Search NASA⌕ Search

SEARCH · Search NASA

Results for “beta counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Near-infrared (Fe II) and Pa Beta imaging and spectroscopy of Arp 220

We have imaged the ultraluminous infrared galaxy Arp 220 in light of the near-infrared (Fe II) 1.257 micron and Pa-beta lines, and have obtained spectra in the J- and H-band atmospheric windows. Arp 220 is a strong source of (Fe II) and Pa-beta emission, with luminosities of 1.3 x 10(exp 41) and 9.2 x 10(exp 40) ergs/s, respectively. The (Fe II) and Pa-beta emission are both extended over the central 2 sec-3 sec, but with different morphologies. We suggest that the extended (Fe II) emission is produced through the interaction of fast shocks with ambient gas in the interstellar medium (ISM) at the base of the outflowing, supernovae-driven superwind mapped by Heckman et al. (1987). The bolometric luminosity of the starburst required to power this wind is estimated to be at least 2 x 10(exp 11) solar luminosity. If the spatially unresolved (Fe II) emission is produced via a large number of supernova remnants, the implied rate is approximately 0.6/yr. The overall luminosity of such a starburst could account for a large fraction (1/2-1/3) of the Arp 220 energy budget, but the large deficit of ionizing photons (as counted by the Pa-beta luminosity) requires that the starburst be rapidly declining and/or have a low upper mass cutoff. Alternatively, dust may effectively compete with the gas for ionizing photons, or much of the ionizing radiation may escape through 'holes' in the ISM. It is also possible that a buried active galactic nuclei (AGN) produces a large fraction of the unresolved (Fe II) and Pa-beta emission. We briefly discuss these possibilities in light of these new imaging and spectroscopic data.

Armus, L.↗

Concentration Independent Calibration of β-γ Coincidence Detector Using 131mXe and 133Xe

Absolute efficiency calibration of radiometric detectors is frequently difficult and requires careful detector modeling and accurate knowledge of the radioactive source used. In the past we have calibrated the b-g coincidence detector of the Automated Radioxenon Sampler/Analyzer (ARSA) using a variety of sources and techniques which have proven to be less than desirable.[1] A superior technique has been developed that uses the conversion-electron (CE) and x-ray coincidence of 131mXe to provide a more accurate absolute gamma efficiency of the detector. The 131mXe is injected directly into the beta cell of the coincident counting system and no knowledge of absolute source strength is required. In addition, 133Xe is used to provide a second independent means to obtain the absolute efficiency calibration. These two data points provide the necessary information for calculating the detector efficiency and can be used in conjunction with other noble gas isotopes to completely characterize and calibrate the ARSA nuclear detector. In this paper we discuss the techniques and results that we have obtained.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

First Year Wilkinson Microwave Anisotropy Probe (WMAP) Observations: Foreground Emission

