MFC Communications Infrastructure Study

Unprecedented growth of required telecommunications services and telecommunications applications change the way the INL does business today. High speed connectivity compiled with a high demand for telephony and network services requires a robust communications infrastructure. The current state of the MFC communication infrastructure limits growth opportunities of current and future communication infrastructure services. This limitation is largely due to equipment capacity issues, aging cabling infrastructure (external/internal fiber and copper cable) and inadequate space for telecommunication equipment. While some communication infrastructure improvements have been implemented over time projects, it has been completed without a clear overall plan and technology standard. This document identifies critical deficiencies with the current state of the communication infrastructure in operation at the MFC facilities and provides an analysis to identify needs and deficiencies to be addressed in order to achieve target architectural standards as defined in STD-170. The intent of STD-170 is to provide a robust, flexible, long-term solution to make communications capabilities align with the INL mission and fit the various programmatic growth and expansion needs.

97 MATHEMATICS AND COMPUTING↗

Inter-digital capacitive sensor for evaluating cable jacket and insulation aging

An inter-digital capacitive (TDC) sensor has previously been used to measure dielectric properties of cable insulation polymer material when placed in direct contact with the insulation. Often cable insulation is covered by a polymer jacket. The dielectric properties of many cable jacket and insulation polymers are known to change due to thermal and radiation exposure-related damage. These dielectric properties frequently track with other measures of cable aging, such as tensile elongation-at-break and indenter modulus that have been broadly established as cable insulation polymer assessment methods. The external jacket of a cable is likely to have a different permittivity from the underlying insulation, and frequently the jacket material exhibits more severe damage than the insulation material due to environmental exposure. Because the jacket serves primarily to guard the cable during installation, as long as the underlying insulation condition is acceptable, the jacket condition is relatively unimportant in service. As part of a continuing program to develop and evaluate nondestructive examination methods that may be applied to cable condition assessment, a set of tools has been developed including (1) a parallel-plate sensor to directly measure the permittivity spectrum of flat sheet material and (2) an TDC and fixture to measure the effect of cable polymer dielectric property change on the sensor response. The TDC consists of two fork-like electrodes facing each other with the fork tines interspersed and separated by a small gap. The electrodes are printed on one side of a flexible substrate that can be conformed to the surface of a cylindrical cable, with tines parallel to the cable axis. The electrodes are connected to a broad-frequency-spectral impedance meter that senses the capacitance between the narrowly gapped electrode tines. This capacitance is known to vary as a function of the permittivity of any material in close proximity to the electrodes. By finite element modeling (FEM) and experimentation, this study investigates the effect of tine spacing and other design parameters associated with the TDC on the voltage (potential) distribution and electric field depth of penetration. The TDC measurement of an unshielded ethylene-propylene rubber (EPR)-insulated cable is shown to track with the degree of aging and quantities obtained by established methods. For jacketed cable systems, the TDC response is dominated by the jacket but, by analyzing measurements from TDC sensors with different depths-of-field penetration into the cable under test, the influence of the chlorinated polyethylene (CPE) cable jacket material degradation can be separated from an assessment of the cable insulation thereby enabling assessment of the insulation beneath/through the jacket.

Cable NDE, Interdigital Capacitance, Cable test↗

LONG TERM OPERATION ISSUES FOR ELECTRICAL CABLE SYSTEMS IN NUCLEAR POWER PLANTS

Nuclear power plants contain hundreds of kilometers of electrical cables including cables used for power, for instrumentation, and for control. It is essential that safety-related cable systems continue to perform following a design-basis event. Wholesale replacement of electrical cables in existing plants facing licensing period renewal is both impractical and cost-prohibitive. It is therefore important to understand the long term aging of cable materials to have confidence that aged cables will perform when needed. It is equally important in support of cable aging management to develop methods to evaluate the health of installed cables and inform selective cable replacement decisions. The most common insulation materials for electrical cables in nuclear power plants are cross-linked polyethylene and ethylene-propylene rubber. The mechanical properties of these materials degrade over time in the presence of environmental stresses including heat, gamma irradiation, and moisture. Mechanical degradation of cable insulation beyond a certain threshold is unacceptable because it can lead to insulation cracking, exposure of energized conductors, arcing and burning or loss of the ability of the cable system to function during a design-basis accident. While thermal-, radiation-, and moisture-related degradation of polymer insulation materials has been extensively studied over the last few decades, questions remain regarding the long-term performance of cable materials in nuclear plant-specific environments. Identified knowledge gaps include an understanding of the temperature-dependence of activation energies for thermal damage and an understanding of the synergistic effects of radiation and thermal stress on polymer degradation. Many of the outstanding questions in the aging behavior of cable materials relate to the necessity of predicting long-term field degradation using accelerated aging results from the laboratory. Materials degrade faster under more extreme conditions, but extension of behavior to long term degradation under more mild conditions, such as those experienced by most installed cables in nuclear power plants, is complicated by the fact that different degradation mechanisms may be involved in extreme and mild scenarios. The discrepancy in predicted results from short term, more extreme exposure and actual results from longer term, more mild exposures can be counter intuitive. For instance, due to the attenuation of oxidation penetration in material samples rapidly aged through exposure to high temperatures, the bulk of the samples may be artificially protected from thermal aging. In another example, simultaneous exposure of cable insulation material to heat and radiation may actually lead to less damage at higher temperatures than may be observed at lower temperatures. The Light Water Reactor Sustainability program of the United States (US) Department of Energy Office (DOE) of Nuclear Energy is funding research to increase the predictive understanding of electrical cable material aging and degradation in existing nuclear power plants in support of continued safe operation of plants beyond their initial license periods. This research includes the evaluation and development of methods to assess installed cable condition.

Fifield, Dr Leonard S↗

Correlation of Diffusion Limited Oxidation to Color Difference in Accelerated Aging of Electrical Cable Insulation

Diffusion limited oxidation (DLO) as a phenomenon has complicated material lifetime predictions from accelerated aging studies. Many methods to analyze DLO have been developed in recent years. However, an analytical tool for high throughput and low-cost analysis of DLO affected samples remains absent from the literature. Color differences in polymers exposed to oxidative conditions have recently been observed and correlated to increased concentrations of oxidation products. Herein, total color difference was utilized to rapidly quantify DLO in ethylene propylene rubber (EPR) polymeric cable insulation specimens. Insulation specimens were aged at 121 °C, 136 °C, 150 °C, and 165 °C and a 10% ?E*ab difference between the specimen edge and specimen center was used as the threshold for DLO. Based on these specifications DLO was observed in EPR insulation specimen at temperatures of 136 °C and above, with an increasing degree of DLO observed as the time of exposure increased. The method presented in this work represents a quantitative and high-throughput method for the investigation of DLO with a low cost barrier for entry.

diffusion limited oxidation, DLO, nuclear, electri↗

Investigation of Inverse Temperature Effects During Thermal-Radiation Aging of Semicrystalline Cable Insulation

Inverse temperature effects were observed for semi-crystalline polymers subjected to combined thermal and irradiation aging. The mechanical durability of materials aged at low temperatures degrades with dose faster than at high temperatures. In this paper, two crosslinked polyethylene (XLPE) and two ethylene propylene rubber (EPR) type nuclear cable insulations were exposed to thermal-radiation aging at 100Gy/h up to 30Mrad and three temperatures (26°C, 50°C, 90°C). Their mass change and color change after aging were analyzed.

Ni, Yelin↗

Mechanical and Chemical Properties of Harvested Hypalon Cable Jacket Subjected to Accelerated Thermal Aging

For nuclear power plants (NPPs) that are considering second license renewal for their operation beyond 60 years, knowledge of long-term operation, condition monitoring, and viability for the reactor components including reactor pressure vessel, concrete structures, and cable systems is essential. Such knowledge will provide NPPs with a game plan to predict performance and to estimate costs that are associated with monitoring or replacement programs for the affected systems. For cable systems that encompass a wide variety of materials, manufacturers, and in-plant location, accelerated aging of harvested cable jacket and insulation can provide insight as to remaining useful life and methods for monitoring. Accelerated thermal aging in air at temperatures between 80°C and 120°C was carried out on a multi-conductor control rod cable that had been in-service for over 30 years and was made by Boston Insulated Wire with Hypalon cable jacket and ethylene-propylene rubber insulation. From elongation at break (EAB) measurements and supporting Arrhenius analysis of the jacket material, an activation energy of 97.84 kJ/mol was estimated and the time to degradation, as represented by 50% EAB at the expected maximum operating temperature of 45°C, was estimated as consistent with 80 years. These values were slightly below previous measurements and could either be attributed to in-service degradation or variations in material properties from a given manufacturer. In addition, results from indenter modulus measurements and Fourier transform infrared spectroscopy suggest possible markers that could be beneficial to monitor cable conditions.

cable aging, cable insulation, Hypalon, second lic↗

Tracking Aging in Nuclear Electrical Cable Polymers

The electrical cable network is the nerve center of a nuclear plant, providing power, instrumentation and control of critical systems during operation, planned outage, and during design basis, unplanned outage events. It is therefore important to manage cable system health through awareness of local environments adverse to cable longevity, monitoring of cable condition, and predictive understanding of cable degradation [1-3]. Nondestructive methods can be used to assess the condition of the full length of installed cables and of localized cable regions to support cable repair and replacement planning decisions [4-5]. Informed knowledge of the effects of environment on cable performance over time combined with cable state assessment data can minimize costs associated with cable management by both avoiding outages and ramifications from unexpected cable failure and by avoiding premature replacement of functional cables. In this work, the aging behavior of commonly found nuclear cable insulation and jacketing materials is investigated along with established and emerging methods for locating and quantifying cable degradation. Ethylene-propylene rubber (EPR) and chlorinated polyethylene (CPE), examples of prevalent insulation and jacket materials used in nuclear power plants (NPPs), are thermally aged at elevated temperature to induced material changes similar to those experienced by cable material under long term service conditions. Destructive and nondestructive laboratory tests are used to follow changes in the materials with aging toward establishing predictive capabilities to help extend the life of installed nuclear cables and reduce cable management operational costs.

Cable aging, EPR, CPE, NDE, nuclear↗

Development of an In-Situ Method for Cable Condition Monitoring in Nuclear Power Plants (SBIR Phase IIB Final Report)

This is the final report of a Small Business Innovation Research (SBIR) project that Analysis and Measurement Services Corporation (AMS) has conducted for the U.S. Department of Energy (DOE) over a seven-and-a-half year period (February 2013 through April 2020 with the awards of Phase I, Phase II and Phase IIB projects). The goal of the project was to design, develop, validate, and demonstrate a technique for in-situ testing of cable insulation polymers that will identify, locate, and provide the degree of aging for cables commonly used in nuclear power plants. During the Phase I project, AMS established that the frequency domain reflectometry (FDR) technique can successfully identify and measure cable insulation degradation that can be trended with aging. In Phase II, AMS performed extensive cable aging studies to correlate FDR measurements with other laboratory condition monitoring techniques and developed aging condition categories to quantify the severity of insulation degradation. In Phase IIB, the project expanded the research to include a wider variety of cable polymers that are used in the commercial nuclear power industry. This work also involved developing acceptance criteria to objectively assess age-related cable degradation while sharing the results of this research with industry, academia, and national laboratories to advance the state of the art in cable aging management technologies. The products developed under this research project provide the nuclear industry with an effective condition monitoring tool to support safe and long-term plant operation. Throughout the project, collaborations and support were received from a variety of industry organizations and individuals including DOE National Laboratories as well as nuclear plant utilities and several other industry experts and cable manufacturers. Contributions from these organizations included the donation of new cables, naturally aged cables, and research collaboration. The validation and commercialization of the products of this project were achieved through opportunities to test and demonstrate the technologies’ capabilities on-site at nuclear power generation and research facilities as well as in the laboratory alongside industry peers and cable testing service companies. The research resulted in a technology that can be used to identify, locate, and quantify age-related degradation in several types of cable polymers. This included developing software and hardware as well as the methodology for using the FDR technique to assess age-related degradation of installed cables. The technology developed under this project can provide nuclear plant management, engineers, and technicians with an in-situ electrical test method to determine if in-service cables need to be replaced, monitored on a periodic basis, or show no evidence of significant age-related degradation that may require action. Near the end of this Phase IIB project, the FDR product was sold to a nuclear power utility in South Korea. This sale of a dedicated aging assessment tool is the beginning of a comprehensive contract with the expectation of twelve (12) units sold to that country. Additionally, the FDR technology has been sold to several industry organizations including a nuclear research institute and the Diablo Canyon nuclear power plant. This technology is also being leased by other nuclear industry service companies for incorporation into aging management programs. The cable testing technology that was developed under this project was also integrated into a comprehensive cable aging assessment service that is being offered to the nuclear industry at the request of U.S. nuclear utilities and is currently part of onsite testing services provided by AMS.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Impact of CSPE Jackets on Accelerated Aging of Harvested Cable Insulations in Support of Remaining Useful Life Assessments

Nuclear power plants (NPPs) are operating beyond their original 40-year operating lifetime, with more than 80% operating on the first license renewal for an extended 20-years. To sustain the effective and cost-effective operation of their electrical cables, understanding cable material performance in current and future environments can lead to effective maintenance strategies and condition monitoring protocols. Addressing the issue of long-term operation and viability, accelerated aging was carried out on chlorosulfonated polyethylene (CSPE) / ethylene propylene rubber (EPR) insulations that were removed from harvested electrical cables. Cables were obtained as part of the Light Water Reactor and Sustainability (LWRS) Zion Harvesting Project in cooperation with Energy Solutions and the U.S. NRC. Zion NPP was in operation for 25 years prior to decommissioning before its 40-year operation license had expired.For the Boston Insulated Wire (BIW) manufactured EPR insulation with outer CSPE jackets, degradation was observed in mechanical properties with respect to time and temperature was observed. This degradation was impacted by the outer CSPE jacket as the increase in to the time to degradation at the same temperature was observed for EPR insulations with the outer CSPE jacket removed prior to aging. The correlation of IM and density to EAB also suggested that these parameters could also be used effectively in the estimates of activation energy with additional data. Arrhenius analysis on the mechanical degradation as measured by EAB for the two types of BIW EPR insulations with outer CSPE jackets estimated activation energies slightly different (BIW-A without outer CSPE jacket 1.58 eV, BIW-B with outer CSPE jacket 1.10 eV) than the 1.24 eV found in from analysis of EAB data found in Zion NPP BIW insulation documentation. These values were higher than those previously reported of 0.90 eV to 0.96 eV for CSPE and EPR materials in the literature and additional measurements are needed to further validate the increase in activation energy for these harvested materials and possible impact on remaining useful life estimation. Finally, FTIR analysis showed differences in the oxidation as measured by decrease in C-H bonds in EPR insulation and CSPE jackets and increase in C-O bonds in certain cases.

Davis, Sarah M.↗

Survey of Aging and Monitoring Concerns for Cables and Splices Due to Cable Repair and Replacement

The purpose of this report is to survey aging and monitoring concerns for electrical cable splices in nuclear power plants (NPPs) in long term operation. As portions of existing electrical cable runs in nuclear are replaced over time due to localized events, the total number of splices in NPPs is expected to increase. Relative to cables, the body of knowledge regarding aging of splices and splices in combination with aging cables in nuclear service environments in long-term operations is low. A few reports have considered the aging of cable system components other than cables (Jacobus 1990; Nelson 1998; Villaran and Lofaro 2002), but the nuclear industry has two decades of operating experience since these were published to further enlighten this issue. Herein we discuss electrical cables and splices commonly found in U.S. nuclear power plants, their qualification in safety-related application, and methods for monitoring their health condition. Common environmental stresses that can give rise to cable and splice failure are discussed. The Nuclear Regulatory Commission (NRC) Licensee Event Reports (LER) database was used to identify documented issues of cable and splice failure. The trend in the resultant data over time is considered to see if failures are increasing as plants age. Observations and conclusions of this work include: 1. Cables and splices are highly reliable components. Occurrence rates for events of interest were low and nearly constant over the last 20 years. 2. Common-cause failure for evaluated cable events of interest was observed to primarily be associated with loose connections, which may manifest associated with workmanship issues, thermal cycling, and/or vibration. 3. Replacement of cables is more common than repair, leading to an increase in proportion of new generation cables in the plant over time. 4. Splices on degraded cables have been observed to be problematic. Due to aging NPP infrastructure, including electrical cables, it is expected that such issues will continue to increase. 5. Condition monitoring approaches, while shown to be fruitful for cables, have been shown to be insensitive to degradation of splice sleeves, which are critical to the continued performance of splices. Additional condition monitoring (CM) work is needed to evaluate methods which are sensitive to the degradation of splice components. 6. Extended Material Degradation Assessment (EMDA) knowledge gaps for electrical cables (Bernstein et al. 2014) have not been investigated for splices but may represent similar concerns such as for the accelerated aging process historically used in environmental qualification.

42 ENGINEERING↗

Application of Principal Component Analysis for the Monitoring of the Aging Process of Nuclear Electrical Cable Insulation

To ensure the safe operation of nuclear power plants (NPPs), it is critical to understand how NPP electrical cable insulation will degrade under different service environments. In this study, various nondestructive examination methods were selected to evaluate degradation of electrical cable insulation after aging. Elongation at break, indenter modulus, relaxation constant, mass change, total color difference, and carbonyl index were collected stepwise on cross-linked polyethylene (XLPE) cable insulations after predetermined exposure intervals. Three different insulation aging scenarios were investigated: 1) simultaneous irradiation and heating at 150°C, 2) heating at 150°C followed by corresponding times of irradiation at ambient temperature, and 3) irradiation at ambient temperature followed by heating at 150°C for the same duration. A constant dose rate of 300 Gy/hr was selected with a total gamma irradiation absorbed dose up to 320 kGy. To gain insight into the long-term performance of NPP electrical cable insulation, principal component analysis (PCA), a data-driven approach, was utilized to identify key indicators of cable insulation degradation. By reducing the dimensionality of the data while retaining degradation information, PCA was used to highlight the changes in the measured properties under gamma irradiation according to total absorbed dose and the different aging scenarios.

Li, Donghui↗

Consideration of Decabromodiphenyl Ether Flame Retardant in Thermal and Radiation Aging of Crosslinked Polyethylene Cable Insulation

Decabromodiphenyl ether (decaBDE) has been used as a flame-retardant additive in nuclear-grade electrical cable insulation. However, decaBDE has been identified as a persistent, bioaccumulative and toxic (PBT) substance, leading to regulatory scrutiny. On January 6, 2021, the Environmental Protection Agency (EPA) published a final rule to phase out decaBDE. The 2021 rule set a two-year compliance deadline for “processing and distribution in commerce of decaBDE for use in wire and cable insulation in nuclear power generation facilities.” In recognition of industry concerns following a sudden discontinuation of decaBDE-containing Class 1E wire and cable essential for nuclear power operations and the time needed for qualifying the individual components using the alternative insulation technology, an extended compliance deadline was set in the finalized amendments to the 2021 rule as published by the Environmental Appeals Board on November 12, 2024. The 2024 rule set the compliance deadline for processing and distributing decaBDE-containing wire and cable insulation until the end of the service life of these materials. Since decaBDE has long been relied upon as the flame retardant in one of the most common cross-linked polyethylene (XLPE) nuclear cable insulation formulations, RSCC Firewall III insulation, questions have naturally arisen regarding whether changes in cable performance might be expected for XLPE containing a decaBDE alternative, especially for safety-related cables that must perform their safety function in a design basis event such as a loss of coolant accident.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sequential versus Simultaneous Aging of XLPE Nuclear Cable Insulation Subjected to Elevated Temperature and Gamma Radiation

Electrical cables constitute a critical component of nuclear power generation. The aging behavior of electrical cable insulation under combined exposure to thermal and radiation stress is not additive, complicating lifetime prediction of cable performance based on sequential accelerated aging. In this work we explore the relative effects of simultaneous and sequential thermal and gamma radiation aging on cross-linked polyethylene (XLPE), which is commonly found in commercial nuclear power plants in the United States. Samples of XLPE were subjected to up to 320 kGy of gamma irradiation at a dose rate of 300 Gy/hr in two heating scenarios. In the first, simultaneously-aged samples were heated at 150°C during irradiation. In the second, sequentially aged samples were heated at 150°C for designated durations followed by corresponding periods of irradiation without heating. The mass, total color difference, and density were characterized to quantify aging of the insulation polymer. Sequential aging is hypothesized to be more damaging to XLPE insulation due to an increased trend in mass gain, total color difference, and density.

Cross-linked polyethylene, XLPE, nuclear cable, ac↗

Accelerated Aging of PV Cables - The Development of Methods Towards Combined-Accelerated Stress Testing

PV cables allow the collection and distribution of electricity from modules to the energy grid. Durable cabling allows continuous operation of PV installations. Cables with a life less than that of the modules must be replaced - reducing electricity generation and adding to the system operating expense. We have examined the durability of a variety of representative cable samples using artificial UV weathering (IEC TS 62788-7-2) and combined accelerated stress testing (C-AST). Jackets in this study include PV-rated (polyolefin), building wire (PVC/PA), and multi-conductor (rubber, as in PV trackers), with some examples of black and red cables. Characterizations at read points include appearance (camera and optical microscope), surface roughness (linear profilometry), instrumented indentation, surface morphology (SEM), chemical composition (EDS), thermal decomposition (TGA), phase transition (DSC), crystalline structure (WAXS), and polymer chemical structure (FTIR). Complimentary examinations confirm damage to the external and interior layer(s) of less durable samples, including changes in morphology (e.g., cracking), chemistry (e.g., oxidation), structure, and mechanical performance (e.g., through-thickness modulus and hardness). The results may be generally compared to other examples from the field (PV installations) or after accelerated testing (IEC 61215). The methods in this study are presently being applied in a follow-on C-AST study, incorporating both dynamic and kinematic fixtures.

balance of systems↗

Insight into Thermal Aging of Jacket-bonded Ethylene-propylene Rubber Cable Insulation

Electrical cables are integral to nuclear power plant operation and control during power generation, during planned outages, and during design basis events. Polymeric insulation and jacketing used in cable construction does age over time as a function of environmental stresses including heat, moisture, and radiation. Degradation of polymer mechanical properties can lead to breaks in the insulation and consequent electrical shorting. In this work we consider the thermal aging behavior of one of the two most common insulation polymer classes in nuclear power plants, ethylene-propylene rubber (EPR), both as an independent material and within a cable in which the EPR is bonded to a chlorinated polyethylene (CPE) jacket. Understanding the changes in these two materials with aging, both independently and in concert, will allow the establishment of aging lifetime curves and enable the development of effective non-destructive methods for tracking the condition of installed cables composed of similar material systems. Additional and more effective methods for monitoring the condition of installed cables are needed as a technical basis for continued safe use of aging cables in long term operation and to minimize operating costs for cable aging management through better informed retain/repair/replace decisions.

Light Water Reactors, electrical cables, aging, EP↗

Detection of diffusion limited oxidation in thermally aged ethylene propylene rubber cable insulation material

The lifetime prediction of electrical cable insulation in nuclear power plants (NPPs) is primarily based on accelerated aging. Polymeric insulation exposed to accelerated aging at high temperatures may demonstrate diffusion limited oxidation (DLO) where oxygen within the material is consumed faster than can be supplied by diffusion from the surrounding air. This situation leads to equilibrium oxidation at the exposed surfaces and limited oxidation away from the surfaces. Therefore, DLO results in a heterogeneously aged material which can lead to underestimation of lifetime for in-service cable insulation. In this study, the presence of inhomogeneous aging caused by DLO was evaluated on cross-sectioned cable insulation specimens made of ethylene propylene rubber (EPR). The studies were performed on thermally aged specimens (165 °C, 1 day and 165 °C, 16 days) using local measurement techniques including nanoindentation, micro-Fourier transform infrared spectroscopy (FTIR), and scanning electron microscopy (SEM) - energy dispersive spectroscopy (EDS). All the results indicate some degree of heterogenous aging, with 165 °C, 16 days, aging demonstrating highest degree of oxidative degradation on the inside edges presumably caused due to copper catalyzed oxidation.

Pallaka, Madhusudhan Reddy↗