Search NASA⌕ Search

SEARCH · Search NASA

Results for “aerosol capture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Final Report on Aerosol Pretreatment Technology Performance and Benchmarking

Solvent-based post-combustion CO 2 capture (PCC) technology remains one of the leading methods to combat global CO 2 emissions produced from large-scale coal-fired power production. Advanced solventbased PCC technology has made significant improvements in design and performance that reduce capital and operating costs to enable its commercial use. Key to low cost, manageable logistics, and environmentally safe operation of solvent-based PCC technology are minimal solvent losses from the process through the treated gas stream exiting PCC plant absorbers. High flue gas aerosol particle concentrations (>10 5 particles/cm 3 ) for particles in the range of 70-200 nm have been shown to cause significant amine solvent losses for solvent-based PCC processes through several mechanisms including absorption of solvent and water into growing aerosol particles. Flue gas aerosol pretreatment technology is the only realistic and economically attractive method to reduce very high aerosol particle concentrations (>10 7 particles/cm 3 ) to enable solvent-based PCC for existing power plants lacking sufficient particle removal systems, such as baghouses. The overall goal of this project was to design, construct, independently test, and evaluate three flue gas aerosol pretreatment technologies identified to significantly reduce high aerosol particle concentrations (>10 7 particles/cm 3 ) in the 70-200 nm particle size range: (1) a novel, high-velocity water injection spray concept developed by RWE and tested by Linde, (2) an innovative electrostatic precipitator (ESP) device with optimized operating conditions developed by Washington University in St. Louis (WUSTL), and (3) a non-regenerative sorbent-based filter technology developed by InnoSepra for SO x and NO x removal from coal-fired power plant flue gas. Each technology has been validated with tests on 500-1000 scfm of actual coal-fired flue gas and evaluated in terms of particle removal efficiency (%), cost competitiveness, and environmental impact. Aerosol measurements were performed upstream and downstream of each aerosol reduction unit during independent testing of each technology using advanced instrumentation and analytical methods provided by WUSTL. To perform aerosol measurements, isokinetic probes were inserted into flanged pipes attached to the flue gas piping, and a small suction pump was used to sample gas containing aerosol particles. Aerosol particle number concentrations (# particles/cm 3 ) and size distributions were then measured using a scanning mobility particle sizer (SMPS, TSI Inc.) for very fine particles (<1,000 nm) and a particle counter manufactured by GRIMM for particles larger than 1,000 nm. This report summarizes the aerosol removal performance results from pilot scale testing of each technology. Performance results have been benchmarked against pre-defined targets and other flue gas aerosol pretreatment technologies with documented performance. Linde Gas North America LLC has been the prime contractor to DOE responsible for overall project management and provided the design for the high-velocity water spray-based aerosol removal technology based on a design concept developed by the German utility company RWE.

20 FOSSIL-FUELED POWER PLANTS↗

Comparison of Current and Future PM2.5 Air Quality in China Under CMIP6 and DPEC Emission Scenarios

The latest scenarios for the sixth Coupled Model Intercomparison Project (CMIP6) provide opportunities to explore future climate and air pollution mitigation pathways with socioeconomic features. However, to what extent inadequate consideration of region-specific policies in the CMIP6 scenarios would affect regional air quality projections is still not clear. Here, we simulated China’s future PM2.5 concentrations and compositions with local policy-based scenarios and the original CMIP6 datasets, for the first time estimating future air quality differences induced by the lack of local pollution control policies in the CMIP6 scenarios. We found that the CMIP6-driven projections overestimate major chemical aerosols by 10% – 70% in 2015 and fail to capture the rapid PM2.5 concentration decline during 2015–2019. Near-term differences further lead to 43% – 49% (5 – 9 µg/m3) PM2.5 overpredictions in 2050 in CMIP6 scenarios compared with policy-based mitigation scenarios. Our study demonstrates the indispensable influences of local policies on regional analyses and suggests that the research community should incorporate more region-specific information in future scenario designs.

