Search NASA⌕ Search

SEARCH · Search NASA

Results for “auditory perception”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

61 records · Page 4

Gravitoinertial force magnitude and direction influence head-centric auditory localization

We measured the influence of gravitoinertial force (GIF) magnitude and direction on head-centric auditory localization to determine whether a true audiogravic illusion exists. In experiment 1, supine subjects adjusted computer-generated dichotic stimuli until they heard a fused sound straight ahead in the midsagittal plane of the head under a variety of GIF conditions generated in a slow-rotation room. The dichotic stimuli were constructed by convolving broadband noise with head-related transfer function pairs that model the acoustic filtering at the listener's ears. These stimuli give rise to the perception of externally localized sounds. When the GIF was increased from 1 to 2 g and rotated 60 degrees rightward relative to the head and body, subjects on average set an acoustic stimulus 7.3 degrees right of their head's median plane to hear it as straight ahead. When the GIF was doubled and rotated 60 degrees leftward, subjects set the sound 6.8 degrees leftward of baseline values to hear it as centered. In experiment 2, increasing the GIF in the median plane of the supine body to 2 g did not influence auditory localization. In experiment 3, tilts up to 75 degrees of the supine body relative to the normal 1 g GIF led to small shifts, 1--2 degrees, of auditory setting toward the up ear to maintain a head-centered sound localization. These results show that head-centric auditory localization is affected by azimuthal rotation and increase in magnitude of the GIF and demonstrate that an audiogravic illusion exists. Sound localization is shifted in the direction opposite GIF rotation by an amount related to the magnitude of the GIF and its angular deviation relative to the median plane.

NASA Discipline Neuroscience↗

The impacts of training on change deafness and build-up in a flicker task

Performance on auditory change detection tasks can be improved by training. We examined the stimulus specificity of these training effects in behavior and ERPs. A flicker change detection task was employed in which spatialized auditory scenes were alternated until a "change" or "same" response was made. For half of the trials, scenes were identical. The other half contained changes in the spatial locations of objects from scene to scene. On Day 1, participants were either trained on this auditory change detection task (trained group), or trained on a non-auditory change detection task (control group). On Day 2, all participants were tested on the flicker task while EEG was recorded. The trained group showed greater change detection accuracy than the control group. They were less biased to respond "same" and showed full generalization of learning from trained to novel auditory objects. ERPs for "change" compared to "same" trials showed more negative going P1, N1, and P2 amplitudes, as well as a larger P3b amplitude. The P3b amplitude also differed between the trained and control group, with larger amplitudes for the trained group. Analysis of ERPs to scenes viewed prior to a decision revealed build-up of a difference between "change" and "same" trials in N1 and P2. Results demonstrate that training has an impact early in the "same" versus "change" decision-making process, and that the flicker paradigm combined with the ERP method can be used to study the build-up of change detection in auditory scenes.

60 APPLIED LIFE SCIENCES↗

Visual Image Sensor Organ Replacement

This innovation is a system that augments human vision through a technique called "Sensing Super-position" using a Visual Instrument Sensory Organ Replacement (VISOR) device. The VISOR device translates visual and other sensors (i.e., thermal) into sounds to enable very difficult sensing tasks. Three-dimensional spatial brightness and multi-spectral maps of a sensed image are processed using real-time image processing techniques (e.g. histogram normalization) and transformed into a two-dimensional map of an audio signal as a function of frequency and time. Because the human hearing system is capable of learning to process and interpret extremely complicated and rapidly changing auditory patterns, the translation of images into sounds reduces the risk of accidentally filtering out important clues. The VISOR device was developed to augment the current state-of-the-art head-mounted (helmet) display systems. It provides the ability to sense beyond the human visible light range, to increase human sensing resolution, to use wider angle visual perception, and to improve the ability to sense distances. It also allows compensation for movement by the human or changes in the scene being viewed.

Maluf, David A.↗

Structural determinants of protocadherin-15 mechanics and function in hearing and balance perception

The vertebrate inner ear, responsible for hearing and balance, is able to sense minute mechanical stimuli originating from an extraordinarily broad range of sound frequencies and intensities or from head movements. Integral to these processes is the tip-link protein complex, which conveys force to open the inner-ear transduction channels that mediate sensory perception. Protocadherin-15 and cadherin-23, two atypically large cadherins with 11 and 27 extracellular cadherin (EC) repeats, are involved in deafness and balance disorders and assemble as parallel homodimers that interact to form the tip link. Here we report the X-ray crystal structure of a protocadherin-15 + cadherin-23 heterotetrameric complex at 2.9-Å resolution, depicting a parallel homodimer of protocadherin-15 EC1-3 molecules forming an antiparallel complex with two cadherin-23 EC1-2 molecules. In addition, we report structures for 10 protocadherin-15 fragments used to build complete high-resolution models of the monomeric protocadherin-15 ectodomain. Molecular dynamics simulations and validated crystal contacts are used to propose models for the complete extracellular protocadherin-15 parallel homodimer and the tip-link bond. Steered molecular dynamics simulations of these models suggest conditions in which a structurally diverse and multimodal protocadherin-15 ectodomain can act as a stiff or soft gating spring. These results reveal the structural determinants of tip-link–mediated inner-ear sensory perception and elucidate protocadherin-15’s structural and adhesive properties relevant in disease.

