Search NASASearch

SEARCH · Search NASA

Results for “approximate control variates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Photochemical ozone overburden correction

One-half of the total ozone column is predominantly under photochemical control under all conditions except polar winter. The other half is dynamically controlled. Since the photochemical forcing is phased with the solar declination and modulated by air temperature variation in the upper stratosphere and the dynamic forcing is tied to wave activity in the upper troposphere, the total ozone column is a mixture of the two drivers. If the total ozone is used to infer a property of the dynamic field, namely the tropopause height, it is necessary to correct for the photochemical variations. It should be possible to remove the photochemical component of the total ozone by using SBUV profile information along the orbital track as long as the spatial variations are low frequency. The column integral above the Umkehr levels in the lower stratosphere are examined to determine the level where the spatial variability decreases to the expected photochemical range to find an approximate dividing line between photochemical and dynamic control. Given this a spherical harmonic function will be fitted to the ozone field and subtracted from the TOMS total ozone field. This residual field will then be correlated with tropopause height to determine whether an improvement is obtained over the total ozone correlation.

Stefanick, Michael

Identification and feedback control in structures with piezoceramic actuators

In this lecture we give fundamental well-posedness results for a variational formulation of a class of damped second order partial differential equations with unbounded input or control coefficients. Included as special cases in this class are structures with piezoceramic actuators. We consider approximation techniques leading to computational methods in the context of both parameter estimation and feedback control problems for these systems. Rigorous convergence results for parameter estimates and feedback gains are discussed.

Banks, H. T.

Turbine Electrified Energy Management for Single Aisle Aircraft

Electrified aircraft propulsion technology is being developed to reduce the environmental impacts of the aviation industry. This is prompting the exploration of potential uses and benefits of hybrid systems in which electric powertrains are integrated with more traditional gas turbine propulsion systems. Turbine Electrified Energy Management (TEEM) is an energy management approach for hybrid-electric architectures in which electric machines are connected to the turbofan shafts and used to suppress the off-design operation naturally associated with engine transients. This reduces the need to maintain a large amount of compressor operability margin, thus allowing further exploration of the engine design space. In this study, a 19,000 lbf engine within a parallel hybrid propulsion system is considered along with a 30,000 lbf standalone engine. Data from prior TEEM applications are used to approximate the electric machine sizing required to achieve operability benefits. The TEEM controller is shown to improve operability during transients through the reduction of stall margin undershoots and the decrease of transient variations in component performance maps by over 29%.

Controls

Turbine Electrified Energy Management for Single Aisle Aircraft

Electrified aircraft propulsion technology is being developed to reduce the environmental impacts of the aviation industry. This is prompting the exploration of potential uses and benefits of hybrid systems in which electric powertrains are integrated with more traditional gas turbine propulsion systems. Turbine Electrified Energy Management (TEEM) is an energy management approach for hybrid-electric architectures in which electric machines are connected to the turbofan shafts and used to suppress the off-design operation naturally associated with engine transients. This reduces the need to maintain a large amount of compressor operability margin, thus allowing further exploration of the engine design space. In this study, a 19,000 lbf engine within a parallel hybrid propulsion system is considered along with a 30,000 lbf standalone engine. Data from prior TEEM applications are used to approximate the electric machine sizing required to achieve operability benefits. The TEEM controller is shown to improve operability during transients through the reduction of stall margin undershoots and the decrease of transient variations in component performance maps by over 29%.

EAP

Correlation of ISS Electric Potential Variations with Mission Operations

Orbiting approximately 400 km above the Earth, the International Space Station (ISS) is a unique research laboratory used to conduct ground-breaking science experiments in space. The ISS has eight Solar Array Wings (SAW), and each wing is 11.7 meters wide and 35.1 meters long. The SAWs are controlled individually to maximize power output, minimize stress to the ISS structure, and minimize interference with other ISS operations such as vehicle dockings and Extra-Vehicular Activities (EVA). The Solar Arrays are designed to operate at 160 Volts. These large, high power solar arrays are negatively grounded to the ISS and collect charged particles (predominately electrons) as they travel through the space plasma in the Earth's ionosphere. If not controlled, this collected charge causes floating potential variations which can result in arcing, causing injury to the crew during an EVA or damage to hardware [1]. The environmental catalysts for ISS floating potential variations include plasma density and temperature fluctuations and magnetic induction from the Earth's magnetic field. These alone are not enough to cause concern for ISS, but when they are coupled with the large positive potential on the solar arrays, floating potentials up to negative 95 Volts have been observed. Our goal is to differentiate the operationally induced fluctuations in floating potentials from the environmental causes. Differentiating will help to determine what charging can be controlled, and we can then design the proper operations controls for charge collection mitigation. Additionally, the knowledge of how high power solar arrays interact with the environment and what regulations or design techniques can be employed to minimize charging impacts can be applied to future programs.