Cheng, Jing↗

Simulation-aided characterization of a versatile water-based condensation particle counter for atmospheric airborne research

Capturing the vertical profiles and horizontal variations of atmospheric aerosols often requires accurate airborne measurements. With the advantage of avoiding health and safety concerns related to the use of butanol or other chemicals, water-based condensation particle counters have emerged to provide measurements under various environments. However, airborne deployments are relatively rare due to the lack of instrument characterization under reduced pressure at flight altitudes. This study investigates the performance of a commercial “versatile” water-based condensation particle counter (vWCPC, model 3789, TSI, Shoreview, MN, USA) under various ambient pressure conditions (500–920 hPa) with a wide range of particle total number concentrations (1500–70 000 cm -3 ). The effect of conditioner temperature on vWCPC 3789 performance at low pressure is examined through numerical simulation and laboratory experiments. We show that the default instrument temperature setting of 30 °C for the conditioner is not suitable for airborne measurement and that the optimal conditioner temperature for low-pressure operation is 27°. Under the optimal conditioner temperature (27°), the 7 nm cut-off size is also maintained. Additionally, we show that insufficient droplet growth becomes more significant under the low-pressure operation. The counting efficiency of the vWCPC 3789 can vary up to 20 % for particles of different chemical compositions (e.g., ammonium sulfate and sucrose particles). However, such variation is independent of pressure.

54 ENVIRONMENTAL SCIENCES↗

Size-resolved process understanding of stratospheric sulfate aerosol following the Pinatubo eruption

Stratospheric sulfate aerosol produced by volcanic eruptions plays important roles in atmospheric chemistry and the global radiative balance of the atmosphere. The simulation of stratospheric sulfate concentrations and optical properties is highly dependent on the chemistry scheme and microphysical treatment. In this work, we implemented a sophisticated gas-phase chemistry scheme (full chemistry, FC) and a 5-mode version of the Modal Aerosol Module with Prognostic Stratospheric Aerosol (MAM5-PSA) for the interactive treatment of stratospheric sulfate aerosol in the Department of Energy's Energy Exascale Earth System Model version 2 (E3SMv2) model to better simulate the chemistry-aerosol feedback following the Pinatubo eruption, and to compare it against a simulation using simplified chemistry (SC) and the default 4-mode version of the Modal Aerosol Module (MAM4). MAM5-PSA experiments were found to better capture the stratospheric sulfate burden from the eruption of the volcano to the end of 1992 as compared to the High-resolution Infrared Sounder (HIRS) observations, and the formation of sulfate in MAM5-PSA with FC (with an additional OH replenishment reaction) was significantly faster than in MAM4 with FC. Analyses of microphysical processes indicate that more sulfate aerosol mass was generated in total in FC experiments than in SC experiments. MAM5-PSA performs better than MAM4 in simulation of aerosol optical depth (AOD); AOD anomalies from the MAM5-PSA experiment have better agreement with observations. The simulated largest changes in global mean net radiative flux at the top of the atmosphere following the eruption were about −3 W m −2 in MAM5-PSA experiments and roughly −1.5 W m −2 in MAM4 experiments.

AEROSOL↗

Advancing Post-Combustion CO 2 Capture through Increased Mass Transfer and Lower Degradation

