Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Structural, Electrical and Optical Properties of Gallium Doped Zinc Oxide Thin Films Prepared by Electron Beam Evaporation Technique

High quality gallium doped zinc oxide (GZO) films are prepared by electron beam evaporation technique. The effect of substrate temperature on structural, electrical and optical properties was studied in detail. The prepared films are polycrystalline in nature with c-axis perpendicular to the substrate. The resistivity of the film decreases and the optical transparency increases as the substrate temperature increases from room temperature to 150 deg. C. The film produce the optical band gap of 3.47 eV.

36 MATERIALS SCIENCE↗

Electrical characterization of ensemble of GaN nanowires grown by the molecular beam epitaxy technique

High quality Schottky contacts are formed on GaN nanowires (NWs) structures grown by the molecular beam epitaxy technique on Si(111) substrate. The current-voltage characteristics show the rectification ratio of about 10{sup 3} and the leakage current of about 10{sup −4} A/cm{sup 2} at room temperature. From the capacitance-voltage measurements the free carrier concentration in GaN NWs is determined as about 10{sup 16} cm{sup −3}. Two deep levels (H200 and E280) are found in the structures containing GaN NWs. H200 is attributed to an extended defect located at the interface between the substrate and SiN{sub x} or near the sidewalls at the bottom of the NWs whereas E280 is tentatively assigned to a gallium-vacancy- or nitrogen interstitials-related defect.

36 MATERIALS SCIENCE↗

TH-C-17A-07: Visualizing and Quantifying Radiation Therapy in Real-Time Using a Novel Beam Imaging Technique

Purpose: Radiation therapy uses invisible high energy X-rays to treat an invisible tumor. Proper positioning of the treatment beam relative to the patient's anatomy during dose delivery is critically important to the success of treatment. We develop and characterize a novel radiation therapy beam visualization technique for real-time monitoring of patient treatment. Methods: Custom made flexible scintillator sheets were fabricated from gadolinium oxysulfide (GOS) particles that had been doped with terbium within a silicone elastomer matrix. Sheets of several thicknesses ranging from 0.3 to 1mm were prepared and tested. Sheets were exposed to megavoltage X-ray and electron beams from a Varian linac and the resulting optical signal was collected by multiple CMOS cameras placed in the treatment room. Real-time images were collected for different beam energies and dose rates. Signal intensity and SNR were calculated by processing the acquired images. Results: All signals were detectable in the presence of full room lighting and at an integration time of 45ms. Average signal intensity and SNR increased with both sheet thickness and dose rate and decreased with beam energy and incident light. For a given sheet thickness and beam energy the correlation between dose rate and signal intensity was highly linear. Increased sheet thickness or dose rate results in a linear increase in the detected signal. All results are consistent with analytical approximations. Conclusion: The technique offers a means of accurately visualizing a radiation therapy beam shape and fluence in real time. The effects of salient parameters have been characterized and will enable further optimization of the technique as it is implemented into the clinical workflow. The project described was supported by the National Center for Advancing Translational Sciences of the National Institutes of Health through UL1 TR001085.

60 APPLIED LIFE SCIENCES↗

Solar Wind Charge Exchange Studies Of Highly Charged Ions On Atomic Hydrogen

Accurate studies of low-energy charge exchange (CX) are critical to understanding underlying soft X-ray radiation processes in the interaction of highly charged ions from the solar wind with the neutral atoms and molecules in the heliosphere, cometary comas, planetary atmospheres, interstellar winds, etc.. Particularly important are the CX cross sections for bare, H-like, and He-like ions of C, N, O and Ne, which are the dominant charge states for these heavier elements in the solar wind. Absolute total cross sections for single electron capture by H-like ions of C, N, O and fully-stripped O ions from atomic hydrogen have been measured in an expanded range of relative collision energies (5 eV/u-20 keV/u) and compared to previous H-oven measurements. The present measurements are performed using a merged-beams technique with intense highly charged ion beams extracted from a 14.5 GHz ECR ion source installed on a high voltage platform at the Oak Ridge National Laboratory. For the collision energy range of 0.3 keV/u-3.3 keV/u, which corresponds to typical ion velocities in the solar wind, the new measurements are in good agreement with previous H-oven measurements. The experimental results are discussed in detail and compared with theoretical calculations where available.

74 ATOMIC AND MOLECULAR PHYSICS↗

Preparation and characterization of indium zinc oxide thin films by electron beam evaporation technique

In this work, the preparation of In{sub 2}O{sub 3}-ZnO thin films by electron beam evaporation technique on glass substrates is reported. Optical and electrical properties of these films were investigated. The effect of dopant amount and annealing temperature on the optical and electrical properties of In{sub 2}O{sub 3}-ZnO thin films was also studied. Different amount of ZnO was used as dopant and the films were annealed at different temperature. The results showed that the most crystalline, transparent and uniform films with lowest resistivity were obtained using 25 wt% of ZnO annealed at 500 {sup o}C.

