Designing for Supply and Return Air System Interaction in Residential Buildings

Standard practice for HVAC return design has evolved from running a dedicated return to each room with a supply, to systems with returns in more centrally located areas of the home with jump ducts, transfer grilles, or simply door undercuts used as return air pathways from isolated rooms . In these latter systems, hallways and stairwells act as large open ducts for conveying air back to a single (or sometimes multiple) central return. When partition doors to an isolated room are closed, the return airflow resistance goes up, significantly impacting airflow balance if an adequate relief pathway is not installed. Airflow imbalances can lead to comfort and building durability issues and increased envelope leakage. To combat this, some jurisdictions have requirements for return air pathways. The supply system topology – or layout - impacts the airflow balance stability in response to adjustments of return pathway resistances. Branching supply topologies typically have reduced static pressure after each split. The static pressure at the final split will be lower than the primary supply plenum. Because of this, if there is a restriction in a room’s return path, supply airflow will tend to redistribute to adjacent ducts at the end of the branch. A properly designed trunk and branch supply system can effectively equalize static pressure by reducing the cross sectional area after each takeoff . Maintaining static pressure within the trunk will reduce the system’s sensitivity to changes in return paths. However, in practice, it is difficult to design and time consuming to install a complex supply plenum. Velocity effects and poor takeoff placement also impact airflow balance. This fact sheet considers return systems in three main categories: distributed, with a return duct to each room; multiple central, with one return grille on each floor of a home; and single central, with a single return grille located near the air handling unit. Three supply categories are also considered: radial splitter box, trunk and branch, and home-run with all ducts connecting directly to a central manifold. A complete description of the modeling work and results can be found in the companion technical report.

buildings↗

An encoder–decoder LSTM-based EMPC framework applied to a building HVAC system

Numerous studies have demonstrated the benefit of economic model predictive control (EMPC) applied to building heating, ventilation, and air conditioning (HVAC) systems. However, the construction and training of predictive models for building HVAC systems are widely recognized as a key technological barrier preventing large-scale adoption of EMPC for buildings. In this work, an encoder–decoder long short-term memory-based EMPC framework is developed. The key advantage of the approach is that a model may be automatically generated from a list of inputs and outputs. From the definition of inputs and outputs, the constructed model may be trained and automatically embedded into the EMPC framework for real-time estimation and control. The overall end-to-end EMPC framework from model training to on-line estimation and control are described. To this end, the encoder–decoder model provides a natural framework for state estimation (encoder), which is required to provide an initial condition for the predictive model of EMPC (decoder). Closed-loop simulations using EnergyPlus are performed to demonstrate the approach. The simulated closed-loop system consists of a building zone from a multi-zone building, which is served by an air handling unit-variable air volume HVAC system. For the HVAC example considered, the trained encoder–decoder model can predict the indoor air temperature and HVAC sensible cooling rate of a building zone over a two-day horizon with high accuracy. Overall, we find that considering a time-of-use electric rate structure, the EMPC, which manipulates the zone temperature setpoint, can reduce the HVAC power consumption cost relative to keeping the zone temperature setpoint at its maximum value (i.e., minimum energy approach).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-Enabled Predictive Control for Building HVAC Systems

Model predictive control is widely used as a control technology for the computation of optimal control inputs of building heating, ventilating, and air conditioning (HVAC) systems. However, both the benefits and widespread adoption of model predictive control (MPC) are hindered by the effort of model creation, calibration, and accuracy of the predictions. In this paper, we apply the data-enabled predictive control (DeePC) algorithm for designing controls for building HVAC systems. The algorithm solely depends on input/output data from the system to predict future state trajectories without the need for system identification. The algorithm relies on the idea that a vector space of all input–output trajectories of a discrete-time linear time-invariant (LTI) system is spanned by time-shifts of a single measured trajectory, given the input signal is persistently exciting. Closed-loop simulations using EnergyPlus are performed to demonstrate the approach. The simulated building modeled in EnergyPlus is a modified commercial large office prototype building served by an air handling unit-variable air volume HVAC system. Temperature setpoints of zones are used as control variables to minimize the HVAC energy cost of the building considering a time-of-use electricity rate structure. Furthermore, sensitivity analysis is conducted to gain insights into the effect of parameter tuning on DeePC performance. Simulation results are used to illustrate the performance of the algorithm and compare the algorithm with model-based MPC and occupancy-based setpoint controller. Overall, DeePC achieves similar performance compared to MPC for lower engineering effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A transfer learning approach to energy-efficient control of small and medium-sized commercial buildings

