Search NASA⌕ Search

SEARCH · Search NASA

Results for “atomic spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development of acceptance criteria for batches of silane primer for external tank thermal protection system bonding applications

Concluding tests for the thermogravimetric and FTIR analyses of DC 1200 silane primers are discussed as well as methods for HPLC and GC analyses and for determining titanium and silicon by atomic absorption spectroscopy. Tables summarizes results obtained for residue, ash, titanium, silicone, Si/Ti ratio, OH-absorption, the lap-shear test, and the GC headspace for alcohols.

Mikes, F.↗

Discoloration of poly(vinyl butyral) in cells exposed to real and simulated solar environments

The discoloration of poly(vinl butyral) (PVB) films used in solar cell modules is described. Transmission absorption, Fourier transformation IR absorption and atomic absorption spectroscopy as well as scanning electron microscopy were used for this study. The discoloration of the PVB has been found to be affected by oxygen, moisture, temperature and light. However, the most severe discoloration observed is clearly associated with the migration of positive silver ions, which can be accelerated in the presence of electric fields. The metallization is the source of the silver, and the data are consistent with an interfacial reaction between the silver and PVB followed by transport into the polymer.

Kim, Q.↗

Laboratory studies of the deposition of alkali sulfate vapors from combustion gases using a flash-evaporation technique

A relatively simple experimental technique is proposed and demonstrated for making measurements of absolute dewpoints and relative deposition rates from flowing combustion gases containing condensible inorganic vapors. The method involves first accumulating condensate on a Pt ribbon target maintained below the dewpoint and then flash-evaporating the condensate into the filament wake, where its alkali content is monitored by alkali-atom emission spectroscopy. The advantages of the method over others are demonstrated; in particular, the method can detect liquid condensate inventories which are small enough to be negligibly influenced by surface runoff produced by gas-side shear stress and liquid condensate surface tension gradients. Illustrative Na2SO4 and K2SO4 deposition rate data and corresponding dewpoint data obtained in a series of alkali-seeded propane/air atmospheric flames are presented and discussed.

Rosner, Daniel E.↗

The Building Blocks of Materials: Gathering Knowledge at the Molecular Level

Two start-up positions were created within SD46 to pursue developments in the rapidly expanding areas of biomineralization and nano-technology. As envisioned by Dr. Sandor Lehoczy, the new laboratories to be developed must have the capacity to investigate not only processes associated with the self-assembly of molecules but also the examination of self-assembled structures. For these purposes, laboratories capable of performing the intended function, particularly light scattering spectroscopy and atomic force microscopy were created. What follows then are recent advances arising from the development of these new laboratories. With the implementation of the Atomic Force Microscopy Facility, examples of investigations that determine a correlation between the molecular structure of materials and their macroscopic physical properties are provided. In addition, examples of investigations with particular emphasis on the physical properties of protein crystals, at the molecular level, and subsequent macroscopic characteristics are as provided. Finally, progress in fabrication of technology at the nano-scale levels at the developmental stage is also presented.

Source record↗

The role of biomineralization in microbiologically influenced corrosion

Synthetic iron oxides (goethite, alpha-FeO.OH; hematite, Fe2O3; and ferrihydrite, Fe(OH)3) were used as model compounds to simulate the mineralogy of surface films on carbon steel. Dissolution of these oxides exposed to pure cultures of the metal-reducing bacterium, Shewanella putrefaciens, was followed by direct atomic absorption spectroscopy measurement of ferrous iron coupled with microscopic analyses using confocal laser scanning and environmental scanning electron microscopies. During an 8-day exposure the organism colonized mineral surfaces and reduced solid ferric oxides to soluble ferrous ions. Elemental composition, as monitored by energy dispersive x-ray spectroscopy, indicated mineral replacement reactions with both ferrihydrite and goethite as iron reduction occurred. When carbon steel electrodes were exposed to S. putrefaciens, microbiologically influenced corrosion was demonstrated electrochemically and microscopically.