Willis, Emily M.

Supersonic aerodynamic characteristics of a series of wrap-around-fin missile configurations

A parametric study of wrap-around-fin missile configurations was conducted at Mach numbers from 1.60 to 2.86 in the Langley Unitary Plan wind tunnel. The fin configurations investigated included variations in chord length, leading edge sweep, thickness ratio, and leading edge shape. The investigation also included a smooth and a stepped-down afterbody required for flush retraction of the wrap-around-fin configuration. The investigation indicated no unusual longitudinal characteristics; however, all the wrap-around-fin configurations tested indicated erratic lateral behavior, particularly in the form of induced roll at zero angle of attack and irregular variations of roll with angle of attack and Mach number. The magnitude of rolling moment at an angle of attack of 0 deg is estimated to represent approximately 0.25 deg or less roll control deflection. The stepped-down afterbody has a marked effect on reducing the induced roll.

Fournier, R. H.

Microwave signatures and surface properties of Ovda Regio and surroundings, Venus

Magellan observations of horizontally and vertically polarized emissivity and radar specific cross sections are jointly modeled to separate dielectric constants from textural effect for lobate plains, fractured plains, fracture belts, festoon flows, and tessera in Ovda Regio and surroundings. The model assumes surface emission and scattering dominate and that signatures are controlled by a combination of quasi-specular and diffuse-scale mechanisms. Textural parameters are found to correlate with geology whereas dielectric constants are found to depend on elevation. A gradual increase in dielectric constant from rock-like values (4 to 5) to a value of approximately 50 is evident over the interval from 6054 to 6056 km, where elevations are derived from Magellan altimetry observations. Stereo radargrammetric analyses demonstrate that a return to rock-like values occurs over approximately 0.5 km above the terrain with highest dielectric constants. The abrupt return to rock-like values occurs independently of geology and reinforces the hypothesis of elevation control on dielectric constant values. Variations in dielectric constant with elevation are modeled using an 1000-ppm concentration of a ferroelectric mineral with a Curie temperature of 707 K. The model reproduces the abrupt change at highest elevations, as the Curie temperature is reached, and the gradual change as lower elevations are encountered. To our knowledge no other model explains the trends with such simplicity.

Arvidson, R. E.

A High-Order Finite Spectral Volume Method for Conservation Laws on Unstructured Grids

A time accurate, high-order, conservative, yet efficient method named Finite Spectral Volume (FSV) is developed for conservation laws on unstructured grids. The concept of a 'spectral volume' is introduced to achieve high-order accuracy in an efficient manner similar to spectral element and multi-domain spectral methods. In addition, each spectral volume is further sub-divided into control volumes (CVs), and cell-averaged data from these control volumes is used to reconstruct a high-order approximation in the spectral volume. Riemann solvers are used to compute the fluxes at spectral volume boundaries. Then cell-averaged state variables in the control volumes are updated independently. Furthermore, TVD (Total Variation Diminishing) and TVB (Total Variation Bounded) limiters are introduced in the FSV method to remove/reduce spurious oscillations near discontinuities. A very desirable feature of the FSV method is that the reconstruction is carried out only once, and analytically, and is the same for all cells of the same type, and that the reconstruction stencil is always non-singular, in contrast to the memory and CPU-intensive reconstruction in a high-order finite volume (FV) method. Discussions are made concerning why the FSV method is significantly more efficient than high-order finite volume and the Discontinuous Galerkin (DG) methods. Fundamental properties of the FSV method are studied and high-order accuracy is demonstrated for several model problems with and without discontinuities.

Wang, Z. J.

