Search NASA⌕ Search

SEARCH · Search NASA

Results for “bus frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Developing a PSCAD Model of the Reduced 240-Bus WECC Test System: Preprint

Fast-acting controls of inverter-based resources (IBR) introduce unprecedented dynamics to bulk power systems and island power grids, especially the high-frequency dynamics ranging from $>5$ Hz to hundreds of Hz. These oscillatory stability problems cannot be captured by the phasor domain simulations, e.g., in PSS/E, Powerworld and TSAT, due to insufficient modeling. Instead, they should be studied by electromagnetic transient (EMT) simulations by using proper EMT dynamic models. This paper develops and validates the PSCAD model of the reduced 240-bus Western Electricity Coordinating Council (WECC) test system. The PSCAD model will be released to the public, which can be used by both academia and power industry practitioners for studying the fast dynamic problems without any Critical Energy/Electric Infrastructure Information (CEII).

240-bus WECC test system↗

Developing of Quaternary Pumped Storage Hydropower for Dynamic Studies

Quaternary pumped storage hydropower (Q-PSH) technology, as one of the new advanced-PSH technology, has been developed by taking advantage of Conventional-PSH (C-PSH) and Adjustable Speed-PSH (AS-PSH). By combining adjustable-speed pump unit and conventional hydropower turbine unit in the quaternary configuration, Q-PSH has the more competitive capability of providing fast power support in the future high renewable penetrated power system. Acting as energy storage (ES), Q-PSH provides promising power supply to deal with the uncertainty and variability from renewable energy generation. This paper focuses on the dynamic modeling of Q-PSH technology employing full-converter machine and the impact of Q-PSH on the frequency response in a system. The detailed model of Q-PSH is developed and implemented in the IEEE 14-bus system based on GE Positive Sequence Load Flow (PSLF) platform, which captures the dynamic of multiple operation modes, especially hydraulic short-circuit (HSC) operation mode. Several cases are set up to reveal the advantages of Q-PSH technology when power electronic based renewable energy generation is deployed in the system. Sensitivity studies of the controller in pump governor show the impact of parameters in pump response performance. The comparison case illustrates the impact of frequency response provided by the Q-PSH in the system.

dynamic modeling↗

Coordinated Frequency Regulation in Grid-Forming Storage Network via Safety-Consensus

Inverter-based storages are poised to play a prominent role in future power grid with massive renewable generation. Grid-forming inverters (GFMs) are emerging as a dominant technology with synchronous generators (SG)-like characteristics through primary control loops. Advanced secondary-layer control schemes, e.g., consensus algorithms, allow GFM-interfaced storage units to participate in frequency regulations and restore nominal frequency following grid disturbances. However, it is imperative to ensure critical frequency safety limits are not violated while the grid transitions from pre- to post-disturbance operating point. This paper presents a novel safety-enforced consensus method, having three distinct objectives: safe transient frequency evolution, minimizing frequency deviation, and coordinated power sharing. The proposed technique is illustrated using a GFM-interfaced grid-wide storage network on the IEEE 68-bus system under multiple grid transient scenarios.

consensus control↗

Impedance-Based Prediction of SSR-Generated Harmonics in Doubly-Fed Induction Generators

Doubly-fed induction generators (DFIGs) are prone to subsynchronous resonance (SSR) with series-compensated transmission lines and experiencing SSR-generated harmonics of wide-ranging magnitudes. This paper presents a large-signal impedance-based approach for the prediction of the magnitude of SSR-generated harmonics in DFIGs. Note that the large-signal impedance of a network shows variation in its impedance response with the magnitude of perturbation at its terminals. It is discovered in this paper that the impedance of a series-compen- sated transmission line starts changing with the magnitude of SSR because of the metal-oxide varistor-based protection of series capacitors in the line. The changing line impedance halts the growth of the SSR beyond a certain point, where the DFIG forms a limit-cycle mode and emits harmonics at the SSR frequency. The discovered role of the protection of series capacitors in SSR not only enables the prediction of SSR-generated harmonics but also can be used for the timely detection of an SSR event to avoid system disruption and sudden loss of bulk generation. The large- signal impedance-based prediction of SSR-generated harmonics in DFIG-based wind and hydro generators is demonstrated using numerical simulations of a 2.5-MVA, 690-V DFIG supplying to a series-compensated transmission line.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Control for Fast Frequency Response and Black-Start using Embedded Storages with Grid-Forming Control