Non-programmatic↗

Method for Impeding Degradation of Porous Silicon Structures

This invention relates to surface modification of porosified silicon (pSi) structures with poly(alkylene) glycols for the purpose of controlled degradation of the silicon matrix and tailored release of encapsulated substances for biomedical applications. The pSi structures are currently used in diverse biomedical applications including bio-molecular screening, optical bio-sensoring, and drug delivery by means of injectable/orally administered carriers and implantable devices. The size of the pores and the surface chemistry of the pSi structure can be controlled during the microfabrication process and thereafter. A fine regulation of the degradation kinetics of mesoporous silicon structures is of fundamental importance. Polyethylene glycols (PEGs) represent the major category of surface modifying agents used in classical drug delivery systems and in pharmaceutical dosage forms. PEGylation enables avoidance of RES uptake, thus prolonging circulation time of intravenously injectable nanovectors. PEG molecules demonstrate little toxicity and immunogenicity, and are cleared from the body through the urine (molecular weight, MW less than 30 kDa) or in the feces (MW greater than 30kDa). The invention focuses on the possibility of finely tuning the degradation kinetics of the pSi nanovectors and other structures through surface conjugation of PEGs with various backbone lengths/MWs. To prove the concept, pSi nanovectors were covalently conjugated to seven PEGs with MW from 245 to 5,000 Da and their degradation kinetics in physiologically relevant media (phosphate buffer saline, PBS pH7.4, and fetal bovine serum) was assessed by the elemental analysis of the Si using inductive coupled plasma atomic emission spectroscopy (ICP-AES). The conjugation of the PEG with lowest MW to the nanovectors surface did not induce any change in the degradation kinetics in serum, but inhibited degradation and consequently the release of orthosilicic acid into buffer. When PEGs with the longer chains were evaluated, Si mass loss from the nanovectors was slowed down, and the PEGylated structures were almost fully degraded within 18 24 hours in serum and within 48 hours in PBS. The most dramatic effect was observed for high MW PEGs 3,400 and 5,000 Da, which prominently inhibited the degradation of the systems, with complete degradation achieved only after four days. For these PEGs, during the early stages of the degradation, there was a lag period of little or no Si mass loss from the nanovector. The obtained profiles were in agreement with the erosion of the nanovector surface as observed by scanning electron microscopy.

Vilentchouk, Biana Godin↗

JWST Noise Floor. I. Random Error Sources in JWST NIRCam Time Series

James Webb Space Telescope (JWST) transmission and emission spectra will provide invaluable glimpses of transiting exoplanet atmospheres, including possible biosignatures. This promising science from JWST, however, will require exquisite precision and understanding of systematic errors that can impact the time series of planets crossing in front of and behind their host stars. Here, we provide estimates of the random noise sources affecting JWST Near-Infrared Camera (NIRCam) time-series data on the integration-to-integration level. We find that 1/ f noise can limit the precision of grism time series for two groups (230–1000 ppm depending on the extraction method and extraction parameters) but will average down like the square root of N frames/reads. The current NIRCam grism time-series mode is especially affected by 1/ f noise because its GRISMR dispersion direction is parallel to the detector fast-read direction, but could be alleviated in the GRISMC direction. Care should be taken to include as many frames as possible per visit to reduce this 1/ f noise source: thus, we recommend the smallest detector subarray sizes one can tolerate, four output channels, and readout modes that minimize the number of skipped frames (RAPID or BRIGHT2). We also describe a covariance-weighting scheme that can significantly lower the contributions from 1/ f noise as compared to sum extraction. We evaluate the noise introduced by preamplifier offsets, random telegraph noise, and high dark current resistor capacitor (RC) pixels and find that these are correctable below 10 ppm once background subtraction and pixel masking are performed. We explore systematic error sources in a companion paper.