Model-free reinforcement learning (RL) provides a data-driven and adaptive approach to optimize building energy use while satisfying occupant comfort. This powerful tool does not need any prior knowledge about the environment and system it is optimizing and can adapt its policy based on the changes in captures. Like any other data-driven tool, it faces high training costs due to the extensive agent-environment interactions required to capture long-term building dynamics and user comfort. Transfer learning, particularly policy distillation, offers a promising way to accelerate training by leveraging pretrained RL agents in different building and system types. Here, this study investigates online student distillation, in which the student model updates its neural network weights using outputs from teacher models. The work introduces a student distillation strategy designed for efficient knowledge transfer, along with a teacher selection method that ensures high-quality guidance. The approach is validated using a highly calibrated whole building energy model for a small/medium commercial building test facility. Results show substantial reductions in training time and data requirements while surpassing the performance of ASHRAE Guideline 36, an advanced rule-based control strategy. The distilled RL model required 45% less data and achieved 20% higher cumulative rewards than a state-of-the-art RL model, with faster convergence and lower energy consumption. These outcomes demonstrate that effective transfer learning enables a scalable and data-efficient energy management solution for commercial buildings.

ASHRAE guideline 36↗

Chilled water temperature set-point reset based on outdoor air temperature and its cooling energy performance in an office building

Here, in this study, the cooling energy performance of two strategies for controlling ChWT (chilled water temperature) are compared: the conventional control strategy of constantly fixing ChWT and the OAT (outdoor air temperature) compensation control strategy that adjusts ChWT according to the changes in OAT. OAT compensation control strategy was modeled and realized based on Appendix G of ASHRAE Standard 90.1. It was confirmed that applying OAT compensation control strategy can significantly reduce chiller energy consumption, which accounts for the largest portion of total cooling energy consumption. It was found that the difference in total cooling energy consumption between applying the conventional control of constantly fixing ChWT to 6 °C and applying the OAT compensation control was approximately 8 % and 3 % during spring (March to May) and summer (June to August), respectively. Additionally, during the fall (September–November) period, about 7 % of total cooling energy consumption could be saved.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Integration of Wi-Fi Location-Based Services to Optimize Energy Efficient Commercial Building Operations

This project investigated and demonstrated the use of Wi-Fi Location-Based Services (LBS) to perform occupancy sensing in commercial buildings. Wi-Fi LBS can be used to detect the presence of Wi-Fi enabled mobile devices and laptops that accompany occupants as they move through the building. These signals can be used to determine occupant presence, head count, and location. When integrated with the building automation system, this emerging technology approach can be used to manage other connected systems such as lighting and HVAC to reduce energy usage in the building and improve occupant comfort. An open source location detection algorithm was developed, which uses data collected from three or more Wi-Fi access points to determine the presence and estimate the location of mobile devices and laptops. Access points can detect Wi-Fi enabled devices even if they are not connected to the existing Wi-Fi network. Building occupancy is determined based on the presence, location, and movement of these devices through the space. From lab and small-scale in-situ testing, the Location Detection Algorithm (LDA) was found to be accurate to within 10 feet and could be further refined by tuning the algorithm for the specific space characteristics such as layout and obstructions (walls, furniture, etc.). An open source method to integrate the occupancy data with existing building automations systems was investigated. The Wi-Fi occupancy sensing approach was then demonstrated and validated at commercial buildings located in Saint Paul, MN; Madison, WI; New York City; and Fort Worth, TX.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar heating system final design package

The system is composed of a warm air collector, a logic control unit and a universal switching and transport unit. The collector was originally conceived and designed as an integrated roof/wall system and therefore provides a dual function in the structure. The collector serves both as a solar energy conversion system and as a structural weather resistant skin. The control unit provides totally automatic control over the operation of the system. It receives input data from sensor probes in collectors, storage and living space. The logic was designed so as to make maximum use of solar energy and minimize use of conventional energy. The transport and switching unit is a high-efficiency air-handling system equipped with gear motor valves that respond to outputs from the control system. The fan unit was designed for maximum durability and efficiency in operation, and has permanently lubricated ball bearings and excellent air-handling efficiency.

