Search NASA⌕ Search

SEARCH · Search NASA

Results for “ambient ionization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Pre-Ionization Controlled Laser Plasma Formation for Ignition Applications (Final Scientific/Technical Report)

This report consists of three grand funded papers. Abstracts for each follow. 1) In this work, we present experimental and modeling studies of air pre-ionization using ultraviolet (UV) laser pulses and its effect on laser breakdown of an overlapped near-infrared (NIR) pulse. Experimental studies are conducted with a 266 nm beam (fourth harmonic of Nd:YAG) for UV pre-ionization and an overlapped 1064 nm NIR beam (fundamental of Nd:YAG), both having pulse duration of 10 ns. Results show that the UV beam produces a pre-ionized volume which assists in breakdown of the NIR beam, leading to reduction in NIR breakdown threshold by factor of >2. Numerical modeling is performed to examine the ionization and breakdown of both beams. The modeled breakdown threshold of the NIR, including assist by pre-ionization, is in reasonable agreement with the experimental results. 2) The present contribution compares the energy absorption, optical emission, temperature, and fluid dynamics of ultraviolet (UV) λ = 266 nm and near infrared (NIR) λ = 1064 nm nanosecond laser induced plasmas in ambient air. For UV pulses at the conditions studied, energy absorption by the plasmas increases relatively gradually with laser pulse energy starting at delivered energy of E~8 mJ. Corresponding measurements of plasma luminosity show that the absorption of UV radiation does not necessarily result in visible plasma emission. For the NIR induced plasmas, the energy absorption profile is far more abrupt and begins at ~55 mJ. In contrast with UV, the absorption of NIR radiation is always accompanied by intense optical emission. The temperatures of both types of plasma have been measured with Rayleigh scattering thermometry (at times after the Thomson signal sufficiently diminishes). The UV plasmas can attain a wider range of temperatures, including lower temperatures, depending on the pulse energy (e.g., T ~400–2000K for E ~7–35 mJ at Δt = 10 μs after the pulse) while the NIR plasmas show only hotter temperatures (e.g., T ~ 12 000 K for E = 75 mJ at Δt = 10 μs after the pulse) as is consistent with the literature. Differences in the fluid dynamics for UV versus NIR pulses are shown with Schlieren imaging. In this work, the contrast in the UV and NIR plasma threshold behavior is attributed to differing roles of avalanche ionization and multiphoton ionization as is also illustrated by a simple numerical model. 3) The present contribution examines the impact of plasma dynamics and plasma-driven fluid dynamics on the flame growth of laser ignited mixtures and shows that a new dual-pulse scheme can be used to control the kernel formation process in ways that extend the lean ignition limit. We perform a comparative study between (conventional) single-pulse laser ignition (λ = 1064 nm) and a novel dual-pulse method based on combining an ultraviolet (UV) pre-ionization pulse (λ = 266 nm) with an overlapped near-infrared (NIR) energy addition pulse (λ = 1064 nm). We employ OH* chemiluminescence to visualize the evolution of the early flame kernel. For single-pulse laser ignition at lean conditions, the flame kernel separates through third lobe detachment, corresponding to high strain rates that extinguish the flame. In this work, we investigate the capabilities of the dual-pulse to control the plasma-driven fluid dynamics by adjusting the axial offset of the two focal points. In particular, we find there exists a beam waist offset whereby the resulting vorticity suppresses formation of the third lobe, consequently reducing flame stretch. With this approach, we demonstrate that the dual-pulse method enables reduced flame speeds (at early times), an extended lean limit, increased combustion efficiency, and decreased laser energy requirements.

Mechanical engineering↗

Enhancing characterization of organic nitrogen components in aerosols and droplets using high-resolution aerosol mass spectrometry