Exoplanet atmospheres↗

The Mid-Infrared Molecular Inventory Towards Orion IRc2

We present the first high spectral resolution mid-infrared survey in the Orion BN/KL region, covering 7.2 to 28.3μm. With SOFIA/EXES we target the enigmatic source Orion IRc2. While this is in the most prolifically studied massive star-forming region, longer wavelengths and molecular emission lines dominated previous spectral surveys. The mid-infrared observations in this work access different components and molecular species in unprecedented detail. We unambiguously identify two new kinematic components, both chemically rich with multiple molecular absorption lines. The “blue clump” has ν LSR = −7.1 ± 0.7 km s −1 and the “red clump” 1.4 ± 0.5 km s −1 . While the blue and red clump shave similar temperatures and line widths, molecular species in the blue clump have higher column densities. They are both likely linked to pure rotational H 2 emission also covered by this survey. This work provides evidence for the scenario that the blue and red clumps are distinct components unrelated to the classic components in the Orion BN/KL region. Comparison to spectroscopic surveys towards other infrared targets in the region show that the blue clump is clearly extended. We analyze, compare, and present in depth findings on the physical conditions of C 2 H 2 , 13 CCH 2 , CH 4 , CS, H 2 O, HCN, H 13 CN, HNC, NH 3 , and SO 2 absorption lines and an H 2 emission line associated with the blue and red clumps. We also provide limited analysis of H 2 O and SiO molecular emission lines towards Orion IRc2 and the atomic forbidden transitions [FeII], [SI], [SIII], and [NeII].

Atomic spectroscopy↗

Additional Trials & Tribulations in Synthesizing a Sulfide Standard

Well-characterized sulfide reference materials that can serve as matrix-matched calibrants for in-situ trace element analyses via laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) remain elusive. Here, we describe the creation an in-house sulfide standard at NASA JSC that will be used to measure siderophile and chalcophile trace elements in low pressure experimental products, specifically pentlandite ([FeNi]9S8) and pyrrhotite ([FeNi]1-xS), as well as natural sulfides in terrestrial and meteoritic mineral assemblages. Recent methods in creating a homogenous sulfide standard include pressed pellets, synthesized chips, or fused glass [e.g. 1-3]. Other studies, however, have had success in forming homogenous FeS standards via synthesization methods [e.g. 4-6]. We present a variation of the method described in [4], in which we create a pyrrhotite standard doped with a variety of trace elements (Zn, As, Se, Mo, Ru, Rh, Pd, Sn, Sb, Te, W, Os, Ir, Pt, Au) at ~10-40 ppm and Cu at ~200 ppm. Sulfide compositions were constructed using Fe and Ni metal and elemental sulfur powders. Trace elements were added to elemental sulfur from Atomic Absorption Spectroscopy (AAS) elemental standards as either nitrate or chloride solutions to prevent oxidation of the metal powders. The dried sulfur mixture was mixed with Fe and Ni powders and mechanically mixed before two aliquots were placed in separate SiO2 tubes. Each tube was held under vacuum for ~30 minutes, sealed under vacuum, and then heated at 800C for 48 hours. Like [4], the synthesis products were composed of pourous sulfide crystals. Major element analyses of both experimental aliquots, collected using an Electron Probe Microanalyser (EPMA), yield indistinguishable major element compositions (uncertainties in 2SE & 2RSE[%]), with an average of 57.90  0.09 (0.16 %), 4.95  0.03 (0.55 %), and 39.70  0.14 (0.34 %), for Fe, Ni, and S, respectively. Trace element data were measured using a Photon Machines 193nm laser ablation system coupled to a Thermo-Scientific Element-XR ICP-MS. Spot sizes were limited to 50 μm due to the porous nature of the sulfide target material. Trace element abundances, normalized to Fe as an internal standard, were also found to be homogenous between the two aliquots, with weighted mean 2RSE (%) values of <3.0 for all trace elements. Synthesized products were re-powdered and absolute concentrations measured via solution ICP-MS. Although the sulfide appears to be homogenous, sintering experiments will be performed to more closely match the standard density to natural sulfides and minimize differences in ablation behavior. Improved density also allows for higher sensitivity (i.e. more compact target material) and larger spot sizes or traverses, as void space is eliminated. Additional major and trace element analyses on the products of the sintering experiments will be undertaken.