59 BASIC BIOLOGICAL SCIENCES↗

Engineering Data Compendium. Human Perception and Performance, Volume 1

The concept underlying the Engineering Data Compendium was the product an R and D program (Integrated Perceptual Information for Designers project) aimed at facilitating the application of basic research findings in human performance to the design of military crew systems. The principal objective was to develop a workable strategy for: (1) identifying and distilling information of potential value to system design from existing research literature, and (2) presenting this technical information in a way that would aid its accessibility, interpretability, and applicability by system designers. The present four volumes of the Engineering Data Compendium represent the first implementation of this strategy. This is Volume 1, which contains sections on Visual Acquisition of Information, Auditory Acquisition of Information, and Acquisition of Information by Other Senses.

Boff, Kenneth R.↗

Integrating human factors issues into critical portable detection usage - 121

There are multiple situations where portable detection systems are used to quantify distributed radionuclides. Such applications include holdup measurements in decommissioning activities, other routine usage and safeguards applications. Human factors dominate equipment deployment and operation and have significant impact upon the resulting data collection and its quality. Equipment use includes simultaneous positioning and targeting the object/region being quantified, observation and reporting of incoming data, often in difficult conditions and often while dressed in protective equipment. We examine the human interface with the equipment and other human factors where balance, perception, situational awareness and personnel health level influence the physical control and positioning of the detector. All these aspects impact both the measurement outcome and the Total Measurement Uncertainty (TMU). In this work, we are developing approaches and solutions to: 1. Initiate an inclusive program to assess and evolve human factors aspects of the interface to provide real time feedback tailored to a specific field operator profile. 2. Develop a measurement system human interface on a 'bench top' detection system to allow for both audio and visual I/O for auditory attention and situational (objective and subjective) awareness across varied end user characteristics. 3. Assess and develop an enhanced health assessment plan to identify and monitor pertinent auditory and balance characteristics for operator(s) interface and physical control of the gamma detector. Use the plan to verify personnel ability for effective deployment. We take a multidisciplinary approach to maximize accuracy, efficiency, and safety for the end-user to optimize project and measurement performance. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Waveguides for neurostimulation in the cochlea

Introduction Optical stimulation has been suggested for neural stimulation to improve cochlear implants. Light allows for more spatially selective activation of neuron populations than electrical current, offering more independent frequency bands along the spiral ganglion. These bands are available to encode acoustic information with anticipated better frequency resolution, improving cochlear implant user performance in noisy listening environments, tonal languages, and music perception. Methods Optical cochlear implants (oCIs) can deliver light either directly via small emitters within the cochlea or via waveguides from external optical sources. We investigated three waveguide designs made from OrmoComp ® , a polymer that cures through ultraviolet (UV) radiation. Waveguides were fabricated via injection molding and coated using dip-coating or thermal reflow, or through aspiration of OrmoComp ® into polyimide tubing that served as the cladding of the waveguide. The choice of fabrication technique directly determined the waveguides' total diameter: thermal reflow yielded ≈940 μm, dip-coating produced ≈306 μm, and aspiration resulted in ≈132 μm core diameter waveguides. Given the human cochlea's small size, we focused on analyzing the 306-μm and 132-μm waveguides, evaluating their optical performance (propagation and bending losses) and mechanical properties (bending stiffness and insertion forces). Furthermore, we evaluated some of these designs in in-vivo guinea pigs experiments. Results For the 100-μm core diameter waveguides, the propagation losses were 12.34 ± 1.26, 1.18 ± 0.88, 1.49 ± 0.58, and 3.43 ± 0.68 dB/cm at 534, 1,375, 1,460, and 1,550 nm, respectively. The respective bending losses at a 2 mm radius of curvature were 5.50 ± 1.32, 0.56 ± 0.26, 0.79 ± 0.18, and 0.64 ± 0.23 dB, and at 1 mm 8.54 ± 1.30, 2.05 ± 0.84, 2.11 ± 0.50, and 1.44 ± 0.37 dB. The bending stiffness of a 1 mm segment of the 100-μm-diameter waveguides was 18.9 ± 2.2 N/m. Insertion forces for the 100-μm-diameter waveguides into an acrylic human-size scala tympani model were < 25 mN. For the waveguides with 306 and 940 μm total diameter, the propagation losses ranged between 0.43 and 2.40 dB/cm at 534, 680, 1,375, and 1,550 nm, between 2.19 and 3.78 dB/cm at 450 and 1,460 nm. Bending losses for 360 degrees at 1,375 nm were 5.0, 2.4, and 0.46 for a bending radius of 2.5-, 3-, and 4-mm. Discussion Our study demonstrated that the polymer OrmoComp ® is suitable for fabricating waveguides to transmit near-infrared radiation. In-vivo experiments showed optically evoked auditory responses originating from optical stimulation in the guinea pigs' first cochlear turn while radiation was delivered. Incoming experiments will focus on evaluating long-term performance of these waveguides in guinea pigs and cats. This study will be designed to provide insights into the waveguides' performance and biocompatibility over extended periods, essential for their potential clinical application in future oCIs.

Kim, Matthew↗