This study aims to enhance the understanding and application of the Aerodyne high-resolution aerosol mass spectrometer (HR-AMS) for comprehensive characterization of organic nitrogen (ON) compounds in aerosol particles and atmospheric droplets. To achieve this, we analyzed seventy-five N-containing organic compounds, representing a diverse range of ambient ON types, including amines, amides, amino acids, N-heterocycles, protein, and humic acids. Our results show that ON compounds can produce significant levels of NH x + and NO x + ion fragments, which are typically recognized as ions representative of inorganic nitrogen species. We also discovered the presence of CH 2 N + at m/z = 28.0187, an ion fragment that is rarely quantified in ambient datasets due to substantial interference from air-related N 2 + . As a result, we determined that an updated calibration factor of 0.79 is necessary to accurately quantify ON content using aerosol mass spectrometry. We also assessed the relative ionization efficiencies (RIEs) for different ON species and found that the average RIE of ON compounds (1.52 ± 0.58) aligns with the commonly used default value of 1.40 for organic aerosol (OA). Moreover, through a careful examination of the HR-AMS mass spectral features of various ON types, we propose fingerprint ion series that can aid the ON speciation analysis. The presence of C n H 2n+2 N + ions is closely linked with amines, with CH 4 N + indicating primary amines, C 2 H 6 N + suggesting secondary amines, and C 3 H 8 N + representing tertiary amines. C n H 2n NO + ions (especially for n values of 1–4) are very likely derived from amides. The co-existence of three ions, C 2 H 4 NO 2 + , C 2 H 3 NO + , and CH 4 NO + , serves as an indicator for the presence of amino acids. Additionally, the presence of C x H y N 2 + ions indicates the occurrence of 2N-heterocyclic compounds. Notably, an elevated abundance of NH 4 + is a distinct signature for amines and amino acids, as inorganic ammonium salts produce only negligible amounts of NH 4 + in HR-AMS. Finally, we quantified the ON contents in submicron particles (PM 1 ) and fog waters in Fresno, California and PM 1 in New York City (NYC). Our results revealed the substantial presence of amino compounds in both Fresno and NYC aerosols, whereas concurrently collected fog waters contained a broader range of ON species, including N-containing aromatic heterocycle (e.g., imidazoles) and amides. These findings highlight the significant potential of employing the widespread HR-AMS measurements of ambient aerosols and droplets to enhance our understanding of the sources, transformation processes, and environmental impacts associated with ON compounds in the atmosphere.

54 ENVIRONMENTAL SCIENCES↗

Ch3MS-RF: a random forest model for chemical characterization and improved quantification of unidentified atmospheric organics detected by chromatography–mass spectrometry techniques

Abstract. The chemical composition of ambient organic aerosols plays a critical role in driving their climate and health-relevant properties and holds important clues to the sources and formation mechanisms of secondary aerosol material. In most ambient atmospheric environments, this composition remains incompletely characterized, with the number of identifiable species consistently outnumbered by those that have no mass spectral matches in the literature or the National Institute of Standards and Technology/National Institutes of Health/Environmental Protection Agency (NIST/NIH/EPA) mass spectral databases, making them nearly impossible to definitively identify. This creates significant challenges in utilizing the full analytical capabilities of techniques which separate and generate spectra for complex environmental samples. In this work, we develop the use of machine learning techniques to quantify and characterize novel, or unidentifiable, organic material. This work introduces Ch3MS-RF (Chemical Characterization by Chromatography–Mass Spectrometry Random Forest Modeling), an open-source, R-based software tool, for efficient machine-learning-enabled characterization of compounds separated in chromatography–mass spectrometry applications but not identifiable by comparison to mass spectral databases. A random forest model is trained and tested on a known 130 component representative external standard to predict the response factors of novel environmental organics based on position in volatility–polarity space and mass spectrum, enabling the reproducible, efficient, and optimized quantification of novel environmental species. Quantification accuracy on a reserved 20 % test set randomly split from the external standard compound list indicates that random forest modeling significantly outperforms the commonly used methods in both precision and accuracy, with a median response factor percent error of −2 %, for modeled response factors, compared to > 15 %, for typically used proxy assignment-based methods. Chemical properties modeling, evaluated on the same reserved 20 % test set and an extrapolation set of species identified in ambient organic aerosol samples collected in the Amazon rainforest, also demonstrate robust performance. Extrapolation set property prediction mean absolute errors for carbon number, oxygen to carbon ratio (O : C), average carbon oxidation state (OSc‾), and vapor pressure are 1.8, 0.15, 0.25, and 1.0 (log(atm)), respectively. Extrapolation set out-of-sample R2 for all properties modeled are above 0.75, with the exception of vapor pressure. While predictive performance for vapor pressure is less robust compared to the other chemical properties modeled, random-forest-based modeling was significantly more accurate than other commonly used methods of vapor pressure prediction, decreasing the mean vapor pressure prediction error to 0.24 (log(atm)) from 0.55 (log(atm)) (chromatography-based vapor pressure prediction) and 1.2 (log(atm)) (chemical formula-based vapor pressure prediction). The random forest model significantly advances an untargeted analysis of the full scope of chemical speciation yielded by two-dimensional gas chromatography (GCxGC-MS) techniques and can be applied to gas chromatography coupled with electron ionization mass spectrometry (GC-MS) as well. It enables the accurate estimation of key chemical properties commonly utilized in the atmospheric chemistry community, which may be used to more efficiently identify important tracers for further individual analysis and to characterize compound populations uniquely formed under specific ambient conditions.