The grid-forming inverter is regarded as the solution for integrating high levels of renewable resources into future power systems. Ensuring the stable operation of grids necessitates that grid-forming inverters offer fast frequency response. This report introduces an optimal control method that coordinates the embedded storage within the grid-forming control model with conventional synchronous generators. The optimized active power reference for the embedded storage is generated using receding horizon optimization control, aiming to keep the center of inertia frequency within acceptable limits. The effectiveness of the proposed control is verified through testing in the IEEE 39-bus system. In addition, with grid-forming capability, we will also investigate the application of using mobile embedded storages as black-start units to provide cranking power to energize non-blackstart generators in a black-start process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Intelligent, grid-friendly, modular extreme fast charging system with solid-state DC protection

The development of electric vehicle (EV) charging infrastructure is crucial for the widespread adoption of electric transportation. However, implementing such infrastructure is a complex task that requires consideration of factors such as space limitations, adherence to industry standards, grid capacity, and other technical and policy issues. This project seeks to create a framework for the efficient design of compact medium voltage (MV) extreme fast charging (XFC) stations for EVs. The station design involves the use of a solid-state transformer (SST) that connects to the MV distribution network, delivering power to a shared DC bus. This innovative approach eliminates the need for a step-down transformer to provide low-voltage service by connecting directly to the MV distribution network. Eliminating the low-frequency transformer not only reduces the system footprint and losses but also eliminates inrush currents during grid black-start. Additionally, placing power electronics directly on the distribution system allows for high-bandwidth filtering and power factor correction. The inclusion of a shared DC bus enables multiple charging dispensers and DC storage/generation units to connect, forming a DC microgrid. This setup facilitates power sharing with minimal conversion stages. The project showcases a DC distribution network protected by intelligent solid-state (SS) DC circuit breakers (DCCB) capable of isolating the smallest section of the faulted circuit much faster than existing mechanical solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-speed silicon microresonator modulators with high optical modulation amplitude (OMA) at input powers >10 mW

A high-speed silicon photonic microdisc modulator is used with more than 10 mW optical power in the bus waveguide, extending the optical power handling regime used with compact silicon resonant modulators at 1550 nm. We present an experimental study of the wavelength tuning range and biasing path required to shift the resonant frequency to the optimal point versus on chip power. We measure the optical modulation amplitude (OMA) along different biasing trajectories of the microdisc under active modulation and demonstrate an OMA of 4.1 mW with 13.5 mW optical power in the bus waveguide at 20 Gbit/s non-return to zero (NRZ) data modulation.

Wang, Xiaoxi↗

36 Hz integral linewidth laser based on a photonic integrated 4.0 m coil resonator

Laser stabilization sits at the heart of many precision scientific experiments and applications, including quantum information science, metrology, and atomic timekeeping. Many of these systems narrow the laser linewidth and stabilize the carrier by use of Pound–Drever–Hall (PDH) locking to a table-scale, ultrahigh quality factor (Q), vacuum spaced Fabry–Perot reference cavity. Integrating these cavities to bring characteristics of PDH stabilization to the chip scale is critical to reducing their size, cost, and weight, and enabling a wide range of portable and system-on-chip applications. We report a significant advance in integrated laser linewidth narrowing, stabilization, and noise reduction by use of a photonic integrated 4.0 m long coil resonator to stabilize a semiconductor laser. We achieve a 36 Hz 1 / π <#comment/> -integral linewidth, Allan deviation of 1.8 × <#comment/> 10 − <#comment/> 13 at 10 ms measurement time, and a 2.3 kHz/s drift—to the best of our knowledge, the lowest integral linewidth and highest stability demonstrated for an integrated waveguide reference cavity. This performance represents over an order of magnitude improvement in integral linewidth and frequency noise over previous integrated waveguide PDH stabilized reference cavities and bulk-optic and integrated injection locked approaches, and over two orders of magnitude improvement in frequency and phase noise than integrated injection locked approaches. Two different wavelength coil designs are demonstrated, stabilizing lasers at 1550 nm and 1319 nm. The resonator is bus-coupled to a 4.0 m long coil, with a 49 MHz free spectral range, mode volume of 1.0 × <#comment/> 10 10 µ <#comment/> m 3 , and 142 million intrinsic Q , fabricated in a CMOS compatible, ultralow loss silicon nitride waveguide platform. Our measurements and simulations show that the thermorefractive noise floor for this particular cavity is reached for frequencies down to 20 Hz in an ambient environment with simple passive vibration isolation and without vacuum or thermal isolation. The thermorefractive noise limited performance is estimated to yield an 8 Hz 1 / π <#comment/> -integral linewidth and Allan deviation of 5 × <#comment/> 10 − <#comment/> 14 at 10 ms, opening a stability regime that heretofore has been available only in fundamentally non-integrated systems. These results demonstrate the potential to bring the characteristics of laboratory-scale stabilized lasers to the integrated, wafer-scale compatible chip scale, and are of interest for a number of applications in quantum technologies and atomic, molecular, and optical physics, and with further developments below 10 Hz linewidth, can be highly relevant to ultralow noise microwave generation.

