Search NASA⌕ Search

SEARCH · Search NASA

Results for “axial pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Deformation of binary and boron-doped Ni 3 Al alloys at high pressures studied with synchrotron x-ray diffraction

In situ x-ray synchrotron diffraction experiments were carried out on nickel-based high-strength superalloys under pressure to understand their deformation mechanism using a diamond anvil cell (DAC). Radial x-ray diffraction determines the room-temperature equations of state and yield strengths of binary Ni 3 Al alloy and 500 ppm boron-doped Ni 3 Al to pressures of 20 and 46 GPa, respectively. Crystallographic preferred orientations observed in these superalloys due to anisotropic stress field in DAC indicate the onset of plastic deformation. Inverse pole figure analysis reveals that the underlying deformation mechanisms change from an octahedral slip to a simultaneous activation of octahedral and cube slips upon doping with boron. The yield-strength values were found to increase with pressure and are comparable to those determined from axial diffraction experiments. The results indicate that the yield strength of Ni 3 Al:B is about 0.5 GPa higher (at pressures below 20 GPa) due to grain boundary strengthening by boron. It is shown that due to high elastic anisotropy of Ni 3 Al alloy, the yield-strength estimations from diffraction experiments strongly depend on the micromechanical model used to convert the measured elastic strains into stresses.

42 ENGINEERING↗

Film condensation with high heat fluxes and scaled experiments using pure steam for reactor containment cooling

Condensation tests were performed using a newly developed test facility for scaling the passive containment cooling system (PCCS) to a small modular reactor (SMR). The PCCS of the SMR plays a pivotal role in ensuring greater safety, reliability, and compactness than what is afforded by traditional reactors. Therefore, a well-designed PCCS is essential to SMRs. However, previous studies and test data were unsuitable for scaling, due to high variation in the test geometry and operating conditions. This study intends to close this research gap by using a novel designed scaled test facility consisting of vertical condensing test sections featuring 1-, 2-, and 4-inch-diameter condensing tubes with annular water cooling, and by applying superheated and saturated steam with different steam mass flow ranges of 5–25 g/s. Further, the primary test data, including axial temperatures, mass flow rates, and pressures, were used in conjunction with a standard data reduction method to estimate critical parameters such as heat fluxes, heat transfer coefficients, and condensation rates. These scaled test data would support improving empirical correlations and validating condensation models to identify scaling distortion for SMR PCCSs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Micropinch formation dynamics in X pinches

High temporal resolution x-ray streak camera studies of micropinch formation in Cu hybrid x pinches reveal key plasma conditions. Analysis of Ne-like Cu lines indicate an average electron temperature of about 200 eV and 4.5×10 28 m -3 electron density. Here, the spectra suggest that the electron temperature jumps to about 1 keV, inferred from the continuum and the postcontinuum line emission that includes Li-like Cu lines. There is no sign of a rapid temperature change or a substantial surge in radiation emission during the 200 ps precontinuum x-ray burst, suggesting that the radiative collapse process does not play a major role in micropinch formation. Two-dimensional extended Magnetohydrodynamic (MHD) simulations, coupled to a collisional-radiative spectral analysis code, suggest the significance of the rapid radial implosion of high-temperature, low-density plasma, the axial outflow, and the dynamic plasma pressure in micropinch formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Efficient Thermal Energy Storage with Radial Flow in Packed Beds

