pixel sensors before irradiation are very satisfactory and support the conclusion that columnar devices are very good candidates for the inner layers of the upgrade pixel detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unobtrusive Sensor-Based Occupancy Facing Direction Detection and Tracking Using Advanced Machine Learning Algorithms

Facing direction detection plays a critical role in human-computer interaction and has a wide application in surveillance systems, driving awareness recognition, smart home appliances, computer games, and so on. Current detection methods are mainly focused on extracting specific patterns from user's optical images, which raises concerns on privacy invasion and these detection techniques do not usually work in a dark environment. To address these concerns, here this paper proposes an activity recognition system guided by an unobtrusive sensor (ARGUS). By using a low pixel infrared thermopile array sensor, ARGUS is capable of identifying five facing directions (left 45°/90°, right 45°/90°, and front) through the support vector machine classifier. Also two feature extraction methods are compared. One is manually-defined and the other is based on a pre-trained convolutional neural network (CNN) model. The facing direction detection accuracy resulting from manually-defined features reaches 85.3%, 90.6%, and 85.2% at detection distance of 0.6, 1.2, and 1.8 m, respectively. The level of accuracy resulted from using pre-trained CNN features demonstrates a much more reliable performance (89.1%, 95.3%, and 95.1% at distance of 0.6, 1.2, and 1.8 m, respectively). In addition, ARGUS has been successfully applied for occupancy tracking with a root mean square error of 0.19 m.

42 ENGINEERING↗

Readout IC requirement trends based on a simplified parametric seeker model.

Modern space based optical sensors place substantial demands on the focal plane array readout integrated circuit. Active pixel readout designs offer direct access to individual pixel data but require analog to digital conversion at or near each pixel. Thus, circuit designers must create precise, fundamentally analog circuitry within tightly constrained areas on the integrated circuit. Rapidly changing phenomena necessitate tradeoffs between sampling and conversion speed, data precision, and heat generation adjacent the detector array, especially of concern for thermally sensitive space grade infrared detectors. A simplified parametric model is presented that illustrates seeker system performance and analog to digital conversion requirements trends in the visible through mid-wave infrared, for varying sample rate. Notional limiting-case Earth optical backgrounds were generated using MODTRAN4 with a range of cloud extremes and approximate practical albedo limits for typical surface features from a composite of the Mosart and Aster spectral albedo databases. The dynamic range requirements imposed by these background spectra are discussed in the context of optical band selection and readout design impacts.

47 OTHER INSTRUMENTATION↗

Laboratory and testbeam results for thin and epitaxial planar sensors for HL-LHC

The High-Luminosity LHC (HL-LHC) upgrade of the CMS pixel detector will require the development of novel pixel sensors which can withstand the increase in instantaneous luminosity to L = 5 × 10 34 cm –2 s –1 and collect ~ 3000fb –1 of data. The innermost layer of the pixel detector will be exposed to doses of about 10 16 n eq / cm 2 . Hence, new pixel sensors with improved radiation hardness need to be investigated. A variety of silicon materials (Float-zone, Magnetic Czochralski and Epitaxially grown silicon), with thicknesses from 50 μm to 320 μm in p-type and n-type substrates have been fabricated using single-sided processing. The effect of reducing the sensor active thickness to improve radiation hardness by using various techniques (deep diffusion, wafer thinning, or growing epitaxial silicon on a handle wafer) has been studied. Furthermore, the results for electrical characterization, charge collection efficiency, and position resolution of various n-on-p pixel sensors with different substrates and different pixel geometries (different bias dot gaps and pixel implant sizes) will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying Operational Drivers of Multimodal Biometric Verification in Aerial Surveillance

