RCT: Module 2.06, Air Sampling Program and Methods, Course 8772

The inhalation of radioactive particles is the largest cause of an internal radiation dose. Airborne radioactivity measurements are necessary to ensure that the control measures are and continue to be effective. Regulations govern the allowable effective dose equivalent to an individual. The effective dose equivalent is determined by combining the external and internal dose equivalent values. Typically, airborne radioactivity levels are maintained well below allowable levels to keep the total effective dose equivalent small. This course will prepare the student with the skills necessary for RCT qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and will provide in-the-field skills.

61 RADIATION PROTECTION AND DOSIMETRY↗

Stratospheric air sampling platform/sensor tradeoffs

Results of a study are described in which in-situ and remote sensing instrumentation are considered for accommodation on airborne platforms capable of reaching stratospheric altitudes. The instrumentation measures trace species of importance to present concerns regarding stratospheric pollution and possible ozone depletion. The platforms examined were the U-2, modified U-2, balloon, rocket, F-15 flown in a zoom-climb maneuver, YF-12, and remotely piloted vehicle (RPV). The sensors and performance characteristics of the platforms are described and special problems of sensor-platform integration are discussed. A typical latitudinal sampling mission is utilized to describe platform logistics problems and how the platforms might perform such missions.

Arno, R. D.↗

Tabulations of ambient ozone data obtained by GASP (Global Air Sampling Program) airliners, March 1975 to July 1979

Tabulations are given of GASP ambient ozone mean, standard deviation, median, 84th percentile, and 98th percentile values, by month, flight level, and geographical region. These data are tabulated to conform to the temporal and spatial resolution required by FAA Advisory Circular 120-38 (monthly by 2000 ft in altitude by 5 deg in latitude) for climatological data used to show compliance with cabin ozone regulations. In addition seasonal x 10 deg latitude tabulations are included which are directly comparable to and supersede the interim GASP ambient ozone tabulations given in appendix B of FAA-EE-80-43 (NASA TM-81528). Selected probability variations are highlighted to illustrate the spatial and temporal variability of ambient ozone and to compare results from the coarse and fine grid analyses.

Jasperson, W. H.↗

Observed and model-calculated NO2/NO ratios in tropospheric air sampled during the NASA GTE/CITE-2 field study

Airborne measurements of NO2/NO ratios in the free troposphere, obtained using two-photon LIF (TP-LIF) and chemiluminescence (CL) detectors during the NASA Global Tropospheric Experiment Chemical Instrumentation Test and Evaluation 2 (CITE 2) program in summer 1986, are analyzed and compared with the predictions of a photochemical model. The derivation of the model is outlined, with an emphasis on the role of peroxy radicals in the fast photochemical cycling of NO and NO2 and the production of O3; the CITE 2 instruments and flight protocols are described; and the results are presented in extensive tables and graphs and discussed in detail. It was found that on three CITE 2 flights the CL data were systematically greater than the TP-LIF data; when these data were removed, the averaged values of the two instruments agreed to within 1 percent. The NO2/NO ratios predicted by the model are shown to be consistent with the measurements, although usually 20-25 percent lower.

Chameides, W. L.↗

Use of Electronic Hand-held Devices for Collection of Savannah River Site Environmental Data - 13329

Savannah River Nuclear Solutions has begun using Xplore Tablet PC's to collect data in the field for soil samples, groundwater samples, air samples and round sheets at the Savannah River Site (SRS). EPA guidelines for groundwater sampling are incorporated into the application to ensure the sample technician follows the proper protocol. The sample technician is guided through the process for sampling and round sheet data collection by a series of menus and input boxes. Field measurements and well stabilization information are entered into the tablet for uploading into Environmental Restoration Data Management System (ERDMS). The process helps to eliminate input errors and provides data integrity. A soil sample technician has the ability to collect information about location of sample, field parameter, describe the soil sample, print bottle labels, and print chain of custody for the sample that they have collected. An air sample technician has the ability to provide flow, pressure, hours of operation, print bottle labels and chain of custody for samples they collect. Round sheets are collected using the information provided in the various procedures. The data are collected and uploaded into ERDMS. The equipment used is weather proof and hardened for the field use. Global Positioning System (GPS) capabilities are integrated into the applications to provide the location where samples were collected and to help sample technicians locate wells that are not visited often. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance evaluation of a high-sensitivity tritium gas monitor using a pulse-shaping analyzer

A tritium gas monitor was developed by applying several techniques including pulse shape analysis. The optimum analyzer values were determined for parameters such as the bias (voltage) applied to the detector, counting gas flow rate, and mixing ratio of sample air to counting gas using an enclosed tritium reference source. After applying these optimized parameters, the factor for converting counting rate to tritium concentration was determined by conducting an experiment using tritiated methane gas. Finally, the detection limit of the monitor for air samples containing tritium was determined based on the conversion factor. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stratospheric Age Spectra and Mean Ages from In Situ Observations of Carbon Dioxide