The WMAP mission has mapped the full sky to determine the geometry, content, and evolution of the universe. Full sky maps are made in five microwave frequency bands to separate the temperature anisotropy of the cosmic microwave background (CMB) from foreground emission, including diffuse Galactic emission and Galactic and extragalactic point sources. We define masks that excise regions of high foreground emission, so CMB analyses can became out with minimal foreground contamination. We also present maps and spectra of the individual emission components, leading to an improved understanding of Galactic astrophysical processes. The effectiveness of template fits to remove foreground emission from the WMAP data is also examined. These efforts result in a CMB map with minimal contamination and a demonstration that the WMAP CMB power spectrum is insensitive to residual foreground emission. We use a Maximum Entropy Method to construct a model of the Galactic emission components. The observed total Galactic emission matches the model to less than 1% and the individual model components are accurate to a few percent. We find that the Milky Way resembles other normal spiral galaxies between 408 MHz and 23 GHz, with a synchrotron spectral index that is flattest (beta(sub s) approx. -2.5) near star-forming regions, especially in the plane, and steepest (beta(sub s) approx. -3) in the halo. This is consistent with a picture of relativistic cosmic ray electron generation in star-forming regions and diffusion and convection within the plane. The significant synchrotron index steepening out of the plane suggests a diffusion process in which the halo electrons are trapped in the Galactic potential long enough to suffer synchrotron and inverse Compton energy losses and hence a spectral steepening. The synchrotron index is steeper in the WMAP bands than in lower frequency radio surveys, with a spectral break near 20 GHz to beta(sub s) less than -3. The modeled thermal dust spectral index is also steep in the WMAP bands, with beta(sub d) approx. = 2.2. Our model is driven to these conclusions by the low level of total foreground contamination at approx. 60 GHz. Microwave and Ha measurements of the ionized gas agree well with one another at about the expected levels. Spinning dust emission is limited to less than 5% of the Ka-band foreground emission. A catalog of 208 point sources is presented. The reliability of the catalog is 98%, i.e., we expect five of the 208 sources to be statistically spurious. The mean spectral index of the point sources is alpha approx. 0(beta approx. -2). Derived source counts suggest a contribution to the anisotropy power from unresolved sources of (15.0 +/- 1.4) x 10(exp -3)micro sq K sr at Q-band and negligible levels at V-band and W-band. The Sunyaev-Zeldovich effect is shown to be a negligible "contamination" to the maps.

Bennett, C. L.↗

Identification and quantification of distinct active sites in Hf-Beta zeolites for transfer hydrogenation catalysis

Despite the significant progress made in characterizing different framework heteroatom sites that exist in Lewis acidic zeolites with probe molecule adsorption and spectroscopy, methods to reliably quantify site counts remain indefinite and have been primarily limited to Sn and Ti Lewis acid sites. Here, methods to quantify framework Lewis acidic Hf 4+ sites in zeolite Beta (Hf-Beta) with two Lewis base titrants (pyridine, deuterated acetonitrile) were developed using infrared (IR) spectroscopy. Lewis acid site counts for Hf-Beta zeolites were validated by measuring integrated molar extinction coefficients (IMECs; ε, cm μmol –1 ) on Sn-Beta zeolites using identical Lewis base titrants to benchmark site counts with established literature procedures to quantify Lewis acid sites in Beta zeolites from IR spectra. Highlighting the importance of benchmarking active site counts against well-established experimental protocols, IMECs of CD 3 CN bound to open (ε(Sn; 2316 cm –1 ): 1.80 ± 0.25) and closed (ε(Sn; 2308 cm –1 ): 3.76 ± 0.33) Sn sites were ~1.8x larger than those previously reported while total Lewis acid site counts agreed with those measured by pyridine (ε(Sn; 1451 cm –1 ): 1.58 ± 0.16) on six different Sn-Beta zeolites. IMECs measured for IR peaks reflecting pyridine bound to Lewis acidic Hf sites (ε(Hf; 1448 cm –1 ): 1.54 ± 0.21) and CD 3 CN bound to open (ε(Hf; 2313 cm –1 ): 2.40 ± 0.22) and closed (ε(Hf; 2307 cm –1 ): 3.55 ± 0.41) Hf sites, gave similar counts for the total number of Lewis acidic sites across six Hf-Beta zeolites (Si/Hf = 100–413). Consistent with previous reports with Sn-Beta catalysts where open Sn sites are responsible for catalytic turnover, apparent first and zero-order MPVO rate constants (0.01–1 M cyclohexanone in 2-butanol; per total Hf, 373 K) correlated with the total number of open Hf sites, per total Hf, but not with the total number of closed Hf sites or total Lewis acid site counts. Measured initial MPVO rates (0.1 M cyclohexanone in 2-butanol, per open Hf, 373 K) were ~25x higher on hydrophobic Hf-Beta-F than on hydrophilic Hf-Beta-OH zeolites. Overall, the apparent first-order MPVO rate constants (2-butanol solvent, per open Hf, 373 K) were ~6x higher on Hf-Beta-F than on Hf-Beta-OH zeolites. The characterization methods reported here enable normalization of MPVO turnover rates on Sn- and Hf-Beta zeolites by their number of open sites. Finally, this enables performing quantitative rate comparisons across Lewis acid zeolites of varying active site identity, solvation, and pore topology used in liquid-phase catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of an alpha/beta/gamma detector for radiation monitoring