Multimodal biometric verification is increasingly applied across operational contexts ranging from close-range security cameras and building-mounted surveillance to long-range ground sensors and unmanned aerial system (UAS) imagery. Variations in acquisition conditions—such as image resolution, viewing geometry, and motion artifacts—pose significant challenges for cross-domain algorithmic generalization. This study evaluates two independent multimodal biometric verification systems developed under the Intelligence Advanced Research Projects Activity (IARPA) Biometric Recognition and Identification at Altitude and Range (BRIAR) program, comparing performance on close-range and aerial datasets. Close-range video served as a baseline to quantify the decline in verification performance on aerial footage. The dataset included six UAS platforms, spanning small quadcopters at 10m altitude to medium-sized fixed-wing aircraft at 360m. Mixed-effects logistic regression identified image resolution (head and body pixel counts), head height, sensor characteristics, and algorithm selection as primary determinants of verification success, whereas demographic attributes and mission gait were not significant predictors. Activity type and collection site influenced performance in close-range data but had negligible impact on UAS imagery. These results clarify modality-specific strengths and limitations and highlight opportunities to enhance cross-domain biometric verification.

Peluso, Alina [ORNL] (ORCID:0000000328950406)↗

SU-D-213-03: Towards An Optimized 3D Scintillation Dosimetry Tool for Quality Assurance of Dynamic Radiotherapy Techniques

Purpose: The purpose of this work is to simulate a multi-focus plenoptic camera used as the measuring device in a real-time three-dimensional scintillation dosimeter. Simulating and optimizing this realistic optical system will bridge the technological gap between concept validation and a clinically viable tool that can provide highly efficient, accurate and precise measurements for dynamic radiotherapy techniques. Methods: The experimental prototype, previously developed for proof of concept purposes, uses an off-the-shelf multi-focus plenoptic camera. With an array of interleaved microlenses of different focal lengths, this camera records spatial and angular information of light emitted by a plastic scintillator volume. The three distinct microlens focal lengths were determined experimentally for use as baseline parameters by measuring image-to-object magnification for different distances in object space. A simulated plenoptic system was implemented using the non-sequential ray tracing software Zemax: this tool allows complete simulation of multiple optical paths by modeling interactions at interfaces such as scatter, diffraction, reflection and refraction. The active sensor was modeled based on the camera manufacturer specifications by a 2048×2048, 5 µm-pixel pitch sensor. Planar light sources, simulating the plastic scintillator volume, were employed for ray tracing simulations. Results: The microlens focal lengths were determined to be 384, 327 and 290 µm. A realistic multi-focus plenoptic system, with independently defined and optimizable specifications, was fully simulated. A f/2.9 and 54 mm-focal length Double Gauss objective was modeled as the system’s main lens. A three-focal length hexagonal microlens array of 250-µm thickness was designed, acting as an image-relay system between the main lens and sensor. Conclusion: Simulation of a fully modeled multi-focus plenoptic camera enables the decoupled optimization of the main lens and microlens specifications. This work leads the way to improving the 3D dosimeter’s achievable resolution, efficiency and build for providing a quality assurance tool fully meeting clinical needs. M.R. is financially supported by a Master’s Canada Graduate Scholarship from the NSERC. This research is also supported by the NSERC Industrial Research Chair in Optical Design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterisation of the high dynamic range Large Pixel Detector (LPD) and its use at X-ray free electron laser sources

The STFC Rutherford Appleton Laboratory have delivered the Large Pixel Detector (LPD) for MHz frame rate imaging at the European XFEL. The detector system has an active area of 0.5 m × 0.5 m and consists of a million pixels on a 500 μm pitch. Sensors have been produced from 500 μm thick Hammamatsu silicon tiles that have been bump bonded to the readout ASIC using a silver epoxy and gold stud technique. Each pixel of the detector system is capable of measuring 10 5 12 keV photons per image readout at 4.5 MHz. In this paper results from the testing of these detectors at the Diamond Light Source and the Linac Coherent Light Source (LCLS) are presented. As a result, the performance of the detector in terms of linearity, spatial uniformity and the performance of the different ASIC gain stages is characterised.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of uniformity of 50 μ m low-gain avalanche detectors at the Fermilab test beam