Source record↗

Experimental Investigation of the Effect of Air-Handling and DME-Propane Blends on the Performance and Emissions of a 4-Cylinder CI Engine

Dimethyl ether (DME) is considered an excellent alternative to diesel because of its higher cetane number and lower carbon content. Additionally, DME can be blended with abundantly available propane with minimal modifications to the propane infrastructure. This paper focuses on an experimental investigation of the effect of air-handling i.e., boost pressure and exhaust gas recirculation (EGR), and DME-propane blends on the combustion and emissions performance of a light-duty, four-cylinder, compression ignition (CI) engine. Here, the boost pressure and EGR sweeps were carried out and showed that higher boost pressures resulted in increased brake thermal efficiencies (BTE) at the expense of higher NOx emissions which could be reduced by an increase in EGR. The fuel sweeps were carried out at 0, 15 and 25% propane (neat, 85% and 75% DME) with 0% and 25% EGR. The fuel sweeps indicated that the ignition delay (ID) increased and burn duration (BD) decreased monotonically when the blend increased to 25% propane/75% DME. The results suggest optimum engine performance with neat DME at 105 kPa boost pressure and 25% EGR with propane addition improving the BTE with negligible increase in emissions. Higher contents of Propane, up to 25%, did not affect the variability of combustion, with standard deviations of burn duration and peak cylinder pressures below 1% for all test cases.

air-handling↗

An integrated regenerative air revitalization system for spacecraft

Progress towards development of an air revitalization system (ARS) for spacecraft breathable atmosphere regeneration is assessed, and a preliminary design for a one-person ARS is described. The ARS is considered a necessary component of any permanently manned orbital station, and studies have demonstrated that penalties for expendable air supplies justify an ARS for missions longer than 40 days. CO2 must be removed and O2 returned along with N2, which can be extracted from hydrazine, with the H2 component returning to the operation of the CO2 reduction subsystem. An experimental ARS (ARX-1) features a cabin humidity control unit, a CO2 concentrator, an air-cooled CO2 reduction reactor, an oxygen generator (electrolysis), the hydrazine N2 generator, and a water handling unit. A 120-day test demonstrated one-button startup and 480 hr operation in a normal mode.

Noyes, G. P.↗

Solar heating and hot water system installed at Municipal Building complex, Abbeville, South Carolina

Information on the solar energy system installed at the new municipal building for the City of Abbeville, SC is presented, including a description of solar energy system and buildings, lessons learned, and recommendations. The solar space heating system is a direct air heating system. The flat roof collector panel was sized to provide 75% of the heating requirement based on an average day in January. The collectors used are job-built with two layers of filon corrugated fiberglass FRP panels cross lapped make up the cover. The storage consists of a pit filled with washed 3/4 in - 1 1/2 in diameter crushed granite stone. The air handler includes the air handling mechanism, motorized dampers, air circulating blower, sensors, control relays and mode control unit. Solar heating of water is provided only those times when the hot air in the collector is exhausted to the outside.

