Search NASA⌕ Search

SEARCH · Search NASA

Results for “biomechanics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Probabilistic Modeling Of Ocular Biomechanics In VIIP: Risk Stratification

Visual Impairment and Intracranial Pressure (VIIP) syndrome is a major health concern for long-duration space missions. Currently, it is thought that a cephalad fluid shift in microgravity causes elevated intracranial pressure (ICP) that is transmitted along the optic nerve sheath (ONS). We hypothesize that this in turn leads to alteration and remodeling of connective tissue in the posterior eye which impacts vision. Finite element (FE) analysis is a powerful tool for examining the effects of mechanical loads in complex geometries. Our goal is to build a FE analysis framework to understand the response of the lamina cribrosa and optic nerve head to elevations in ICP in VIIP. To simulate the effects of different pressures on tissues in the posterior eye, we developed a geometric model of the posterior eye and optic nerve sheath and used a Latin hypercubepartial rank correlation coef-ficient (LHSPRCC) approach to assess the influence of uncertainty in our input parameters (i.e. pressures and material properties) on the peak strains within the retina, lamina cribrosa and optic nerve. The LHSPRCC approach was repeated for three relevant ICP ranges, corresponding to upright and supine posture on earth, and microgravity [1]. At each ICP condition we used intraocular pressure (IOP) and mean arterial pressure (MAP) measurements of in-flight astronauts provided by Lifetime Surveillance of Astronaut Health Program, NASA Johnson Space Center. The lamina cribrosa, optic nerve, retinal vessel and retina were modeled as linear-elastic materials, while other tissues were modeled as a Mooney-Rivlin solid (representing ground substance, stiffness parameter c1) with embedded collagen fibers (stiffness parameters c3, c4 and c5). Geometry creationmesh generation was done in Gmsh [2], while FEBio was used for all FE simulations [3]. The LHSPRCC approach resulted in correlation coefficients in the range of 1. To assess the relative influence of the uncertainty in an input parameter on the peak strains, we ranked and then normalized these coefficients, considering that normalized values 0.5 implied a substantial influence on the range of the peak strains in the optic nerve head (ONH). IOP and ICP were found to have a major influence on the peak strains in the ONH, as did optic nerve and LC stiffness. Interestingly, the stiffness of the sclera far from the scleral canal did not have a large influence on peak strains in ONH tissues; however, the collagen fiber stiffness in the peripapillary sclera and annular ring both influenced the peak strains within the ONH. We have created a physiologically relevant model that incorporated collagen fibers to study the effects of elevated ICP. Elevated ICP resulted in strains in the optic nerve that are not predicted to occur on earth: the upright or supine conditions. We found that IOP, ICP, lamina cribrosa stiffness and optic nerve stiffness had the highest association with these extreme strains in the ONH. These extreme strains may activate mechanosensitive cells that induce tissue remodeling and are a risk factor for the development of VIIP.

biomechanics↗

Analysis of Cell Biomechanics Response to Gravity:A Fluids for Biology Study Utilizing NASA Glenns Zero Gravity Research Facility

It remains unclear how biological cells sense and respond to gravitational forces. Leading scientists state that a large gap exists in the understanding of physiological and molecular adaptation that occurs as biology enters the spaceflight realm. We are seeking a method to fully understand how cells sense microgravity/gravity and what triggers their response.

cells↗

Effects of Single-Dose Versus Hypofractionated Focused Radiation on Vertebral Body Structure and Biomechanical Integrity: Development of a Rabbit Radiation-Induced Vertebral Compression Fracture Model

Vertebral compression fracture is a common complication of spinal stereotactic body radiation therapy. Development of an in vivo model is crucial to fully understand how focal radiation treatment affects vertebral integrity and biology at various dose fractionation regimens. We present a clinically relevant animal model to analyze the effects of localized, high-dose radiation on vertebral microstructure and mechanical integrity. Using this model, we test the hypothesis that fractionation of radiation dosing can reduce focused radiation therapy's harmful effects on the spine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hooks versus Pedicle Screws at the Upper Instrumented Level: An In Vitro Biomechanical Comparison

