Search NASA⌕ Search

SEARCH · Search NASA

Results for “arc column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Dosimetric and geometric evaluation of a novel stereotactic radiotherapy device for breast cancer: The GammaPod Trade-Mark-Sign

Purpose: A dedicated stereotactic gamma irradiation device, the GammaPod Trade-Mark-Sign from Xcision Medical Systems, was developed specifically to treat small breast cancers. This study presents the first evaluation of dosimetric and geometric characteristics from the initial prototype installed at University of Maryland Radiation Oncology Department. Methods: The GammaPod Trade-Mark-Sign stereotactic radiotherapy device is an assembly of a hemi-spherical source carrier containing 36 {sup 60}Co sources, a tungsten collimator, a dynamically controlled patient support table, and the breast immobilization system which also functions as a stereotactic frame. The source carrier contains the sources in six columns spaced longitudinally at 60 Degree-Sign intervals and it rotates together with the variable-size collimator to form 36 noncoplanar, concentric arcs focused at the isocenter. The patient support table enables motion in three dimensions to position the patient tumor at the focal point of the irradiation. The table moves continuously in three cardinal dimensions during treatment to provide dynamic shaping of the dose distribution. The breast is immobilized using a breast cup applying a small negative pressure, where the immobilization cup is embedded with fiducials also functioning as the stereotactic frame for the breast. Geometric and dosimetric evaluations of the system as well as a protocol for absorbed dose calibration are provided. Dosimetric verifications of dynamically delivered patient plans are performed for seven patients using radiochromic films in hypothetical preop, postop, and target-in-target treatment scenarios. Results: Loaded with 36 {sup 60}Co sources with cumulative activity of 4320 Ci, the prototype GammaPod Trade-Mark-Sign unit delivers 5.31 Gy/min at the isocenter using the largest 2.5 cm diameter collimator. Due to the noncoplanar beam arrangement and dynamic dose shaping features, the GammaPod Trade-Mark-Sign device is found to deliver uniform doses to targets with good conformity. The spatial accuracy of the device to locate the radiation isocenter is determined to be less than 1 mm. Single shot profiles with 2.5 cm collimator are measured with radiochromic film and found to be in good agreement with respect to the Monte Carlo based calculations (congruence of FWHM less than 1 mm). Dosimetric verifications corresponding to all hypothetical treatment plans corresponding to three target scenarios for each of the seven patients demonstrated good agreement with gamma index pass rates of better than 97% (99.0%{+-} 0.7%). Conclusions: Dosimetric evaluation of the first GammaPod Trade-Mark-Sign stereotactic breast radiotherapy unit was performed and the dosimetric and spatial accuracy of this novel technology is found to be feasible with respect to clinical radiotherapy standards. The observed level of agreement between the treatment planning system calculations and dosimetric measurements has confirmed that the system can deliver highly complex treatment plans with remarkable geometric and dosimetric accuracy.

60 APPLIED LIFE SCIENCES↗

Aperture synthesis observations of the molecular ring in the galactic center

Reported are 88 GHz aperture synthesis observations of HCN J=1 yields 0 emission and absorption in the central 5 pc of the Galaxy. The data, taken by the Hat Creek mm-interferometer at 5" to 10" spatial and 4 km/s spectral resolution, show a complete, clumpy ring of molecular gas surrounding the ionized central 2 pc of the Galaxy. The ring is the inner edge of a larger disk extending to about 5 pc. Comparison with sub-mm line data suggests that the HCN 1-0 line is slightly optically thick and originates in subthermally populated gas. The clumpy line emission distribution reflects a combination of hydrogen volume and column density variations. The new data clearly show a close physical relation between the molecular and the ionized gas in the central cavity. The western arc appears to be the ionized inner surface of the molecular ring, and the northern arm and bar may be streamers of ionized gas falling from the ring toward the center. The dominant large scale velocity pattern of the majority of the molecular gas in the inner 5 pc is rotation. No overall radial motion of the ring greater than about 20 km/s is apparent. The rotation is perturbed in several ways; (1) there is a very large local velocity dispersion, (2) the ring shows changes in position angle and inclination (warps), (3) there is a bright, redshifted cloud which appears to be located in the western part of the ring but does not participate in the rotation. These characteristics and the high degree of clumpiness indicate a non-equilibrium configuration of short (less than or approx. 10 to the 4th power to 10 to the 5th power y) dynamical lifetime. The warping and tilting of the structure and the short dynamical lifetime make an accurate determination of equilibrium rotation velocity uncertain.