The over-arching goal of the proposed project is to develop three techniques to enable aqueous post-combustion CO 2 capture technologies to meet the DOE performance and cost targets of 90% CO 2 capture, 95% purity, at a cost of less than $30/tonne CO 2 captured. This will be accomplished by the development of materials and processes to increase mass transfer in the absorber and reduce the environmental impacts. While constantly working to reduce the cost of CO 2 capture via solvent development and process & heat integration, increasing CO 2 mass transfer through development of custom dynamic packing materials and tuning solvent physical properties may offer a route to increased solvent capacity, lower energy consumption and reduced aerosol formation. The environmental concerns that have been identified in amine-based CO 2 capture systems, nitrosamines specifically, are another critical element that will be addressed in this project. The specific objectives of the project were to: 1) conduct detailed studies to understand how solvent physical properties and aerosol formation are impacted by additives; 2) quantify the CO 2 mass transfer improvement from the dynamic polarity packing in the absorber and the additive-modified solvent using the existing UK bench-scale CO 2 capture unit; 3) quantify the energy consumption savings associated with enhanced mass transfer; 4) quantify the benefits of the UK’s electrochemical cell to decompose nitrosamines; and 5) collect the necessary information/data to conduct a high-level TEA assessment of the proposed technologies. The project involved the fabrication and installation of customized dynamic polarity packing and an investigation into the understanding of the impact of chemical additives on solvent properties to increase CO 2 mass transfer in the absorber column, and lastly the design of an electrochemical cell to decompose nitrosamines in a water wash. After both systems were fabricated, they were tested at UK facilities, including on the bench-scale CO 2 capture unit under parametric and long-term operation.

20 FOSSIL-FUELED POWER PLANTS↗

Radiative forcing from the 2020 shipping fuel regulation is large but hard to detect

Reduction in aerosol cooling unmasks greenhouse gas warming, exacerbating the rate of future warming. The strict sulfur regulation on shipping fuel implemented in 2020 (IMO2020) presents an opportunity to assess the potential impacts of such emission regulations and the detectability of deliberate aerosol perturbations for climate intervention. Here we employ machine learning to capture cloud natural variability and estimate a radiative forcing of +0.074 ±0.005 W m -2 related to IMO2020 associated with changes in shortwave cloud radiative effect over three low-cloud regions where shipping routes prevail. We find low detectability of the cloud radiative effect of this event, attributed to strong natural variability in cloud albedo and cloud cover. Regionally, detectability is higher for the southeastern Atlantic stratocumulus deck. These results raise concerns that future reductions in aerosol emissions will accelerate warming and that proposed deliberate aerosol perturbations such as marine cloud brightening will need to be substantial in order to overcome the low detectability.

54 ENVIRONMENTAL SCIENCES↗

TRACER-VOC: Speciated Volatile Organic Compounds at the Tracking Aerosol Convection Interactions Experiment Field Campaign Report

Formation of secondary organic aerosol (SOA) is responsible for the growth of particles into cloud condensation nuclei (CCN)-relevant sizes and accounts for a substantial fraction of aerosol mass in the troposphere. Despite its wide abundance and importance, capturing SOA in regional and climate models is still challenging due to complex chemical transformations involved in production of SOA. Oxidation products of biogenic hydrocarbons, such as isoprene, monoterpenes, and sesquiterpenes account for the largest fraction of SOA mass over the continents. As such, biogenic SOA is an important source of continental CCN, and has been recently shown to nucleate ice in the deposition mode. To better account for the processes involved in SOA formation in global and regional climate models, we need better measurements of sources and transformations of volatile organic compounds (VOCs), the precursors to SOA formation in the atmosphere. Understanding aerosol-deep convection interactions is an important science driver of the Tracking Aerosol Convection Interactions Experiment (TRACER), requiring a characterization of the critical controls on aerosol properties and processes, and how those properties and processes vary spatially and temporally in the Houston area. In that environment, the atmospheric photo-oxidative chemistry that drives the evolution and transformation of aerosol properties and processes is strongly impacted by the emission of VOCs, which have both anthropogenic (e.g., industrial, urban, transportation, biomass burning) and biogenic (e.g., marine) sources in the region. Understanding (and disentangling) the complex role of VOCs in such a heterogenous region requires high-time-resolution, speciated VOC measurements that are spatially resolved. To meet these measurement requirements, the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s time-of-flight proton transfer reaction-mass spectrometer (ToF-PTR-MS) was deployed during the TRACER intensive operational period (IOP) from June to September, 2022 at the ancillary site (ANC), which was sited to provide a characterization of the rural atmospheric environment in contrast to the main site.