In situ observations of CO2 obtained from 1992 through 2000 using the NASA ER-2 aircraft and high-altitude balloons show that seasonal and interannual variations in CO2 mixing ratios propagate from the troposphere into the lower stratosphere via the tropical tropopause, along with the long-term trend due to fossil fuel combustion. These signals spread laterally and vertically, providing detailed quantitative information about the transport history of sampled air. We have used these data to derive age spectra and mean ages that can be compared with results from models of the stratospheric circulation. For an air parcel at a point in the stratosphere, the age spectrum is defined as the probability distribution function for transit times from the tropical tropopause for each fluid element comprising the parcel. The mean age is the average transit time, corresponding to the first moment of the age spectrum. Age spectra have been derived for altitudes below approximately 20 km for the tropics and for northern midlatitudes where there is sufficient data and where the amplitudes of the seasonal and interannual oscillations in CO2 mixing ratios are large enough to be detected. Tropical age spectra are narrow, with seasonal variation indicating faster ascent during northern winter, consistent with a circulation driven by breaking of extratropical waves. The midlatitude CO2 data are consistent with bimodal age spectra, which could result from a subtropical "barrier" to horizontal exchange over a substantial altitude region. Seasonally resolved mean ages are available with nearly pole-to-pole coverage below 20 km and in the tropics and at middle and high northern latitudes up to the maximum altitude reached by the balloons (approximately 30 km). At ER-2 altitudes, steep meridional gradients in mean age are observed in the subtropics. Between 20 and 30 km, midlatitude air is approximately 2 years older than tropical air at the same altitude. The oldest air sampled was in the Arctic polar vortex with a mean age of .5 plus or minus 0.5 years. This value is much younger than mean ages inferred from simultaneous and previous observations of SF6 in the Arctic vortex, providing evidence for a mesospheric sink for SF6. The mean age in the midlatitude middle stratosphere (approximately 25-32 km) is nearly constant with respect to altitude at 5 plus or minus 0.5 years. Comparison with earlier balloon observations of CO2 dating back to the 1970s shows that the mean age of air in this region has been relatively invariant over the last 25 years.

Andrews, Arlyn E.↗

Stratospheric Age Spectra and Mean Ages From In Situ Observations of Carbon Dioxide

Tropospheric CO2 mixing ratios exhibit latitudinally varying seasonal and interannual oscillations superimposed on the long-term positive trend due to fossil fuel combustion. In situ observations of CO2 obtained from 1992-2000 using the NASA ER-2 aircraft and high-altitude balloons show that these time-varying signals propagate into the stratosphere, providing information about the transport history of sampled air. We have used these data to derive age spectra and mean ages that can be compared with results from models of the stratospheric circulation. Age spectra have been derived for altitudes below approximately 20 km for the tropics and for northern midlatitudes, where there is sufficient data and where the amplitudes of the seasonal and interannual oscillations are large enough to be detected. The midlatitude CO2 data are consistent with bimodal age spectra, which may result from a subtropical "barrier" to horizontal exchange. Seasonally resolved mean ages are available with nearly pole-to-pole coverage below 20 km and in the tropics and at middle and high northern latitudes up to the maximum altitude reached by the balloons (approximately 30 km). The oldest air sampled was in the Arctic polar vortex with a mean age of 6.5 +/- 0.5 years.

Andrews, Arlyn E.↗

Air, surface, and wastewater surveillance of SARS-CoV-2; a multimodal evaluation of COVID-19 detection in a built environment

Environmental surveillance of infectious organisms holds tremendous promise to reduce human-to-human transmission in indoor spaces through early detection. In this study we determined the applicability and limitations of wastewater, indoor high-touch surfaces, in-room air, and rooftop exhaust air sampling methods for detecting SARS-CoV-2 in a real world building occupied by residents recently diagnosed with COVID-19. We concurrently examined the results of three 24-hour environmental surveillance techniques, indoor surface sampling, exhaust air sampling and wastewater surveillance, to the known daily census fluctuations in a COVID-19 isolation dormitory. Additionally, we assessed the ability of aerosol samplers placed in the large volume lobby to detect SARS-CoV-2 multiple times per day. Our research reveals an increase in the number of individuals confirmed positive with COVID-19 as well as their estimated human viral load to be associated with statistically significant increases in viral loads detected in rooftop exhaust aerosol samples (p = 0.0413), wastewater samples (p = 0.0323,), and indoor high-touch surfaces (p < 0.001)). We also report that the viral load detected in lobby aerosol samples was statistically higher in samples collected during presence of occupants whose COVID-19 diagnostic tests were confirmed positive via qPCR compared to periods when the lobby was occupied by either contact-traced (suspected positive) individuals or during unoccupied periods (p = 0.0314 and <2e–16). We conclude that each daily (24h) surveillance method, rooftop exhaust air, indoor high-touch surfaces, and wastewater, provide useful detection signals for building owner/operator(s). Furthermore, we demonstrate that exhaust air sampling can provide spatially resolved signals based upon ventilation exhaust zones. Additionally, we find that indoor lobby air sampling can provide temporally resolved signals useful during short duration sampling periods (e.g., 2-4 hours) even with intermittent occupancy by occupants diagnosed with COVID-19.

60 APPLIED LIFE SCIENCES↗

Problems Found Using a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion of anthropogenic activity estimates with the relative bias being small compared to the dispersion, indicating that the system would not give false positive indications for an appropriately set decision level. By also measuring environmental air sample filters simultaneously with electroplated alpha filters, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations from calibrated values indicating that the system would give false negative indications. Use of the current algorithm is, therefore, not recommended for general assay applications. Use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve-fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha activities on air sample filters (not due to radon progeny) around the 200 disintegrations per minute level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Use of a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha and beta activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion with the relative bias being small compared to the dispersion. By also measuring environmental air sample filters simultaneously with electroplated alpha and beta sources, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations. Use of the current algorithm is therefore not recommended for assay applications and so use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha and beta activities on air sample filters (not due to radon progeny) around the 200 dpm level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