Fort Devens: Cold Climate Market-Rate Townhomes Targeting HERS Index of 40, Harvard, Massachusetts (Fact Sheet)

Achieving aggressive energy efficiency targets requires tight coordination and clear communication among owners, designers, builders, and subcontractors. For this townhome project, MassDevelopment, the quasi-governmental agency owner, selected Metric Development of Boston, teaming with the U.S. Department of Energy (DOE) Consortium for Advanced Residential Buildings (CARB) and Cambridge Seven Architects, to build very high performing market-rate homes. Fort Devens is part of a decommissioned army base in working-class Harvard, Massachusetts, approximately one hour northwest of Boston. The team proposed 12 net zero energy-ready townhomes, meaning that the application of renewable energy systems would result in annual net zero energy use in the homes. The homes were also designed to achieve a Home Energy Rating System (HERS) Index Score of 41 before adding renewables. For this project, CARB drew on its experience working with Rural Development Inc. on a series of affordable townhomes in northern Massachusetts. The team carefully planned the site to maximize solar access, daylighting, and efficient building forms. The basic strategy was to design a very efficient thermal enclosure while minimizing incremental cost increases compared with standard construction. Using BEopt modeling software, the team established the requirements of the enclosure and investigated multiple assembly options. They settled on double-wall construction with dense-pack cellulose fill. High performance vinyl windows (U-0.24, solar heat gain coefficient [SHGC]-0.22), a vented R-59 attic, and exceptional air sealing completed the package.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Evaluation of a New Construction Pilot Community: Fresno, California

A new construction pilot community was constructed by builder-partner Wathen-Castanos Hybrid Homes (WCHH) based on a single occupied test house that was designed to achieve greater than 30% energy savings with respect to the House Simulation Protocols (Hendron, Robert; Engebrecht, Cheryn (2010). Building America House Simulation Protocols. Golden, CO: National Renewable Energy Laboratory). Builders face several key problems when implementing a whole-house systems integrated measures package (SIMP) from a single test house into multiple houses. Although a technical solution already may have been evaluated and validated in an individual test house, the potential exists for constructability failures at the community scale. This report addresses factors of implementation and scalability at the community scale and proposes methodologies by which community-scale energy evaluations can be performed based on results at the occupied test house level. Research focused on the builder and trade implementation of a SIMP and the actual utility usage in the houses at the community scale of production. Five occupants participated in this community-scale research by providing utility bills and information on occupancy and miscellaneous gas and electric appliance use for their houses. IBACOS used these utility data and background information to analyze the actual energy performance of the houses. Verification with measured data is an important component in predictive energy modeling. The actual utility bill readings were compared to projected energy consumption using BEopt with actual weather and thermostat set points for normalization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt(tm) whole-house building simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Pump Water Heating Modeling in EnergyPlus [Slides]

This presentation summarizes NREL's development of a HPWH model for use in hourly building energy simulation programs, such as BEopt. This presentation was given at the Building America Stakeholder meeting on March 1, 2012, in Austin, Texas.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Illinois Home Performance with ENERGY STAR® Measure Packages

Through the Chicagoland Single Family Housing Characterization and Retrofit Prioritization report, the Partnership for Advanced Residential Retrofit research team characterized 15 housing types in the Chicagoland region based on assessor data, utility billing history, and available data from prior energy efficiency programs. Within these 15 groups, a subset showed the greatest opportunity for energy savings based on BEopt Version 1.1 modeling of potential energy efficiency package options and the percent of the housing stock represented by each group. In this project, collected field data from a whole-home program in Illinois are utilized to compare marketplace-installed measures to the energy saving optimal packages previously developed for the 15 housing types. Housing type, conditions, energy efficiency measures installed, and retrofit cost information were collected from 19 homes that participated in the Illinois Home Performance with ENERGY STAR program in 2012, representing eight of the characterized housing groups. Two were selected for further case study analysis to provide an illustration of the differences between optimal and actually installed measures. Taken together, these homes are representative of 34.8% of the Chicagoland residential building stock. In one instance, actual installed measures closely matched optimal recommended measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermostatic Radiator Valve Evaluation

A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market. In this project, the ARIES team sought to better understand the current usage of TRVs by key market players in steam and hot water heating and to conduct limited experiments on the effectiveness of new and old TRVs as a means of controlling space temperatures and reducing heating fuel consumption. The project included a survey of industry professionals, a field experiment comparing old and new TRVs, and cost-benefit modeling analysis using BEopt™ (Building Energy Optimization software).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Evaluation of a New Construction Pilot Community: Fresno, California

A new construction pilot community was constructed by builder-partner Wathen-Castanos Hybrid Homes based on a single occupied test house that was designed to achieve greater than 30% energy savings with respect to the Building America House Simulation Protocols developed by NREL. Builders face several key problems when implementing a whole-house systems integrated measures package from a single test house into multiple houses. This report addresses factors of implementation and scalability at the community scale and proposes methodologies by which community-scale energy evaluations can be performed based on results at the occupied test house level. Research focused on the builder and trade implementation of a measures package and the actual utility usage in the houses at the community scale of production. Five occupants participated in this research by providing utility bills and information on occupancy and miscellaneous gas and electric appliance use for their houses. IBACOS used these utility data and background information to analyze the actual energy performance of the houses. The actual utility bill readings were compared to projected energy consumption using BEopt with actual weather and thermostat set points for normalization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of U.S. climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt™ whole-house building simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Replicable Solutions for High-Performance Homes in the Southeast

