Search NASASearch

SEARCH · Search NASA

Results for “atom interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Microscopic changes governing melting anisotropy: Real-time nanosecond x-ray diffraction

To understand the microscopic origins governing melting anisotropy, in-situ x-ray diffraction (XRD) measurements were obtained in aluminum single crystals shocked along $\langle$100$\rangle$ and $\langle$110$\rangle$ to stresses below and above the melting threshold for each orientation. XRD results and analysis for the two orientations showed significant differences in the microstructure prior to the melting threshold stresses, demonstrating the key role of deformation induced microstructure – in addition to temperature and pressure – on the melting transition. As a result, our findings make a strong case for reconsidering theoretical approaches to melting, specifically for dislocation mediated melting, in shock compressed solids.

crystal melting

Atomic clocks for astrophysical measurements

It is noted that recently developed atomic hydrogen masers have achieved stability well into the 10 to the -16th domain for averaging time intervals beyond 1000 sec and that further improvements are in prospect. These devices are highly adaptable for space use in very high precision measurements of angle through Very Long Baseline Interferometry (VLBI) and of range and range-rate through Doppler techniques. Space missions that will use these clocks for measuring the sun's gravity field distribution and for testing gravitation and relativity (a project that will include a search for pulsed low-frequency gravitational waves) are discussed. Estimates are made of system performance capability, and the accuracy capability of relativistic measurements is evaluated in terms of the results from the 1976 NASA/SAO spaceborne clock test of the Einstein Equivalence Principle.

Vessot, R. F. C.

Transformation from proper time on earth to coordinate time in solar system barycentric space-time frame of reference

An expression was derived for the time transformation t - tau, where t is coordinate time in the solar system barycentric space-time frame of reference and tau is proper time obtained from a fixed atomic clock on earth. This transformation is suitable for use in the computation of high-precision earth-based range and Doppler observables of a spacecraft or celestial body located anywhere in the solar system; it can also be used in obtaining computed values of very long baseline interferometry data types. The formulation for computing range and Doppler observables, which is an explicit function of the transformation t - tau, is described briefly.

Moyer, T. D.

A relativistic analysis of clock synchronization

The relativistic conversion between coordinate time and atomic time is reformulated to allow simpler time calculations relating analysis in solar-system barycentric coordinates (using coordinate time) with earth-fixed observations (measuring earth-bound proper time or atomic time.) After an interpretation of terms, this simplified formulation, which has a rate accuracy of about 10 to the minus 15th power, is used to explain the conventions required in the synchronization of a world wide clock network and to analyze two synchronization techniques-portable clocks and radio interferometry. Finally, pertinent experiment tests of relativity are briefly discussed in terms of the reformulated time conversion.

Thomas, J. B.

Orbiting Deep Space Relay Station (ODSRS): DSN feasibility study report

Future tracking requirements and advantages over earth based stations justify the design of an orbiting, free flying very long base interferometry system to provide high resolution maps of celestial radio sources. Moderate technology development is required for the following: 30 meter to 60 meter diameter deployable parabolic antennas with less than 2 millimeters surface tolerance; a momentum wheel attitude control system with few arc/second accuracy; solar power design; a hydrogen maser atomic frequency standard; and the cryogenic receivers. The system must meet current Deep Space tracking capabilities as a minimum, and the technology must be compatible with system performance growth in the future. System lifetime must be ten years without major refurbishing.

Thornton, T.

Reformulation of the relativistic conversion between coordinate time and atomic time

The relativistic conversion between coordinate time and atomic time is reformulated to allow simpler time calculations relating analysis in solar system barycentric coordinates (using coordinate time) with earth-fixed observations (measuring 'earth-bound' proper time or atomic time). After an interpretation in terms of relatively well-known concepts, this simplified formulation, which has a rate accuracy of about 10 to the minus 15th, is used to explain the conventions required in the synchronization of a worldwide clock network and to analyze two synchronization techniques - portable clocks and radio interferometry. Finally, pertinent experimental tests of relativity are briefly discussed in terms of the reformulated time conversion.

Thomas, J. B.