Guesten, R.↗

Modeling of Unsaturated Salt-cake Dissolution for S-109 Simulant

The Environmental Simulation Program (V7.0, OLI Systems, Inc.) with V7DBLSLT, the latest version of the double salt database developed by the Institute of Clean Energy Technology (ICET), was used to predict effluent stream compositions and densities, residual salt-cake composition, and salt-cake heights for an unsaturated salt-cake dissolution test with a simulant representative of waste contained in Hanford tank 241-S-109. Predictions for major cation and anion concentrations were in excellent agreement with the experimental data obtained at the Applied Research Center (ARC) at Florida International University (FIU). The utility of ESP as a means to predict effluent stream compositions and effluent stream properties, such as density and column salt-cake height, is demonstrated through the agreement between experimental and predicted values. These, and previous calculations, validate the use of thermodynamic models (with proper chemistry representations) for HLW pretreatment and retrievals. A powerful and useful tool is the result. Cost reductions are possible as the amount of sampling and subsequent laboratory analysis can be reduced. Additionally, overall processing risk is reduced through the ability to rapidly evaluate different processing and retrieval scenarios. The application of appropriate models can thus lead to more efficient operations and campaign cost savings while also evaluating parameters pertinent to safety. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design, Installation and Performance of the New insulator for NSTX CHI Experiments

Coaxial Helicity Injection (CHI), a non-inductive method to initiate plasma and generate toroidal plasma current, is being investigated in the National Spherical Torus Experiment (NSTX). The center stack and outer vacuum vessel are separated by insulating gaps at the top and bottom of the slim central column so that a high voltage (up to 2 kV) can be applied between them from a pulsed power supply or a capacitor bank to initiate an arc discharge. In the presence of a suitable poloidal magnetic field, the discharge is initiated at the lower gap (the injector gap) and because of the strong toroidal field develops a helical structure resulting in substantial toroidal plasma current being driven. In NSTX, up to 390 kA of toroidal current has been generated for an injected current of 25 kA. The early investigations of CHI however frequently developed arcs across the insulator at the top of the machine (the absorber gap), which terminated the desired discharge. This arcing greatly restricted the operational space available for CHI studies. During 2002, the absorber region was modified to suppress these arcs. The new design includes a new ceramic insulator on the high field side of the absorber region with a much longer tracking distance between conducting elements at the different potentials. Furthermore, two new coils were installed near the absorber to provide the ability to minimize the poloidal field connecting the center stack and outer vacuum vessel. During the subsequent experimental campaign, CHI operation was less prone to arcing in the absorber and those arcs that did occur did not terminate the main discharge.)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A ROSAT observation of the transient X-ray pulsar GRO J1008-57

We report results of a brief Target of Oppurtunity observation of the newly discovered transient X-ray pulsar Gamma Ray Observatory (GRO) J1008-57 using the ROSAT Position Sensitive Proportional Counter (PSPC). The observation was performed well into the decline of the source outburst as monitored by the BATSE hard X-ray light curve. The PSPC cleanly detected the source, at a 0.1-2.4 keV flux of 2.3 x 10(exp -11) erg/sq cm/s. A position centroid accurate to 10 arc seconds has been determined. The 0.1-2.4 keV spectrum is best characterized by a flat power law with substantial interstellar absorption. The PSPC photon index and column density are consistent with that measured at higher energy by ASCA; there is no evidence for an additional soft component. Light-curve folding reveals a period of 93.4 s, consistent with that measured at higher energies; the 0.1-2.4 keV folded light curve shows a high pulsed fraction and a strongly double-peaked pulse profile. The spectral and temporal properties of GRO J1008-57 as observed using the PSPC are entirely consistent with a pulsar orbiting a massive (OB) companion.