Source record↗

Green Applications for Space Power Project

Spacecraft propulsion and power for many decades has relied on Hydrazine monopropellant technology for auxiliary power units (APU), orbital circularization, orbit raising/lowering and attitude control. However, Hydrazine is toxic and therefore requires special ground handling procedures to ensure launch crew safety. The Swedish Company ECAPS has developed a technology based upon the propellant Ammonium Dinitramide (ADN) that offers higher performance, higher density and reduced ground handling support than Hydrazine. This blended propellant is called LMP-103S. Currently, the United States Air Force (USAF) is pursuing a technology based on Hydroxyl Ammonium Nitrate (HAN, otherwise known as AF-M315E) with industry partners Aerojet and Moog. Based on the advantages offered by these propellants, MSFC should explore powering APU's with these propellants. Due to the availability of space hardware, the principal investigator has found a collection of USAF hardware, that will act as a surrogate, which operates on a Hydrazine derivative. The F-16 fighter jet uses H-70 or 30% diluted Hydrazine for an Emergency Power Unit (EPU) which supplies power to the plane. The PI has acquired two EPU's from planes slated for destruction at the Davis Monthan AFB. This CIF will include a partnership with 2 other NASA Centers who are individually seeking seed funds from their respective organizations: Kennedy Space Center (KSC) and Dryden Flight Research Center (DFRC). KSC is preparing for future flights from their launch pads that will utilize green propellants and desire a low-cost testbed in which to test and calibrate new leak detection sensors. DFRC has access to F-16's which can be used by MSFC & KSC to perform a ground test that demonstrates emergency power supplied to the jet. Neither of the green propellant alternatives have been considered nor evaluated for an APU application. Work has already been accomplished to characterize and obtain the properties of these 2 propellants. However, the spacecraft are using existing leak detection sensors that are typically used for Hydrazine. Using these green propellants for the APU application requires decrementing their TRL down to 3. This task would aim to establish a TRL of 4 at conclusion by showing a proof of concept with a KSC-instrumented EPU asset at the MSFC Component Development Area (CDA). The task to accomplish this is called Green Application for Space Power or GRASP.

Robinson, Joel↗

HVAC End-of-Life: Options and Best Practices

When heating, ventilating, and air-conditioning (HVAC) systems reach end-of-life status, building owners typically seek the quickest, most cost-effective replacement. Although there are several rooftop unit (RTU) replacement tool kits and programs to guide clients through this process, there is limited information on how to handle end-of-life HVAC systems. This fact sheet provides relevant information to help building owners manage proper disposal of HVAC systems, how to navigate regulations, and how to recover economic value from old systems.

30 DIRECT ENERGY CONVERSION↗

NASA's Center Innovation Fund (CIF) Internal Research and Development (IRAD) Handling Qualities Study on the Mikrolar Motion Platform Test Report

In order to support the National Aeronautics and Space Administration’s (NASA) Extravehicular Activity and Surface Mobility Program (EHP), system engineers, designers, and researchers embarked on a yearlong challenge to develop a new lunar rover-based motion table simulator to study handling qualities of lunar rovers in the lunar South Pole region, support development research for any lunar rover vendor, and provide a lunar training capability for future lunar/planetary astronauts. In 1989, the United Kingdom’s Royal Air Force Institute of Aviation Medicine (RAF-IAM) stated that motion platforms are the only simulation devices capable of fully stimulating the body motion sensors. They confirmed that motion platforms can impart accelerations to the whole body and therefore exercise the automatic motion feedback-loop that operators are used to. With both visual and motion cues handling the vehicle becomes more realistic. Strachan (2019) con-firms motion cueing from a well set-up motion platform has been found to be important especially in conditions such as night or reduced visibility where motion cues may be more relied upon

Motion Table↗

Scoping Thermal Response Calculations of RNS Waste During Transport to and Disposal at the WIPP