In this study, we report measurements of the uniformity of time resolution, signal amplitude, and charged particle detection efficiency across the sensor surface of low-gain avalanche detectors (LGAD). Comparisons of the performance of sensors with different doping concentrations and different active thicknesses are presented, as well as their temperature dependence and radiation tolerance up to 6 x 10 14 n/cm 2 . Results were obtained at the Fermilab test beam facility using 120 GeV proton beams, and a high precision pixel tracking detector. LGAD sensors manufactured by the Centro Nacional de Microelectrónica (CNM) and Hamamatsu Photonics (HPK) were studied. The uniformity of the sensor response in pulse height before irradiation was found to have a 2% spread. The signal detection efficiency and timing resolution in the sensitive areas before irradiation were found to be 100% and 30–40 ps, respectively. A “no-response” area between pads was measured to be about 130 μm for CNM and 170μm for HPK sensors. After a neutron fluence of 6 x 10 14 n/cm 2 the CNM sensor exhibits a large gain variation of up to a factor of 2.5 when comparing metalized and non-metalized sensor areas. An irradiated CNM sensor achieved a time resolution of 30 ps for the metalized area and 40 ps for the non-metalized area, while a HPK sensor irradiated to the same fluence achieved a 30 ps time resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multipurpose Compact Spectrometric Unit

A new standalone compact spectrometer was developed. The device consists of analog (peamplifier, amplifier) and digital parts. The digital part is based on the 160 MIPS Digital Signal Processor. It contains 20 Msps Flash-ADC, 1 MB RAM for spectra storage, 128 KB Flash/ROM for firmware storage, Real Time Clock and several voltage regulators providing the power for user peripherals (e.g. amplifier, temperature sensors, etc.). Spectrometer is connected with a notebook via high-speed USB 2.0 bus. The spectrometer is multipurpose device, which is planned to be used for measurements of Rn activities, energy of detected particles by CdTe pixel detector or for coincidence measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Readout optimization of multi-amplifier sensing charge-coupled devices for single-quantum measurement

The non-destructive readout capability of the Skipper Charge Coupled Device (CCD) has been demonstrated to reduce the noise limitation of conventional silicon devices to levels that allow single-photon or single-electron counting. The noise reduction is achieved by taking multiple measurements of the charge in each pixel. These multiple measurements come at the cost of extra readout time, which has been a limitation for the broader adoption of this technology in particle physics, quantum imaging, and astronomy applications. This work presents recent results of a novel sensor architecture that uses multiple non-destructive floating-gate amplifiers in series to achieve sub-electron readout noise in a thick, fully-depleted silicon detector to overcome the readout time overhead of the Skipper-CCD. This sensor is called the Multiple-Amplifier Sensing Charge-Coupled Device (MAS-CCD) can perform multiple independent charge measurements with each amplifier, and the measurements from multiple amplifiers can be combined to further reduce the readout noise. We will show results obtained for sensors with 8 and 16 amplifiers per readout stage in new readout operations modes to optimize its readout speed. The noise reduction capability of the new techniques will be demonstrated in terms of its ability to reduce the noise by combining the information from the different amplifiers, and to resolve signals in the order of a single photon per pixel. The first readout operation explored here avoids the extra readout time needed in the MAS-CCD to read a line of the sensor associated with the extra extent of the serial register. The second technique explore the capability of the MAS-CCD device to perform a region of interest readout increasing the number of multiple samples per amplifier in a targeted region of the active area of the device.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tracking Efficiency And Charge Sharing of 3D Silicon Sensors at Different Angles in a 1.4T Magnetic Field