54 ENVIRONMENTAL SCIENCES↗

A Model Intercomparison Study of Aerosol‐Cloud‐Turbulence Interactions in a Cloud Chamber: 1. Model Results

This study presents the first model intercomparison of aerosol‐cloud‐turbulence interactions in a controlled cloudy Rayleigh‐Bénard Convection chamber environment, utilizing the Pi Chamber at Michigan Technological University. We analyzed simulated cloud chamber‐averaged statistics of microphysics and thermodynamics in a warm‐phase, cloudy environment under steady‐state conditions at varying aerosol injection rates. Simulation results from seven distinct models (DNS, LES, and a 1D turbulence model) were compared. Our findings demonstrate that while all models qualitatively capture observed trends in droplet number concentration, mean radius, and droplet size distributions at both high and low aerosol injection rates, significant quantitative differences were observed. Notably, droplet number concentrations varied by over two orders of magnitude between models for the same injection rates, indicating sensitivities to the model treatments in droplet activation and removal and wall fluxes. Furthermore, inconsistencies in vertical relative humidity profiles and in achieving steady‐state liquid water content suggest the need for further investigation into the mechanisms driving these variations. Despite these discrepancies, the models generally reproduced consistent power‐law relationships between the microphysical variables. This model intercomparison underscores the importance of controlled cloud chamber experiments for validating and improving cloud microphysical parameterizations. Recommendations for future modeling studies are also highlighted, including constraining wall conditions and processes, investigating droplet/aerosol removal (including sidewall losses), and conducting simplified experiments to isolate specific processes contributing to model divergence and reduce model uncertainties.

54 ENVIRONMENTAL SCIENCES↗

Dual-loop Solvent-based CCS for Net Negative CO 2 Emissions with Lower Cost

This final technical report details the successful design, construction, and operational validation of an innovative dual-loop CO 2 capture technology designed to achieve deep decarbonization (>99%) from Natural Gas Combined Cycle (NGCC) power plants that results in the electricity with carbon intensity of approximate 42 kg CO 2 -eq/MWh, less than the electricity produced by solar PV. The integrated process couples a primary aqueous solvent (in this project, a water lean solvent – WLS) absorption loop for bulk CO 2 removal with a secondary potassium hydroxide (KOH) polishing loop featuring electrochemical regeneration. This architecture leverages the higher exergy efficiency of the primary loop while utilizing the fastest kinetic of the secondary loop to capture dilute residual CO 2 , achieving an overall capture rate of 99.9% and co-producing pure hydrogen after moisture being condensed and dehydrated. Technical feasibility was established through a comprehensive 2,000-hour experimental campaign on a bench-scale fully-integrated unit (using 4” absorber and 4” stripper) with the feeding flue gas flowrate in the range of 8-20 cfm, confirming the attainment of Technology Readiness Level (TRL) 4. The project executed extensive parametric testing followed by 1,000 hours of continuous steady-state testing, demonstrating exceptional process stability with the electrochemical regenerator exhibiting less than a 10% reduction in electrical conductivity over the duration of the campaign. Operational characterization gathering on the bench unit revealed distinct energy profiles for the hybrid system: the primary loop required approximately 280 kJ mol -1 for bulk removal, while the polishing loop required approximately 1,600 kJ mol -1 specifically when reducing dilute CO 2 concentrations from ~740 ppm down to <50 ppm. (Please note those energy values/numbers can only be viewed as relative relationship and should not be extrapolated as absolute values required for CO 2 capture). Furthermore, dynamic testing validated the system’s flexibility for utility applications, demonstrating a rapid process response time of <30 minutes to changes in flue gas flowrate. Emission monitoring confirmed that the dual-loop architecture effectively mitigates solvent losses, utilizing a water wash to remove entrained aerosols to <1 ppm. The Techno-Economic Analysis (TEA) indicates a cost of capture of $\$$59.3/tonne and a Levelized Cost of Electricity (LCOE) of 71.7 $\$$/MWh at the overall capture efficiency of 99.8% of total carbon in the flue gas stream, with sensitivity analysis identifying an economic optimum when the primary loop captures 97% of the total CO 2 . A Life Cycle Assessment (LCA) confirms the technology’s potential for net-negative emissions, determining a Global Warming Potential (GWP) of 52 kg CO 2 -eq/MWh—significantly lower than the baseline—which further decreases to 42 kg CO 2 -eq/MWh when crediting the displacement of conventional hydrogen production.