Sandia National Laboratories (SNL) was contracted by the United States Department of Energy Environmental Management (DOE-EM), Los Alamos Field Office to perform mechanical and thermal scoping calculations as part of a study seeking to understand the ignitability risk of the Remediated Nitrate Salts (RNS) waste drums during transportation from the Waste Control Specialists (WCS) facility to Waste Isolation Pilot Plant (WIPP) and permanent disposal of the waste at WIPP. The scoping thermal simulations described in this report pertain to thermal calculations performed with a packaging system consisting of one Standard Waste Box (SWB) loaded with drums placed inside a Standard Large Box 2 (SLB2). During transportation, the SLB2 is inside Transuranic Package Transporter Model III (TRUPACT-III), which provides the third layer of the packaging. Once at the WIPP, it is assumed the SLB2 is extracted from the TRUPACT-III and maintained above ground, and then subsequently placed underground for permanent disposal. In these proposed configurations, the space between the SLB2 and the SWB is always filled by a layer of insulation consisting of air-filled glass microbubbles except for the bottom which rests directly on the SLB2. The thermal scoping calculations described in this report specifically address whether the introduction of external heat inputs, combined with the contributions from the internally generated radiolytic decay heat and chemical reactions, lead to an unstable thermal state during the time of its movement and placement in the permanent disposal location. The external heat inputs are of two forms: 1) ambient thermal irradiation (e.g., solar and ambient storage/disposal temperatures) and 2) accident-induced fire. Three scoping calculation scenarios were derived as representative, conservative scenarios: 1A) TRUPACT-III transient transportation, 1B) SLB2 48-hour outdoor storage with solar radiation, and 2) fully-engulfing fire during SLB2 handling or emplacement following a steady-state analysis in a 38 °C environment. All the simulated scenarios are conservative relative to the operational conditions expected for handling the waste package during transportation and placement in the WIPP underground disposal unit. The predictions obtained from simulating the three exposure scenarios revealed that adding the SLB2 and the air-filled glass microbubbles to the transport and storage/disposal configurations provides additional thermal protection of the drums beyond what the SWB provides alone, both during long-term above ground insolation and underground during a fire accident. Under the current transportation/storage/disposal concepts, the degree of protection provided by the packaging concept is sufficient to prevent the waste from being ignitable. The simulation results demonstrate that there is adequate margin to safely transport and place the RNS waste from WCS to the WIPP under the current operational concept.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Conducting Research on the International Space Station Using the EXPRESS Rack Facilities

Conducting Research on the International Space Station using the EXPRESS Rack Facilities. Sean W. Thompson and Robert E. Lake. NASA Marshall Space Flight Center, Huntsville, AL, USA. Eight "Expedite the Processing of Experiments to Space Station" (EXPRESS) Rack facilities are located within the International Space Station (ISS) laboratories to provide standard resources and interfaces for the simultaneous and independent operation of multiple experiments within each rack. Each EXPRESS Rack provides eight Middeck Locker Equivalent locations and two drawer locations for powered experiment equipment, also referred to as sub-rack payloads. Payload developers may provide their own structure to occupy the equivalent volume of one, two, or four lockers as a single unit. Resources provided for each location include power (28 Vdc, 0-500 W), command and data handling (Ethernet, RS-422, 5 Vdc discrete, +/- 5 Vdc analog), video (NTSC/RS 170A), and air cooling (0-200 W). Each rack also provides water cooling (500 W) for two locations, one vacuum exhaust interface, and one gaseous nitrogen interface. Standard interfacing cables and hoses are provided on-orbit. One laptop computer is provided with each rack to control the rack and to accommodate payload application software. Four of the racks are equipped with the Active Rack Isolation System to reduce vibration between the ISS and the rack. EXPRESS Racks are operated by the Payload Operations Integration Center at Marshall Space Flight Center and the sub-rack experiments are operated remotely by the investigating organization. Payload Integration Managers serve as a focal to assist organizations developing payloads for an EXPRESS Rack. NASA provides EXPRESS Rack simulator software for payload developers to checkout payload command and data handling at the development site before integrating the payload with the EXPRESS Functional Checkout Unit for an end-to-end test before flight. EXPRESS Racks began supporting investigations onboard ISS on April 24, 2001 and will continue through the life of the ISS.

Thompson, Sean W.↗

Conducting Research on the International Space Station Using the EXPRESS Rack Facilities