A 3D silicon sensor fabricated at Stanford with electrodes penetrating throughout the entire silicon wafer and with active edges was tested in a 1.4 T magnetic field with a 180 GeV/c pion beam at the CERN SPS in May 2009. The device under test was bump-bonded to the ATLAS pixel FE-I3 readout electronics chip. Three readout electrodes were used to cover the 400 {micro}m long pixel side, this resulting in a p-n inter-electrode distance of {approx} 71 {micro}m. Its behavior was confronted with a planar sensor of the type presently installed in the ATLAS inner tracker. Time over threshold, charge sharing and tracking efficiency data were collected at zero and 15{sup o} angles with and without magnetic field. The latest is the angular configuration expected for the modules of the Insertable B-Layer (IBL) currently under study for the LHC phase 1 upgrade expected in 2014.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Module and electronics developments for the ATLAS ITk pixel system

The ATLAS experiment is preparing for an extensive modification of its detectors in the course of the planned HL-LHC accelerator upgrade around 2025. The ATLAS upgrade includes the replacement of the entire tracking system by an all-silicon detector (Inner Tracker, ITk). The five innermost layers of ITk will be a pixel detector built of new sensor and readout electronics technologies to improve the tracking performance and cope with the severe HL-LHC environment in terms of occupancy and radiation. Here, the total area of the new pixel system could measure up to 14 m 2 , depending on the final layout choice, which is expected to take place in 2018. In this paper an overview of the ongoing R&D activities on modules and electronics for the ATLAS ITk is given including the main developments and achievements in silicon planar and 3D sensor technologies, readout and power challenges.

47 OTHER INSTRUMENTATION↗

THE ARCONS PIPELINE: DATA REDUCTION FOR MKID ARRAYS

The Array Camera for Optical to Near-IR Spectrophotometry, or ARCONS, is a camera based on Microwave Kinetic Inductance Detectors (MKIDs), a new technology that has the potential for broad application in astronomy. Using an array of MKIDs, the instrument is able to produce time-resolved imaging and low-resolution spectroscopy constructed from detections of individual photons. The arrival time and energy of each photon are recorded in a manner similar to X-ray calorimetry, but at higher photon fluxes. The technique works over a very large wavelength range, is free from fundamental read noise and dark-current limitations, and provides microsecond-level timing resolution. Since the instrument reads out all pixels continuously while exposing, there is no loss of active exposure time to readout. The technology requires a different approach to data reduction compared to conventional CCDs. Here we outline here the prototype data reduction pipeline developed for ARCONS, though many of the principles are also more broadly applicable to energy-resolved photon counting arrays (e.g., transition edge sensors, superconducting tunnel junctions). We describe the pipeline's current status, and the algorithms and techniques employed in taking data from the arrival of photons at the MKID array to the production of images, spectra, and time-resolved light curves.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards an improved LAI collection protocol via simulated field-based PAR sensing

In support of NASA’s next-generation spectrometer—the Hyperspectral Infrared Imager (HyspIRI)—we are working towards assessing sub-pixel vegetation structure from imaging spectroscopy data. Of particular interest is Leaf Area Index (LAI), which is an informative, yet notoriously challenging parameter to efficiently measure in situ. While photosynthetically-active radiation (PAR) sensors have been validated for measuring crop LAI, there is limited literature on the efficacy of PAR-based LAI measurement in the forest environment. This study (i) validates PAR-based LAI measurement in forest environments, and (ii) proposes a suitable collection protocol, which balances efficiency with measurement variation, e.g., due to sun flecks and various-sized canopy gaps. A synthetic PAR sensor model was developed in the Digital Imaging and Remote Sensing Image Generation (DIRSIG) model and used to validate LAI measurement based on first-principles and explicitly-known leaf geometry. Simulated collection parameters were adjusted to empirically identify optimal collection protocols. Furthermore, these collection protocols were then validated in the field by correlating PAR-based LAI measurement to the normalized difference vegetation index (NDVI) extracted from the “classic” Airborne Visible Infrared Imaging Spectrometer (AVIRIS-C) data (R 2 was 0.61). The results indicate that our proposed collecting protocol is suitable for measuring the LAI of sparse forest (LAI < 3–5 ( m 2 /m 2 )).