54 ENVIRONMENTAL SCIENCES↗

Atmospheric-pressure ionization and fragmentation of molecules for structural elucidation

A solution-cathode glow discharge (SCGD) spectrometry apparatus may comprise an SCGD source and a mass or ion mobility spectrometer. A method for ionizing a molecular analyte may comprise contacting the molecular analyte with a plasma discharge to form ions and separating the ions in a mass spectrometer or ion mobility spectrometer. The contacting step may occur under atmospheric pressure and/or ambient conditions. The molecular analyte may be fragmented by the plasma discharge.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-shot ultrafast dynamics of nanosecond pulsed plasmas: Transition from ps–ns nonequilibrium to near-full ionization

The ultrafast multi-stage evolution of state-defining properties in atmospheric-pressure nanosecond pulsed plasmas is quantified using single-discharge, jitter-free, continuous streak-sweep spectroscopy of N 2 (C → B) molecular and N + /O + ionic species with a single-shot time resolution as short as ∼160 ps. An early period of extreme nonequilibrium is observed with vibrational temperatures [T V (C)] dropping from ∼8000 K at <200 ps after plasma breakdown to <4000 K within ∼1 ns, with near-ambient rotational temperatures [T R (C)] ∼ 300 K due to limited collisional energy transfer. This early-time T V (C) trend is representative of a direct and unquenched look into the high-energy tail of the electron energy distribution function; thus, it tracks real-time changes in the mean electron energy via the N2(C) emission signatures. This is followed by the rapid onset of N + /O + ionic emission after a distinct time delay of ∼14.9 ns due to multistep chemical kinetics. The ionic emission enables determination of electron densities (n e ) >2 × 10 19 cm −3 and electron temperatures (T e ) >36 000 K, indicating the transition to a nearly fully ionized regime. The ps–ns temporal dynamics are also compared between air and N 2 plasmas to assess the influence of collisional partners, as well as across the anode, cathode, and central gap regions to identify spatial variations in plasma behavior. Finally, this work demonstrates versatile continuously probing approach capable of spectro-temporal and spatially resolved single-shot measurements of key state variables in the ps–ns evolution of atmospheric-pressure nanosecond pulsed plasmas.

Electric discharges↗

Trapped Electrons and Ions as Particle Detectors

Electrons and ions trapped with electromagnetic fields have long served as important high-precision metrological instruments, and more recently have also been proposed as a platform for quantum information processing. Here we point out that these systems can also be used as highly sensitive detectors of passing charged particles, due to the combination of their extreme charge-to-mass ratio and low-noise quantum readout and control. In particular, these systems can be used to detect energy depositions many orders of magnitude below typical ionization scales. As illustrations, we suggest some applications in particle physics. We outline a nondestructive time-of-flight measurement capable of sub-eV energy resolution for slowly moving, collimated particles. We also show that current devices can be used to provide competitive sensitivity to models where ambient dark matter particles carry small electric millicharges $\ll$e. Furthermore, our calculations may also be useful in the characterization of noise in quantum computers coming from backgrounds of charged particles.