Thermal energy storage (TES) is a way to store excess heat in order to generate power later. These types of systems are valuable in the solar industry, where power production can still occur when sunlight is not available. This not only increases system flexibility, it drives down the cost of electricity. One option to store thermal energy is with a packed bed where the storage media resides in a cylindrical container. Flow from one end of the cylinder to the other deposits or recovers heat (axial flow). While a promising technology in terms of energy storage, it exhibits a high pressure drop that lowers overall system efficiency. This project seeks to flow the heat transfer fluid through the storage media in the radial direction. This system offers the potential to retain reasonable thermal performance while substantially lowering the pressure drop. The overall goal was to assess the performance of radial flow experimentally and numerically. Three main designs were considered in this work. The first system utilized a central pipe and four receiving pipes near the wall. The second system utilized a central pipe and an annulus with holes near the wall. The last approach considered segmenting the bed so only select zones would receive flow in the radial direction. In a high-aspect ratio system, the hole patterns in the piping are important for ensuring even flow into the bed, and a major design effort was testing holes patterns to promote even flow. The four pipe system was shown to be not feasible, as preferential flow paths occur that do not allow even and full heating of the packed bed. The annular system can lead to even flow, but the results show this is better accomplished through larger piping instead of considering variations in the hole pattern along the axial length of the pipe. Segmenting the bed can lead to similar exergetic performance when compared to axial or radial flow. However, the pressure drop in the segmented design is likely too high for practical implementation. A baseline commercial design showed exergetic efficiencies for axial, radial, and radial segments of 81.6%, 82.8%, and 80.2%, respectively. Pressure drop for the axial and radial results were 2.36 psi and 2.45 psi, respectively, with segments being nearly an order of magnitude higher. At these large scales, the aspect ratio of the system is important. From a baseline of 0.64, an aspect ratio of 0.32 for radial flow showed an exergetic efficiency of 86% but a pressure drop of 5.39 psi. All of these results provide new insights into packed bed thermal energy storage with radial flow. Competing effects must be considered when designing a radial system, and results show a radial design can show strong thermal results at the expense of system efficiencies from pressure drop. The COMSOL models used in this analysis are available to the public and other researchers. Public benefits include a potential increase in the efficiency of packed bed thermal energy storage. Higher efficiency in storage promotes green energy technologies while reducing costs.

14 SOLAR ENERGY↗

Full Length Assembly Testing in PELICAN (Final Report)

In support of the development of the U.S. Department of Energy (DOE) Versatile Test Reactor (VTR), a thermal hydraulics test facility was constructed to generate experimental measurement of the pressure drop across a single full-scale assembly containing prototypic axial reflectors, fuel, and plena components. Constructed and operated at Argonne National Laboratory, the Pressure drop Experimental Loop for Investigations of Core Assemblies in Nuclear reactors (PELICAN) facility was designed to achieve hydraulic conditions identical to those anticipated for a full-scale fuel assembly located in the VTR core in the region with the highest flow rate. Using water as surrogate for liquid sodium, the flow loop was operated at elevated temperatures and pressures to match the thermophysical properties of liquid sodium and ensure matching Reynolds and Euler numbers. The measurement objectives for data generated from this test facility was driven primarily by the validation needs for code calculations and simulations of the reference VTR core. These objectives focused on the need to validate pressure drop results across the various segments of the fuel assembly as they relate directly to the pumping power and safety of the reactor. Presented in this report are experimental results and analytical comparisons based on testing of a full-length assembly in PELICAN. Housed within a hexagonal test section extending 3.4 m in length, the tested assembly features a prototypic lower reflector, grid plates, wire-wrapped rod bundle, upper reflector, and exit region. The rod bundle extends over 1.5 m in length and contains 217 individual wire-wrapped rods with dimensions that best reflect the reference VTR design. The as-tested bundle assembly was fabricated using 316 stainless steel 0.25-inch (6.35-mm) diameter rods wrapped with 0.04-inch (1.016-mm) diameter wire at a helical pitch of 10.51 inch (26.6 cm). Details of the method for in-house wire-wrapping, assembly, and installation are provided later in this report. Experimental measurements of pressure drop at 19 positions along the test assembly were recorded for a range of flow conditions, with special attention paid to key locations within the assembly, including component inlet and outlet, transition, and wire-wrapped rod bundle regions. Testing conditions were based on 110°C water with flow rates ranging from 50 to 450 GPM (3 to 27 kg/s) at the inlet of the test assembly generating Reynolds numbers and velocities up to ~8.0×10 4 and ~7.8 m/s, respectively, within the rod bundle region. Non-dimensional values for the friction factor were then calculated based on these experimental measurements and compared against those predicted by various analytical correlations available from open literature. Predictions by the upgraded Cheng and Todreas, Rehme, and Novendstern correlations fell within 4% to those values measured experimentally.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Uncertainties and Limitations of Experimental Thrust and Pressure Gain Measurements in a Rotating Detonation Combustor

Experimentally measuring the pressure gain through the method of equivalent available pressure is prone to many experimental uncertainties. This study performs a detailed uncertainty analysis of the thrust and pressure gain measurements utilizing data from a H2/air operated rotating detonation combustor with an axial air inlet and a 50% exit constriction. The measured (negative) pressure gain values agree with the results in literature for similar inlet-to-exit area ratios. Specific considerations are given to the uncertainty in thrust measurement introduced by the base drag correction on the inner-body. The assumed unity Mach number utilized in the equivalent available pressure methodology is evaluated experimentally with two different methods using time-averaged measurements at the exhaust plane. A definitive demonstration of gain will be challenging given the assessed uncertainties, but recommendations are given to increase the precision of the equivalent available pressure methodology to estimate pressure gain.