Southface Energy Institute (Southface) partnered with owners and/or builders with various market constraints and ultimate goals for three projects in different climate zones: Savannah, GA (CZ 2), Clemson, SC (CZ 3), and LaFayette, GA (CZ 4). This report documents the design process, computational energy modeling, construction, envelope performance metrics, long-term monitoring results, and successes and failures of the design and execution of these high performance homes. The three bedroom/two bathroom test home in Savannah Gardens on an elevated slab foundation has a semi-conditioned, encapsulated attic. A neighboring home built to EarthCraft specifications was also monitored as a control for exterior foam insulation and a heat pump water heater (HPWH). For the JMC Patrick Square, a single-story project in Clemson, the small-scale production builder wanted to increase their level of energy efficiency beyond their current green building practices, including bringing ducts into conditioned space. Through a combination of upgrade measures the team met this goal and achieved many Zero Energy Ready Home requirements. LaFayette Housing Authority undertook a development of 30 affordable rental housing units in 15 duplexes in LaFayette, GA. Because they would be long-term owners, their priorities were low utility bills for the residents and durable, maintainable buildings. The team employed BEopt to optimize buildling envelope and systems choices, including 2x6 advanced framed walls, insulated slab, and heat pump water heater in a utility closet which was ducted to/from an encapsulated attic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aerosol Envelope Sealing of Existing Residences

This report explores the best methods for aerosol envelope sealing of unoccupied, existing residences and documents typical leakage reductions. The project consisted of three distinct efforts: (1) scaled field demonstrations of the sealing process, tracking from setup to sealing and cleanup, (2) laboratory testing of new sealants that dry clear, making them more appropriate for retrofit applications, and (3) BEopt™ (Building Energy Optimization Tool) modeling of the energy implications of the measured reductions in leakage. Overall, aerosol sealing performance in existing homes was effective, with an average leakage reduction of 47% across all 34 sites. Conventional approaches typically only produce leakage reductions of 25%–30%. The aerosol sealing technology could provide a process for existing homes and multifamily units to gain the benefits of a well-sealed home at a reasonable cost with minimal disruption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermostatic Radiator Valve Evaluation and Demonstration

A large stock of multifamily buildings in the Northeast and Midwest uses hot water or steam for space heating. Typically, residents do not pay for heat directly (i.e., heating fuel serves a central plant and use is not submetered). Losses from these systems are typically high, and a significant number of apartments are overheated much of the time. This is often evidenced by open windows on winter days. Controls and distribution are often faulty, and improving them can be more cost effective than replacing boilers. Thermostatic radiator valves (TRVs), which have been in use for many decades, are one potential strategy to combat this problem. They are commonly used in Europe and in other markets such as commercial buildings, but have not been widely accepted by the residential retrofit market in the northeastern United States. Anecdotal evidence suggests that heating systems engineers and contractors have a variety of opinions about their effectiveness, illustrating a lack of consensus on this potentially important energy efficiency measure. A review of the limited available literature revealed that, in one study, heating fuel savings as high as 15% was achieved through TRV retrofits. In this project, the U.S. Department of Energy Building America team, Advanced Residential Integrated Energy Solutions, sought to better understand the current usage of TRVs by key market players in steam and hot water heating and to conduct limited experiments on the effectiveness of new and old TRVs as a means of controlling space temperatures and reducing heating fuel consumption. The project included a survey of industry professionals, a field experiment comparing old and new TRVs, and cost-benefit modeling analysis using BEopt (Building Energy Optimization software). Radiator and apartment space temperature data were collected and analyzed for two similar apartment units in a building that underwent a one-pipe steam TRV retrofit. Space temperature comparisons were made across the pre- and post-TRV installation heating periods and between rooms equipped with old or new TRVs in an attempt to show the comparative effectiveness of each vintage of TRV. Analyses of the heating fuel utility bills before and after the building-wide TRV installation were conducted to quantify potential savings. The results of the field experiment and utility bill analysis did not show energy savings at either the unit or the building-wide level. The results provided inconclusive answers to the original study questions but provided valuable insight into common steam system imbalance and resident behavior issues that are critical to address in conjunction with TRV retrofits. Specific issues identified included steam distribution imbalance, possible TRV sensor location issues, a persistent window-opening habit, and a failure to optimize the boiler control set points as part of the TRV retrofit. The lack of heating fuel savings underscored the need to include whole steam system commissioning alongside or as a prerequisite to TRVs. Failed air vents and uneven steam main venting are critical to address either in conjunction with or before a TRV installation. Monitoring existing space temperatures before a retrofit strategy is chosen would allow the consultant and building owner to better assess the potential benefits of a whole-building TRV retrofit, selective installation of TRVs in some units, or simply balancing the steam distribution venting. Further gaps in the understanding of underlying processes that allow TRVs to function effectively were also identified and are presented as opportunities for future research.

