Search NASA⌕ Search

SEARCH · Search NASA

Results for “attack modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Optical methods for model angle of attack and transition measurement

A novel laser-based sensor for the in situ measurement of wind tunnel model angle of attack is described and the results of a successful demonstration in the NASA Ames 9 x 7-ft. Supersonic wind tunnel are presented. The design concepts of a scanning laser-based turbulence detector, which will enable nonintrusive, microscopic studies of the onset and extent of transition on wind tunnel test models, is also described.

Owen, F. K.↗

Extreme Temperature Cryptography Based On Nitrogen-Incorporated Ultrananocrystalline Diamond

Physical entropy sources that remain stable under extreme temperatures are essential for cryptography in emerging technological frontiers in deep space exploration, geothermal energy harvesting, and nuclear energy. However, conventional semiconductor platforms fail to generate stable and reliable cryptographic keys above 200 degrees C due to performance degradation. Here, we report a diamond-based cryptographic primitive that exploits the defect-rich sp 2 -bonded grain boundary network in nitrogen-incorporated ultrananocrystalline diamond (n-UNCD) film as a robust entropy source to generate cryptographic keys that remain operationally stable even after enduring extreme temperatures of 700 degrees C for 54 h while also surviving thermal cycling between room temperature and 700 degrees C for 48 h. The strength of the generated keys is assessed through several cryptographic metrics such as bit uniformity, entropy, hamming distances, and correlation coefficients, all of which are found to be near their respective ideal values. Moreover, the generated keys pass the NIST SP 800 and SP 800-90B tests and are also resilient to supply bias variations and a regression-based machine learning attack model based on the Fourier series. The robustness of the keys is attributed to the better thermal stability and chemical inertness of the n-UNCD film. This is supported by high-resolution energy-dispersive X-ray spectroscopy (EDS), which shows no significant lateral diffusion of metal atoms into the n-UNCD layer, and by Raman spectroscopy, which reveals no significant changes in the bonding configuration of the n-UNCD structure. Our findings highlight the remarkable potential of n-UNCD film for extreme environment cryptography by expanding the operational limits of conventional hardware security platforms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resilient State Recovery Using Prior Measurement Support Information

Resilient state recovery of cyber-physical systems has attracted much research attention due to the unique challenges posed by the tight coupling between communication, computation, and the underlying physics of such systems. By modeling attacks as additive adversary signals to a sparse subset of measurements, this resilient recovery problem can be formulated as an error correction problem. To achieve exact state recovery, most existing results require less than 50% of the measurement nodes to be compromised, which limits the resiliency of the estimators. In this paper, we show that observer resiliency can be further improved by incorporating data-driven prior information. Here, we provide an analytical bridge between the precision of prior information and the resiliency of the estimator. By quantifying the relationship between the estimation error of the weighted ℓ 1 observer and the precision of the support prior, this quantified relationship provides guidance for the estimator’s weight design to achieve optimal resiliency. Several numerical simulations and an application case study are presented to validate the theoretical claims.

24 POWER TRANSMISSION AND DISTRIBUTION↗

GridSTAGE (aka PowerDrone)

Simulation tool for electrical grid security. It is possible to select from pre-loaded power system topologies, enable different grid controls (like AGC, power system stabilizer), add faults, tweak different parameters, add pre-modeled attack scenarios, and run batch simulations to generate data needed for research.

Nandanoori, Sai Pushpak↗

Study of optical techniques for the Ames unitary wind tunnel, part 7

A summary of optical techniques for the Ames Unitary Plan wind tunnels are discussed. Six optical techniques were studied: Schlieren, light sheet and laser vapor screen, angle of attack, model deformation, infrared imagery, and digital image processing. The study includes surveys and reviews of wind tunnel optical techniques, some conceptual designs, and recommendations for use of optical methods in the Ames Unitary Plan wind tunnels. Particular emphasis was placed on searching for systems developed for wind tunnel use and on commercial systems which could be readily adapted for wind tunnels. This final report is to summarize the major results and recommendations.

Lee, George↗

Modeling and Analysis of Eavesdropping Attack in 802.11ad mmWave Wireless Networks

Next generation wireless communication networks utilizing 60 GHz millimeter wave (mmWave) frequency bands are expected to achieve multi-gigabit throughput with the use of highly directional phased-array antennas. These directional signal beams provide enhanced security to the legitimate networks due to the increased difficulties of eavesdropping. However, there still exists significant possibility of eavesdropping since 1) the reflections of the signal beam from ambient reflectors enables opportunistic stationary eavesdropping attacks, and; 2) carefully designed beam exploration strategy enables active nomadic eavesdropping attack. This paper discusses eavesdropper attack strategies for 802.11ad mmWave systems and provides the first analytical model to characterize the success possibility of eavesdropping in both opportunistic stationary attacks and active nomadic attacks. We derive the success probability of eavesdropping considering the ambient reflectors in the environment and errors introduced in the beam exploration strategies of the proposed eavesdropping attacker models. We study the success probability for both opportunistic stationary attack scenario and active nomadic attack scenario through numerical simulations. In addition to numerical simulations, we also evaluate the proposed attacker models using an 802.11ad test bed consisting of commercially available off-the-shelf devices.