Eight "Expedite the Processing of Experiments to Space Station" (EXPRESS) Rack facilities are located within the International Space Station (ISS) laboratories to provide standard resources and interfaces for the simultaneous and independent operation of multiple experiments within each rack. Each EXPRESS Rack provides eight Middeck Locker Equivalent locations and two drawer locations for powered experiment equipment, also referred to as sub-rack payloads. Payload developers may provide their own structure to occupy the equivalent volume of one, two, or four lockers as a single unit. Resources provided for each location include power (28 Vdc, 0-500 W), command and data handling (Ethernet, RS-422, 5 Vdc discrete, +/- 5 Vdc analog), video (NTSC/RS 170A), and air cooling (0-200 W). Each rack also provides water cooling (500 W) for two locations, one vacuum exhaust interface, and one gaseous nitrogen interface. Standard interfacing cables and hoses are provided on-orbit. One laptop computer is provided with each rack to control the rack and to accommodate payload application software. Four of the racks are equipped with the Active Rack Isolation System to reduce vibration between the ISS and the rack. EXPRESS Racks are operated by the Payload Operations Integration Center at Marshall Space Flight Center and the sub-rack experiments are operated remotely by the investigating organization. Payload Integration Managers serve as a focal to assist organizations developing payloads for an EXPRESS Rack. NASA provides EXPRESS Rack simulator software for payload developers to checkout payload command and data handling at the development site before integrating the payload with the EXPRESS Functional Checkout Unit for an end-to-end test before flight. EXPRESS Racks began supporting investigations onboard ISS on April 24, 2001 and will continue through the life of the ISS.

Thompson, Sean W.↗

Conducting Research on the International Space Station using the EXPRESS Rack Facilities

Eight "Expedite the Processing of Experiments to Space Station" (EXPRESS) Rack facilities are located within the International Space Station (ISS) laboratories to provide standard resources and interfaces for the simultaneous and independent operation of multiple experiments within each rack. Each EXPRESS Rack provides eight Middeck Locker Equivalent locations and two drawer locations for powered experiment equipment, also referred to as sub-rack payloads. Payload developers may provide their own structure to occupy the equivalent volume of one, two, or four lockers as a single unit. Resources provided for each location include power (28 Vdc, 0-500 W), command and data handling (Ethernet, RS-422, 5 Vdc discrete, +/- 5 Vdc analog), video (NTSC/RS 170A), and air cooling (0-200 W). Each rack also provides water cooling for two locations (500W ea.), one vacuum exhaust interface, and one gaseous nitrogen interface. Standard interfacing cables and hoses are provided on-orbit. One laptop computer is provided with each rack to control the rack and to accommodate payload application software. Four of the racks are equipped with the Active Rack Isolation System to reduce vibration between the ISS and the rack. EXPRESS Racks are operated by the Payload Operations Integration Center at Marshall Space Flight Center and the sub-rack experiments are operated remotely by the investigating organization. Payload Integration Managers serve as a focal to assist organizations developing payloads for an EXPRESS Rack. NASA provides EXPRESS Rack simulator software for payload developers to checkout payload command and data handling at the development site before integrating the payload with the EXPRESS Functional Checkout Unit for an end-to-end test before flight. EXPRESS Racks began supporting investigations onboard ISS on April 24, 2001 and will continue through the life of the ISS.

Thompson, Sean W.↗

Benefits and challenges in deployment of low global warming potential R290 refrigerant for room air conditioning equipment in California

High global warming potential gases (“high GWP”) are the fastest growing sector of greenhouse gas emissions in the world and in California and are primarily used as refrigerant gases in refrigeration and cooling equipment. Hydrofluorocarbons (HFCs) refrigerants are the dominant type of high GWP gases with GWP values thousands of times larger than CO 2 on a 100-year timescale. Refrigerant-grade propane (“R290”) has a very low GWP (GWP = 3.3) with good thermodynamic properties and good cooling equipment performance but the flammability of any leaked refrigerant makes equipment design, handling, and maintenance critical factors to manage. This paper focuses on the potential climate benefits and costs of transitioning to R290 refrigerant in small room air conditioning (AC) units, specifically window AC, packaged terminal AC/heat pumps (PTAC/PTHP), and mini-split heat pumps. Overall climate impact for a transition to all three types of air conditioning units in the 2022–2051 timeframe is found to be from 15 to 64 million metric tons of greenhouse gas (GHG) savings in California with a cost of saved CO 2 eq that ranges from $14.50 per ton of CO 2 eq saved to -$50.30 per ton of CO 2 eq saved (net savings) depending on whether the baseline refrigerant is R32 or R410A and depending on the relative energy efficiency for R290 units compared to baseline units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