Array↗

Phased Retrofits in Existing Homes in Florida Phase I: Shallow and Deep Retrofits

The U.S. Department of Energy's Building America research team Building America Partnership for Improved Residential Construction is collaborating with Florida Power & Light (FPL) to conduct a phased residential energy-efficiency retrofit program. This research seeks to establish impacts on annual energy and peak energy reductions from the technologies applied at two levels of retrofit-shallow and deep-with savings levels that approach the Building America program goal of reducing whole-house energy use by 40%. Home 7 - Merritt Island, FL 32952 Home 39 - Palm Bay, FL 32907 - BEOpt 2.1.0.2

Array↗

National Renewable Energy Laboratory/Habitat for Humanity Zero Energy Home: A Cold Climate Case Study for Affordable Zero Energy Homes

The design of this 1,280-square-foot, three-bedroom Habitat for Humanity of Metro Denver zero energy home carefully combines envelope efficiency, efficient equipment, appliances and lighting, and passive and active solar features to reach the zero energy goal. The home was designed with an early version (July 22, 2004) of the BEOpt building optimization software; DOE2 and TRNSYS were used to perform additional analysis. This engineering approach was tempered by regular discussions with Habitat construction staff and volunteers. These discussions weighed the applicability of the optimized solutions to the special needs and economics of a Habitat house, moving the design toward simple, easily maintained mechanical systems and volunteer-friendly construction techniques. A data acquisition system was installed in the completed home to monitor its performance. The home's energy performance was monitored for 10 years. A comprehensive report on the home was done after the first 2 years of monitoring and a follow-up ACEEE paper on the project including 10 years of performance data was presented in 2016.

Affordable Housing↗

Achieving Challenge Home in Affordable Housing in the Hot - Humid Climate

The Building America Partnership for Improved Residential Construction (BA-PIRC), one of the Building America research team leads, has partnered with two builders as they work through the Challenge Home certification process in one test home each. The builder partners participating in this cost-shared research are Southeast Volusia County Habitat for Humanity near Daytona, Florida and Manatee County Habitat for Humanity near Tampa, Florida. Both are affiliates of Habitat for Humanity International, a non-profit affordable housing organization. This research serves to identify viable technical pathways to meeting the CH criteria for other builders in the region. A further objective of this research is to identify gaps and barriers in the marketplace related to product availability, labor force capability, code issues, cost effectiveness, and business case issues that hinder or prevent broader adoption on a production scale. The builder partners participating in this cost-shared research are Southeast Volusia County Habitat for Humanity (SEVHFH) near Daytona, Florida and Manatee County Habitat for Humanity (MCHFH) near Tampa, Florida. Both are affiliates of Habitat for Humanity International (HFHI), a nonprofit affordable housing organization. Manatee Co Habitat for Humanity Challenge home - Ellenton, FL 34222 S. Sarasota Challenge Home - Sarasota, FL Southeast Volusia co Habitat for Humanity's Challenge Home - Edgewater, FL 32141 Several iterations of home, Challenge Home as built, Challenge Home without solar, and Challenge Home configured to just meet Florida Code. All houses redone in BEOpt 2.1.0.2

affordable housing↗

Heat Pump Water Heater Modeling in EnergyPlus (Presentation)

This presentation summarizes NREL's development of a HPWH model for use in hourly building energy simulation programs, such as BEopt; this presentation was given at the Building America Stakeholder meeting on March 1, 2012, in Austin, Texas.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Pump Water Heater Modeling in EnergyPlus (Slides)

This presentation summarizes NREL's development of a HPWH model for use in hourly building energy simulation programs, such as BEopt; this presentation was given at the Building America Stakeholder meeting on March 1, 2012, in Austin, Texas.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Low-Cost Evaluation of Energy Savings at the Community Scale, Fresno, California (Fact Sheet)

A new construction pilot community was constructed by builder-partner Wathen-Castanos Hybrid Homes (WCHH) based on a single occupied test house that was designed to achieve greater than 30% energy savings with respect to the House Simulation Protocols (Hendron, Robert; Engebrecht, Cheryn (2010). Building America House Simulation Protocols. Golden, CO: National Renewable Energy Laboratory.). Builders face several key problems when implementing a whole-house systems integrated measures package (SIMP) from a single test house into multiple houses. Although a technical solution already may have been evaluated and validated in an individual test house, the potential exists for constructability failures at the community scale. This report addresses factors of implementation and scalability at the community scale and proposes methodologies by which community-scale energy evaluations can be performed based on results at the occupied test house level. Research focused on the builder and trade implementation of a SIMP and the actual utility usage in the houses at the community scale of production. Five occupants participated in this community-scale research by providing utility bills and information on occupancy and miscellaneous gas and electric appliance use for their houses. IBACOS used these utility data and background information to analyze the actual energy performance of the houses. Verification with measured data is an important component in predictive energy modeling. The actual utility bill readings were compared to projected energy consumption using BEopt with actual weather and thermostat set points for normalization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