33 ADVANCED PROPULSION SYSTEMS↗

Development of a Model Correlating Axial HEPA Filter Performance Between Elevated and Standard Conditions

The ASME AG-1 Code specifies minimum rated airflow based on standard cubic feet per minute (SCFM) for axial high efficiency particulate air (HEPA) filters and actual cubic feet per minute (ACFM) for radial HEPA filters with corresponding maximum pressure drop. A quantitative analysis can be performed to demonstrate the variation in filter efficiency and develop a correlation of performance between axial filters subjected to ACFM and SCFM. This study illustrates the variation in filter efficiency of axial HEPA filters subjected to ACFM and SCFM flow rate conditions at varying atmospheric pressures. It also presents the methods used to calculate correction factors to convert filter efficiency and pressure drop from elevated to standard conditions. The Axial Large Scale Test Stand (ALSTS) in the Institute for Clean Energy Technology (ICET) at Mississippi State University has been utilized to control aerosol concentration, flowrate, atmospheric pressure, relative humidity, and temperature. The filter test matrix consists of axial HEPA filters rated at 1,000 and 1,500 CFM with varying filter pack types. Each filter is subjected to varying pressures of 14.70 psi, 13.55 psi, 12.40 psi, and 11.25 psi, temperatures of 70 deg. F, 110 deg. F, and 150 deg. F, and relative humidities of 50% and 80%, resulting in twenty-four unique testing points. The corresponding SCFM flow rates are computed for each point in order to form a comparison. Evaluation of the effects of designating ACFM or SCFM will be based upon the filter efficiencies of generated Dioctyl Phthalate (DOP) particles at a diameter of 0.3 micrometers. The results show filter efficiency decreasing as atmospheric pressure decreases due to increased filter face velocity. A correlation model is developed to convert filter efficiency and pressure drop at elevated conditions to those of standard pressure, relative humidity, and temperature.

42 ENGINEERING↗

Evaluation of Uncertainties of Pressure Gain Measurements in Rotating Detonation Combustor

Experimentally measuring the pressure gain of a rotating detonation combustor through the method of equivalent available pressure is prone to many experimental uncertainties. A detailed analysis of sources of random and systematic uncertainties in the thrust and pressure gain is performed using data from a hydrogen/air-operated rotating detonation combustor. The combustor had an axial air inlet and a 50% exit constriction. The measured (negative) pressure gain values agree with the results in the literature for similar inlet-to-exit area ratios. The base drag correction on the centerbody was found to be the greatest source of uncertainty for the thrust. While thrust is the predominant source of random uncertainty in the pressure gain calculation, significant systematic errors can be committed due to the assumed exit Mach number. The impact of this assumption becomes more detrimental the closer to positive the measured pressure gain is. By experimentally evaluating the exit Mach number, the random and systematic uncertainty in pressure gain both decreased, indicating that this should be an essential step. A definitive demonstration of gain is challenging, given the assessed uncertainties, and recommendations are provided to increase the precision of the equivalent available pressure methodology.

Engineering↗

Large Eddy Simulation of Externally Induced Ingress about an Axial Seal by Stator Vanes

Turbine inlet temperatures in advanced gas turbines could be as high as 2000 °C. To prevent ingress of this hot gas into the wheelspace between the stator and rotor disks, whose metals can only handle temperatures up to 850 °C, rim seals and sealing flows are used. This study examines the abilities of large eddy simulation (LES) based on the WALE subgrid model and Reynolds-averaged Navier–Stokes (RANS) based on the SST model in predicting ingress in a rotor–stator configuration with vanes but no blades, a configuration with experimental data for validation. Results were obtained for an operating condition, where the ratio of the external Reynolds number to the rotational Reynolds number is 0.538. At this operating condition, both LES and RANS were found to correctly predict the coefficient of pressure, C p , located downstream of the vanes and upstream of the seal, but only LES was able to correctly predict the sealing effectiveness. This shows C p by itself is inadequate in quantifying externally induced ingress. RANS was unable to predict the sealing effectiveness because it significantly under predicted the pressure drop in the hot gas path along the axial direction, especially about the seal region. This affected the pressure difference across the seal in the radial direction, which ultimately drives ingress.