Study Design. Controlled laboratory study Objective. To compare motions at the upper instrumented vertebra (UIV) and supra-adjacent level (UIV+1) between two fixation techniques in thoracic posterior spinal fusion (PSF) constructs. We hypothesized there would be greater motion at UIV+1 after cyclic loading across all constructs and bilateral pedicle screws (BPS) with posterior ligamentous compromise would demonstrate the greatest UIV+1 range of motion (ROM). Summary of Background Data. Proximal junctional kyphosis (PJK) is a well-recognized complication following long thoraco-lumbar PSF, however its mechanism is poorly understood. Methods. Twenty-seven thoracic functional spine units (FSU) were randomly divided into three UIV fixation groups (n=9): (1) BPS, (2) bilateral transverse process hooks (TPH), and (3) BPS with compromise of the posterior elements between UIV and UIV+1 (BPS-C). Specimens were tested on a servohydraulic materials testing system in native state, following instrumentation, and after cyclic loading. FSUs were loaded in flexion-extension (FE), lateral bending (LB), and axial rotation (AR). Results. After cyclic testing, the TPH group had a mean 29.4% increase in FE ROM at UIV+1 versus 76.6% in the BPS group ( P <0.05). The BPS-C group showed an increased FE of 49.9% and 62.19% with sectioning of the facet joints and interspinous ligament respectively prior to cyclic testing. Conclusion. Bilateral pedicle screws at the UIV led to greater motion at UIV+1 compared to bilateral TPH after cyclic loading. This is likely due to the increased rigidity of BPS compared to TPH leading to a “softer” transition between the TPH construct and native anatomy at the supra-adjacent level. Facet capsule compromise led to a 49.9% increase in UIV+1 motion, underscoring the importance of preserving the posterior ligamentous complex. Clinical studies that account for fusion rates are warranted to determine if constructs with a “soft transition” result in less PJK in vivo.

Neurosciences & Neurology↗

Biomechanical Analysis of Multilevel Posterior Cervical Spinal Fusion Constructs

Study Design: Controlled Laboratory Study Objective: To compare multilevel posterior cervical fusion (PCF) constructs stopping at C7, T1, and T2 under cyclic load to determine the range of motion (ROM) between the lowest instrumented level and lowest instrumented-adjacent level (LIV-1). Summary of Background Data: PCF is a mainstay of treatment for various cervical spine conditions. The transition between the flexible cervical spine and rigid thoracic spine can lead to construct failure at the cervicothoracic junction. There is little evidence to determine the most appropriate level at which to stop a multilevel PCF. Methods: Fifteen human cadaveric cervicothoracic spines were randomly assigned to 1 of 3 treatment groups: PCF stopping at C7, T1, or T2. Specimens were tested in their native state, following a simulated PCF, and after cyclic loading. Specimens were loaded in flexion-extension), lateral bending, and axial rotation. Three-dimensional kinematics were recorded to evaluate ROM. Results: The C7 group had greater flexion-extension motion than the T1 and T2 groups following instrumentation (10.17±0.83 degree vs. 2.77±1.66 degree and 1.06±0.55 degree, P <0.001), and after cyclic loading (10.42±2.30 degree vs. 2.47±0.64 degree and 1.99±1.23 degree, P <0.001). There was no significant difference between the T1 and T2 groups. The C7 group had greater lateral bending ROM than both thoracic groups after instrumentation (8.81±3.44 degree vs. 3.51±2.52 degree, P =0.013 and 1.99±1.99 degree, P =0.003) and after cyclic loading. The C7 group had greater axial rotation motion than the thoracic groups (4.46±2.27 degree vs. 1.26±0.69 degree, P =0.010; and 0.73±0.74 degree, P =0.003) following cyclic loading. Conclusion: Motion at the cervicothoracic junction is significantly greater when a multilevel PCF stops at C7 rather than T1 or T2. This is likely attributable to the transition from a flexible cervical spine to a rigid thoracic spine. Although this does not account for in vivo fusion, surgeons should consider extending multilevel PCF constructs to T1 when feasible. Level of Evidence: Not applicable.

Neurosciences & Neurology↗

Acute Stent-Induced Endothelial Denudation: Biomechanical Predictors of Vascular Injury

Recent concern for local drug delivery and withdrawal of the first Food and Drug Administration-approved bioresorbable scaffold emphasizes the need to optimize the relationships between stent design and drug release with imposed arterial injury and observed pharmacodynamics. In this study, we examine the hypothesis that vascular injury is predictable from stent design and that the expanding force of stent deployment results in increased circumferential stress in the arterial tissue, which may explain acute injury poststent deployment. Using both numerical simulations and ex vivo experiments on three different stent designs (slotted tube, corrugated ring, and delta wing), arterial injury due to device deployment was examined. Furthermore, using numerical simulations, the consequence of changing stent strut radial thickness on arterial wall shear stress and arterial circumferential stress distributions was examined. Regions with predicted arterial circumferential stress exceeding a threshold of 49.5 kPa compared favorably with observed ex vivo endothelial denudation for the three considered stent designs. In addition, increasing strut thickness was predicted to result in more areas of denudation and larger areas exposed to low wall shear stress. We conclude that the acute arterial injury, observed immediately following stent expansion, is caused by high circumferential hoop stresses in the interstrut region, and denuded area profiles are dependent on unit cell geometric features. Such findings when coupled with where drugs move might explain the drug–device interactions.