47 OTHER INSTRUMENTATION↗

Impact of Glass Irradiation on Laser-Induced Breakdown Spectroscopy Data Analysis

Increased absorption of optical materials arising from exposure to ionizing radiation must be accounted for to accurately analyze laser-induced breakdown spectroscopy (LIBS) data retrieved from high-radiation environments. We evaluate this effect on two examples that mimic the diagnostics placed within novel nuclear reactor designs. The analysis is performed on LIBS data measured with 1% Xe gas in an ambient He environment and 1% Eu in a molten LiCl-KCl matrix, along with the measured optical absorption from the gamma- and neutron-irradiated low-OH fused silica and sapphire glasses. Significant changes in the number of laser shots required to reach a 3σ detection level are observed for the Eu data, increasing by two orders of magnitude after exposure to a 1.7 × 1017 n/cm2 neutron fluence. For all cases examined, the spectral dependence of absorption results in the introduction of systematic errors. Moreover, if lines from different spectral regions are used to create Boltzmann plots, this attenuation leads to statistically significant changes in the temperatures calculated from the Xe II lines and Eu II lines, lowering them from 8000 ± 610 K to 6900 ± 810 K and from 15,800 ± 400 K to 7200 ± 800 K, respectively, for exposure to the 1.7 × 1017 n/cm2 fluence. The temperature range required for a 95% confidence interval for the calculated temperature is also broadened. In the case of measuring the Xe spectrum, these effects may be mitigated using only the longer-wavelength spectral region, where radiation attenuation is relatively small, or through analysis using the iterative Saha–Boltzmann method.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Pellet sublimation and expansion under runaway electron flux

This work provides a qualitative description of the pellet response to the ambient runaway electrons. For ITER-relevant parameters, our estimates suggest that the cryogenic pellets will be sublimated instantly at the edge of the runaway beam. The subsequent rapid expansion of the sublimated material spreads the impurities over the poloidal cross-section of a tokamak on a millisecond time scale prior to the complete ionization of the expanding cloud. Here, the injected solid pellet turns into a rapidly expanding gas cloud before it reaches the core of the runaway beam. As a result, the pellet acts similar to the massive gas injection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Capability Demonstration of a 3D CdZnTe Detector on a High-Altitude Balloon Flight

In collaboration between the University of Michigan and Los Alamos National Laboratory, a 3D position-sensing CdZnTe (CZT) detector prototype was built and integrated into a high-altitude balloon platform to evaluate its performance in a space-like mixed-radiation environment. The detector prototype, Orion Eagle, was designed to operate in near-vacuum environments without any temperature regulation. Orion Eagle was hand-launched from NASA’s Columbia Scientific Balloon Facility (CSBF) at Fort Sumner, NM on September 26, 2021, and successfully operated throughout a 9-hour flight, which reached 38.5 km in altitude. The flight met its objectives, successfully detecting atmospheric gamma rays and galactic cosmic rays, and raising the Technical Readiness Level from 4 to 6 for large-volume 3D CZT detector technology for space applications. Ionization tracks produced by charged particles create spatial signatures in the detector that are distinguishable from discrete gamma-ray interactions. Therefore, the 3D position-sensing capabilities using pixelated electrodes on a CZT detector can help enable discrimination of background charged particles from gamma-ray events without an anticoincidence shield. The potential for background rejection capability, ambient-temperature operation, gamma-ray coded-aperture and Compton imaging, and near High Purity Germanium (HPGe) energy resolution motivate the use of large-volume 3D CZT imaging spectrometers in future space missions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of Glass Irradiation on Laser-induced Breakdown Spectroscopy Diagnostics in the Visible and NIR Range

Increased absorption of optical materials arising from the exposure to ionizing radiation must be accounted for to accurately analyze the laser-induced breakdown spectroscopy (LIBS) data retrieved from high-radiation environments. We evaluate this effect on a specifc example that mimics the diagnostics placed within a gas-cooled fast reactor coolant stream. Analysis is performed on the LIBS data measured with 1% Xe gas in an ambient He environment and the measured optical absorption from the gamma- and neutron-irradiated low-OH fused silica and sapphire glasses. No significant change in the number of shots required to reach a 3σ detection level was observed up to 10 Mrad gamma dose and exposure to a 1.7×10 17 n/cm 2 neutron fluence. In contrast, the spectral dependence of absorption results in either a systematic overestimation or underestimation of line intensity ratios, depending on the line of interest selected for analysis. Moreover, if lines from different spectral regions are used to create Boltzmann plots, this attenuation also leads to statistically significant changes in the calculated temperatures for calculations using Xe II lines only, lowering them from 8000±610 K to 6800±810 K for the case of exposure to the 1.7×10 17 n/cm 2 flux, and broadening the temperature range required for a 95% confidence interval. In the case of measuring the Xe spectrum, these effects may be mitigated using only the longer-wavelength spectral region, where radiation-attenuation is relatively small, or through analysis using the iterative Saha-Boltzmann method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ambient Ion Trapping and Separations for High Throughput Structurally Selective Material Deposition