99 GENERAL AND MISCELLANEOUS↗

Evaluation of electrolytic tilt sensors for measuring model angle of attack in wind tunnel tests

The results of a laboratory evaluation of electrolytic tilt sensors as potential candidates for measuring model attitude or angle of attack in wind tunnel tests are presented. The performance of eight electrolytic tilt sensors was compared with that of typical servo accelerometers used for angle-of-attack measurements. The areas evaluated included linearity, hysteresis, repeatability, temperature characteristics, roll-on-pitch interaction, sensitivity to lead-wire resistance, step response time, and rectification. Among the sensors being evaluated, the Spectron model RG-37 electrolytic tilt sensors have the highest overall accuracy in terms of linearity, hysteresis, repeatability, temperature sensitivity, and roll sensitivity. A comparison of the sensors with the servo accelerometers revealed that the accuracy of the RG-37 sensors was on the average about one order of magnitude worse. Even though a comparison indicates that the cost of each tilt sensor is about one-third the cost of each servo accelerometer, the sensors are considered unsuitable for angle-of-attack measurements. However, the potential exists for other applications such as wind tunnel wall-attitude measurements where the errors resulting from roll interaction, vibration, and response time are less and sensor temperature can be controlled.

Wong, Douglas T.↗

Large-scale wind tunnel tests of a sting-supported V/STOL fighter model at high angles of attack

A new sting model support has been developed for the NASA/Ames 40- by 80-Foot Wind Tunnel. This addition to the facility permits testing of relatively large models to large angles of attack or angles of yaw depending on model orientation. An initial test on the sting is described. This test used a 0.4-scale powered V/STOL model designed for testing at angles of attack to 90 deg and greater. A method for correcting wake blockage was developed and applied to the force and moment data. Samples of this data and results of surface-pressure measurements are presented.

Stoll, F.↗

Detection of DoS Attacks Using ARFIMA Modeling of GOOSE Communication in IEC 61850 Substations

Integration of Information and Communication Technology (ICT) in modern smart grids (SGs) offers many advantages including the use of renewables and an effective way to protect, control and monitor the energy transmission and distribution. To reach an optimal operation of future energy systems, availability, integrity and confidentiality of data should be guaranteed. Research on the cyber-physical security of electrical substations based on IEC 61850 is still at an early stage. In the present work, we first model the network traffic data in electrical substations, then, we present a statistical Anomaly Detection (AD) method to detect Denial of Service (DoS) attacks against the Generic Object Oriented Substation Event (GOOSE) network communication. According to interpretations on the self-similarity and the Long-Range Dependency (LRD) of the data, an Auto-Regressive Fractionally Integrated Moving Average (ARFIMA) model was shown to describe well the GOOSE communication in the substation process network. Based on this ARFIMA-model and in view of cyber-physical security, an effective model-based AD method is developed and analyzed. Two variants of the statistical AD considering statistical hypothesis testing based on the Generalized Likelihood Ratio Test (GLRT) and the cumulative sum (CUSUM) are presented to detect flooding attacks that might affect the availability of the data. Our work presents a novel AD method, with two different variants, tailored to the specific features of the GOOSE traffic in IEC 61850 substations. The statistical AD is capable of detecting anomalies at unknown change times under the realistic assumption of unknown model parameters. The performance of both variants of the AD method is validated and assessed using data collected from a simulation case study. We perform several Monte-Carlo simulations under different noise variances. The detection delay is provided for each detector and it represents the number of discrete time samples after which an anomaly is detected. In fact, our statistical AD method with both variants (CUSUM and GLRT) has around half the false positive rate and a smaller detection delay when compared with two of the closest works found in the literature. Our AD approach based on the GLRT detector has the smallest false positive rate among all considered approaches. Whereas, our AD approach based on the CUSUM test has the lowest false negative rate thus the best detection rate. Depending on the requirements as well as the costs of false alarms or missed anomalies, both variants of our statistical detection method can be used and are further analyzed using composite detection metrics.

IEC 61850 electrical substations↗

On the vulnerability of data-driven structural health monitoring models to adversarial attack

Many approaches at the forefront of structural health monitoring rely on cutting-edge techniques from the field of machine learning. Recently, much interest has been directed towards the study of so-called adversarial examples; deliberate input perturbations that deceive machine learning models while remaining semantically identical. This article demonstrates that data-driven approaches to structural health monitoring are vulnerable to attacks of this kind. In the perfect information or ‘white-box’ scenario, a transformation is found that maps every example in the Los Alamos National Laboratory three-storey structure dataset to an adversarial example. Also presented is an adversarial threat model specific to structural health monitoring. The threat model is proposed with a view to motivate discussion into ways in which structural health monitoring approaches might be made more robust to the threat of adversarial attack.