Conway, Claire↗

Biomechanical studies in aerospace physiology

Weightlessness, high acceleration and aerospace vehicle maneuvering effects on cardiovascular and vestibular systems, discussing disorientation, space sicknesses and blood circulation

Anliker, M.↗

The determination of the operating range of a twin-grip control yoke through biomechanical means

A twin-grip control yoke was designed as an ergonomic case study that allows dual axis control inputs, both axes being rotational. Inputs are effected by rotating the grips. How the handles were designed with respect to their shape and size and how the angular range of the control yoke in both rotational axes was evaluated. The control yoke which requires two-hand operation was tested to determine its operating range. The intention of this investigation was to find out the optimal form of the control yoke and the maximum permissible range in both rotating axes. In these experiments controls had no spring resistance.

Gaertner, K. P.↗

Moments applied in the manual assembly of space structures - Ease biomechanics results from STS-61B

Measurements of the level and pattern of moments applied in the manual assembly of a space structure were made in extravehicular activity (EVA) and neutral buoyancy simulation (NBS). The Experimental Assembly of Structures in EVA program included the repeated assembly of a 3.6 m tetrahedral truss structure in EVA on STS-61B after extensive neutral buoyancy crew training. The flight and training structures were of equivalent mass and geometry to allow a direct correlation between EVA and NBS performance. A stereo photographic motion camera system was used to reconstruct in three dimensions rotational movements of structural beams during assembly. Moments applied in these manual handling tasks were calculated on the basis of the reconstructed movements taking into account effects of inertia, drag and virtual mass. Applied moments of 2.0 Nm were typical for beam rotations in EVA. Corresponding applied moments in NBS were typically up to five times greater. Moments were applied as impulses separated by several seconds of coasting in both EVA and NBS. Decelerating impulses were only infrequently observed in NBS.

Cousins, D.↗

Interactive effects of nutrition, environment, and rat-strain on cortical and vertebral bone geometry and biomechanics

An investigation was conducted to generate comparative data on the sensitivity of cortical- and vertebral-bone adaptations in two different rat strains maintained at conditions typical for spaceborne experiments conducted by U.S.A. and USSR. The effects of cage environment, diet, and rat-strain on the cortical (humerus) and vertebral (T7) bones of male Taconic-Sprague-Dawley and Czechoslovakian-Wistar rats were investigated using different flight-simulation cages (one rat/cage for U.S.A.; ten rats/cage for USSR conditions) and fed either U.S.A. or USSR diet. The results showed significant effects of these factors on the humeral and vertebral geometry and mechanical properties, as well as significant interactive effects on the mechanical properties of the humerus.

Zernicke, R. F.↗

Changes in geometrical and biomechanical properties of immature male and female rat tibia

The differences in the geometry and mechanical properties of immature male and female rat tibiae were detailed in order to provide comparative data for spaceflight, exercise, or disease experiments that use immature rats as an animal model. The experiment focuses on the particularly rapid period of growth that occurs in the Sprague-Dawley rat between 40 and 60 d of age. Tibial length and middiaphysical cross-sectional data were analyzed for eight different groups of rats according to age and sex, and tibial mechanical properties were obtained via three-point bending tests to failure. Results indicate that, during the 15 d period of rapid growth, changes in rat tibial geometry are more important than changes in bone material properties for influencing the mechanical properties of the tibia. Male tibiae changed primarily in structural properties, while in the female rats major changes in mechanical properties of the tibia were only attributable to changes in the structural properties of the bone.

Zernicke, Ronald F.↗

Development of an empirically based dynamic biomechanical strength model

The focus here is on the development of a dynamic strength model for humans. Our model is based on empirical data. The shoulder, elbow, and wrist joints are characterized in terms of maximum isolated torque, position, and velocity in all rotational planes. This information is reduced by a least squares regression technique into a table of single variable second degree polynomial equations determining the torque as a function of position and velocity. The isolated joint torque equations are then used to compute forces resulting from a composite motion, which in this case is a ratchet wrench push and pull operation. What is presented here is a comparison of the computed or predicted results of the model with the actual measured values for the composite motion.

Pandya, A.↗