47 OTHER INSTRUMENTATION↗

Restrictions on Measurement of Roughness of Textile Fabrics by Laser Triangulation: A Phenomenological Approach

Laser triangulation method is one of the methods used for contactless measurement of roughness of textile fabrics. Method is based on measurement of distance between the sensor and the object by imaging the light scattered from the surface. However, experimental results, especially for high values of roughness, show a strong dependence to duration of exposure time to laser pulses. Use of very short exposure times and long exposures times causes appearance on the surface of the scanned textile of pixels with Active peak heights. The number of Active peaks increases with decrease of exposure time down to 0.1 ms, and increases with increase of exposure time up to 100 ms. Appearance of Active peaks leads to nonrealistic increase of roughness of the surface both for short exposure times and long exposure times reaching a minimum somewhere in the region of medium exposure times, 1 to 2 ms. The above effect suggests a careful analysis of experimental data and, also, becomes an important restriction to the method. In this paper we attempt to make a phenomenological approach to the mechanisms leading to these effects. We suppose that effect is related both to scattering properties of scanned surface and to physical parameters of CCD sensors. The first factor becomes more important in the region of long exposure times, while second factor becomes more important in the region of short exposure times.

36 MATERIALS SCIENCE↗

The X-ray Integral Field Unit at the end of the Athena reformulation phase

The Athena mission entered a redefinition phase in July 2022, driven by the imperative to reduce the mission cost at completion for the European Space Agency below an acceptable target, while maintaining the flagship nature of its science return. This notably called for a complete redesign of the X-ray Integral Field Unit (X-IFU) cryogenic architecture towards a simpler active cooling chain. Passive cooling via successive radiative panels at spacecraft level is now used to provide a 50 K thermal environment to an X-IFU owned cryostat. 4.5 K cooling is achieved via a single remote active cryocooler unit, while a multi-stage Adiabatic Demagnetization Refrigerator ensures heat lift down to the 50 mK required by the detectors. Amidst these changes, the core concept of the readout chain remains robust, employing Transition Edge Sensor microcalorimeters and a SQUID-based Time-Division Multiplexing scheme. Noteworthy is the introduction of a slower pixel. This enables an increase in the multiplexing factor (from 34 to 48) without compromising the instrument energy resolution, hence keeping significant system margins to the new 4 eV resolution requirement. This allows reducing the number of channels by more than a factor two, and thus the resource demands on the system, while keeping a 4’ field of view (compared to 5’ before). Here, in this article, we will give an overview of this new architecture, before detailing its anticipated performances. Finally, we will present the new X-IFU schedule, with its short term focus on demonstration activities towards a mission adoption in early 2027.

Peille, Philippe [Centre National d’Etudes Spatial↗

ETROC1: the first full chain precision timing prototype ASIC for CMS MTD endcap timing layer upgrade

We present the design and characterization of the first fullchain precision timing prototype ASIC, named ETL Readout Chipversion 1 (ETROC1) for the CMS MTD endcap timing layer (ETL)upgrade. The ETL utilizes Low Gain Avalanche Diode (LGAD) sensors todetect charged particles, with the goal to achieve a time resolutionof 40–50 ps per hit, and 30–40 ps per track with hits from twodetector layers. The ETROC1 is composed of a 5 × 5 pixelarray and peripheral circuits. The pixel array includes a4 × 4 active pixel array with an H-tree shaped networkdelivering clock and charge injection signals. Each active pixel iscomposed of various components, including a bump pad, a chargeinjection circuit, a pre-amplifier, a discriminator, adigital-to-analog converter, and a time-to-digital converter. Thesecomponents play essential roles as the front-end link in processingLGAD signals and measuring timing-related information. Theperipheral circuits provide clock signals and readoutfunctionalities. The size of the ETROC1 chip is7 mm× 9 mm. ETROC1 has been fabricated in a 65 nmCMOS process, and extensively tested under stimuli of chargeinjection, infrared laser, and proton beam. The time resolution ofbump-bonded ETROC1 + LGAD chipsets reaches 42–46 ps per hit in thebeam test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