Jacob B Setera↗

Characterization of Additively Manufacture GRCop-42 and GRCop-84

GRCop-42 (Cu-4 at.% Cr-2 at.% Nb) is a copper-based alloy optimized for high temperature, high thermal conductivity applications such as regenerative cooled rocket engine liners. For this application, it is important to minimize contamination such as trace elements and ceramic inclusions. NASA initiated a series of ten builds by eight companies to assess the repeatability of GRCop-42 between vendors and machines. Utilizing inductively coupled plasma – atomic emission spectroscopy (ICP-AES) and energy dispersive spectroscopy (EDS) techniques allowed for identification of contaminants and quantification of their chemistry. In addition, additive manufacturing (AM) creates a unique microstructure that is often highly textured in the build (Z) direction. Electron backscattered diffraction (EBSD) was used to begin quantifying the degree of crystallographic texture in the copper matrix grains. It was also used to identify the crystallographic form of Cr2Nb, the main strengthening phase, present in the samples. Results showed the presence of ceramic inclusions, highly textured grains, and both the low and high temperature phases of Cr2Nb being present.

copper↗

Plasma Composition Measurements in an Active Region from Solar Orbiter/SPICE and Hinode/EIS

A key goal of the Solar Orbiter mission is to connect elemental abundance measurements of the solar wind enveloping the spacecraft with extreme-UV (EUV) spectroscopic observations of their solar sources, but this is not an easy exercise. Observations from previous missions have revealed a highly complex picture of spatial and temporal variations of elemental abundances in the solar corona. We have used coordinated observations from Hinode and Solar Orbiter to attempt new abundance measurements with the Spectral Imaging of the Coronal Environment (SPICE) instrument, and benchmark them against standard analyses from the EUV Imaging Spectrometer (EIS). We use observations of several solar features in active region (AR) 12781 taken from an Earth-facing view by EIS on 2020 November 10, and SPICE data obtained one week later on 2020 November 17, when the AR had rotated into the Solar Orbiter field of view. We identify a range of spectral lines that are useful for determining the transition region and low-coronal-temperature structure with SPICE, and demonstrate that SPICE measurements are able to differentiate between photospheric and coronal magnesium/neon abundances. The combination of SPICE and EIS is able to establish the atmospheric composition structure of a fan loop/outflow area at the AR edge. We also discuss the problem of resolving the degree of elemental fractionation with SPICE, which is more challenging without further constraints on the temperature structure, and comment on what that can tell us about the sources of the solar wind and solar energetic particles.

Solar physics↗

Laser Optogalvanic Spectroscopy pf Neon and Argon in a Discharge Plasma and its Significance for Microgravity Combustion