Control-structure-thermal interactions in analysis of lunar telescopes

The lunar telescope project was an excellent model for the CSTI study because a telescope is a very sensitive instrument, and thermal expansion or mechanical vibration of the mirror assemblies will rapidly degrade the resolution of the device. Consequently, the interactions are strongly coupled. The lunar surface experiences very large temperature variations that range from approximately -180 C to over 100 C. Although the optical assemblies of the telescopes will be well insulated, the temperature of the mirrors will inevitably fluctuate in a similar cycle, but of much smaller magnitude. In order to obtain images of high quality and clarity, allowable thermal deformations of any point on a mirror must be less than 1 micron. Initial estimates indicate that this corresponds to a temperature variation of much less than 1 deg through the thickness of the mirror. Therefore, a lunar telescope design will most probably include active thermal control, a means of controlling the shape of the mirrors, or a combination of both systems. Historically, the design of a complex vehicle was primarily a sequential process in which the basic structure was defined without concurrent detailed analyses or other subsystems. The basic configuration was then passed to the different teams responsible for each subsystem, and their task was to produce a workable solution without requiring major alterations to any principal components or subsystems. Consequently, the final design of the vehicle was not always the most efficient, owing to the fact that each subsystem design was partially constrained by the previous work. This procedure was necessary at the time because the analysis process was extremely time-consuming and had to be started over with each significant alteration of the vehicle. With recent advances in the power and capacity of small computers, and the parallel development of powerful software in structural, thermal, and control system analysis, it is now possible to produce very detailed analyses of intermediate designs in a much shorter period of time. The subsystems can thus be designed concurrently, and alterations in the overall design can be quickly adopted into each analysis; the design becomes an iterative process in which it is much easier to experiment with new ideas, configurations, and components. Concurrent engineering has the potential to produce efficient, highly capable designs because the effect of one subystem on another can be assessed in much more detail at a very early point in the program. The research program consisted of several tasks: scale a prototype telescope assembly to a 1 m aperture, develop a model of the telescope assembly by using finite element (FEM) codes that are available on site, determine structural deflections of the mirror surfaces due to the temperature variations, develop a prototype control system to maintain the proper shape of the optical elements, and most important of all, demonstrate the concurrent engineering approach with this example. In addition, the software used for the finite element models and thermal analysis was relatively new within the Program Development Office and had yet to be applied to systems this large or complex; understanding the software and modifying it for use with this project was also required. The I-DEAS software by Structural Dynamics Research Corporation (SDRC) was used to build the finite element models, and TMG developed by Maya Heat Transfer Technologies, Ltd. (which runs as an I-DEAS module) was used for the thermal model calculations. All control system development was accomplished with MATRIX(sub X) by Integrated Systems, Inc.

Thompson, Roger C.

Optical range and range rate estimation for teleoperator systems

Range and range rate are crucial parameters which must be available to the operator during remote controlled orbital docking operations. A method was developed for the estimation of both these parameters using an aided television system. An experiment was performed to determine the human operator's capability to measure displayed image size using a fixed reticle or movable cursor as the television aid. The movable cursor was found to yield mean image size estimation errors on the order of 2.3 per cent of the correct value. This error rate was significantly lower than that for the fixed reticle. Performance using the movable cursor was found to be less sensitive to signal-to-noise ratio variation than was that for the fixed reticle. The mean image size estimation errors for the movable cursor correspond to an error of approximately 2.25 per cent in range suggesting that the system has some merit. Determining the accuracy of range rate estimation using a rate controlled cursor will require further experimentation.

Shields, N. L., Jr.

Three-parameter tunable Tilt-Integral-Derivative (TID) controller

A feedback control system compensator of the PID type is provided, wherein the proportional component of the compensator is replaced with a tilted component having a transfer function s to the power of -1/n. The resulting transfer function of the entire compensator more closely approximates an optimal transfer function, thereby achieving improved feedback controller. Further, as compared to conventional PID compensators, the TID compensator allows for simpler tuning, better disturbance rejection ratio, and smaller effects of plant parameter variations on closed loop response.

Lurie, Boris J.

Hovering and Low-Speed Performance and Control Characteristics of the Kaman Helicopter Rotor System as Determined on the Langley Helicopter Tower. TED No. NACA DE 205

An investigation has been conducted with the Langley helicopter tower to obtain basic performance and control characteristics of the Raman rotor system. Blade-pitch control is obtained in this configuration by utilizing an auxiliary flap to twist the blades. Rotor thrust and power required were measured for the hovering condition and over a range of wind velocities from 0 to 30 miles per hour. The control characteristics and the transient response of the rotor to various control movements were also measured. The hovering-performance data are presented as a survey of the wake velocities and the variation of torque coefficient with thrust coefficient. The power required for the test rotor to hover at a thrust of 1350 pounds and a rotor speed of 240 rpm is approximately 6.5 percent greater than that estimated for a conventional rotor of the same diameter and solidity. It is believed that most of this difference is caused by th e flap servomechanism. The reduction in total power required for sustentation of the single-rotor configuration tested at various wind velocities and at the normal operating rotor thrust was found to be similar to the theoretical and experimental results for ro tors with conventionally actuated pitch. The control effectiveness was determined as a function of rotor speed. Sufficient control was available to give a thrust range of 0 to 1500 pounds and a rotor tilt of plus or minus 7 degrees. The time lag between flap motion and blade-pitch response is approximately 0.02 to 0.03 second. The response of the rotor following the blade-pitch response is similar to that of a rotor with conventionally actuated pitch changes. The over-all characteristics of the rotor investigated indicate that satisfactory performance and control characteristics were obtained.