36 MATERIALS SCIENCE↗

Effect of discharge current and deposition temperature on roughness and density of NbC films fabricated by ion beam sputtering technique

NbC films were prepared using Ion beam sputtering system at various discharges current from 0.4 amps to 1.2 amps at room temperature. Effect of temperature on NbC films were also studied by depositing NbC films at various temperatures from room temperature to 200,300,400 and 600°C. X-ray reflectivity (XRR) study shows that surface roughness of the film decreases with decrease in discharge current. The optimum lowest roughness 3.2Å having density 92% of bulk was achieved at discharge current 0.6 amps at 3.0 cm{sup 3}/min Ar gas flow. X-ray study also shows that film roughness decreases with increase in temperature of the film and after a certain temperature it increases with increase in temperature. The lowest surface roughness 2.1Å was achieved at 300°C with density 83% of bulk NbC at constant discharge current 0.6 amps.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TH-EF-207A-04: A Dynamic Contrast Enhanced Cone Beam CT Technique for Evaluation of Renal Functions

Purpose: To develop a simple but robust method for the early detection and evaluation of renal functions using dynamic contrast enhanced cone beam CT technique. Methods: Experiments were performed on an integrated imaging and radiation research platform developed by our lab. Animals (n=3) were anesthetized with 20uL Ketamine/Xylazine cocktail, and then received 200uL injection of iodinated contrast agent Iopamidol via tail vein. Cone beam CT was acquired following contrast injection once per minute and up to 25 minutes. The cone beam CT was reconstructed with a dimension of 300×300×800 voxels of 130×130×130um voxel resolution. The middle kidney slices in the transvers and coronal planes were selected for image analysis. A double exponential function was used to fit the contrast enhanced signal intensity versus the time after contrast injection. Both pixel-based and region of interest (ROI)-based curve fitting were performed. Four parameters obtained from the curve fitting, namely the amplitude and flow constant for both contrast wash in and wash out phases, were investigated for further analysis. Results: Robust curve fitting was demonstrated for both pixel based (with R{sup 2}>0.8 for >85% pixels within the kidney contour) and ROI based (R{sup 2}>0.9 for all regions) analysis. Three different functional regions: renal pelvis, medulla and cortex, were clearly differentiated in the functional parameter map in the pixel based analysis. ROI based analysis showed the half-life T1/2 for contrast wash in and wash out phases were 0.98±0.15 and 17.04±7.16, 0.63±0.07 and 17.88±4.51, and 1.48±0.40 and 10.79±3.88 minutes for the renal pelvis, medulla and cortex, respectively. Conclusion: A robust method based on dynamic contrast enhanced cone beam CT and double exponential curve fitting has been developed to analyze the renal functions for different functional regions. Future study will be performed to investigate the sensitivity of this technique in the detection of radiation induced kidney dysfunction.

60 APPLIED LIFE SCIENCES↗

Growth of cluster assembled ZnO film by nanocluster beam deposition technique

ZnO is considered as one of the most promising material for optoelectronic devices. The present work emphasizes production of cluster assembled ZnO films by a UHV nanocluster beam deposition technique where the nanoclusters were produced in a laser vaporization cluster source. The microstructural and the optical properties of the ZnO nanocluster film deposited were investigated. As the wet chemical processes are not compatible with current solid state methods of device fabrication, therefore alternative UHV technique described in the paper is the need of the hour.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparison of external beam treatment techniques for T1-2, N0, M0 glottic cancers

The purpose of this study was to compare 4 different external beam radiation therapy treatment techniques for the treatment of T1-2, N0, M0 glottic cancers: traditional lateral beams with wedges (3D), 5-field intensity-modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT), and proton therapy. Treatment plans in each technique were created for 10 patients using consistent planning parameters. The photon treatment plans were optimized using Philips Pinnacle{sub 3} v.9 and the IMRT and VMAT plans used the Direct Machine Parameter Optimization algorithm. The proton treatment plans were optimized using Varian Eclipse Proton v.8.9. The prescription used for each plan was 63 Gy in 28 fractions. The contours for spinal cord, right carotid artery, left carotid artery, and normal tissue were created with respect to the patient's bony anatomy so that proper comparisons of doses could be made with respect to volume. An example of the different isodose distributions will be shown. The data collection for comparison purposes includes: clinical treatment volume coverage, dose to spinal cord, dose to carotid arteries, and dose to normal tissue. Data comparisons will be displayed graphically showing the maximum, mean, median, and ranges of doses.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optical beam forming techniques for phased array antennas

Conventional phased array antennas using waveguide or coax for signal distribution are impractical for large scale implementation on satellites or spacecraft because they exhibit prohibitively large system size, heavy weight, high attenuation loss, limited bandwidth, sensitivity to electromagnetic interference (EMI) temperature drifts and phase instability. However, optical beam forming systems are smaller, lighter, and more flexible. Three optical beam forming techniques are identified as applicable to large spaceborne phased array antennas. They are (1) the optical fiber replacement of conventional RF phased array distribution and control components, (2) spatial beam forming, and (3) optical beam splitting with integrated quasi-optical components. The optical fiber replacement and the spatial beam forming approaches were pursued by many organizations. Two new optical beam forming architectures are presented. Both architectures involve monolithic integration of the antenna radiating elements with quasi-optical grid detector arrays. The advantages of the grid detector array in the optical process are the higher power handling capability and the dynamic range. One architecture involves a modified version of the original spatial beam forming approach. The basic difference is the spatial light modulator (SLM) device for controlling the aperture field distribution. The original liquid crystal light valve SLM is replaced by an optical shuffling SLM, which was demonstrated for the 'smart pixel' technology. The advantages are the capability of generating the agile beams of a phased array antenna and to provide simultaneous transmit and receive functions. The second architecture considered is the optical beam splitting approach. This architecture involves an alternative amplitude control for each antenna element with an optical beam power divider comprised of mirrors and beam splitters. It also implements the quasi-optical grid phase shifter for phase control and grid amplifier for RF power. The advantages are no SLM is required for this approach, and the complete antenna system is capable of full monolithic integration.