Liu, Kaikai (ORCID:0000000213609646)↗

Joint Design of Multimodal Transit Networks and Shared Autonomous Mobility Fleets

Providing quality transit service to travelers in low-density areas, particularly travelers without personal vehicles, is a constant challenge for transit agencies. The advent of fully-autonomous vehicles (AVs) and their inclusion in mobility service fleets may allow transit agencies to offer better service and/or reduce their own capital and operational costs. This study focuses on the problem of allocating resources between transit patterns and operating (or subsidizing) shared-use AV mobility services (SAMSs) in a large metropolitan area. To address this question, a joint transit network redesign and SAMS fleet size determination problem (JTNR-SFSDP) is introduced, and a bi-level mathematical programming formulation and solution approach are presented. The upper-level problem modifies a transit network frequency setting problem (TNFSP) formulation via incorporating SAMS fleet size as a decision variable and allowing the removal of bus routes. The lower-level problem consists of a dynamic combined mode choice-traveler assignment problem (DCMC-TAP) formulation. The heuristic solution procedure involves solving the upper-level problem using a nonlinear programming solver and solving the lower-level problem using an iterative agent-based assignment-simulation approach. To illustrate the effectiveness of the modeling framework, this study uses traveler demand from Chicago along with the regions existing multimodal transit network. The computational results indicate significant traveler benefits, in terms of improved average traveler wait times, associated with optimizing the joint design of multimodal transit networks and SAMS fleets compared with the initial transit network design.

bi-level programming↗

Control Oriented Models for Co-Design: Technical Overview of MT HVDC, MVDC, and Solid State Transformer Building Blocks

The electric power system is shifting toward a power electronics–enabled grid, where converter based “building blocks” (e.g., high voltage direct current (HVDC) links, multi terminal HVDC (MT HVDC) networks, medium voltage DC (MVDC) links, and solid state transformers (SSTs)) provide fast, precise control of power flows, voltage, and frequency. This report develops and applies publicly shareable electromagnetic transient (EMT) and phasor models to examine how such building blocks can be composed and coordinated to support offshore wind integration, inter area transfers, feeder support, and resilience. Section 2 documents a modular multilevel converter (MMC)–based MT HVDC modeling framework and two use cases: a compact WSCC/IEEE 9 bus test system and a 240 bus “mini WECC” case with five offshore wind plants (OWFs). Phasor to EMT transfer, initialization, and sanity checks are summarized, and neutral demonstrations of normal and contingency operation are reported. Section 3 frames the problem of wind plant inertial frequency response (IFR): shaping energy release and recovery to improve nadir while avoiding aerodynamic stall; representative simulations illustrate the issues without disclosing proprietary control. Section 4 develops MVDC concepts through an IEEE 16 bus loop and an Olympic Peninsula case study that compares AC vs. MVDC corridors and shows how feeder headroom can be pooled via DC couplers. Section 5 surveys SST architectures and identifies a gap: scalable, communication free coordination of multiple SSTs for islanded feeder networks. Across the report, novel methods and configurations under separate publication and IP review are not disclosed; only topic oriented, replicable setups and non proprietary results are shown. These models and use cases are intended as foundations for future publications and co design studies on architecture, control, and coordination of PE enabled grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Athena - Shuttle Bus Optimization and Event Driven Simulator [SWR 20-105]

The primary purpose of the software is to optimize shuttle routes to and from terminals, given some airport campus location like the rental car center. This code was developed as part of the DOE funded Athena project. One aspect of the Athena project was to investigate if the optimization of shuttle routes that move passengers to and from the five DFW terminals and the rental car center could result in lower energy consumption from the shuttle fleet while still maintaining an acceptable level of service to passengers. Hence, the optimization done by the code determines a set of shuttle routes, the type of shuttle on each route, and the number of shuttles servicing each route. The optimization aims to make these choices in a way that the energy consumption per hour by the fleet is minimized. Additionally, the software can fast simulate airport shuttle operations with collected data. The simulation inputs are passenger arrival rates, shuttle routes and frequencies, and simulation configurations. The outputs include: time dependent shuttle energy level, time dependent charging station usage, time dependent number of passengers on each bus, time dependent number of passengers at each bus stop, history of number of passengers left at each bus stop, route history of fleet shuttle buses and on-demand buses, and time dependent bus distance traveled.

Kelly, Kenneth↗

Next-Generation, High-temperature, High-frequency, High-efficiency, High-power-density Traction System

To meet performance and reliability requirements necessary for broader adoption of electric drive vehicles, the Electrical and Electronics Technical Team of the U.S. Drive partnership has established aggressive design goals for next-generation electric vehicle drivetrains. Specifically, the 2025 roadmap stipulates a 100 kW/L power density target and a $\$$2.7/kW cost target for power electronics, in addition to high-voltage operation (i.e., greater than 800 VDC). The additional targets for traction motor and the overall system performance impose further challenges on the power electronics design. For example, many high specific power machines have reduced iron content, and therefore reduced intrinsic filtering, thus requiring the inverter to supply a low-distortion drive current. These machines also typically have a high pole count, thus requiring drive current at a higher electrical frequency. Other motors, such as brush-less dc and switch reluctance machines, require a carefully-shaped, non-sinusoidal drive current (Yang, Shang, Brown, & Krishnamurthy, 2015), (Zhang, Bowman, O'Connel, & Haran, 2018), (Anderson, et al., 2018). Two- and three-level inverter topologies are the conventional framework for the power electronics design of the drivetrain, and some demonstrations have shown recent progress towards addressing cost, power density and efficiency goals (Gurpinar & Ozpineci, 2018), (Zhu, Kim, Chen, Erickson, & Maksimović, 2018), (Deshpande, Chen, Narayanasamy, Sathyanarayanan, & Luo, 2018), (Alizadeh, et al., 2019). However, an unconventional approach may be necessary to take the dramatic leap in power density necessitated by the roadmap—while simultaneously addressing the other system needs. Therefore, this project leverages the flying capacitor multilevel (FCML) topology, together with a scalable, modular approach, to address these needs. This type of hybrid converter has several advantages: lower voltage (i.e., less than 300 V) transistors can be used, energy-dense capacitors process most of the power, and the output current waveform is multilevel and exhibits a frequency multiplying effect—in other words, the output has reduced dv/dt and filtering requirements for the same high voltage dc bus. For example, in an electric vehicle with an 800 V bus, a 10-level FCML could leverage 100 V, commercially available GaN devices switching at 115 kHz to produce a ~1 MHz switching waveform (modulated according to the motor drive requirements) with one ninth of the dv/dt of a two-level converter. Prior work has already demonstrated promising performance and gravimetric power density figures for more electric aircraft applications (Pallo, Foulkes, Modeer, Coday, & Pilawa-Podgurski, 2018). This project leverages lessons learned to achieve the volumetric power density of 100 kW/L by employing advanced liquid cooling, address the 300,000 mile reliability challenge with redundant design, topology failure studies and online health monitoring, and reduce costs to $\$$2.7/kW through the use of low-cost GaN devices, modular converter assemblies, and modest modifications to traditional manufacturing methods. The project involved several hardware designs, each achieving increasing performance. At the conclusion of the project, a volumetric power density of 380 kW/L was achieved, in a 800V dc-ac converter, greatly surpassing even the aggressive target goal.

33 ADVANCED PROPULSION SYSTEMS↗

Nominal and adversarial synthetic PMU data for standard IEEE test systems

GridSTAGE (Spatio-Temporal Adversarial scenario GEneration) is a framework for the simulation of adversarial scenarios and the generation of multivariate spatio-temporal data in cyber-physical systems. GridSTAGE is developed based on Matlab and leverages Power System Toolbox (PST) where the evolution of the power network is governed by nonlinear differential equations. Using GridSTAGE, one can create several event scenarios that correspond to several operating states of the power network by enabling or disabling any of the following: faults, AGC control, PSS control, exciter control, load changes, generation changes, and different types of cyber-attacks. Standard IEEE bus system data is used to define the power system environment. GridSTAGE emulates the data from PMU and SCADA sensors. The rate of frequency and location of the sensors can be adjusted as well. Detailed instructions on generating data scenarios with different system topologies, attack characteristics, load characteristics, sensor configuration, control parameters are available in the Github repository - https://github.com/pnnl/GridSTAGE. There is no existing adversarial data-generation framework that can incorporate several attack characteristics and yield adversarial PMU data. The GridSTAGE framework currently supports simulation of False Data Injection attacks (such as a ramp, step, random, trapezoidal, multiplicative, replay, freezing) and Denial of Service attacks (such as time-delay, packet-loss) on PMU data. Furthermore, it supports generating spatio-temporal time-series data corresponding to several random load changes across the network or corresponding to several generation changes. A Koopman mode decomposition (KMD) based algorithm to detect and identify the false data attacks in real-time is proposed in https://ieeexplore.ieee.org/document/9303022. Machine learning-based predictive models are developed to capture the dynamics of the underlying power system with a high level of accuracy under various operating conditions for IEEE 68 bus system. The corresponding machine learning models are available at https://github.com/pnnl/grid_prediction.