Independent Technical Assessment of NASA and External Quantum Sensing Capability

The recent FY 2020 federal Research and Development Budget Priorities memo addresses the leadership need in Quantum Information Science (QIS) directing agencies to “prioritize QIS research and development (R&D), which will build the technical and scientific base necessary to explore the next generation of QIS theory, devices, and applications.” Quantum Sensing (QS) is an integral part of QIS. NASA is a key part of the directive to forward American space exploration and commercialization by providing “capabilities that have broad potential applications in space and on Earth.” QS provides an arena for NASA to demonstrate leadership in both areas of the administrative directive. QS uses quantum properties to achieve unprecedented measurement sensitivity and performance, including quantum-enhanced methodologies that outperform their classical counterparts. Typical quantum sensors exploit techniques such as atomic systems, matter waves, quantum entanglement, quantum superposition of states, quantum illumination methods, and manipulation of photons and atoms, in general. Guided by advancements in our ability to generate, manipulate, and control quantum systems, the emerging quantum sensing technologies promise unrivalled sensitivity, resolution, and precision, potentially leading to game-changing applications. Significant gains include technologies important for a range of NASA missions such as remote sensing, in situ measurements, metrology, interferometry, quantum communication, ranging, imaging, radar and lidar receivers, and gravity measurements. NASA Engineering and Safety Center has convened an independent external panel, comprising of Quantum Sensing Experts from Government, DoD, academia, and Federally funded Research and Development Center to conduct an independent technical assessment of the agency's capabilities in Quantum Sensing to understand NASA's internal needs and competencies related to Quantum Sensing and compare agency capabilities with those available externally including industry, academia, and other government agencies. The outcomes of the assessment will help the agency in establishing appropriate strategies and investments to develop and maintain the state-of-the-art sensing competence and capabilities required to meet the agency’s future needs. The External Experts Panel (EEP) is collaborating with HQ, various NASA Center and the representatives in the NASA Quantum Sensing Community of Practice (QS CoP), a part of NASA Sensors and Instrumentation Technical Fellow Technical Discipline Team, in obtaining common, current understanding of agency mission needs where QS can be an important enabler for future needs, and any programs, projects, assets, and technologists working in QS. The EEP organized a Quantum Sensing Workshop of practitioners from industry, academia, other government agencies, external experts, and interested NASA personnel to gather the assessment information. EEP also conducted information gathering on the industry at large, educational institutions, and other government agency research efforts for capture in the assessment database. At the conclusion of this assessment, EEP team will develop findings and conclusions describing NASA’s capabilities for the mission needs, NASA's relative position on new, enabling technologies, and an analysis of the gaps that may present any risks to near-term or far-term mission needs. This presentation will give details of the NASA and External Quantum Sensing Assessment outcomes, findings, observations, and its recommendation to NASA as how it can advance Quantum Sensing technologies and techniques for its science and explorations related missions.

External Quantum Sensing Capability

Quantum Interferometry

Recently, several researchers, including yours truly, have been able to demonstrate theoretically that quantum photon entanglement has the potential to also revolutionize the entire field of optical interferometry, by providing many orders of magnitude improvement in interferometer sensitivity. The quantum entangled photon interferometer approach is very general and applies to many types of interferometers. In particular, without nonlocal entanglement, a generic classical interferometer has a statistical-sampling shot-noise limited sensitivity that scales like 1/Sqrt[N], where N is the number of particles (photons, electrons, atoms, neutrons) passing through the interferometer per unit time. However, if carefully prepared quantum correlations are engineered between the particles, then the interferometer sensitivity improves by a factor of Sqrt[N] (square root of N) to scale like 1/N, which is the limit imposed by the Heisenberg Uncertainty Principle. For optical (laser) interferometers operating at milliwatts of optical power, this quantum sensitivity boost corresponds to an eight-order-of-magnitude improvement of signal to noise. Applications are to tests of General Relativity such as ground and orbiting optical interferometers for gravity wave detection, Laser Interferometer Gravity Observatory (LIGO) and the European Laser Interferometer Space Antenna (LISA), respectively.

Dowling, Jonathan P.