For radiation monitoring at the site of nuclear power plant accidents such as Fukushima Daiichi, radiation detectors not only for gamma photons but also for alpha and beta particles are needed because some nuclear fission products emit beta particles and gamma photons and some nuclear fuels contain plutonium that emits alpha particles. We developed a radiation detector that can simultaneously monitor alpha and beta particles and gamma photons for radiation monitoring. The detector consists of three-layered scintillators optically coupled to each other and coupled to a photomultiplier tube. The first layer, which is made of a thin plastic scintillator (decay time: 2.4 ns), detects alpha particles. The second layer, which is made of a thin Gd{sub 2}SiO{sub 5} (GSO) scintillator with 1.5 mol.% Ce (decay time: 35 ns), detects beta particles. The third layer made of a thin GSO scintillator with 0.4 mol.% Ce (decay time: 70 ns) detects gamma photons. By using pulse shape discrimination, the count rates of these layers can be separated. With individual irradiation of alpha and beta particles and gamma photons, the count rate of the first layer represented the alpha particles, the second layer represented the beta particles, and the third layer represented the gamma photons. Even with simultaneous irradiation of the alpha and beta particles and the gamma photons, these three types of radiation can be individually monitored using correction for the gamma detection efficiency of the second and third layers. Our developed alpha, beta, and gamma detector is simple and will be useful for radiation monitoring, especially at nuclear power plant accident sites or other applications where the simultaneous measurements of alpha and beta particles and gamma photons are required.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Status of BetaCage: an Ultra-sensitive Screener for Surface Contamination

BetaCage, a gaseous neon time-projection chamber, has been proposed as a viable screener for emitters of low-energy alphas and electrons to which commercial radioactivity counting techniques are insensitive. Using radiopure materials for construction, active and passive shielding from extrinsic backgrounds, large counting area and minimal detector mass, BetaCage will be able to achieve sensitivities of 10{sup -5} counts keV{sup -1} kg{sup -1} day{sup -1} in a few days of running time. We report on progress in prototype development work since the last meeting of this workshop.

07 ISOTOPE AND RADIATION SOURCES↗

A CZT-based radioxenon detection system in support of the Comprehensive Nuclear-Test-Ban Treaty

Here in this work, a prototype radioxenon detection system was designed, developed and tested at Oregon State University to study the response of CdZnTe (CZT) detectors to xenon radioisotopes for monitoring nuclear explosions. The detector utilizes two coplanar CZT detectors and measures xenon radioisotopes through beta-gamma coincidence detection between the two detection elements. The CZT-based detection system offers excellent energy resolution and background count rate compared with scintillator-based beta-gamma coincidence detectors currently in operation at the IMS stations. In this paper, we briefly discuss the detector design and report our recent measurement results with 131mXe, 133mXe, and 133Xe produced in the TRIGA reactor at OSU.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Collective Analysis of Alpha Particle Losses Due to Self-Absorption by Mass Loading on Radioactive Particulate Glass Fiber Filters