99 GENERAL AND MISCELLANEOUS↗

A Methodology to Evaluate the Grid Reliability Impact of Oscillations Induced by Large Loads

The rapid growth of hyperscale AI data centers is bringing renewed attention to the reliability risk that sustained forced oscillations pose to bulk power systems, with cyclic computational workloads emerging as a new forcing source. Unlike the broadband, stochastic disturbances from traditional industrial loads such as arc furnaces, AI training and inference facilities can inject large active power swings concentrated at specific frequencies over extended durations - characteristics that existing grid planning practices do not account for. While the North American Electric Reliability Corporation (NERC) has recognized this gap and called for system-level studies of large load interconnections, no standardized methodology exists to screen, simulate, and quantify these risks at the planning stage. This report presents the Risk Assessment Tool for Large Load-induced Events (RATLLE), a Python-based, publicly available script suite developed at the Pacific Northwest National Laboratory to evaluate bulk power system reliability risks from data center-induced oscillations. RATLLE implements a three-module workflow: a screening module that identifies vulnerable interconnection locations and excitable system modes; a simulation module that models cyclic data center load behavior using a commercial positive sequence simulation platform; and an analysis module that computes risk metrics and generates interactive visualization dashboards. The risk metrics, formulated around simulation observables, map oscillation impacts to a three-stage severity scale spanning latent equipment fatigue through imminent cascading failure. The methodology is demonstrated on two Western Electricity Coordinating Council (WECC) system models: a publicly available 240-bus reduced representation and a detailed 2031 Heavy Winter planning case. Case studies illustrate that even modest 50 MW forced oscillations at resonant frequencies can produce wide-area power swings, N-1 security constraint violations, and cascading generator trips through protection actions - outcomes that would not occur under normal operating conditions without oscillations present. The results underscore the need for standardized oscillation impact assessment in large load interconnection studies and provide a reproducible, extensible framework for utilities to adopt or customize within their existing planning workflows.

Biswas, Shuchismita↗

Sparse Control Synthesis for Uncertain Responsive Loads With Stochastic Stability Guarantees

In this report, recent studies have demonstrated the potential of flexible loads in providing frequency response services, predominantly due to their availability and cost-effectiveness. However, uncertainty and variability in various weather-related and end-use behavioral factors often impact the reliability of demand-side control performance. This work addresses this problem with the design of a demand-side control to achieve frequency response under load uncertainties. Our approach involves modeling the load uncertainties via stochastic processes that appear as both multiplicative and additive in the power system dynamics. Recently developed mean square exponential stability (MSES) results for continuous-time linear stochastic systems are applied to pose the control synthesis problem which results in an LMI-based optimization problem. Additional costs and constraints are added to the LMI-based controller synthesis to ensure MSES, improve closed-loop transient performance, maximize tolerable uncertainties, and promote sparsity in the controller. Additionally, the fundamental limitations between the tolerable uncertainties and control efforts while ensuring MSES are discussed. Further, the control synthesis problem for the case of the full-state measurement is generalized to the case of partial-state measurements. The proposed control synthesis is illustrated on an IEEE 39 bus system with rigorous studies to demonstrate the role of sparsity, closed-loop transient performance, tolerable uncertainties, and control efforts while ensuring MSES and achieving frequency response.

42 ENGINEERING↗

Open-Source Ambient-Signal-Based Inertia Monitoring Tool for Power systems [SWR-25-59]

This script, developed by NREL, implements an inertia estimation algorithm using a sliding window approach. The inertia (H) is estimated based on frequency deviations and active power deviations, utilizing the swing equation from power system dynamics. An example application is provided using the WECC 240-bus system.

Peng, Jiangkai [National Renewable Energy Laborato↗