Search NASA⌕ Search

SEARCH · Search NASA

Results for “arraying”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Characterization of a gamma-ray tracking array: A comparison of GRETINA and Gammasphere using a 60 Co source

In this paper, we provide a formalism for the characterization of the tracking arrays with emphasis on the proper corrections required to extract their photopeak efficiencies and peak-to-total ratios. The methods are first applied to Gammasphere, a well characterized 4pi array based on the principle of Compton suppression, and subsequently to GRETINA. The tracking efficiencies are then discussed and some guidelines as to what clustering angle to use in the tracking algorithm are presented. It was possible, using GEANT4 simulations, to scale the measured efficiencies up to the expected values for the full 4pi implementation of GRETA.

efficiency measurements↗

Versioned distributed arrays for resilience in scientific applications: Global view resilience

Exascale studies project reliability challenges for future high-performance computing (HPC) systems. We propose the Global View Resilience (GVR) system, a library that enables applications to add resilience in a portable, application-controlled fashion using versioned distributed arrays. We describe GVR’s interfaces to distributed arrays, versioning, and cross-layer error recovery. Using several large applications (OpenMC, the preconditioned conjugate gradient solver PCG, ddcMD, and Chombo), we evaluate the programmer effort to add resilience. The required changes are small (<2% LOC), localized, and machine-independent, requiring no software architecture changes. We also measure the overhead of adding GVR versioning and show that generally overheads <2% are achieved. We conclude that GVR’s interfaces and implementation are flexible and portable and create a gentle-slope path to tolerate growing error rates in future systems.

97 MATHEMATICS AND COMPUTING↗

Solution-state conformational ensemble of a hexameric prophyrin array characterized using molecular dynamics and x-ray scattering.

Solution-phase X-ray scattering measurements in combination with coordinate-based modeling have been used to characterize the conformational ensemble of a hexameric, diphenylethyne-linked porphyrin array in solution. Configurationally broadened X-ray scattering patterns measured at room temperature for dilute toluene solutions of the porphyrin array were compared to scattering patterns calculated from structural ensembles in constant pressure and temperature molecular dynamics simulations. Thermal fluctuations sampled at picosecond intervals within nanosecond time scale dynamic simulations show large-amplitude motions that include porphyrin ring 'tipping' around the porphyrin linkage axes and extended hexameric porphyrin array 'breathing' motions involving torsional distortions collectively distributed along porphyrin and diphenylethyne groups. Each type of group motion produced characteristic, angle-dependent dampening of scattering features that are needed to reproduce dampening features in the experimental X-ray scattering. However, mismatches in the magnitudes of experimental and simulated dampening of high-angle X-ray scattering patterns show that large-amplitude hexamer array breathing-type motions are significantly under-represented in the simulated ensembles. This comparison between experiment and simulation provides a means not only to interpret scattering data in terms of an explicit atomic model but more generally demonstrates the use of solution X-ray scattering as an experimental benchmark for the development of simulation methods that more accurately predict configurational dynamics of supramolecular assemblies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of the ORRUBA Silicon Detector Array

High quality radioactive beams have recently made possible the measurement of (d,p) reactions on unstable nuclei in inverse kinematics, which can yield information on the development of single-neutron structure away from stability, and are of astrophysical interest due to the proximity to suggested r-process paths. The Oak Ridge Rutgers University Barrel Array (ORRUBA) is a new high solid-angular coverage array, composed of two rings of silicon detectors, optimized for measuring (d,p) reactions. A partial implementation has been used to measure (d,p) reactions on nuclei around the N = 82 shell closure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High density Langmuir probe array for NSTX scrape-off layer measurements under lithiated divertor conditions

A high density Langmuir probe array has been developed for measurements of scrape-off layer parameters in NSTX. Relevant scale lengths for heat and particle fluxes are 1-5 cm. Transient edge plasma events can occur on a time scale of several milliseconds, and the duration of a typical plasma discharge is {approx}1 s. The array consists of 99 individual electrodes arranged in three parallel radial rows to allow both swept and triple-probe operation and is mounted in a carbon tile located in the lower outer divertor of NSTX between two segments of the newly installed liquid lithium divertor. Initial swept probe results tracking the outer strike point through probe flux measurements are presented.