In this study, we derived a relationship between filter mass loading and the percent loss during analysis using the mass loading data collected from six previous studies of self-absorption. Components of mass loading include particulate dust, radioactive particulates, and filter material. In a research report published in 1984, Higby calculated a minimum burial depth for an alpha particle to be lost due to absorption (100% loss) of about 3.7 mg/cm 2 based on calculations for the range of 239-Pu alpha particles in glass fiber filters. From there, Higby concluded that a correction factor of 0.85 assumes approximately 15% losses in the count rate of both alpha and beta particles. In 2000, Luetzelschwab et al. recommended assuming a 40% loss at a loading of 3.3 mg/cm 2 and a 28% loss for a loading of 2.3 mg/cm 2 which included the frontal face mass of the filter. More recently, the 100% losses due to absorption were reported to be in the 10 mg/cm 2 range. Presented here is a trinomial relationship method of relating percent loss due to self-absorption to filter mass loading, based on data reported by Higby, Luetzelschwab et al., Huang et al., Barnett et al., Smith et al., and Hogue et al. Under normal operating conditions at the stacks monitored by Effluent Management, the mass loading of sample filters averages 0.09 ± 0.12 (2s) mg/cm 2 (excluding negative values and outliers) and ranges from 0 mg/cm 2 to 0.24 mg/cm 2 . Based on current mass loading results for Effluent Management stack sample filters, the forced-zero trinomial relationship method estimated self-absorption losses of less than 5%. Because American National Standards Institute/Health Physics Society N13.1-2011 guidelines indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the count rate by more than 5%, it is possible continued application of a correction factor to the Effluent Management stack samples is no longer necessary. Nevertheless, continuing to assign a correction factor at the 5% threshold (i.e., 0.95) would be a conservative approach.

36 MATERIALS SCIENCE↗

Low background counting techniques at SNOLAB

Many of the experiments currently searching for dark matter, studying properties of neutrinos or searching for neutrinoless double beta decay require very low levels of radioactive backgrounds both in their own construction materials and in the surrounding environment. These low background levels are required so that the experiments can achieve the required sensitivities for their searches. SNOLAB has several facilities which are used to directly measure these radioactive backgrounds. This proceedings will describe SNOLAB's High Purity Germanium Detectors, one of which has been in continuous use for the past seven years measuring materials for many experiments in operation or under construction at SNOLAB. A description of the characterisation of SNOLAB's new germanium well detector will be presented. In addition, brief descriptions of SNOLAB's alpha-beta and electrostatic counters will be presented and a description of SNOLAB's future low background counting laboratory will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Thin Alumina Film as a Tritium Adsorption Inhibitor for Stainless Steel 316

The effect of a thin alumina coating on stainless-steel 316 (SS316) samples on tritium adsorption and transport are discussed. Compact films of alumina were produced on the surfaces of pristine SS316 samples using an atomic layer deposition (ALD) technique. Subsequently, these samples were exposed for 24 hours to a deuterium-tritium gas mixture (P T =0.5 atm, 25°C). A combination of methods including selective-etching and programmed thermal desorption were employed to assess both, the depth profile of the tritium concentration in the sample and the total quantity of tritium absorbed respectively. Tritium was quantitatively determined through the measurement of beta radioactivity using liquid-scintillation counting techniques. Data suggest that SS316 with a thin film of alumina reduces the total tritium uptake by ~25% relative to uncoated samples. Significantly, such films appear to reduce, by a factor of 200, tritium diffusion into SS316 and therefore constitute an effective barrier against tritium transport. This observation is of practical importance for tritium and, generally, reactive gas handling.

36 MATERIALS SCIENCE↗

Quadrupole moment measurements for strongly deformed bands in {sup 171,172}Hf

A lifetime experiment, using the Doppler-shift attenuation method, has been performed at Gammasphere to measure the transition quadrupole moments Q{sub t} of strongly deformed bands in {sup 171}Hf and {sup 172}Hf. The measured value of Q{sub t} {approx} 9.5 e b for the band labeled ED in {sup 171}Hf strongly supports the recent suggestion that this sequence and several structures with similar properties in neighboring Hf isotopes are associated with a near-prolate shape with a deformation enhanced relative to that of normal deformed structures. The measured values of Q{sub t} {approx} 14 e b for the bands labeled SD1 and SD3 in {sup 172}Hf confirm that these sequences are associated with a prolate superdeformed shape, a property inferred in earlier work from other measured characteristics of the bands. Similar bands in {sup 173-175}Hf are also likely to be associated with superdeformed shapes. The observations are in contrast to predictions of cranking calculations performed with the ultimate cranker code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precise measurement of $2νββ$ decay of $^{100}$Mo with the CUPID-Mo detection technology