42 ENGINEERING↗

Mjölnir: a miniature triaxial rock deformation apparatus for 4D synchrotron X-ray microtomography

An X-ray transparent experimental triaxial rock deformation apparatus, here named 'Mjölnir', enables investigations of brittle-style rock deformation and failure, as well as coupled thermal, chemical and mechanical processes relevant to a range of Earth subsurface environments. Designed to operate with cylindrical samples up to 3.2 mm outside-diameter and up to 10 mm length, Mjölnir can attain up to 50 MPa confining pressure and in excess of 600 MPa axial load. The addition of heaters extends the experimental range to temperatures up to 140°C. Deployment of Mjolnir on synchrotron beamlines indicates that full 3D datasets may be acquired in a few seconds to a few minutes, meaning full 4D investigations of deformation processes can be undertaken. Mjölnir is constructed from readily available materials and components and complete technical drawings are included in the supporting information.

47 OTHER INSTRUMENTATION↗

Multi-Objective Optimization of a Bi-Metal High-Temperature Recuperator for Application in Concentrating Solar Power

Supercritical CO 2 closed Brayton cycles are a major candidate for future power cycle designs in concentrating solar power applications, with high-temperature recuperators playing an essential role in realizing their high thermal efficiency. Here, printed circuit heat exchangers (PCHEs) are often chosen for this role due to their thermal-hydraulic and mechanical performance at high temperatures and pressures, all while remaining compact. However, PCHEs can be costly because of the high-performance materials demanded in these applications, and the heat exchanger internal geometry is restricted by their manufacturing process. Additively manufactured heat exchangers can address both of these shortcomings. This work proposes a modular bi-metal high-temperature recuperator with integrated headers to be produced with additive manufacturing. Beginning with existing PCHE channel geometries, a 1D heat exchanger model is developed. Then, multi-objective optimization is used to maximize the heat transfer effectiveness of a lab-scale device while limiting its size. Two distinct channel geometries emerge from the optimization. Optimal designs achieve up to 88% effectiveness with negligible pressure drop. Deterioration of effectiveness due to axial conduction of heat in the heat exchanger walls is found to be a notable problem for lab-scale PCHEs, and the optimal designs obtained here minimize its detrimental effects. A sensitivity analysis reveals that the effectiveness of the recuperator is much less sensitive to variation in mass flowrate in off-design operation when axial conduction is significant, while increasing the length of the device easily increases effectiveness.

14 SOLAR ENERGY↗

Blade and airfoil damping configurations

The present embodiments set forth a blade including an airfoil, the airfoil including a tip cap, a pressure sidewall and a suction sidewall extending axially between corresponding leading and trailing edges and radially between the base and the tip cap. The blade, including the airfoil and base, being formed in at least two airfoil parts, each of the two airfoil parts including contacting edges engaging each other respective contacting edges, the contacting edges defining a joint for preloading each of the at least two parts with each other and with the base. The at least two airfoil parts forming the airfoil being retained to each other by an interference fit at the joint. The interference fit providing frictional damping of vibrations in the blade during blade operation.

Hart, Andrew Clifford↗

Mode transitions and spoke structures in E × B Penning discharge

Two-dimensional particle-in-cell simulations in the (radial-azimuthal) plane perpendicular to the axial direction of a cylindrical $E$ x $B$ Penning discharge are presented. The low-pressure discharge is self-consistently supported by plasma ionization from the electron beam injected axially, along the direction of the external magnetic field. It is shown that with the increasing strength of the external magnetic field, the discharge undergoes a sequence of transitions between several azimuthal modes. Azimuthal m > 1 spiral arm structures are excited at low magnetic field values as plasma confinement improves and the radial density profile becomes peaked. With a larger field, spiral arms with m > 1 are replaced by the m = 1 spoke mode, most clearly seen in plasma density. A transition from spiral arms to the spoke regime occurs when the plasma potential in the center changes from weakly positive (or zero) to negative. Further increase in the magnetic field results in a well-developed m = 1 spoke mode with additional small-scale higher-frequency m > 1 structures inside and around the spoke. It is shown that while ionization and collisions affect some characteristics of the observed fluctuations, the basic features of the spoke and m > 1 spiral structure remained similar without ionization. The role of energy conservation in small-scale high-frequency modes and spoke dynamics is discussed. It is demonstrated that in regimes with the m = 1 spoke mode, additional m = 4 harmonics of the ion and electron fluxes to the wall appear due to the square boundary. The frequency of the m = 1 mode is weakly affected by the geometry of the boundary.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prediction of strain, inter-layer interaction and critical current in CORC ® wires under axial strain by T-A modeling