03 NATURAL GAS↗

Evaluation of E3SM Simulated Aerosols and Aerosol‐Cloud Interactions Across GCM and Convection‐Permitting Scales

This paper introduces an Earth system modeling testbed for predicting aerosols and aerosol‐cloud interactions (ACIs) at convection‐permitting scales. Using the Energy Exascale Earth System Model (E3SM) version 2 with a four‐mode Modal Aerosol Module, we conduct simulations at 3.25 km resolution on a regionally refined mesh (RRM) across four regions with distinct aerosol and cloud regimes. Results are compared with the standard 100 km E3SM configuration and evaluated against satellite, aircraft, and ground‐based observations. We find that increasing model resolution improves heavy precipitation simulation but amplifies positive bias in light drizzle at coarse resolution. These resolution‐induced changes affect cloud and aerosol properties to varying degrees across regions. Generally, cloud cover and liquid water path (LWP) show better agreement with satellite retrievals at 3.25 km, though surface‐based comparisons suggest otherwise. Aerosol composition remains poorly represented at both resolutions. The RRM increases Aitken mode aerosol number concentrations via enhanced new particle formation. However, accumulation mode aerosols are decreased at higher resolution as aerosol removals become more efficient. This partially contributes to fewer cloud condensation nuclei (CCN) and lower cloud droplet number concentrations (N d ), which produces larger model biases in some scenarios. These findings suggest that solely increasing horizontal resolution to kilometer scales is insufficient to broadly improve aerosol and cloud predictions without concurrent advancements in physical and chemical process representations. Nonetheless, the RRM moderately improves key ACI relationships such as CCN‐N d correlation, reflecting enhanced aerosol activation representation. The LWP‐N d relationship is also better captured by RRM, suggesting a better characterization of LWP adjustment.

Huang, Meng [Pacific Northwest National Laboratory↗

Geometry of Non-Diffusive Tracer Transport in Gridded Atmospheric Models

A first-order linear and numerically non-diffusive Eulerian transport algorithm, minVAR, was recently developed for preservation of correlations between interrelated tracers during advective transport. The present study extends this work by: (1) providing further investigation of several interesting geometric constructions found in contours of constant minVAR, short for minimum variance, through extension to three coordinate dimensions. These contours capture point-by-point representations of thousands of individual atmospheric aerosol and/or cloud particles as they evolve and are rendered on Eulerian grids at a level of sub-grid resolution limited only by numerical precision; and (2) exploration of geometric similarities between the Arakawa C-grid, used to obtain interpolated values of the wind field at grid scale and minVAR. In particular, we consider interpolation of the u and v horizontal components of wind velocity from grid to sub-grid scales. The last results are motivated by recent applications of the Weather Research and Forecasting (WRF) model applied in the coastal Houston region, where the recent TRacking Aerosol Convection Interactions ExpeRiment (TRACER) field campaign was organized. A unique and fully consistent mapping is obtained between particles moving along meteorological wind trajectories and the non-diffusive, non-dispersive representation of such trajectories on an Eulerian grid.

54 ENVIRONMENTAL SCIENCES↗

Seasonal variations in fire conditions are important drivers in the trend of aerosol optical properties over the south-eastern Atlantic