We report the measurement of the two-neutrino double-beta ($2\nu\beta\beta$) decay of $^{100}$Mo to the ground state of $^{100}$Ru using lithium molybdate (\crystal) scintillating bolometers. The detectors were developed for the CUPID-Mo program and operated at the EDELWEISS-III low background facility in the Modane underground laboratory. From a total exposure of $42.235$ kg$\times$d, the half-life of $^{100}$Mo is determined to be $T_{1/2}^{2\nu}=[7.12^{+0.18}_{-0.14}\,\mathrm{(stat.)}\pm0.10\,\mathrm{(syst.)}]\times10^{18}$ years. This is the most accurate determination of the $2\nu\beta\beta$ half-life of $^{100}$Mo to date. We also confirm, with the statistical significance of $>3\sigma$, that the single-state dominance model of the $2\nu\beta\beta$ decay of $^{100}$Mo is favored over the high-state dominance model.

01 COAL, LIGNITE, AND PEAT↗

First results with a microcavity plasma panel detector

A new type of gaseous micropattern particle detector based on a closed-cell microcavity plasma panel sensor is reported. The first device was fabricated with 1 x 1 x 2 mm cells. It has shown very clean signals of 0.6-2.5 V amplitude, fast rise time of approximately 2 ns and FWHM of about 2 ns with very uniform signal shapes across all pixels. From initial measurements with beta particles from a radioactive source, a maximum pixel efficiency greater than 95% is calculated, for operation of the detector over a 100 V wide span of high voltages (HV). Over this same HV range, the background rate per pixel was measured to be 3-4 orders of magnitude lower than the rate with which the cell was illuminated by the beta source. Pixel-to-pixel count rate uniformity is within 3% and stable within 3% for many days. The time resolution is 2.4 ns, and a very low cell-to-cell crosstalk has been measured between cells separated by 2 mm. (C) 2014 Elsevier B.V. All rights reserved.

Ball, Robert↗

Micro cavity fission chamber radiation detection system

A radiation detector to monitor the neutron flux of a nuclear reactor or other high-radiation environment, that can withstand the high temperatures and radiation fields of such environment, is provided. A small dielectric substrate with a low neutron-activation cross section is provided. The substrate is coated with a neutron conversion material, such as uranium oxide or thorium oxide. One or more substrates form a micro-sized detection cavity that is filled with a detection gas. A voltage is provided across anode and cathode wires in the detection cavity. A neutron absorbed in the conversion material may release reaction products into the gas, causing ionization of the gas which then produces a current or voltage signal. The small detector volume minimizes energy deposition into the detection gas by competing particles such as gamma rays, fast electrons, and beta particles, and therefore minimizes false counts while retaining large signals from neutron interactions.

McGregor, Douglas S.↗

Alpha/beta-gated gamma–gamma spectroscopy of mixed fission products for trace analysis

This experiment demonstrated that some hard-to-detect fission products can be quantified directly from mixed fission product samples using advanced radio-emission spectroscopy techniques. A gamma/gamma coincidence detector was combined with a custom liquid scintillation counter to evaluate the benefits of alpha and beta coincident and anti-coincident analysis of mixed fission product samples. Reduction factors in the minimum detectable activity (MDA) relative to traditional gamma counting were quantified for a set of radionuclides. For isotopes like 91Y, 144Ce, 147Nd, and 153Sm MDA reductions of factors of 1-2 were observed using optimized beta thresholds. Using beta anti-coincidence counting reductions of factors 3-5 were observed for isotopes like 89Sr, 95mNb, 115Cd, and 137Cs and factors of 5-7 for isotopes like 235U using alpha coincidence counting. The selectivity of gamma/gamma coincidence and reduction in backgrounds using beta gating were also demonstrated with 136Cs and 153Sm. The improvements observed in the detection sensitivity of fission products and actinides achieved by combining time-correlated radiation signatures is significant and of value to applications such as nuclear fission physics, environmental monitoring for nuclear waste, reactor accidental releases, and nuclear forensics.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Comparison of fluence-rate determination techniques for the Advanced Test Reactor-Critical Facility