While ion mobility coupled to mass spectrometry (IMS/MS) has been increasingly adapted to biological analysis, the structural and molecular specificity offered by IMS/MS has untapped potential for creating novel materials (for energy, catalysis, biomolecular switches etc.) with rationally tailored properties by precisely controlling the chemical structure and composition of these materials. While electrochemical and catalytic properties of the bulk material are understood by mass-selective ion-soft-landing, different structures of one molecule can exhibit distinct properties from the bulk. Many biological phenomenon occur at interfaces and are highly structurally specific. IMS/MS offers means to separate molecules in a sample (which is first ionized and released to gas phase from the condensed phase) based on mass and structure. Species thus separated can potentially be deposited onto surfaces with molecular and structural specificity, to perform fundamental investigations for understanding critical interfacial phenomenon. Key performance metrics for IMS/MS analysis are resolution of separations and sensitivity. Recently developed Structures for Lossless Ion Manipulations (SLIM)4 enabled unprecedented resolution in IMS separations. In addition, high sensitivity was enabled in SLIM due to lossless confinement of ions using radio frequency fields. Thus, SLIM enabled extremely long path length separations (up to 0.1 km thus far) providing efficient separation of molecular ions never before achieved (e.g. isotopologues, D&L amino acids). While SLIM has unprecedented analytical separations power/utility, the use of SLIM platform for depositing mobility and mass selected molecular ions has two specific technological challenges: (a) Pulsed nature of IMS separations and their low duty cycle and (b) the need for a low vacuum of ~4 torr for lossless ion confinement. These limitations lead to long deposition times due to loss of ions generated from the sample. Enabling ion confinement at atmospheric pressure will be path-breaking contribution to the fundamental understanding of ion manipulations and separations and will also enable novel science currently precluded due to the inability of the present technologies to confine ions under ambient conditions. Traditionally used radio frequency fields are ineffective in confining ions at high pressures due to ion/neutral collisions. To address these, we propose to (a) develop methods for confining and manipulating ions for lossless IMS separations at atmospheric pressure enabling high sensitivity and throughput and (b) use the high specificity of IMS/MS and high throughput from ambient ion confinement to perform mobility and mass selective ion deposition at atmospheric pressure. Our goal is to enable the study of the fundamental properties of energy/catalysis materials and biomolecules. This project paves the way for high-throughput, mass and structure selective material deposition for highly specific surface creation/functionalization (discussed in Section 2 of the report). Further, the developments reported continue to push the boundaries of this process to ambient conditions (discussed in Section 3 of the report). We conclude with a list of specific intellectual property and publications which have been the outcome of this funded project.

36 MATERIALS SCIENCE↗

Nanoscale Mass Spectrometry Multimodal Imaging via Tip-Enhanced Photothermal Desorption

Materials ranging from adhesives, pharmaceuticals, lubricants, and personal care products are traditionally studied using macroscopic characterization techniques. However, their functionality is in reality defined by details of chemical organization on often noncrystalline matter with characteristic length scales on the order of microns to nanometers. Additionally, these materials are traditionally difficult to analyze using standard vacuum-based approaches that provide nanoscale chemical characterization due to their volatile and beam-sensitive nature. Therefore, approaches that operate under ambient conditions need to be developed that allow probing of nanoscale chemical phenomena and correlated functionality. Here, we demonstrate a tool for probing and visualizing local chemical environments and correlating them to material structure and functionality using advanced multimodal chemical imaging on a combined atomic force microscopy (AFM) and mass spectrometry (MS) system using tip-enhanced photothermal desorption with atmospheric pressure chemical ionization (APCI). We demonstrate enhanced performance metrics of the technique for correlated imaging and point sampling and illustrate the applicability for the analysis of trace chemicals on a human hair, additives in adhesives on paper, and pharmaceuticals samples notoriously difficult to analyze in a vacuum environment. Overall, this approach of correlating local chemical environments to structure and functionality is key to advancing research in many fields ranging from biology, to medicine, to material science.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Attosecond-pump attosecond-probe x-ray spectroscopy of liquid water