Wu, Te-Kao↗

SU-E-T-621: Analysis of Robustness of Proton Pencil Beam Scanning Technique for Delivery of Craniospinal Irradiation

Purpose: To investigate the robustness and safety of craniospinal irradiation (CSI) planned with a proton pencil beam scanning (PBS) technique which overcomes the complexity of the planning associated with feathering match lines. Methods: Six CSI patients were planned with gradient-dose matching using PBS technique. Uniform dose coverage to the entire target volumes was achieved with averaged junction lengths of 6.9±0.3 cm. Robustness of the plans was evaluated by shifting the isocenter of each treatment field by ±3 mm in longitudinal direction and compared with the original non-shifted plan with metrics of conformity number (CN) and homogeneity index (HI). An anthropomorphic phantom study using film measurements was also carried out on a plan with 5 cm junction length. Results: For a given junction length, the dose errors were directly proportional to the setup errors. Setup errors of 3 mm from each field caused on average 3.5% lower CN and 2.1% higher HI. Minimal D95% to PTV and D98% to CTV were reduced by 2.2%±1.5% and 2.8%±1.7% respectively. A drop of maximal 6.8%±5.5% on the minimal dose to the cribriform plate was also observed. When the junction length was 5cm or longer, these 3mm setup errors from each field resulted in up to 12% dose errors. Consistent results were reached between film measurements and planned dose profiles in the junction area. Due to near-zero exit doses beyond the target volume, sparing of anterior organs such as heart, liver, lung and kidney were observed. Conclusions: Longitudinal setup errors directly reduce the dosimetric accuracy of the CSI treatment with matched proton fields. The reported technique creates a slow dose gradient in the junction area, which makes the treatment more robust and safe to longitudinal setup errors compared to conventional feathering methods.

60 APPLIED LIFE SCIENCES↗

The detection of electron-beam-induced current in junctionless semiconductor

The scanning electron microscope is a versatile tool and its electron beam techniques have been widely used in semiconductor material and device characterizations. One of these electron beam techniques is the electron-beam-induced current (EBIC) technique. One of the limitations of the conventional EBIC technique is that it requires charge collecting junctions which may not be readily available in junctionless samples such as bare substrates unless some special sample preparation procedure such as the fabrication of a diffused junction is done on the junctionless sample. In this paper, the technique of detecting EBIC current in junctionless samples with the use of a two-point probe is presented. It is found that the EBIC current is independent from its physical parameter when the sample thickness is greater than 4L; the width to the right of probe 2 and the width to the left of probe 1 are greater than 2L and 8L, respectively. The parameters affecting this technique of detecting the EBIC current such as the depth of the generation volume, probe spacing, and the applied bias are also discussed in this paper. A commercially available two-dimensional device simulator was used to verify this technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental investigation of beam-ion losses induced by magnetic perturbations using the light ion beam probe technique in the ASDEX Upgrade tokamak

The impact of externally applied magnetic perturbations (MPs) on fast-ion losses has been investigated by means of the light ion beam probe (LIBP) technique in the ASDEX Upgrade tokamak. The LIBP technique allows to experimentally infer the fast-ion orbit displacement induced by MPs via first-orbit losses using scintillator based fast-ion loss detector (FILD) measurements. The fast-ion orbit displacement against different applied MP spectra has been studied. These shots were conducted in ELM mitigated H-mode plasmas. A rigid rotation of the MP coils was applied with a frequency of 1 Hz, with an n = 2 configuration and changing the differential phase between the upper and lower set of coils (ΔΦ ul ) on a shot-to-shot basis. Beam sources Q7 (tangential) and Q8 (radial) were used to probe different fast-ion orbits with FILD1. The measured fast-ion orbit displacement ranges from 3 to 20 mm approximately, and no qualitative difference is observed between ions from beam sources Q7 and Q8. The minimum is found for a ΔΦ ul ~ 50°, which is shifted with respect to the minimum of the plasma boundary displacement, found at ΔΦ ul ~ 0°. A first attempt to validate the orbit following code ASCOT—including the plasma response calculated with the MARS-F code—against these experimental measurements is performed. Finally, while the dependence of the first-orbit fast-ion displacement with ΔΦ ul does not match the experimental measurements, these simulations do capture other features such as the order of magnitude of the orbit displacement and the importance of the toroidal spectrum of the applied perturbation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