60 APPLIED LIFE SCIENCES↗

Electric Vehicle Charging Data Falsification Attacks Utilizing Behavioral Models

A charging station (CS) and its associated electric vehicle supply equipment (EVSE) and charging electric vehicle (EV) interactions are potential targets for data falsification attacks since CSs are typically unmanned public facilities that are connected to the internet and EVs incorporate the vulnerable CAN bus network, which are both susceptible to remote attacks. The research question being addressed is how is the EV owner and CS negatively affected by CAN bus EV battery current sensor and battery temperature sensor data falsification attacks. Negative effects include economic losses from reduced life span of the battery, battery thermal runaway and fire (and potential loss of surrounding structure), and reduced utilization of the CS due to delayed departure time (longer charging times).

25 ENERGY STORAGE↗

Low-Speed Tests of Semispan-Wing Models at Angles of Attack from 0 to 180 degrees

Semispan-wing models were tested at angles of attack from 0 to 180 deg at low subsonic speeds. Eight plan forms were considered, both swept and unswept with aspect ratios ranging from 2 to 6. Except for a delta-wing model of aspect ratio 2. all models had a taper ratio of 0.5 and an NACA 64AO10 airfoil section. The delta-wing model had an NACA 0005 (modified) airfoil section. With two exceptions, the models were tested both with and without a full-span trailing-edge flap deflected 25 deg. The Reynolds numbers based on the mean aerodynamic chord were between 1.5 and 2.2 million. Lift, drag, and pitching-moment coefficients are presented as functions of angle of attack. Approximate corrections for the effects of blockage were applied to the data.

Koenig, David G.↗

Low-speed aerodynamic characteristics of a 1/8-scale X-29A airplane model at high angles of attack and sideslip

A 1/8-scale model of the X-29A airplane was tested in the Ames 12-Foot Pressure Wind Tunnel at a Mach number of 0.20 and Reynolds numbers of 0.13 x 10 to the 6th power to 2.00 x 10 to the 6th power based on a fuselage forebody depth of 0.4 ft, For the test series presented herein, the angle of attack ranged from 40 deg. to 90 deg. and the angle of sideslip ranged from -10 deg. to 30 deg. for the erect attitude. Tests with the model inverted covered angles of attack from -40 deg. to -90 deg. and angles of sideslip from -30 deg. to 10 deg. Data were obtained for the basic design and for several forebody strakes. An alternate forebody design was also tested. The results provided information for selection of forebody strakes for compensation of Reynolds number effect on the 1/25-scale free-spinning model tested in the Langley Spin Tunnel.

Whipple, R. D.↗

Model-Based Detection of Coordinated Attacks (DCA) in Distribution Systems

The fast-paced growth in digitization of smart grid components enhances system observability and remote-control capabilities through efficient communication. However, enhanced connectivity results in heightened system vulnerability towards cybersecurity risks in the cyber-physical power system. Coordinated cyber-attacks (CCA), when undetected, lead to system-wide impact in terms of large disturbances or widespread outages. Detecting CCA in the cyber layer is critical to thwart cyber-attacks in real-time before the attack impacts the physical system. The challenge of locating CCA stems from the complex grid dynamics, making it difficult to distinguish between normal operational variations and cyber-attack impact. CCA often employs multiple attack vectors targeting geographically distributed components, further complicating CCA identification. Existing research in intrusion detection is primarily focused on the transmission network and limited to detecting individual attacks. In this paper, a novel proactive DCA strategy is proposed for early detection of CCA by establishing correlations among distinct attack events through model-based reinforcement learning that utilizes abductive reasoning to conclude the attacker goal. The solution includes understanding the system model, learning the system dynamics, and correlating individual cyber-attacks to extract the attacker’s objective. The developed learning algorithm identifies the most probable attack path to reach the attacker’s objective by predicting the next attack steps. A DNP3-based cyber-physical co-simulation testbed is developed to test the proposed algorithm using the IEEE 13-node test feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spin-Tunnel Investigation of a 1/28-Scale Model of a Subsonic Attack Airplane

An investigation has been made of a 1/28-scale model of the Grumman A-6A airplane in the Langley spin tunnel. The erect spin and recovery characteristics of the model were determined for the flight design gross weight loading and for a loading with full internal fuel and empty external wing fuel tanks. The effects of extending slats and deflecting flaps were investigated. Inverted-spin and recovery characteristics of the model were determined for the flight design gross weight loading. The size of the spin-recovery tail parachute necessary to insure satisfactory spin-recovery was determined, and the effect of firing wing-mounded rockets during spins was investigated.

Lee, Henry A.↗

Model-based Cyber-attack Detection for Voltage Source Converters in Island Microgrids

With the upgrading of communication and control in microgrids, cyber threats on the power converters are increasing. Here, in this paper, a novel model-based cyber-attack detection methodology is proposed for each voltage source converter in microgrids. The Harmonics State Space Matrix (H-Matrix) is used to build the closed-loop transfer function, providing model-based estimation with the grid voltage and control reference. Then, the space phase model (SPM) is used to calculate residual to detect cyber-attacks in voltage source converter (VSC). As controller and converter parameters are included in the H-matrix, the proposed method also could detect cyber-attacks when voltage fluctuation occurs in the grid. To verify the feasibility of the proposed method, several attacks targeting VSC in an islanded microgrid are simulated in MATLAB. Simulation and detection results are introduced to demonstrate the resilience and feasibility of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