Superconducting conductors on round core (CORC ® ) cables and wires can meet the needs of large high-field magnets, such as particle accelerators and compact nuclear fusion machines, due to their simple cabling process, high current-carrying capacity and reliable operation under high mechanical stresses. Many high-field magnets require CORC ® cables to carry a current of thousands of amperes in a background magnetic field exceeding 20 T. As a result, the large electromagnetic forces will deform the cable in the axial direction due to hoop stress and in the transverse direction by compressive stress. Therefore, it is essential to determine the irreversible deformation limit of the CORC ® cable under axial tensile load and optimize the cabling parameters to potentially extend this limit. Analytical and numerical methods are developed to assess the performance degradation of CORC ® wires under axial tensile load. The strain level, interlayer contact pressure and friction and their impact on the critical current are calculated by combining the mechanical response and the T-A method. Analyzing the results shows that the winding angle of the tape and the Poisson’s ratio of the inner core are key factors affecting the irreversible tensile strain limit of CORC ® wires. The smaller the winding angle and the higher the Poisson’s ratio of the inner core, the higher the irreversible tensile strain limit. For multi-layer CORC ® wires, the initial contact pressure caused by the cabling process must also be considered. The inter-layer interaction is coupled with the tape strain of each layer. The results of this research can serve as a basis for optimizing and designing CORC ® wires with extended irreversible strain limits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Report Summarizing Progress in Digital Image Correlation Analysis of Burst Phenomenon

This report is an update on the progress made towards utilizing in-situ methods to observe and quantify Zry-4 deformation behavior during burst testing. A heavily modified burst test was developed that allows both digital image correlation and infrared thermography to be utilized during testing to quantify strain and axial thermal gradient data during burst. A variety of tests ranging from 6.2-15.9 MPa internal pressure and utilizing both constant and transient pressure conditions were conducted and presently reported on. The test modifications, which are detailed extensively in a previous report, are effectively found to have no discernible impact on burst temperatures when compared to historical Zircaloy burst data. To support future modeling studies, the IR thermography data was used to approximate the thermal gradient down the axial length at burst for all the claddings. Then, DIC is first correlated to thermocouple temperature for a 10.3 MPa Transient pressure test, and then DIC correlated to IR thermal gradient data down the axial length of a 8.2 MPa Transient pressure test at several points.

36 MATERIALS SCIENCE↗

Voltage and cathode emission mechanisms of a magnetized, constricted, orbiting plasma in helium 6.7–850 Pa

Abstract We present a semiquantitative description of several important properties of a magnetized cold-cathode plasma in helium over a wide pressure range 6.7–850 Pa. We focus on the ‘constricted orbiting’ mode where the plasma attaches to the cathode as a moving ‘dot’ and the voltage and rate of cathode erosion are both unusually low. We propose that the low plasma voltage and observed motion of the plasma adjacent to the cathode can be attributed to field emission as the source of electrons from the cathode, a process that is aided by the charging of an oxide film by ions. We find that the observed dependence of plasma voltage on pressure is consistent with the assumption that the axial electric field must increase in regions of strong crossed magnetic field to maintain current continuity.

Physics↗

Centrifugal-mirror confinement with strong azimuthal magnetic field

One practical challenge for the centrifugal-mirror confinement concept is the large radial voltage necessary to drive supersonic azimuthal rotation. In principle, the addition of a strong azimuthal field could reduce the required voltage, since the simple azimuthal E x B drift would be replaced by more rapid azimuthal trapped-particle precession. Also, if the mirror ratio is large enough, newly ionized ions are accelerated to the necessary parallel velocities in their first bounce orbit, both confining and significantly heating them. Unfortunately, MHD analysis shows that the centrifugal-force-confining plasma current is purely azimuthal. This implies that only the axial magnetic field contributes to the confining magnetic pressure, severely limiting the usefulness of the azimuthal magnetic field in a beta-limited plasma scenario.

Grad-Shafranov↗