Abstract. From June to October, southern Africa produces one-third of the global biomass burning (BB) emissions by widespread fires. BB aerosols are transported westward over the south-eastern Atlantic with the mid-tropospheric winds, resulting in significant radiative effects. Ascension Island (ASI) is located midway between Africa and South America. From June 2016 to October 2017, a 17-month in situ observation campaign on ASI found a low single-scattering albedo (SSA) as well as a high mass absorption cross-section of black carbon (MACBC), demonstrating the strong absorbing marine boundary layer in the south-eastern Atlantic. Here we investigate the monthly variations of critical optical properties of BB aerosols, i.e. SSA and MACBC, during the BB seasons and the driving factors behind these variations. Both SSA and MACBC increase from June to August and decrease in September and October. The average SSA during the BB seasons is 0.81 at 529 nm wavelength, with the highest mean ∼ 0.85 in October and the lowest ∼ 0.78 in August. The absorption enhancement (Eabs) derived from the MACBC shows similar trends with SSA, with the average during the whole of the BB seasons at ∼ 1.96 and ∼ 2.07 in 2016 and 2017, respectively. As the Eabs is higher than the ∼ 1.5 commonly adopted value by climate models, this result suggests the marine boundary layer in the south-eastern Atlantic is more absorbing than model simulations. We find the enhanced ratio of BC to CO (ΔBC/ΔCO, equal to BC/ΔCO as the BC background concentration is considered to be 0) is well correlated with SSA and MACBC, providing a simple way to estimate the aerosol optical characteristics in the south-eastern Atlantic. The exponential function we proposed can approximate SSA and MACBC with BC/ΔCO, and when BC/ΔCO is small it can capture the rapid growth of SSA as BC/ΔCO decreases. BC/ΔCO is influenced by combustion conditions and aerosol scavenging. From the analysis of the location of BB, the primary source fuel, the water content in the fuel, combined with the mean cloud cover and precipitation in the transport areas of the BB plume, we conclude that the increase in BC/ΔCO from June to August is likely to be caused by burning becoming more flaming. The reduction in the water content of fuels may be responsible for the change in the burning conditions from June to August. The decrease in BC/ΔCO in September and October may be caused by two factors, one being a lower proportion of flaming conditions, possibly associated with a decrease in mean surface wind speed in the burning area, and the other being an increase in precipitation in the BB transport pathway, leading to enhanced aerosol scavenging, which ultimately results in an increase in SSA and MACBC.

54 ENVIRONMENTAL SCIENCES↗

Comparing multi-model ensemble simulations with observations and decadal projections of upper atmospheric variations following the Hunga eruption

The Hunga Tonga–Hunga Ha'apai Model–Observation Comparison (HTHH–MOC) project aims to comprehensively investigate the evolution of volcanic water vapor and sulfur emissions and their subsequent atmospheric impacts and underlying response mechanisms using state-of-the-art global climate models. This study evaluates multi-model ensemble simulations participating in the HTHH–MOC free-run experiment with climate projections for 10 years (2022–2032). Model results are evaluated against satellite observations to assess their ability to reproduce the observed evolution of stratospheric water vapor, aerosols, temperature, and ozone from 2022 to 2024. The participating models accurately capture the observed distribution patterns and associated upper atmospheric responses, providing confidence for their future projections. Model simulations suggest that the Hunga eruption-induced stratospheric water vapor anomaly lasts 4–7 years, with a water vapor e-folding time of 31–43 months. This prolonged water vapor perturbation leads to significant stratospheric and mesospheric cooling, resulting in significant ozone loss in the upper stratosphere and lower mesosphere for 7–10 years. Comparisons between simulations with both SO 2 and H 2 O emissions and those with H 2 O-only emissions indicate that the pronounced dipole response with upper-stratospheric cooling and lower-stratospheric warming is driven by the combined effects of SO 2 and H 2 O injections. These results highlight the prolonged atmospheric impacts of the Hunga eruption and the potential critical role of stratospheric water vapor in modulating long-term atmospheric chemistry and dynamics.