Attosecond-pump/attosecond-probe experiments have long been sought as the most straightforward method for observing electron dynamics in real time. Although there has been much success with overlapped near-infrared femtosecond and extreme ultraviolet attosecond pulses combined with theory, true attosecond-pump/attosecond-probe experiments have been limited. Here we used a synchronized attosecond x-ray pulse pair from an x-ray free-electron laser to study the electronic response to valence ionization in liquid water through all x-ray attosecond transient absorption spectroscopy (AX-ATAS). Our analysis showed that the AX-ATAS response is confined to the subfemtosecond timescale, eliminating any hydrogen atom motion and demonstrating experimentally that the 1b 1 splitting in the x-ray emission spectrum is related to dynamics and is not evidence of two structural motifs in ambient liquid water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiation-induced dry reforming: A negative emission process

The reaction between the most abundant greenhouse gases (GHG) to produce hydrogen might represent the most powerful and effective decarbonizing opportunity, if a low-carbon energy source is used to drive it. This is the case of methane (CH 4 ) dry reforming (MDR) where its reaction with carbon dioxide (CO 2 ) produces synthesis gas (syngas, a mixture of carbon monoxide and hydrogen). Here this study explores the feasibility of using ionizing radiation to induce the MDR reaction, at low temperatures and/or less energy demanding conditions. Additionally, the ionizing radiation is proposed to be supplied by nuclear power plants (NPPs), which are low-carbon reliable energy generation sources. Thus, the radiolysis of CO 2 , CH 4 and their mixtures, under ?-irradiation was evaluated in the absence and presence of nickel catalysts. The radiation-induced MDR reaction and radiation-induced catalytic promotion were proven to take place at temperatures close to ambient though at low conversion, with yields below 1%. Since irradiation and heat can be provided by a nuclear power plant, this radiation-induced reaction establishes a connection between nuclear energy to renewable resources and enables a pathway for a decarbonized cleaner chemical industry, for producing green chemicals.

08 HYDROGEN↗

Design, Synthesis, and Characterization of Polymer Precursors to Li x PON and Li x SiPON Glasses: Materials That Enable All-Solid-State Batteries (ASBs)

LiPON-like glasses that form lithium dendrite impenetrable interfaces between lithium battery components are enabling materials that may replace liquid electrolytes permitting production of all-solid-state batteries (ASBs). Unfortunately, to date, such materials are introduced only via gas-phase deposition. Furthermore, we demonstrate the design and synthesis of easily scaled, lowtemperature, low-cost, solution-processable inorganic polymers containing LiPON/LiSiPON elements. OPCl 3 and hexachlorophosphazene [Cl 2 P=N] 3 provide starting points for elaboration using MNH 2 (M = Li/Na) or (Me 3 Si)NH followed by reaction with controlled amounts of LiNH 2 to produce oligomers/polymers with molecular weights (MWs) ≈1–2 kDa characterized by multinuclear NMR, gel permeation chromatography (GPC), thermogravimetric analysis (TGA), Fourier-transform infrared (FTIR), X-ray powder diffraction (XRD), X-ray photoelectron spectroscopy (XPS), and matrix-assisted laser desorption/ ionization (MALDI)-time-of-flight (ToF) offering stabilities to 150–200 °C and ceramic yields (800 °C) of 50–60%. 7 Li NMR suggests that precursor-bound Li + dissociates easily, beneficial for electrochemical applications. XPS shows higher N/P ratios (1–3) than via gas-phase methods (<1) correlating N/P ratios, 7 Li shifts, and Li + conductivities. Li 2 SiPHN offers the highest ambient conductivity of 3 × 10 –1 mS cm –1 at 400 °C/2 h/N 2 .

36 MATERIALS SCIENCE↗

Measurement of correlated charge noise in superconducting qubits at an underground facility

The charge environment of superconducting qubits may be studied through the introduction of controlled, quantified amounts of ionizing radiation. We measure space- and time-correlated charge jumps on a four-qubit device, operating 107 meters below the Earth’s surface in a low-radiation, cryogenic facility designed for the characterization of low-threshold particle detectors. The rock overburden of this facility reduces the cosmic ray muon flux by over 99% compared to laboratories at sea level. Combined with 4π coverage of a movable lead shield, this facility enables quantifiable control over the flux of ionizing radiation on the qubit device. Long-time-series charge tomography measurements on these weakly charge-sensitive qubits capture discontinuous jumps in the induced charge on the qubit islands, corresponding to the interaction of ionizing radiation with the qubit substrate. The rate of these charge jumps scales with the flux of ionizing radiation on the qubit package, as characterized by a series of independent measurements on another energy-resolving detector operating simultaneously in the same cryostat with the qubits. Using lead shielding, we achieve a minimum charge jump rate of $0.19^{+0.04}_{-0.03}$ mHz, almost an order of magnitude lower than that measured in surface tests, but a factor of roughly seven higher than expected based on reduction of ambient gammas alone. We operate four qubits for over 22 consecutive hours with zero correlated charge jumps at length scales above three millimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ionizing Radiation Sensing with Functionalized and Copper-Coated SWCNT/PMMA Thin Film Nanocomposites