Petre, R.↗

4π Non-Coplanar Liver SBRT: A Novel Delivery Technique

Purpose: To improve the quality of liver stereotactic body radiation therapy (SBRT) treatments, a novel 4π framework was developed with accompanying algorithms to optimize non-coplanar beam orientations and fluences. The dose optimization is performed on a patient-specific deliverable beam geometry solution space, parameterized with patient and linear accelerator gantry orientations. Methods and Materials: Beams causing collision between the gantry and the couch or patient were eliminated by simulating all beam orientations using a precise computer assisted design model of the linear accelerator and a human subject. Integrated beam orientation and fluence map optimizations were performed on remaining beams using a greedy column generation method. Testing of the new method was performed on 10 liver SBRT cases previously treated with 50 to 60 Gy in 5 fractions using volumetric modulated arc therapy (VMAT). For each patient, both 14 and 22 non-coplanar fields were selected and optimized to meet the objective of ≥95% of the planning target volume (PTV) covered by 100% of the prescription dose. Doses to organs at risk, normal liver volumes receiving <15 Gy, integral dose, and 50% dose spillage volumes were compared against the delivered clinical VMAT plans. Results: Compared with the VMAT plans, the 4π plans yielded reduced 50% dose spillage volume and integral dose by 22% (range 10%-40%) and 19% (range 13%-26%), respectively. The mean normal liver volume receiving <15 Gy was increased by 51 cc (range 21-107 cc) with a 31% reduction of the mean normal liver dose. Mean doses to the left kidney and right kidney and maximum doses to the stomach and spinal cord were on average reduced by 70%, 51%, 67%, and 64% (P≤.05). Conclusions: This novel 4π non-coplanar radiation delivery technique significantly improved dose gradient, reduced high dose spillage, and improved organ at risk sparing compared with state of the art VMAT plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Airborne Remote Sensing Measurements of Particles in Different Parts of the World

Around the globe, atmospheric aerosols pose a significant yet uncertain impact on the Earth's climate, environmental air quality and human health. Suborbital sunphotometer measurements of Aerosol Optical Depth (AOD) (i.e., the amount of direct-beam solar light attenuated by aerosols within the atmospheric column) are used to validate satellite aerosol retrievals and are valuable when studying aerosol-solar radiation and/ or aerosol-cloud interactions. Since 1985, NASA Ames Research Center (ARC) has been using airborne sun-tracking sunphotometers to measure atmospheric constituents such as aerosols, clouds, and gases. The NASA Ames Airborne Tracking Sunphotometer (AATS-6) and then (AATS-14) operate by tracking the sun and measuring the transmission of solar radiation in 6 to 14 discrete spectral channels (Russell et al., 1986). The AATS systems were followed by the more advanced hyperspectral 4STAR instrument (Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research; Dunagan et al., 2013), which combines the airborne sun-tracking capability of the AATS-14 with a sky scanning feature similar to the ground-based Aerosol Robotic Network Sun/sky photometers (AERONET). We present a comprehensive analysis of ~30 airborne campaigns undertaken by NASA and DoE based on a new database of airborne sunphotometer measurements. Using this database, we present a clear picture of airborne AODs over the range of historical campaigns and the aerosol sizes per region, especially over the ocean where AERONET data is limited. With this database, we can investigate systematic differences in AOD such as those observed over different land and ocean surfaces in specific geographical regions. Finally, we will briefly show comparisons with satellite aerosol retrievals from MODIS and/or VIIRS. Russell, P. B., T. Matsumoto, V. J. Banta, J. M. Livingston, C. Mina, D. S. Colburn, and R. F. Pueschel (1986), Measurements with an airborne, autotracking, external-head sunphotometer, Preprint Volume, Sixth Conference on Atmospheric Radiation, May 13–16, 1986, Amer. Meteor.Soc., Boston, MA, 55–58. Dunagan, Stephen E., et al. "Spectrometer for sky-scanning sun-tracking atmospheric research (4STAR): Instrument technology." Remote Sensing 5.8 (2013): 3872-3895