Zhuo, Zhihong [Univ. of Quebec, Montreal, QC (Cana↗

Charging of radioactive and environmental airborne particles

The charging of various airborne particles was investigated using single-particle levitation and charge-balance equations. Though radioactive decay and triboelectrification can induce charging, it is typically assumed that the aerosols in a radioactive plume will not carry significant charge at steady state since atmospheric particles can have their charge neutralized through the capture of adjacent counter-ions (i.e., diffusion charging). Here to assess this assumption, we directly measured the surface charge and charge density of various triboelectrically charged aerosols including radioactive uranium oxide (<1 μm), urban dust, Arizona desert dust, hydrophilic and hydrophobic silica nanoparticles, and graphene oxide powders using an electric field-assisted particle levitator in air. Of these particles, uranium oxide aerosols exhibited the highest surface charge density. Charge balance equations were employed to predict the average charge gained from radioactive decay as a function of time and to evaluate the effects of diffusion charging on triboelectrically charged radioactive and non-radioactive particles in the atmosphere. Simulation results show that particles, initially charged through triboelectrification, can be quickly discharged by diffusion charging in the absence of radioactive decay. Nevertheless, simulation results also indicate that particles can be strongly charged when they carry radionuclides. These experimental and simulation results suggest that radioactive decay can induce strong particle charging that may potentially affect atmospheric transport of airborne radionuclides.

54 ENVIRONMENTAL SCIENCES↗

Cloud condensation nuclei concentrations derived from the CAMS reanalysis

Determining number concentrations of cloud condensation nuclei (CCN) is one of the first steps in the chain in analysis of cloud droplet formation, the direct microphysical link between aerosols and cloud droplets, and a process key for aerosol–cloud interactions (ACI). However, due to sparse coverage of in situ measurements and difficulties associated with retrievals from satellites, a global exploration of their magnitude, source as well as temporal and spatial distribution cannot be easily obtained. Thus, a better representation of CCN numbers is one of the goals for quantifying ACI processes and achieving uncertainty-reduced estimates of their associated radiative forcing. Here, we introduce a new CCN dataset which is derived based on aerosol mass mixing ratios from the latest Copernicus Atmosphere Monitoring Service reanalysis (CAMSRA) in a diagnostic model that uses CAMSRA aerosol properties and a simplified kappa-Köhler framework suitable for global models. The emitted aerosols in CAMSRA are not only based on input from emission inventories using aerosol observations, they also have a strong tie to satellite-retrieved aerosol optical depth (AOD) as this is assimilated as a constraining factor in the reanalysis. Furthermore, the reanalysis interpolates for cases of poor or missing retrievals and thus allows for a full spatiotemporal quantification of CCN numbers. The derived CCN dataset captures the general trend and spatial and temporal distribution of total CCN number concentrations and CCN from different aerosol species. A brief evaluation with ground-based in situ measurements demonstrates the improvement of the modelled CCN over the sole use of AOD as a proxy for CCN as the overall correlation coefficient improved from 0.37 to 0.71. However, we find the modelled CCN from CAMSRA to be generally high biased and find a particular erroneous overestimation at one heavily polluted site which emphasises the need for further validation. The CCN dataset (https://doi.org/10.26050/WDCC/QUAERERE_CCNCAMS_v1, Block, 2023), which is now freely available to users, features 3-D CCN number concentrations of global coverage for various supersaturations and aerosol species covering the years 2003–2021 with daily frequency. This dataset is one of its kind as it offers lots of opportunities to be used for evaluation in models and in ACI studies.

54 ENVIRONMENTAL SCIENCES↗

Realism of Lagrangian Large Eddy Simulations Driven by Reanalysis Meteorology: Tracking a Pocket of Open Cells Under a Biomass Burning Aerosol Layer