A technique using small, enriched uranium-aluminum alloy monitors to measure fission rates in fuel plate assembly reactors was developed at the Idaho National Laboratory Radiation Measurements Laboratory in support of Advanced Test Reactor Critical (ATR-C) Facility irradiations. Previous measurements were performed to determine the correlation between the beta-particle activity and the fission rate in the U-Al monitors following irradiation. The American Society for Testing and Materials (ASTM) has established a standard practice E704 for determining neutron fluence rate by radioactivation of depleted uranium by measuring the concentration of fission-products in irradiated uranium monitors. Rather than measuring the beta-particle decay from fission-products, the decay rate of fission-products is determined by gamma-ray spectroscopy. The feasibility of using a method adapted from the ASTM standard practice E704 was investigated for ATR-C irradiations and compared to the present method by analyzing a subset of 21 monitor wires using both methods. The resulting calculated fission rates agreed with an average standard deviation of 7.45%, within the average combined measurement error of 9.05%. Practical considerations such as expected fluence-rates, sample activity, and counting-time were compared between the two methods and the sources of error for each method were investigated. Quality assurance measurements utilizing the modified ASTM standard method are recommended for future test irradiation, but gross-beta-particle counting remains the most practical solution for ATR-C fluence-rate determination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Predicting Reactor Antineutrino Emissions Using New Precision Beta Spectroscopy

Neutrino experiments at nuclear reactors are currently vital to the study of neutrino oscillations. The observed antineutrino rates at reactors are typically lower than model expectations. This observed deficit is called the “reactor neutrino anomaly”. A new understanding of neutrino physics may be required to explain this deficit, though model estimation uncertainties may also play a role in the apparent discrepancy. PNNL is currently investigating an experimental technique that promises reduced uncertainties for measured data to support these hypotheses and interpret reactor antineutrino measurements. The experimental approach is to 1) direct a proton accelerator beam on a metal target to produce a source of neutrons, 2) use spectral tailoring to modify the neutron spectrum to closely simulate the energy distribution of a power reactor neutron spectrum, 3) irradiate isotopic fission foils (235U, 238U, 239Pu, 241Pu) in this neutron spectrum so that fissions occur at energies representative of a reactor, 4) transport the beta particles released by the fission products in the foils to a beta spectrometer, 5) measure the beta energy spectrum, and 6) invert the measured beta energy spectrum to an antineutrino energy spectrum. A similar technique using a beta spectrometer and isotopic fission foils was pioneered in the 1980’s at the ILL thermal reactor. Those measurements have been the basis for interpreting all subsequent antineutrino measurements at reactors. A basic constraint in efforts to reduce uncertainties in predicting the antineutrino emission from reactor cores is any underlying limitation of the original measurements. This may include beta spectrum energy resolution, the absolute normalization of beta emission to number of fission, statistical counting uncertainties, lack of 238U data, the purely thermal nature of the IIL reactor neutrons used, etc. An accelerator-based neutron source that can be tailored to match various reactor neutron spectra provides an advantage for control in studying how changes in the neutron spectra (i.e. "in the reactor core") affects the resulting fission product beta spectrum. Furthermore, the 238U antineutrino spectrum, which has not been measured, can be studied directly because of the enhanced 1 MeV fast neutron flux available at the accelerator source. A facility such as the Project X Injector Experiment (PXIE) 30 MeV proton linear accelerator at Fermilab is being considered for this experiment. The hypothesis is that a new approach utilizing the flexibility of an accelerator neutron source with spectral tailoring coupled with a careful design of an isotopic fission target and beta spectrometer and the inversion of the beta spectrum to the neutrino spectrum will allow further reduction in the uncertainties associated with prediction of the reactor antineutrino spectrum.

Asner, David M.↗