36 MATERIALS SCIENCE↗

CASCADES: An Ultra-Low-Background Germanium Crystal Array at Pacific Northwest National Laboratory

State-of-the-art treaty verification techniques, environmental surveillance, and physics experiments require increased sensitivity for detecting and quantifying radionuclides of interest. This can be accomplished with new detector designs that establish high detection efficiency and reduced instrument backgrounds. Current research is producing an intrinsic germanium (HPGe) array designed for high detection efficiency, ultra-low-background performance, and sensitive {gamma}--{gamma} coincidence detection. The system design is optimized to accommodate filter paper samples, e.g. samples collected by the Radionuclide Aerosol Sampler/Analyzer. The system will provide high sensitivity for weak collections on atmospheric filter samples (e.g.<10{sup 5} fissions) as well as offering the potential to gather additional information from higher activity filters using gamma cascade coincidence detection. The first of two HPGe crystal arrays in ultra-low-background vacuum cryostats has been assembled, with the second in progress. Traditional methods for constructing ultra-low-background detectors were followed, including use of materials known to be low in radioactive contaminants, use of ultra-pure reagents, and clean room assembly. The cryostat is constructed mainly from copper electroformed into near-final geometry at Pacific Northwest National Laboratory. Details of the detector assembly and initial background and spectroscopic measurement results are presented; also a description of the custom analysis package used by this project is given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contrasting physics in wire array z pinch sources of 1-20 keV emission on the Z facility

Imploding wire arrays on the 20 MA Z generator have recently provided some of the most powerful and energetic laboratory sources of multi-keV photons, including ∼375 kJ of Al K-shell emission (hν ∼ 1–2 keV), ∼80 kJ of stainless steel K-shell emission (hν ∼ 5–9 keV) and a kJ-level of Mo K-shell emission (hν ∼ 17 keV). While the global implosion dynamics of these different wire arrays are very similar, the physical process that dominates the emission from these x-ray sources fall into three broad categories. Al wire arrays produce a column of plasma with densities up to ∼3 × 10{sup 21} ions/cm{sup 3}, where opacity inhibits the escape of K-shell photons. Significant structure from instabilities can reduce the density and increase the surface area, therefore increase the K-shell emission. In contrast, stainless steel wire arrays operate in a regime where achieving a high pinch temperature (achieved by thermalizing a high implosion kinetic energy) is critical and, while opacity is present, it has less impact on the pinch emissivity. At higher photon energies, line emission associated with inner shell ionization due to energetic electrons becomes important.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operation of an ungated diamond field-emission array cathode in a L-band radiofrequency electron source

We report on the operation of a field-emitter-array cathode in a conventional L-band radio-frequency electron source. The cathode consisted of an array of ∼10{sup 6} diamond tips on pyramids. Maximum current on the order of 15 mA was reached and the cathode did not show appreciable signs of fatigue after weeks of operation. The measured Fowler-Nordheim characteristics, transverse beam density, and current stability are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Self characterization of a coded aperture array for neutron source imaging

The neutron imaging system at the National Ignition Facility (NIF) is an important diagnostic tool for measuring the two-dimensional size and shape of the neutrons produced in the burning deuterium-tritium plasma during the stagnation stage of inertial confinement fusion implosions. Since the neutron source is small (∼100 μm) and neutrons are deeply penetrating (>3 cm) in all materials, the apertures used to achieve the desired 10-μm resolution are 20-cm long, triangular tapers machined in gold foils. These gold foils are stacked to form an array of 20 apertures for pinhole imaging and three apertures for penumbral imaging. These apertures must be precisely aligned to accurately place the field of view of each aperture at the design location, or the location of the field of view for each aperture must be measured. In this paper we present a new technique that has been developed for the measurement and characterization of the precise location of each aperture in the array. We present the detailed algorithms used for this characterization and the results of reconstructed sources from inertial confinement fusion implosion experiments at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broadband resonances in indium-tin-oxide nanorod arrays

There is currently much discussion within the nanophotonics community regarding the origin of wavelength selective absorption/scattering of light by the resonances in nanorod arrays. Here, we report a study of resonances in ordered indium-tin-oxide nanorod arrays resulting from waveguide-like modes. We find that with only a 2.4% geometrical coverage, micron-length nanorod arrays interact strongly with light across a surprisingly wide band from the visible to the mid-infrared, resulting in less than 10% transmission. Simulations show excellent agreement with our experimental observations. The field profile in the vicinity of the rods obtained from simulations shows that the electric field is mainly localized on the surfaces of the nanorods for all resonances. Based on our analysis, the resonances in the visible are different in character from those in the infrared. When light is incident on the array, part of it propagates in the space between the rods and part of it is guided within the rods. The phase difference (interference) at the ends of the rods forms the basis for the resonances in the visible region. The resonances in the infrared are Fabry-Perot-like resonances involving standing surface waves between the opposing ends of the rods. Simple analytical formulae predict the spectral positions of these resonances. It is suggested that these phenomena can be utilized for wavelength-selective photodetectors, modulators, and nanorod-based solar cells.