An approach to drive Lagrangian large eddy simulation (LES) of boundary layer clouds with reanalysis data is presented and evaluated using satellite (Spinning Enhanced Visible and Infrared Imager, SEVIRI) and aircraft (Cloud-Aerosol-Radiation Interactions and Forcing, CLARIFY) measurements. The simulations follow trajectories of the boundary layer flow. They track the formation and evolution of a pocket of open cells (POC) underneath a biomass burning aerosol layer in the free troposphere. The simulations reproduce the evolution of observed stratocumulus cloud morphology, cloud optical depth, and cloud drop effective radius, and capture the timing of the cloud state transition from closed to open cells seen in the satellite imagery on the three considered trajectories. They reproduce a biomass burning aerosol layer identified by the in-situ aircraft measurements above the inversion of the POC. Entrainment of aerosol from the biomass burning layer into the POC is limited to the extent of having no impact on cloud- or boundary layer properties, in agreement with the CLARIFY observations. The two-moment bin microphysics scheme used in the simulations reproduces the in-situ cloud microphysical properties reasonably well. A two-moment bulk microphysics scheme reproduces the satellite observations in the non-precipitating closed-cell state, but overestimates liquid water path and cloud optical depth in the precipitating open-cell state due to insufficient surface precipitation. A boundary layer cold and dry bias occurring in LES can be counteracted by reducing the grid aspect ratio and by tightening the large scale wind speed nudging towards the surface.

54 ENVIRONMENTAL SCIENCES↗

Pan-Arctic seasonal cycles and long-term trends of aerosol properties from 10 observatories

Even though the Arctic is remote, aerosol properties observed there are strongly influenced by anthropogenic emissions from outside the Arctic. This is particularly true for the so-called Arctic haze season (January through April). In summer (June through September), when atmospheric transport patterns change, and precipitation is more frequent, local Arctic sources, i.e., natural sources of aerosols and precursors, play an important role. Over the last few decades, significant reductions in anthropogenic emissions have taken place. At the same time a large body of literature shows evidence that the Arctic is undergoing fundamental environmental changes due to climate forcing, leading to enhanced emissions by natural processes that may impact aerosol properties. In this study, we analyze 9 aerosol chemical species and 4 particle optical properties from 10 Arctic observatories (Alert, Kevo, Pallas, Summit, Thule, Tiksi, Barrow/Utgiavik, Villum, and Gruvebadet and Zeppelin Observatory – both at Ny-Ålesund Research Station) to understand changes in anthropogenic and natural aerosol contributions. Variables include equivalent black carbon, particulate sulfate, nitrate, ammonium, methanesulfonic acid, sodium, iron, calcium and potassium, as well as scattering and absorption coefficients, single scattering albedo and scattering Ångström exponent. First, annual cycles are investigated, which despite anthropogenic emission reductions still show the Arctic haze phenomenon. Second, long-term trends are studied using the Mann–Kendall Theil–Sen slope method. We find in total 41 significant trends over full station records, i.e., spanning more than a decade, compared to 26 significant decadal trends. The majority of significantly declining trends is from anthropogenic tracers and occurred during the haze period, driven by emission changes between 1990 and 2000. For the summer period, no uniform picture of trends has emerged. Twenty-six percent of trends, i.e., 19 out of 73, are significant, and of those 5 are positive and 14 are negative. Negative trends include not only anthropogenic tracers such as equivalent black carbon at Kevo, but also natural indicators such as methanesulfonic acid and non-sea-salt calcium at Alert. Positive trends are observed for sulfate at Gruvebadet. No clear evidence of a significant change in the natural aerosol contribution can be observed yet. However, testing the sensitivity of the Mann–Kendall Theil–Sen method, we find that monotonic changes of around 5 % yr –1 in an aerosol property are needed to detect a significant trend within one decade. This highlights that long-term efforts well beyond a decade are needed to capture smaller changes. It is particularly important to understand the ongoing natural changes in the Arctic, where interannual variability can be high, such as with forest fire emissions and their influence on the aerosol population. To investigate the climate-change-induced influence on the aerosol population and the resulting climate feedback, long-term observations of tracers more specific to natural sources are needed, as well as of particle microphysical properties such as size distributions, which can be used to identify changes in particle populations which are not well captured by mass-oriented methods such as bulk chemical composition.

54 ENVIRONMENTAL SCIENCES↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic charge of the filter was correlated with a reduction in capturing particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test and reduction in aerosol filtering efficiency. Key Words: N95 respirators, respirators, airborne transmission, pandemic prevention, COVID-19, gamma sterilization

COVID-19↗