Carpenter, Paul J.

The 7.5 kW solar array simulator

A high power solar array simulator capable of providing the input power to simultaneously operate two 30 cm diameter ion thruster power processors was designed, fabricated, and tested. The maximum power point is set to between 150 and 7500 watts representing an open circuit voltage from 50 to 300 volts and a short circuit current from 4 to 36 amps. Illuminated solar cells are used as the control element to provide a true solar cell characteristic and permit the option of simulating changes in this characteristic due to variations in solar intensity and/or temperature of the solar array. This is accomplished by changing the illumination and/or temperature of the control cells. The response of the output to a step change in load closely approximates that of an actual solar array.

Robson, R. R.

7.5 kW solar array simulator

A high power solar array simulator capable of providing the input power to simultaneously operate two 30 cm diameter ion thruster power processors was designed, fabricated, and tested. The maximum power point may be set to between 150 and 7500 watts. This represents an open circuit voltage from 50 to 300 volts and a short circuit current from 4 to 36 amps. Illuminated solar cells are used as the control element. The illuminated solar cells provide a true solar cell characteristic and permit the option of simulating changes in this characteristic due to variations in solar intensity and/or temperature of the solar array. This is accomplished by changing the illumination and/or temperature of the control cells. The response of the output to a step change in load closely approximates that of an actual solar array.

Robson, R. R.

Adaptive attitude control and momentum management for large-angle spacecraft maneuvers

The fully coupled equations of motion are systematically linearized around an equilibrium point of a gravity gradient stabilized spacecraft, controlled by momentum exchange devices. These equations are then used for attitude control system design of an early Space Station Freedom flight configuration, demonstrating the errors caused by the improper approximation of the spacecraft dynamics. A full state feedback controller, incorporating gain-scheduled adaptation of the attitude gains, is developed for use during spacecraft on-orbit assembly or operations characterized by significant mass properties variations. The feasibility of the gain adaptation is demonstrated via a Space Station Freedom assembly sequence case study. The attitude controller stability robustness and transient performance during gain adaptation appear satisfactory.

Parlos, Alexander G.

Five-Year (2004-2009)Observations of Upper Tropospheric Water Vapor and Cloud Ice from MLS and Comparisons with GEOS-5 Analyses

This paper gives an overview of August 2004 through July 2009 upper tropospheric (UT) water vapor (H2O) and ice water content (IWC) from the Aura Microwave Limb Sounder (MLS) and comparisons with outputs from the NASA Goddard Earth Observing System Version 5 (GEOS-5) data assimilation system. Both MLS and GEOS-5 show that high values of H2O and IWC at 215 to 147 hPa are associated with areas of deep convection. They exhibit good (within approximately 15%) agreement in IWC at these altitudes, but GEOS-5 H2O is approximately 50% (215 hPa) to approximately 30% (147 hPa) larger than MLS, possibility due to its higher temperatures at these altitudes. GOES-5 produces a weaker intertropical convergence zone than MLS, while a seasonally-migrating band of tropical deep convection is clearly evident in both the MLS and GEOS-5 UT H2O and IWC. MLS and GEOS-5 both show spatial anti-correlation between IWC and H2O at 100 hPa, where less H2O is associated with low temperatures in regions of tropical convection. At 100 hPa, GEOS-5 produces 50% less IWC and 15% less H2O in the tropics, and approximately 20% more H2O in the extra-tropics, than does MLS. Behavior of the 100 hPa H2O, which exhibits a quasi-biennial oscillation, appears consistent with it being controlled by temperature. The seasonal cycle in the vertical transport of tropical mean H2O from approximately 147 hPa to approximately 10 hPa appears much stronger in MLS than in GEOS-5. The UT IWC and H2O interannual variations, from both MLS and GEOS-5, show clear imprints of the El Nino-Southern Oscillation.

Jiang, Jonathan H.