Brendan Stover Cornelison↗

Ultrafast treatment plan optimization for volumetric modulated arc therapy (VMAT)

Purpose: To develop a novel aperture-based algorithm for volumetric modulated arc therapy (VMAT) treatment plan optimization with high quality and high efficiency. Methods: The VMAT optimization problem is formulated as a large-scale convex programming problem solved by a column generation approach. The authors consider a cost function consisting two terms, the first enforcing a desired dose distribution and the second guaranteeing a smooth dose rate variation between successive gantry angles. A gantry rotation is discretized into 180 beam angles and for each beam angle, only one MLC aperture is allowed. The apertures are generated one by one in a sequential way. At each iteration of the column generation method, a deliverable MLC aperture is generated for one of the unoccupied beam angles by solving a subproblem with the consideration of MLC mechanic constraints. A subsequent master problem is then solved to determine the dose rate at all currently generated apertures by minimizing the cost function. When all 180 beam angles are occupied, the optimization completes, yielding a set of deliverable apertures and associated dose rates that produce a high quality plan. Results: The algorithm was preliminarily tested on five prostate and five head-and-neck clinical cases, each with one full gantry rotation without any couch/collimator rotations. High quality VMAT plans have been generated for all ten cases with extremely high efficiency. It takes only 5-8 min on CPU (MATLAB code on an Intel Xeon 2.27 GHz CPU) and 18-31 s on GPU (CUDA code on an NVIDIA Tesla C1060 GPU card) to generate such plans. Conclusions: The authors have developed an aperture-based VMAT optimization algorithm which can generate clinically deliverable high quality treatment plans at very high efficiency.

61 RADIATION PROTECTION AND DOSIMETRY↗

A new method for the preparation of polymeric porous layer open tubular columns for GC application

A new method to prepare polymeric PLOT columns by using in situ polymerization technology is described. The method involves a straightforward in situ polymerization of the monomer. The polymer produced is directly coated on the metal tubing. This eliminates many of the steps needed in conventional polymeric PLOT column preparation. Our method is easy to operate and produces very reproducible columns, as shown previously (T. C. Shen. J. Chromatogr. Sci. 30, 239, 1992). The effects of solvents, tubing pretreatments, initiators and reaction temperatures in the preparation of PLOT columns are studied. Several columns have been developed to separate (1) highly polar compounds, such as water and ammonia or water and HCN, and (2) hydrocarbons and inert gases. A recent improvement has allowed us to produce bonded polymeric PLOT columns. These were studied, and the results are included also.

NASA Discipline Exobiology↗

Sediment oxygen profiles in a super-oxygenated antarctic lake

Perennially ice-covered lakes are found in the McMurdo Dry Valleys of southern Victoria Land, Antarctica. In contrast to temperate lakes that have diurnal photic periods, antarctic (and arctic) lakes have a yearly photic period. An unusual feature of the antarctic lakes is the occurrence of O2 at supersaturated levels in certain portions of the water column. Here we report the first sediment O2 profiles obtained using a microelectrode from a perennially ice-covered antarctic lake. Sediment cores collected in January and October 1987 from Lake Hoare in Taylor Valley show oxygenation down to 15, and in some cases, 25 cm. The oxygenation of sediments several centimeters below the sediment-water interface is atypical for lake sediments and may be characteristic of perennially ice-covered lakes. There is a significant difference between the observed January and October sediment O2 profiles. Several explanations may account for the difference, including seasonality. A time-dependent model is presented which tests the feasibility of a seasonal cycle resulting from the long photoperiod and benthic primary production in sediments overlain by a highly oxygenated water column.

NASA Center ARC↗

In-situ polymerization PLOT columns I: divinylbenzene

A novel method for preparation of porous-layer open-tubular (PLOT) columns is described. The method involves a simple and reproducible, straight-forward in-situ polymerization of monomer directly on the metal tube.

NASA Center ARC↗

In-situ polymerization PLOT columns I: divinylbenzene

A novel method for preparation of porous-layer open-tubular (PLOT) columns is described. The method involves a simple and reproducible, straight-forward in-situ polymerization of monomer directly on the metal tube.

NASA Center ARC↗

RADIO PULSATION SEARCH AND IMAGING STUDY OF SGR J1935+2154

We present the results obtained from imaging observations and a search for radio pulsations toward the magnetar SGR J1935+2154 made using the Giant Metrewave Radio Telescope and the Ooty Radio Telescope. We present the high-resolution radio image of the supernova remnant (SNR) G57.2+0.8, which is positionally associated with SGR J1935+2154. We did not detect significant periodic radio pulsations from the magnetar, with 8 σ upper limits on its flux density of 0.4 and 0.2 mJy at 326.5 and 610 MHz, respectively, for an assumed duty cycle of 10%. The corresponding 6 σ upper limits at the two frequencies for any burst emission with an assumed width of 10 ms are 0.5 Jy and 63 mJy, respectively. No continuum radio point source was detected at the position of SGR J1935+2154 with a 3 σ upper limit of 1.2 mJy. We also did not detect significant diffuse radio emission in a radius of 70 arc s coinciding with the recently reported diffuse X-ray emission, with a 3 σ upper limit of 4.5 mJy. Using the archival HI spectra, we estimate the distance of SNR G57.2+0.8 to be 11.7 ± 2.8 kpc. Based on the measured HI column density ( N {sub H} ) along this line of sight, we argue that the magnetar could be physically associated with SNR G57.2+0.8. Based on the present data, we cannot rule out either a pulsar wind nebula or a dust-scattering halo origin for the diffuse X-ray emission seen around the magnetar.

79 ASTRONOMY AND ASTROPHYSICS↗

Observations of the soft X-ray diffuse background at 0.1 keV

The results of a sounding rocket flight that observed the very soft X-ray diffuse background in a section of the northern Galactic hemisphere are presented. The ratio of the measured Be band count rates to the Wisconsin sky survey B band count rates is nearly constant over a 120 deg arc on the sky, strongly suggesting a common emission mechanism for both Be and B band X-rays. The mean free path is about seven times smaller for the Be band than for the B band. The present results imply that the neutral hydrogen column density between the emitting material and the earth varies by less than 2 x 10 to the 18th H I/sq cm over the observed region. It is concluded that such variations are unlikely unless the total intervening column density is less than a few times this value.

Bloch, J. J.↗

The Spectrum of Titan near 3.4 Micron: Comparison of Spectral Features to Organic Molecules

In August 1993 we observed the spectrum of Titan from 2.9 to 4.1 micrometers at a resolving power of R=500-1000 (dw approx. 2-4 per cm). The spectrum shows, as expected, a strong absorption throughout this region from three strong bands Of CH4. However, comparison of the spectrum to simple radiative transfer models and to the spectrum of Jupiter reveal some interesting differences. A broad emission feature that we attribute to CH4 is centered at 3.3 micrometers. At 3.45 micrometers we see a distinct narrow absorption feature that is present in both the Jupiter and laboratory spectrum, but only when other features, absent in the Titan spectrum, are also present. In our attempt to understand the origin of this spectral feature we have compared the spectrum to CH4 and other organic molecules. Interesting similarities appear between the aliphatic hydrocarbons (CH2 and CH3 groups) seen in laboratory organics and the Titan spectrum, but only if we assume that the shorter wavelength feature (CH3) is masked by the broad CH4 emission. A second problem with the explanation is that like column abundance of organic haze (Toon et al. 1991) is insufficient to provide the required number of molecules to create a spectral feature with tau approx. 1. Laboratory organics produced through a variety of processes have been compared to the Titan spectrum and the results arc presented.