A detailed study of combustion mechanisms in flames, employing laser-based diagnostics, has provided good knowledge and understanding of the physical phenomena, and led to better characterization of the dynamical and chemical combustion processes, both under low-gravity (in space) and normal gravity (in ground based facilities, e.g. drop towers). Laser induced fluorescence (LIF), laser-induced incandescence (LII) and LIF thermometry have been widely used to perform nonintrusive measurements and to better understand combustion phenomena. Laser optogalvanic (LOG) spectroscopy has well-established applications in ion mobility measurements, atomic and molecular spectroscopy, ionization rates, recombination rates, velocity measurements and as a combustion probe for trace element detection. Absorption spectra of atomic and molecular species in flames can be obtained via LOG spectroscopy by measuring the voltage and current changes induced by laser irradiation. There are different kinds of processes that contribute to a discharge current, namely: (1) electron impact ionization, (2) collisions among the excited atoms of the discharge species and (3) Penning ionization. In general, at higher discharge currents, the mechanism of electron impact ionization dominates over Penning ionization, whereby the latter is hardly noticeable. In a plasma, whenever the wavelength of a laser coincides with the absorption of an atomic or molecular species, the rate of ionization of the species momentarily increases or decreases due to laser-assisted acceleration of collisional ionization. Such a rate of change in the ionization is monitored as a variation in the transient current by inserting a high voltage electrode into the plasma. Optogalvanic spectroscopy in discharges has been useful for characterizing laser line-widths and for providing convenient calibration lines for tunable dye lasers in the ultraviolet, visible and infrared wavelength regions. Different kinds of quantitative information, such as the electron collisional ionization rate, can be extracted from the complex processes occurring within the discharge. In the optogalvanic effect (OGE), there is no problem of overlap from background emissions, and hence even weak signals can be detected with a high signal-to-noise ratio, which makes the optogalvanic effect sensitive enough to resolve vibrational changes in molecular bonds and differences in energy levels brought about by different electron spins. For calibration purposes, neon and argon gaseous discharges have been employed most extensively, because these gases are commonly used as buffer gases within hollow-cathode lamps and provide an acceptable density of calibration lines. In the present work, our main aim has been to understand the dominant physical processes responsible for the production of the OGE signal, based on the extensive time resolved optogalvanic waveforms recorded, and also to extract quantitative information on the rates of excited state collisional processes.

Misra, Prabhakar↗

Atomic oxygen fine-structure splittings with tunable far-infrared spectroscopy

Fine-structure splittings of atomic oxygen (O-16) in the ground state have been accurately measured using a tunable far-infrared spectrometer. The 3P0-3pl splitting is 2,060,069.09 (10) MHz, and the 3Pl-3P2 splitting is 4,744,777.49 (16) MHz. These frequencies are important for measuring atomic oxygen concentration in earth's atmosphere and the interstellar medium.

Zink, Lyndon R.↗

Auger electron spectroscopy study of initial stages of oxidation in a copper - 19.6-atomic-percent-aluminum alloy

Auger electron spectroscopy was used to examine the initial stages of oxidation of a polycrystalline copper - 19.6 a/o-aluminum alloy. The growth of the 55-eV aluminum oxide peak and the decay of the 59-, 62-, and 937-eV copper peaks were examined as functions of temperature, exposure, and pressure. Pressures ranged from 1x10 to the minus 7th power to 0.0005 torr of O2. Temperatures ranged from room temperature to 700 C. A completely aluminum oxide surface layer was obtained in all cases. Complete disappearance of the underlying 937-eV copper peak was obtained by heating at 700 C in O2 at 0.0005 torr for 1 hr. Temperature studies indicated that thermally activated diffusion was important to the oxidation studies. The initial stages of oxidation followed a logarithmic growth curve.

Ferrante, J.↗

Spaceborne Photonics Institute

This report describes in chronological detail the development of the Spaceborne Photonics Institute as a sustained research effort at Hampton University in the area of optical physics. This provided the research expertise to initiate a PhD program in Physics. Research was carried out in the areas of: (1) modelling of spaceborne solid state laser systems; (2) amplified spontaneous emission in solar pumped iodine lasers; (3) closely simulated AM0 CW solar pumped iodine laser and repeatedly short pulsed iodine laser oscillator; (4) a materials spectroscopy and growth program; and (5) laser induced fluorescence and atomic and molecular spectroscopy.

Venable, D. D.↗

Continuum ionization transition probabilities of atomic oxygen

The technique of photoelectron spectroscopy was employed in the investigation. Atomic oxygen was produced in a microwave discharge operating at a power of 40 W and at a pressure of approximately 20 mtorr. The photoelectron spectrum of the oxygen with and without the discharge is shown. The atomic states can be clearly seen. In connection with the measurement of the probability for transitions into the various ionic states, the analyzer collection efficiency was determined as a function of electron energy.

Samson, J. A. R.↗