14 SOLAR ENERGY↗

Study of ablation and implosion stages in wire arrays using coupled ultraviolet and X-ray probing diagnostics

Star and cylindrical wire arrays were studied using laser probing and X-ray radiography at the 1-MA Zebra pulse power generator at the University of Nevada, Reno. The Leopard laser provided backlighting, producing a laser plasma from a Si target which emitted an X-ray probing pulse at the wavelength of 6.65 Å. A spherically bent quartz crystal imaged the backlit wires onto X-ray film. Laser probing diagnostics at the wavelength of 266 nm included a 3-channel polarimeter for Faraday rotation diagnostic and two-frame laser interferometry with two shearing interferometers to study the evolution of the plasma electron density at the ablation and implosion stages. Dynamics of the plasma density profile in Al wire arrays at the ablation stage were directly studied with interferometry, and expansion of wire cores was measured with X-ray radiography. The magnetic field in the imploding plasma was measured with the Faraday rotation diagnostic, and current was reconstructed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of the phase control of the ITER ICRH antenna array. Influence on the load resilience and radiated power spectrum

The paper analyses how the phasing of the ITER ICRH 24 strap array evolves from the power sources up to the strap currents of the antenna. The study of the phasing control and coherence through the feeding circuits with prematching and automatic matching and decoupling network is made by modeling starting from the TOPICA matrix of the antenna array for a low coupling plasma profile and for current drive phasing (worst case for mutual coupling effects). The main results of the analysis are: (i) the strap current amplitude is well controlled by the antinode V{sub max} amplitude of the feeding lines, (ii) the best toroidal phasing control is done by the adjustment of the mean phase of V{sub max} of each poloidal straps column, (iii) with well adjusted system the largest strap current phasing error is ±20°, (iv) the effect on load resilience remains well below the maximum affordable VSWR of the generators, (v) the effect on the radiated power spectrum versus k{sub //} computed by means of the coupling code ANTITER II remains small for the considered cases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical investigation of shock interaction with one-dimensional transverse array of particles in air

In this paper, we present numerical simulations of shock propagation in air over a one-dimensional transverse array of particles. Simulations are carried out by varying the particle spacing and shock Mach number. We compute the unsteady inviscid drag coefficient as a function of time and make relevant comparisons to that for a single particle. We find that deviations in the drag coefficient in time from that of a single particle can be correlated to the acoustic-particle interaction time. Finally, we investigate and classify the interaction of the bow shocks in front of the transverse array of particles.

42 ENGINEERING↗

Compact and multi-view solid state neutral particle analyzer arrays on National Spherical Torus Experiment-Upgrade

A compact and multi-view solid state neutral particle analyzer (SSNPA) diagnostic based on silicon photodiode arrays has been successfully tested on the National Spherical Torus Experiment-Upgrade. The SSNPA diagnostic provides spatially, temporally, and pitch-angle resolved measurements of fast-ion distribution by detecting fast neutral flux resulting from the charge exchange (CX) reactions. The system consists of three 16-channel subsystems: t-SSNPA viewing the plasma mid-radius and neutral beam (NB) line #2 tangentially, r-SSNPA viewing the plasma core and NB line #1 radially, and p-SSNPA with no intersection with any NB lines. Due to the setup geometry, the active CX signals of t-SSNPA and r-SSNPA are mainly sensitive to passing and trapped particles, respectively. In addition, both t-SSNPA and r-SSNPA utilize three vertically stacked arrays with different filter thicknesses to obtain coarse energy information. The experimental data show that all channels are operational. The signal to noise ratio is typically larger than 10, and the main noise is x-ray induced signal. The active and passive CX signals are clearly observed on t-SSNPA and r-SSNPA during NB modulation. The SSNPA data also indicate significant losses of passing particles during sawteeth, while trapped particles are weakly affected. Fluctuations up to 120 kHz have been observed on SSNPA, and they are strongly correlated with magnetohydrodynamics instabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