Pendleton, Yvonne↗

757 Fly-By-Wire Demonstrator Flight Test

The Boeing Company modified a production 757-200 to emulate the 777 fly-by-wire control laws in order to evaluate the operation and performance of the 777 FBW flight control laws in flight. Following installation and checkout of the FBW system, testing began in March, 1992. Flight testing is currently planned to continue through August, 1992. The conventional 757 longitudinal flight control system is retained but controlled by only the captain’s column. The fly-by-wire system is evaluated by the pilot in the first officer’s seat and the safety pilot function is conducted from the captain’s seat. The flight test FBW longitudinal system is a 2-channel flight control system. The first officer’s column drives the current 757 left and right flight control computers (autopilots) which are modified to act as FBW computers. These FBW computers, which emulate the 777-200 FBW control laws, drive their respective autopilot actuators to control the airplane pitch axis. Directional FBW control laws arc emulated in the existing 757 yaw dampers, with corresponding modifications to the normal 757 directional control system. This paper presents a summary of the airplane FBW modifications and the flight test program to evaluate/validate the 777 FBW flight control laws.

Flight Testing↗

WE-AB-209-09: Optimization of Rotational Arc Station Parameter Optimized Radiation Therapy

Purpose: To develop a fast optimization method for station parameter optimized radiation therapy (SPORT) and show that SPORT is capable of improving VMAT in both plan quality and delivery efficiency. Methods: The angular space from 0° to 360° was divided into 180 station points (SPs). A candidate aperture was assigned to each of the SPs based on the calculation results using a column generation algorithm. The weights of the apertures were then obtained by optimizing the objective function using a state-of-the-art GPU based Proximal Operator Graph Solver (POGS) within seconds. Apertures with zero or low weight were thrown out. To avoid being trapped in a local minimum, a stochastic gradient descent method was employed which also greatly increased the convergence rate of the objective function. The above procedure repeated until the plan could not be improved any further. A weighting factor associated with the total plan MU also indirectly controlled the complexities of aperture shapes. The number of apertures for VMAT and SPORT was confined to 180. The SPORT allowed the coexistence of multiple apertures in a single SP. The optimization technique was assessed by using three clinical cases (prostate, H&N and brain). Results: Marked dosimetric quality improvement was demonstrated in the SPORT plans for all three studied cases. Prostate case: the volume of the 50% prescription dose was decreased by 22% for the rectum. H&N case: SPORT improved the mean dose for the left and right parotids by 15% each. Brain case: the doses to the eyes, chiasm and inner ears were all improved. SPORT shortened the treatment time by ∼1 min for the prostate case, ∼0.5 min for brain case, and ∼0.2 min for the H&N case. Conclusion: The superior dosimetric quality and delivery efficiency presented here indicates that SPORT is an intriguing alternative treatment modality.

60 APPLIED LIFE SCIENCES↗

Interpreting Temperature Strain Data from Meso-Scale Clathrate Experiments

Gas hydrates are important in global climate change, carbon sequestra- tion, and seafloor stability. Currently, formation and dissociation pathways are poorly defined. We present a new approach for processing large amounts of data from meso-scale experiments, such as the LUNA distributed sensing system (DSS) in the seafloor process simulator (SPS) at Oak Ridge National Laboratory. The DSS provides a proxy for temperature measurement with a high spatial resolution allowing the heat of reaction during gas hydrate formation/dissociation to aid in locating clathrates in the vessel. The DSS fibers are placed in the sediment following an Archimedean spiral design and then the position of each sensor is solved by iterating over the arc length formula with Newtons method. The data is then gridded with 1 a natural neighbor interpolation algorithm to allow contouring of the data. The solution of the sensor locations is verified with hot and cold stimulus in known locations. An experiment was preformed with a vertically split column of sand and silt. The DSS system clearly showed hydrate forming in the sand first, then slowly creeping into the silt. Similar systems and data processing techniques could be used for monitoring of hydrates in natural environments or in any situation where a hybrid temperature/strain index is useful. Further ad- vances in fiber technology allow the fiber to be applied in any configuration and the position of each sensor to be precisely determined making practical applications easier.

54 ENVIRONMENTAL SCIENCES↗