Using GPS and VLBI technology to maintain 14 digit synchronization

To facilitate the navigation of spacecraft to the outer planets, Jupiter and beyond, the JPL-NASA Deep Space Network (DSN) has implemented three ensembles of atomic clocks at widely separated locations. These clocks must be maintained, synchronized, to with a few parts in 10 to the 13th power of each other and, the entire group must be maintained, to a lesser degree, in synchronism with Coordinated Universal Time (UTC)NBS/USNO. Over the last 1 1/2 years the DSN has been using Global Positioning Satellites (GPS) and Very Long Baseline Interferometry (VLBI) technology to perform these critical Frequency and Time (F&T) synchronization tasks. A year of F&T synchronization data collected from the intercomparison of 3 sets of cesium and hydrogen maser driven clock ensembles through the use of GPS and VLBI techniques are covered. Also covered, are some of the problems met and limitations of these two techniques at their present level of technology.

Ward, S. C.

High-Power Clock Laser Spectrally Tailored for High-Fidelity Quantum State Engineering

Highly frequency-stable lasers are ubiquitous tools for optical-frequency metrology, precision interferometry, and quantum information science. While making a universally applicable laser is unrealistic, spectral noise can be tailored for specific applications. Here we report a high-power 698-nm clock laser with a maximum output of 4W and minimized frequency noise up to a few kHz Fourier frequency, together with long-term instability of 3.5 × 10 −17 at one to thousands of seconds. The laser-frequency noise is precisely characterized with atom-based spectral analysis that employs a pulse sequence designed to suppress sensitivity to intensity noise. This method provides universally applicable tunability of the spectral response and analysis of quantum sensors over a wide frequency range. With the optimized laser system characterized by this technique, we achieve an average single-qubit Clifford gate fidelity of up to 𝐹$^2_1$ = 0.999⁢64⁢(3) when simultaneously driving 3000 optical qubits with a homogeneous Rabi frequency ranging from 10 Hz to 1 kHz. This result represents the highest single optical-qubit-gate fidelity for a large number of atoms.

atomic gases

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER

Fast quantum interferometry at the nanometer and attosecond scales with energy-entangled photons

In classical optical interferometry, loss and background complicate achieving fast nanometer-resolution measurements with illumination at low light levels. Conversely, quantum two-photon interference is unaffected by loss and background, but nanometer-scale resolution is physically difficult to realize. As a solution, we enhance two-photon interference with highly nondegenerate energy entanglement featuring photon frequencies separated by 177 THz. We observe measurement resolution at the nanometer (attosecond) scale with only O(10 4 ) photon pairs, despite the presence of background and loss. Our nondestructive thickness measurement of a metallic thin film agrees with atomic force microscopy, which often achieves better resolution via destructive means. With contactless, nondestructive measurements in seconds or faster, our instrument enables metrological studies in optically challenging contexts where background, loss, or photosensitivity are factors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

Topography restoration in white-light interferometry using an instrument transfer function evaluated with binary pseudo-random arrays

Accurate knowledge of the instrument transfer function (ITF) is vital for topography measurements using white-light interferometry (WLI). To this end, we derive a complete set of analytical expressions for the power spectral density (PSD) of a discretely sampled binary pseudo-random array (BPRA) as a theoretical benchmark. We then determine the ITF by comparing this theoretical PSD with the measured PSD of the BPRA. For the Zygo ZeGage Pro HR with a objective, the determined ITF closely matches the nominal modulation transfer function (MTF). Accordingly, we integrate the nominal MTF into Fourier-domain restoration filters and apply them to practical WLI topography data, yielding restored topographies that show improved agreement with atomic force microscopy measurements. Overall, our integrated BPRA-based ITF measurement and filtering methodology offers a robust yet practical means of characterizing WLI performance and enhancing the accuracy of surface measurements.

Hirose, Shigenobu [Japan Agency for Marine Earth S

Application of two-component phase Doppler interferometry to the measurement of particle size, mass flux, and velocities in two-phase flows

Two-component phase Doppler interferometry is described, along with its application for the spatially-resolved measurements of particle size, velocity, and mass flux as well as continuous phase velocity. This technique measures single particle events at a point in the flow; droplet size is deduced from the spatial phase shift of the Doppler signal. Particle size influence and discrimination of continuous and discrete phases are among issues covered. Applications are presented for four cases: an example of the discrimination of two sizes of glass beads in a jet flow; a demonstration of the discrimination of phases in a spray field; an assessment of atomizer symmetry with respect to fuel distribution; and a characterization of a droplet field in a reacting spray. It is noted that the above technique is especially powerful in delineating droplet interactions in the swirling, complex flows typical of realistic systems.

