Search NASA⌕ Search

SEARCH · Search NASA

Results for “antiparticles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

65 records · Page 4

Opportunities in cosmic-ray physics and astrophysics

The Board on Physics and Astronomy of the National Research Council established the Committee on Cosmic-Ray Physics to prepare a review of the field that addresses both experimental and theoretical aspects of the origin of cosmic radiation from outside the heliosphere. The following recommendations are made: NASA should provide the opportunity to measure cosmic-ray electrons, positrons, ultraheavy nuclei, isotopes, and antiparticles in space; NASA, the National Science Foundation (NSF), and the Department of Energy (DOE) should facilitate direct and indirect measurement of the elemental composition to as high an energy as possible, for which the support of long-duration ballooning and hybrid ground arrays will be needed; NSF and DOE should support the new Fly's Eye and provide for U.S. participation in the big projects on the horizon, which include giant arrays, ground-based gamma-ray astronomy, and neutrino telescopes; and NASA, NSF, and DOE should support a strong program of relevant theoretical investigations.

Source record↗

A Scintillation Counter System Design To Detect Antiproton Annihilation using the High Performance Antiproton Trap(HiPAT)

The High Performance Antiproton Trap (HiPAT), a system designed to hold up to l0(exp 12) charge particles with a storage half-life of approximately 18 days, is a tool to support basic antimatter research. NASA's interest stems from the energy density represented by the annihilation of matter with antimatter, 10(exp 2)MJ/g. The HiPAT is configured with a Penning-Malmberg style electromagnetic confinement region with field strengths up to 4 Tesla, and 20kV. To date a series of normal matter experiments, using positive and negative ions, have been performed evaluating the designs performance prior to operations with antiprotons. The primary methods of detecting and monitoring stored normal matter ions and antiprotons within the trap includes a destructive extraction technique that makes use of a micro channel plate (MCP) device and a non-destractive radio frequency scheme tuned to key particle frequencies. However, an independent means of detecting stored antiprotons is possible by making use of the actual annihilation products as a unique indicator. The immediate yield of the annihilation event includes photons and pie mesons, emanating spherically from the point of annihilation. To "count" these events, a hardware system of scintillators, discriminators, coincident meters and multi channel scalars (MCS) have been configured to surround much of the HiPAT. Signal coincidence with voting logic is an essential part of this system, necessary to weed out the single cosmic ray events from the multi-particle annihilation shower. This system can be operated in a variety of modes accommodating various conditions. The first is a low-speed sampling interval that monitors the background loss or "evaporation" rate of antiprotons held in the trap during long storage periods; provides an independent method of validating particle lifetimes. The second is a high-speed sample rate accumulating information on a microseconds time-scale; useful when trapped antiparticles are extracted against a target, providing an indication of quantity. This paper details the layout of this system, setup of the hardware components around HiPAT, and applicable checkouts using normal matter radioactive sources.

Martin, James J.↗

Radio-Frequency Plasma Cleaning of a Penning Malmberg Trap

Radio-frequency-generated plasma has been demonstrated to be a promising means of cleaning the interior surfaces of a Penning-Malmberg trap that is used in experiments on the confinement of antimatter. {Such a trap was reported in Modified Penning-Malmberg Trap for Storing Antiprotons (MFS-31780), NASA Tech Briefs, Vol. 29, No. 3 (March 2005), page 66.} Cleaning of the interior surfaces is necessary to minimize numbers of contaminant atoms and molecules, which reduce confinement times by engaging in matter/antimatter-annihilation reactions with confined antimatter particles. A modified Penning-Malmberg trap like the one described in the cited prior article includes several collinear ring electrodes (some of which are segmented) inside a tubular vacuum chamber, as illustrated in Figure 1. During operation of the trap, a small cloud of charged antiparticles (e.g., antiprotons or positrons) is confined to a spheroidal central region by means of a magnetic field in combination with DC and radiofrequency (RF) electric fields applied via the electrodes. In the present developmental method of cleaning by use of RF-generated plasma, one evacuates the vacuum chamber, backfills the chamber with hydrogen at a suitable low pressure, and uses an RF-signal generator and baluns to apply RF voltages to the ring electrodes. Each ring is excited in the polarity opposite that of the adjacent ring. The electric field generated by the RF signal creates a discharge in the low-pressure gas. The RF power and gas pressure are adjusted so that the plasma generated in the discharge (see Figure 2) physically and chemically attacks any solid, liquid, and gaseous contaminant layers on the electrode surfaces. The products of the physical and chemical cleaning reactions are gaseous and are removed by the vacuum pumps.

Sims, William Herbert, III↗

Positron Interactions with Atoms and Ions

Dirac, in 1928, combining the ideas of quantum mechanics and the ideas of relativity invented the well-known relativistic wave equation. In his formulation, he predicted an antiparticle of the electron of spin n-bar/2. He thought that this particle must be a proton. Dirac published his interpretation in a paper 'A theory of electrons and protons.' It was shown later by the mathematician Hermann Weyl that the Dirac theory was completely symmetric between negative and positive particles and the positive particle must have the same mass as that of the electron. In his J. Robert Oppenheimer Memorial Prize Acceptance Speech, Dirac notes that 'Blackett was really the first person to obtain hard evidence for the existence of a positron but he was afraid to publish it. He wanted confirmation, he was really over cautious.' Positron, produced by the collision of cosmic rays in a cloud chamber, was detected experimentally by Anderson in 1932. His paper was published in Physical Review in 1933. The concept of the positron and its detection were the important discoveries of the 20th century. I have tried to discuss various processes involving interactions of positrons with atoms and ions. This includes scattering, bound states and resonances. It has not been possible to include the enormous work which has been carried out during the last 40 or 50 years in theory and measurements.

Bhatia, Anand K.↗

Proton Scattering in NOvA Test Beam

The NuMI Off-axis $\nu_e$ Appearance (NOvA) experiment is a two-detector, long baseline, neutrino oscillation experiment, which aims to make a determination of the neutrino mass ordering, the octant of $\theta_{23}$, and measure possible charge-parity (CP) violation. Determining these parameters is a step towards answering some of the fundamental questions about neutrinos. Are neutrinos their own antiparticle? Could neutrinos be responsible for the matter-antimatter asymmetry of the universe? How do neutrinos get their mass? Answering these questions requires precise measurements of the parameters that govern how neutrinos behave, namely the mass squared splittings, mixing angles, and possible CP-violating phase factor in the PNMS matrix. Reaching high precision requires minimizing both statistical and systematic errors. As NOvA continues to accumulate data, the sizes of our statistical errors continue to shrink such that in a couple of years they will be comparable to our systematic errors. NOvA's current systematic errors are dominated by energy and calibration uncertainties. The Test Beam program was initiated to address these uncertainties by assessing the detector response in an environment where more parameters of the incoming particles are known. One of the main goals of the Test Beam program is to garner a better understanding of our systematic errors, particularly in energy measurement and detector response, so that the modeling of these parameters can be improved. I studied protons in the Test Beam Detector with momenta around \unit[1]{GeV/c}, the high end of the momentum range relevant to quasielastic neutrino interactions in NOvA. One question this sample can help to answer is if we correctly simulate the fraction of protons that have an inelastic scattering interaction versus ranging out. If protons inelastically scatter at different rates in our simulation and data, the correction applied to the hadronic system when reconstructing neutrino energy could be inaccurate, since events with inelastic scattering will have less visible energy in the detector. This is particularly important for quasielastic $\nu_\mu$ events, which have the lowest hadronic energy resolution, and therefore give us our best measurements of $\Delta m_{32}^2$ and $\theta_{23}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulations, Modeling and Data Analysis of Parity Violating Electron Scattering Experiments

In the Standard Model (SM) of nuclear and particle physics, parity violation is incorporated through the representation of the weak interaction as a chiral gauge interaction. Only the left-handed components of particles and right-handed components of antiparticles participate in weak interactions in the Standard Model. This implies that parity is asymmetric for the weak interaction. Parity violating electron scattering (PVES) experiments are designed to probe the physics parameters related to the SM, with the possibility to discover physics beyond the SM (BSM) by measuring the parity violating asymmetry ¿¿¿ of longitudinally polarized electrons scattered off unpolarized targets with high precision. This dissertation will be focused on two PVES experiments, the next 208Pb Lead Radius Experiment (PREX-II), and the Measurement of a Lepton-Lepton Electroweak Reaction (MOLLER) experiment, as well as in some small sections, the Calcium Radius Experiment (CREX) and P2 experiment which are also PVES experiments). PREX-II and CREX experiments, performed in Hall A at the Thomas Jefferson National Accelerator Facility (Jefferson Lab), measured ¿¿¿ in the elastic scattering of longitudinally polarized electrons from 208Pb and 48Ca targets to provide a precise model independent determination of the neutron skin thickness of 208Pb and 48Ca nuclei, respectively. The MOLLER experiment, proposed to start in 2027 and also to be performed in Hall A at Jefferson Lab, is to measure ¿¿¿ of longitudinally polarized electrons scattered off unpolarized electrons (Møller scattering) to determine the weak charge of electrons ¿¿¿ and the weak mixing angle ¿¿ with high precision. As for the P2 experiment, which will be performed at the upcoming MESA accelerator in Mainz Germany, it is to measure the weak charge of proton ¿¿¿ using ¿¿¿ in the elastic electron-proton scattering of polarized electrons off unpolarized protons. The final results from the PREX-II experiment are presented as ¿¿¿=550±16 (¿¿¿¿)±8 (¿¿¿¿) parts-per-billion (ppb). Combining the PREX-I and PREX-II results, the neutron skin thickness from PREX experiments is determined as ¿¿-¿¿=0.283±0.071 ¿¿ in 208Pb. This thesis lists the software and computational contribution of the author to these PVES experiments, including writing scripts and software to help with the PREX-II/CREX experiments, analyzing data to provide useful information and systematic uncertainty for the PREX-II experiment, modeling and simulations for the MOLLER, and providing an alternative design of an electronic equipment for the P2 experiment.

Chen, Yufan↗

Simulations, Modeling and Data Analysis of Parity Violating Electron Scattering Experiments

In the Standard Model (SM) of nuclear and particle physics, parity violation is incorporated through the representation of the weak interaction as a chiral gauge interaction. Only the left-handed components of particles and right-handed components of antiparticles participate in weak interactions in the Standard Model. This implies that parity is asymmetric for the weak interaction. Parity violating electron scattering (PVES) experiments are designed to probe the physics parameters related to the SM, with the possibility to discover physics beyond the SM (BSM) by measuring the parity violating asymmetry ¿¿¿ of longitudinally polarized electrons scattered off unpolarized targets with high precision. This dissertation will be focused on two PVES experiments, the next 208Pb Lead Radius Experiment (PREX-II), and the Measurement of a Lepton-Lepton Electroweak Reaction (MOLLER) experiment, as well as in some small sections, the Calcium Radius Experiment (CREX) and P2 experiment which are also PVES experiments). PREX-II and CREX experiments, performed in Hall A at the Thomas Jefferson National Accelerator Facility (Jefferson Lab), measured ¿¿¿ in the elastic scattering of longitudinally polarized electrons from 208Pb and 48Ca targets to provide a precise model independent determination of the neutron skin thickness of 208Pb and 48Ca nuclei, respectively. The MOLLER experiment, proposed to start in 2027 and also to be performed in Hall A at Jefferson Lab, is to measure ¿¿¿ of longitudinally polarized electrons scattered off unpolarized electrons (Møller scattering) to determine the weak charge of electrons ¿¿¿ and the weak mixing angle ¿¿ with high precision. As for the P2 experiment, which will be performed at the upcoming MESA accelerator in Mainz Germany, it is to measure the weak charge of proton ¿¿¿ using ¿¿¿ in the elastic electron-proton scattering of polarized electrons off unpolarized protons. The final results from the PREX-II experiment are presented as ¿¿¿=550±16 (¿¿¿¿)±8 (¿¿¿¿) parts-per-billion (ppb). Combining the PREX-I and PREX-II results, the neutron skin thickness from PREX experiments is determined as ¿¿-¿¿=0.283±0.071 ¿¿ in 208Pb. This thesis lists the software and computational contribution of the author to these PVES experiments, including writing scripts and software to help with the PREX-II/CREX experiments, analyzing data to provide useful information and systematic uncertainty for the PREX-II experiment, modeling and simulations for the MOLLER, and providing an alternative design of an electronic equipment for the P2 experiment.

Chen, Yufan↗

Antihelium-3 sensitivity for the GRAMS experiment

The Gamma-Ray and AntiMatter Survey (GRAMS) is a next-generation balloon/satellite mission utilizing a Liquid Argon Time Projection Chamber (LArTPC) detector to measure both MeV gamma rays and antinuclei produced by dark matter annihilation or decay. The GRAMS can identify antihelium-3 events based on the measurements of X-rays and charged pions from the decay of the exotic atoms, Time of Flight (TOF), energy deposition, and stopping range. This paper shows the antihelium-3 sensitivity estimation using a GEANT4 Monte Carlo simulation. For the proposed long-duration balloon (LDB) flight program (35 days x 3 flights) and future satellite mission (2-year observation/10-year observation), the sensitivities become 1.47 × 10 −7 [m 2 s sr GeV/n] −1 and 1.55 × 10 −9 [m 2 s sr GeV/n] −1 /3.10 x 10 -10 [m 2 s sr GeV/n] −1 , respectively. The results indicate that GRAMS can extensively investigate various dark matter models through the antihelium-3 measurements.

Antihelium-3↗

Theory of the ion–electron temperature relaxation rate in strongly magnetized plasmas

Recent works have shown that strongly magnetized plasmas characterized by having a gyrofrequency greater than the plasma frequency exhibit novel transport properties. One example is that the friction force on a test charge shifts, obtaining components perpendicular to its velocity in addition to the typical stopping power component antiparallel to its velocity. Here, we apply a recent generalization of the Boltzmann equation for strongly magnetized plasmas to calculate the ion–electron temperature relaxation rate. Strong magnetization is generally found to increase the temperature relaxation rate perpendicular to the magnetic field and to cause the temperatures parallel and perpendicular to the magnetic field to not relax at equal rates. This, in turn, causes a temperature anisotropy to develop during the equilibration. Strong magnetization also breaks the symmetry of independence of the sign of the charges of the interacting particles on the collision rate, commonly known as the “Barkas effect.” Furthermore, it is found that the combination of oppositely charged interaction and strong magnetization causes the ion–electron parallel temperature relaxation rate to be significantly suppressed, scaling inversely proportional to the magnetic field strength.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Structural properties and recrystallization effects in ion beam modified B20-type FeGe films

Disordered iron germanium (FeGe) has recently garnered interest as a testbed for a variety of magnetic phenomena as well as for use in magnetic memory and logic applications. This is partially owing to its ability to host skyrmions and antiskyrmions—nanoscale whirlpools of magnetic moments that could serve as information carriers in spintronic devices. In particular, a tunable skyrmion–antiskyrmion system may be created through precise control of the defect landscape in B20-phase FeGe, motivating the development of methods to systematically tune disorder in this material and understand the ensuing structural properties. To this end, we investigate a route for modifying magnetic properties in FeGe. In particular, we irradiate epitaxial B20-phase FeGe films with 2.8 MeV Au 4+ ions, which creates a dispersion of amorphized regions that may preferentially host antiskyrmions at densities controlled by the irradiation fluence. To further tune the disorder landscape, we conduct a systematic electron diffraction study with in situ annealing, demonstrating the ability to recrystallize controllable fractions of the material at temperatures ranging from ~150 to 250°C. Finally, we describe the crystallization kinetics using the Johnson–Mehl–Avrami–Kolmogorov model, finding that the growth of crystalline grains is consistent with diffusion-controlled one-to-two dimensional growth with a decreasing nucleation rate.

36 MATERIALS SCIENCE↗

Novel application of neutrinos to evaluate U.S. nuclear weapons performance

There is a growing realization that neutrinos can be used as a diagnostic tool to better understand the inner workings of a nuclear weapon. Robust estimates demonstrate that an Inverse Beta Decay (IBD) neutrino scintillation detector built at the Nevada Test Site with a 1000-ton active target mass at a standoff distance of 500 m would detect thousands of antineutrino events per nuclear test. This would provide less than 4% statistical error on the measured antineutrino rate and 5% error on antineutrino energy. Extrapolating this to an error on the test device explosive yield requires knowledge from evaluated nuclear databases, non-equilibrium fission rates, and assumptions on internal neutron fluxes. Initial calculations demonstrate that the total number of neutrinos emitted per fission in the first 10 3 s after a short pulse of 239 Pu fission is about a factor of two less than that from Pu fissioning under steady state conditions. Furthermore, there are significant energy spectral differences as a function of time after the pulse that must be considered. These and other model dependencies will be discussed in the paper. In the absence of nuclear weapons testing, many of the technical and theoretical challenges of a full nuclear test could be mitigated with a low cost smaller scale 20 ton fiducial mass IBD demonstration detector placed near a pulsed reactor. Potential reactors include the Texas A&M University TRIGA 1 GW–10 ms pulsed facility or the Sandia Annular Core Research Reactor. The short duty cycle and repeatability of pulses would provide critical real environment testing and measurements, which would be valuable for planning a possible real test shot in the future. Furthermore, the antineutrino rate as a function of time data would provide unique constraints on fission databases and model assumptions. Finally, there are impactful science drivers such as sensitive searches for ∼1 eV 2 sterile neutrinos and ∼MeV scale axions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