This paper studies the ionizing radiation effects on functionalized single-walled carbon nanotube (SWCNT)/poly(methyl methacrylate) (PMMA) thin-film nanocomposites [SWNT/PMMA]. The functionalized thin-film devices are made of ferrocene-doped SWCNTs, SWCNTs functionalized with carboxylic acid (COOH), and SWCNTs coated/ modified with copper. The nanocomposite was synthesized by the solution blending method and the resulting nanocomposite was spin-cast on interdigitated electrodes (IDEs). A 160 kV X-ray source was used to irradiate the thin film and changes in the electrical resistance of the nanocomposites due to X-rays were measured using a semiconductor device analyzer. Carboxylic acid functionalized and copper-coated SWCNT/PMMA nanocomposite showed a reduced response to X-rays compared to unfunctionalized SWCNT/PMMA nanocomposite. Ferrocene-doped SWCNT showed a higher sensitivity to X-rays at lower dose rates. This is in contrast to a previous study that showed that similar nanocomposites using functionalized multi-walled CNTs (MWCNTs) had demonstrated an improved response to X-rays ionizing radiation compared to unfunctionalized MWCNTs for all dose rates. Electrical measurements were also performed using the Arduino Nano microcontroller. The result showed that a relatively economical, lightweight-designed prototype radiation sensor based on SWCNT/PMMA thin-film devices could be produced by interfacing the devices with a modest microcontroller. This work also shows that by encapsulating the SWCNT/PMMA thin-film device in a plastic container, the effect of ambient humidity can be reduced and the device can still be used to detect X-ray radiation. This study further shows that the sensitivity of SWCNT to X-rays was dependent on both the functionalization of the SWCNT and the dose rate.

36 MATERIALS SCIENCE↗

Transient Pulse-Response Time-of-Flight Mass Spectrometry for Complex, Deactivating Heterogeneous Catalytic Systems: Application to Ethane Dehydroaromatization

The study of complex, multistep bond-forming and -breaking reactions in heterogeneous catalytic systems often encounters challenges associated with the involvement of large numbers of intermediates among branching pathways. Kinetic information obtained from traditional steady-state measurements can be complemented with that from time-resolved methods to uncover details of the underlying chemistry. Herein, we describe an approach for tracking the complete time-resolved chemical composition (ca. 4–200 u) of a reactor effluent in response to a reactant pulse. We use a six-port rotary valve with a metered sampling loop to pulse reactants at ambient pressure into a flow reactor packed with a catalyst bed within the isothermal region of a heated furnace. The temporal evolution of effluent species is tracked using time-resolved molecular-beam time-of-flight mass spectrometry. We highlight the possibilities that this method has to offer by studying the complex bifunctional mechanism of ethane dehydroaromatization over an HZSM-5-supported platinum catalyst. We demonstrate that energy-tunable ionization sources, which facilitate isomer resolution, enable the measurement of the full mass spectral time-dependent system response. This includes the evolution of major products and mechanistically relevant reactive intermediates such as 1,3-butadiene and cyclopentadiene; these species have not previously been observed from this reaction. In additional studies, we also assess the role of platinum in the catalyst by examining temporal responses to ethane and ethylene feeds. Results show that two temporally distinct formation pathways exist for methane and benzene, and that their importance depends on both catalyst composition and reactant identity. Additionally, characteristics of catalyst deactivation are uniquely observable in the time-resolved mass spectral response, including the selective deactivation of a benzene formation pathway. The combination of time-of-flight mass spectrometry with tunable ionization enables the simultaneous observation of all effluents in a complex mixture of intermediates with isomer/isobar differentiation capabilities that can be applied to any complex reaction system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