Mcdonell, V. G.

Redefining precision interferometry and spectroscopy with high-performance optical interference coatings

High-performance optical interference coatings have transformed precision interferometry and spectroscopy by enabling unparalleled control over light–matter interactions. This review explores recent innovations in ion-beam sputtered amorphous dielectric, as well as substrate-transferred crystalline coatings, and their impact on systems at the forefront of precision metrology. These state-of-the-art coating techniques generate multilayers with ultralow optical losses, yielding mirrors with exceptional reflectivity. Refinements in their noise performance push the ultimate limits of sensitivity, resolution, and stability in demanding laser-based metrology applications. These technologies underpin the most advanced timekeeping and spatial measurement tools, enabling high-finesse reference cavities for the world’s most precise optical atomic clocks and low-noise reflective test masses for km-baseline gravitational-wave detectors. Emerging hybrid designs combining these techniques expand access to the mid-infrared spectral region, enabling the first ultralow-optical-loss coatings in the 3000–5000 nm wavelength range for enhanced spectroscopy and trace-gas detection. We highlight how these technologies redefine coating performance metrics and set new benchmarks in quantum science, fundamental physics, and precision optical sensing.

Cole, Garrett D. [University of Arizona, Tucson, A

Particle balance of deuterium during deuterium shattered pellet injection shutdown in DIII-D

A particle balance analysis was conducted during a deuterium (D 2 ) shattered pellet injection-induced plasma shutdown on the DIII-D tokamak to determine why less than 20% of the pellet material is assimilated into the core plasma by the mid-current quench (CQ). Initially, most of the D 2 is injected as frozen shards and ionized upon entering the vessel. During the thermal quench, ionized particles move to the divertors and subsequently to the center post (CP) walls, where they rapidly recycle and partially accumulate as neutrals without assimilating into the core plasma. In contrast, the particle flux to the outer midplane walls is negligible, despite being accompanied by hot plasma with electron temperatures exceeding 100 eV. During mid-CQ, volume recombination effects, although not large enough to impact overall particle balance, were significant enough to require accounting for accurate interpretation of fast-framing camera D-alpha signals and the estimation of the CP wall particle flux. In addition, toroidal asymmetries, observed in measurements of toroidal electron density perturbations and the phase of magnetohydrodynamic modes, are present throughout the shutdown and can account for a discrepancy in the assimilation rate for up to 50% of the observed D 2 particle inventory. These sources and sinks of particles and fluxes were identified using absolutely calibrated D-alpha brightness and Langmuir probes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Neutron-producing gas puff Z-pinch experiments on a fast, low-impedance, 0.5 MA linear transformer driver

A study on the neutron production from single and double gas puff Z-pinches on the CESZAR linear transformer driver with ~0.45 MA current and 170 ns rise time is presented. Total neutron yield measurements made with a LaBr activation detector are compared for three configurations, using a double nozzle setup. When a single, hollow, deuterium gas shell was used, reliable implosions could only be attained at higher load mass than the optimal value to match implosion time with the driver rise time, with neutron yields of ~10 6 per pulse. The use of a double gas puff configuration with a deuterium center jet allowed a reduction in the shell density and operation closer to machine-matched conditions, recording up to (4.1 ± 0.3) × 10 7 neutrons/pulse when either Kr or D 2 was used in the shell. For a comparable mass and implosion time, using a higher atomic-number gas in the outer shell results in more unstable plasma surface and smaller plasma radius at the location of instability bubbles, which, however, do not seem to consistently correlate with a higher neutron yield. Comparing implosion dynamics with models and neutron yields with literature scaling suggests that the machine current is not well coupled to the plasma during the final stages of compression. Optimizing current and energy coupling to the pinched plasma is critical to improving performance, particularly in low-impedance drivers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY