Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration and fitting methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Mobile VLBI and GPS measurement of vertical crustal motion

Mobile Very Long Base Interferometry (VLBI) and Global Positioning System (GPS) geodetic measurements have many error sources in common. Calibration of the effects of water vapor on signal transmission through the atmosphere, however, remains the primary limitation to the accuracy of vertical crustal motion measurements made by either technique. The two primary methods of water vapor calibration currently in use for mobile VLBI baseline measurements were evaluated: radiometric measurements of the sky brightness near the 22 GHz emission line of free water molecules and surface meteorological measurements used as input to an atmospheric model. Based upon a limited set of 9 baselines, it is shown that calibrating VLBI data with water vapor radiometer measurements provides a significantly better fit to the theoretical decay model than calibrating the same data with surface meteorological measurements. The effect of estimating a systematic error in the surface meteorological calibration is shown to improve the consistency of the vertical baseline components obtained by the two calibration methods. A detailed error model for the vertical baseline components obtained indicates current mobile VLBI technology should allow accuracies of order 3 cm with WVR calibration and 10 cm when surface meteorological calibration is used.

Kroger, P. M.↗

Mobile very long baseline interferometry and Global Positioning System measurement of vertical crustal motion

Mobile Very Long Base Interferometry (VLBI) and Global Positioning System (GPS) geodetic measurements have many error sources in common. Calibration of the effects of water vapor on signal transmission through the atmosphere, however, remains the primary limitation to the accuracy of vertical crustal motion measurements made by either technique. The two primary methods of water vapor calibration currently in use for mobile VLBI baseline measurements were evaluated: radiometric measurements of the sky brightness near the 22 GHz emission line of free water molecules and surface meteorological measurements used as input to an atmospheric model. Based upon a limited set of 9 baselines, it is shown that calibrating VLBI data with water vapor radiometer measurements provides a significantly better fit to the theoretical decay model than calibrating the same data with surface meteorological measurements. The effect of estimating a systematic error in the surface meteorological calibration is shown to improve the consistency of the vertical baseline components obtained by the two calibration methods. A detailed error model for the vertical baseline components obtained indicates current mobile VLBI technology should allow accuracies of order 3 cm with WVR calibration and 10 cm when surface meteorological calibration is used.

Kroger, Peter M.↗

Increased accuracy and signal-to-noise ratio through recent improvements in infra-red video bolometer fabrication and calibration

The infra-red video bolometer (IRVB) is a diagnostic equipped with an infra-red camera that measures the total radiated power in thousands of lines of sight within a large field of view. Recently validated in MAST-U [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)], it offers a high spatial resolution map of the radiated power in the divertor region, where large gradients are expected. The IRVB’s sensing element comprises a thin layer of high Z absorbing material, typically platinum, usually coated with carbon to reduce reflections [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)].Here, the possibility of using a relatively inert material such as titanium, is explored that can be produced in layers up to 1 μm compared to 2.5 μm for Pt and then coat it with Pt of the desired thickness (0.3 μm per side here) and carbon. This leads to a higher temperature signal (about 3 times) and better spatial resolution (about 4 times), resulting in higher accuracy in the measured power [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)]. This assembly is also expected to improve foil uniformity, as the Pt layer is obtained via deposition rather than mechanical processes [Mukai et al., Rev. Sci. Instrum. 87, 2014 (2016)].Given its multi-material composition, measuring the thermal properties of the foil assembly is vital. Various methods using a calibrated laser as a heat source have been developed, analyzing the temperature profile shape [Sano et al., Plasma and Fusion Res. 7, 2405039 (2012)] and [Mukai et al., Rev. Sci. Instrum. 89, 10E114 (2018)] or fitting the calculated laser power for different intensities and frequencies [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)]. Here, a simpler approach is presented, which relies on analyzing the separate components of the foil heat equation for a single laser exposure in a given area. This can then be iterated over the entire foil to capture local deviations.

Magnetic Fusion Energy↗

A proposed high-intensity radiometer calibration method using concentrated solar radiation

Accurate calibration of irradiance measurement devices, or radiometers, is essential for ensuring the reliability of measurements in high heat applications such as concentrating solar power (CSP), aerospace, defense, and pulsed power systems. Despite the critical need, existing calibration standards and service providers are limited to irradiance levels below 100 kW/m 2 and specific radiation sources, which is insufficient for many applications. For instance, CSP technologies, particularly those under the Department of Energy’s Solar Energy Technologies Office (SETO) Gen 3 program, require accurate measurements of broadband irradiance at levels exceeding 2000 kW/m 2 . In even more extreme scenarios, such as re-entry vehicles, heat levels can surpass 10000 kW/m 2 . Current ISO standards, specifically ISO 14934–2 and ISO 14934–3, are constrained to lower irradiance levels and dependent on black body heat sources, limiting their applicability for high-intensity broadband irradiance measurements, particularly in concentrated solar applications. Here, to address this shortfall, the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (SNL) proposes a calibration method and facility capable of characterizing radiometers up to 2750 kW/m 2 using concentrated solar irradiance. Calibrating with concentrated sunlight is important for solar applications as it aligns the calibration process with the solar spectrum. This alignment is crucial for minimizing systematic errors and avoiding the need for additional corrections that may arise when radiometers designed for solar applications are calibrated using black-body or electrical sources. This paper presents the present day NSTTF characterization facility and procedure, detailing the proposed calibration method and uncertainty quantification. The presented method builds upon 1980′s NSTTF methodology and involves both theoretical and empirical methods to establish a robust relationship between gauge voltage output and irradiance intensity, quantifying both measurement and fitting errors. By addressing the limitations of existing standards and extending the characterization range, this work provides an advancement in the field of high-intensity irradiance measurement and instrumentation characterization.

Gardon gauge↗

Analytical gradient-based optimization of CALPHAD model parameters

The calibration of CALPHAD (CALculation of PHAse Diagrams) models involves the solution of a very challenging high-dimensional multiobjective optimization problem. Traditional approaches to parameter fitting predominantly rely on gradient-free methods, which while robust, are computationally inefficient and often scale poorly with model complexity. In this work, we introduce and demonstrate a generalizable framework for analytic gradient-based optimization of the parameters of the CALPHAD model enabled by the recently formalized Jansson derivative technique. This method allows for efficient evaluation of gradients of thermodynamic properties at equilibrium with respect to model parameters, even in the presence of arbitrarily complex internal degrees of freedom. Leveraging these semi-analytic gradients, we employ the conjugate gradient (CG) method to optimize thermodynamic model parameters for four binary alloy systems: Cu-Mg, Fe-Ni, Cr-Ni, and Cr-Fe. Across all systems, CG achieves comparable or superior optimality relative to Bayesian ensemble Markov Chain Monte Carlo (MCMC) with improvements in computational efficiency ranging from one to three orders of magnitude. Furthermore, our results establish a new paradigm for CALPHAD assessments in which high fidelity data-rich model calibration becomes tractable using deterministic gradient-informed algorithms.

CALPHAD↗

Design and Calibration of the X-33 Flush Airdata Sensing (FADS) System

This paper presents the design of the X-33 Flush Airdata Sensing (FADS) system. The X-33 FADS uses a matrix of pressure orifices on the vehicle nose to estimate airdata parameters. The system is designed with dual-redundant measurement hardware, which produces two independent measurement paths. Airdata parameters that correspond to the measurement path with the minimum fit error are selected as the output values. This method enables a single sensor failure to occur with minimal degrading of the system performance. The paper shows the X-33 FADS architecture, derives the estimating algorithms, and demonstrates a mathematical analysis of the FADS system stability. Preliminary aerodynamic calibrations are also presented here. The calibration parameters, the position error coefficient (epsilon), and flow correction terms for the angle of attack (delta alpha), and angle of sideslip (delta beta) are derived from wind tunnel data. Statistical accuracy of' the calibration is evaluated by comparing the wind tunnel reference conditions to the airdata parameters estimated. This comparison is accomplished by applying the calibrated FADS algorithm to the sensed wind tunnel pressures. When the resulting accuracy estimates are compared to accuracy requirements for the X-33 airdata, the FADS system meets these requirements.

Whitmore, Stephen A.↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Marine Hydrokinetic Tidal Turbine

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset is part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with other energy technologies. This dataset contains inputs and outputs from simulations of a floating marine hydrokinetic turbine over approximately half a tidal cycle (~6.6 hours). Inflow conditions were derived from field measurements in Alaska’s Cook Inlet and represent a tidal environment in which the current speed ramps from near 0 m/s to a peak of 3 m/s and back. The original acoustic doppler current profiler dataset is publicly available on the Marine and Hydrokinetic Data Repository. In a full tidal cycle, the flow reverses and the rotor would reorient; this reversal was not modeled. In the Cook Inlet campaign , turbulence intensity was similar in both directions. Two inflow cases are included. In the first case, labeled “raw” in the files, the measured current time series was used directly in the InflowWind module of OpenFAST. Speed and direction were applied as a function of time and elevation, uniformly in the horizontal direction. With full spatial coherence, this approach captures high turbulent variability and results in pronounced power fluctuations, so it is considered a conservative, near-worst-case representation of loading. In the second case, labeled “average” in the files, a 30-minute moving average was applied to extract the slowly varying mean speed. The residual fluctuations about this mean were used to generate spatially varying, full-field turbulence inputs with TurbSim, giving a more physically realistic representation of the inflow across the rotor disk. Two random realizations were used to produce distinct inflow conditions for two OpenFAST simulations representing a two-turbine array. The same turbulence intensity is applied across the full time series, producing larger fluctuations at the start and end, where the mean speed is low. The second case is the more appropriate framework for performance and power assessment but overpredicts turbulence at lower flow speeds and underpredicts it at higher speeds. As the floating platform moves and the rotor changes its x-position, Taylor’s frozen turbulence hypothesis used by InflowWind assumes a constant rather than a time-varying mean velocity, introducing some inaccuracy in the velocity plane sampling. The turbine modeled is the 500-kW Reference Model 1, a horizontal-axis two-bladed hydrokinetic turbine on a four-column floating semisubmersible substructure . Simulations were performed using OpenFAST v4.1 with the Reference Open Source Controller (ROSCO) v2.10. All input files required to reproduce the simulations are included. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel . This unit supports up to 2.5 MW, but NLR has only a single 1.25-MW stack. The datasets report hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. The system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operating current of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The simulated tidal turbine time series data was translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz. Each zip file represents a single tidal electrolysis experiment and is named: {technology}_{inflow method}_{number of 500 kW tidal turbines connected} For instance, “tidal-500kW-RM1_average_2.zip” is a 6-hour experiment using the 500-kW tidal reference model, scaled by 2x (1-MW) to better match the electrolyzer maximum of 1.25MW, fed with the 30-minute moving average current case. Each zip folder contains the following files: A .csv file of raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. A .csv file combines all tidal profiles as "combined_tidal_experiments.csv." A separate experiment, “characterization_200.zip,” shows the MC250 electrolyzer steady-state response with 30-minute load steps over 5 hours and is accessible with this entry.

08 HYDROGEN↗

An airborne study of microwave surface sensing and boundary layer heat and moisture fluxes for Project FIFE

This is the third semiannual status report describing the University of Wyoming participation in project FIFE, under NASA Grant NAG 5-913. The reader is referred to the first and second semiannual status reports for this grant for descriptions of University of Wyoming participation in the field operations of 1987. This report is concerned with continuing analysis of field data. Most of the instrument calibration effort has concentrated on interpretation and use of the high-rate water vapor measurements with the University of Wyoming Lyman-alpha device. In addition, fluxes of water vapor have been corrected for sensible heat flux, and all the high-rate (10 Hz for the Wyoming King Air) data have been filtered before the flux calculations. For each flight the Lyman-alpha data (10 Hz) are calibrated against the Cambridge dew-point hygrometer (1 Hz), by using data from the take-off sounding. The reasoning here is that the takeoff sounding (held to 500 fpm rate-of-climb specifically for the calibration) covers the widest range of humidity conditions of any sequence of the flight. For each takeoff sounding, then, the Lyman-alpha data, averaged to 1 Hz, are matched to the dewpoint data with a second-order least-squares fit. The resulting quadratic equation is then used in all subsequent analyses to convert the Lyman-alpha voltages to vapor desities for that specific flight. An alternative method is to use the range of fluctuation for the same two devices from horizontal passes to establish the calibration function. However, since the Lyman-alpha data are used only in the flux calculations, i.e., only the fluctuation and not the absolute values are used, this method is thought unnecessary.

Kelly, Robert D.↗

Strong Lensing Cosmology with Population-level Calibrated Neural Ratio Estimation

Strong gravitational lensing contains key information about cosmic acceleration. Modern and next-generation galaxy imaging surveys are expected to provide high-quality data on $\mathcal{O}(10^5)$ galaxy-galaxy lensing systems. The plethora and complexity of the data are likely to present computational challenges for parameter inference methods for fitting high-dimensional likelihoods, which are often analytically intractable. Neural Ratio Estimation (NRE) efficiently computes individual likelihood ratios that can be combined into population-level posteriors. We use simulations to study the capacity of NRE to jointly predict the dark energy equation-of-state parameter $w$ and the total matter density $Ω_{m}$ from lensing images and companion spectroscopic information. We also introduce a post hoc posterior coverage calibration procedure that mitigates the model overconfidence that is typically found in neural density estimation applications. Our experiments show that the errors on both parameters decrease with increasing inference population sizes. In particular, for 100 lenses in a standard $Λ$CDM Universe, our calibrated NRE model achieves median fractional uncertainty of $22.8\%$ in $w$ and $2.9\%$ in $Ω_{m}$. This proof of concept demonstrates a potentially scalable approach for efficient cosmological parameter inference with large populations of galaxy-scale lenses observed in future surveys.

Jarugula, Sreevani [Fermilab] (ORCID:0000000253867↗

Wind Tunnel Strain-Gage Balance Calibration Data Analysis Using a Weighted Least Squares Approach

A new approach is presented that uses a weighted least squares fit to analyze wind tunnel strain-gage balance calibration data. The weighted least squares fit is specifically designed to increase the influence of single-component loadings during the regression analysis. The weighted least squares fit also reduces the impact of calibration load schedule asymmetries on the predicted primary sensitivities of the balance gages. A weighting factor between zero and one is assigned to each calibration data point that depends on a simple count of its intentionally loaded load components or gages. The greater the number of a data point's intentionally loaded load components or gages is, the smaller its weighting factor becomes. The proposed approach is applicable to both the Iterative and Non-Iterative Methods that are used for the analysis of strain-gage balance calibration data in the aerospace testing community. The Iterative Method uses a reasonable estimate of the tare corrected load set as input for the determination of the weighting factors. The Non-Iterative Method, on the other hand, uses gage output differences relative to the natural zeros as input for the determination of the weighting factors. Machine calibration data of a six-component force balance is used to illustrate benefits of the proposed weighted least squares fit. In addition, a detailed derivation of the PRESS residuals associated with a weighted least squares fit is given in the appendices of the paper as this information could not be found in the literature. These PRESS residuals may be needed to evaluate the predictive capabilities of the final regression models that result from a weighted least squares fit of the balance calibration data.

calibration analysis↗

An IUE survey of activity in red giants and supergiants

Chromospheric and transition region line activity is examined in apparently single red giants and supergiants using the IUE archives. Low-resolution, large-aperture spectra (mostly short-wavelength) were used to search for variations of emission-line fluxes in time. A series of automatic processing procedures were implemented in order to uniformly calibrate a large number of spectra, fit continua to each of them, determine the fluxes of as many as 18 emission lines, and compare them at different epochs. A method is offered to compute the overall error in the integrated flux, a critical measure of activity, independent of the observing and processing details. This processing was applied to above 120 images of 26 stars taken over a period of 7 yr (1978-1984). Four stars showed UV emission-line flux variations. Alpha Aqr, Beta Peg, and Sigma Oph showed a single enhanced-emission event in all detectable emission lines. Gamma Aql exhibited an increase in the flux level of the O I (1641 A) line in mid-1981 with no comparable change in any other lines. These four stars lie in a region of the H-R diagram in which time-dependent circumstellar absorption lines appear.

Oznovich, I.↗

XCal: model-based approach to X-ray CT spectral calibration

Transmission X-ray computed tomography (CT) is widely used to quantitatively reconstruct 3D objects composed of multiple materials. However, accurate CT reconstruction requires the system to be calibrated to account for the effective X-ray spectrum. Unfortunately, measurement of the effective spectrum is ill-posed, and existing calibration methods require that the system be recalibrated when the system parameters are changed. In this paper, we propose XCal, a multi-energy model-based spectral calibration approach for X-ray CT. The XCal approach models the effective spectrum using a separable physics-based model of the CT system. The model parameters are then estimated by fitting calibration data with known objects at multiple energies. An important advantage of XCal is that it allows the user to change scanner settings, such as the source voltage or X-ray filters, without the need for recalibration. Evaluations on simulated and measured datasets demonstrate that XCal significantly improves the accuracy of the estimated spectrum as compared to existing calibration methods.

Li, Wenrui [Purdue Univ., West Lafayette, IN (Unit↗

The Use of Absolute-Value Terms in Regression Modeling of Multi-Piece Force Balances

Different aspects of the use of absolute-value terms in regression models of the electrical outputs of multi-piece force balance calibration data are discussed. First, characteristics of a variety of regression model term combinations with absolute-value terms are reviewed that are currently used in the aerospace testing community to fit the gage outputs of a balance. Then, a semi-empirical test is presented that quantifies bidirectional characteristics of the balance bridge outputs. Several diagnostic methods are discussed to assess the severity of near-linear dependencies between regressors of models with absolute-value terms. In particular, connections between the linear, absolute-value, quadratic, signed quadratic, and cubic terms are studied in greater detail. Data from an automated calibration of NASAs MK29B force balance are used to illustrate the most important observations and results. Rules of thumb that variance-inflation factors be less than 10 must be relaxed when using absolute-value terms to describe bidirectional balances.

calibration analysis↗

Mid-Latitude Temperatures at 87 km: Results From Multi-Instrument Fourier Analysis

Using a novel Fourier fitting method we combine two years of mid-latitude temperature measurements at 87 km from the High Resolution Doppler Imager, the Colorado State University lidar, and the Peach Mountain Interferometer. After accounting for calibration bias, significant local-time variations on the order of 10 K were observed. Stationary planetary waves with amplitudes up to 10 K were observed during winter, with weaker wave amplitudes occurring during other seasons. Because of calibration biases among these instruments, we could estimate the annual mean temperature to no better than 193.5 plus or minus 8.5 K.

FOURIER ANALYSIS↗

Calibration and Data Analysis of the MC-130 Air Balance

Design, calibration, calibration analysis, and intended use of the MC-130 air balance are discussed. The MC-130 balance is an 8.0 inch diameter force balance that has two separate internal air flow systems and one external bellows system. The manual calibration of the balance consisted of a total of 1854 data points with both unpressurized and pressurized air flowing through the balance. A subset of 1160 data points was chosen for the calibration data analysis. The regression analysis of the subset was performed using two fundamentally different analysis approaches. First, the data analysis was performed using a recently developed extension of the Iterative Method. This approach fits gage outputs as a function of both applied balance loads and bellows pressures while still allowing the application of the iteration scheme that is used with the Iterative Method. Then, for comparison, the axial force was also analyzed using the Non-Iterative Method. This alternate approach directly fits loads as a function of measured gage outputs and bellows pressures and does not require a load iteration. The regression models used by both the extended Iterative and Non-Iterative Method were constructed such that they met a set of widely accepted statistical quality requirements. These requirements lead to reliable regression models and prevent overfitting of data because they ensure that no hidden near-linear dependencies between regression model terms exist and that only statistically significant terms are included. Finally, a comparison of the axial force residuals was performed. Overall, axial force estimates obtained from both methods show excellent agreement as the differences of the standard deviation of the axial force residuals are on the order of 0.001 % of the axial force capacity.

Booth, Dennis↗

On-Orbit Calibration of Redundant Spacecraft Gyros by Optimal Reduction to Three Axes

The Aqua spacecraft will carry four single-axis gyros configured with three orthogonal axes and one skew axis. This redundancy presents a challenge for batch methods of on-orbit gyro calibration that use a spacecraft rotation model deterministically related to gyro data, in that sensor data can respond to at most three angular velocity components. When the number of gyros, N, is greater than 3, the 3xN matrix, G, that reduces the N gyro measurements to three body-frame angular-velocity components cannot be fully determined by such methods; there are many such matrices that produce essentially the same angular velocity history. In such a case, spacecraft operators require information about the Nx3 gyro linear response matrix, R, that relates gyro outputs to the body-frame angular velocities causing them. This matrix provides sufficient information to determine multiple reduced-dimension G-matrices for use in case of failure or degradation of one or more gyros, as well as to determine an optimal 3xN G for the fully-functional configuration. A viable proposal is to apply a 3xN pre-filter matrix, F, to the N gyro outputs before carrying out a conventional gyro calibration procedure. The angular-velocity history emerging from conventional calibration may then be used as input data, together with the same gyro data that generated it, to fit the alignment, scale-factor, and bias parameters of each gyro axis in turn. A difficulty of such a proposal is the arbitrariness in the choice of F. Due to gyro noise, different pre-filter matrices produce different calibrations. This paper presents a method of choosing F that is based on optimizing gyro consistency in the limit of infinite weight on gyro data, as compared to sensor data. The choice of F is independent of a priori alignment and is based on the gyro data alone. The method is applicable to any N of three or more, but reduces to conventional batch-estimation methodologies when N = 3. Results of computational comparison among calibration simulations using various choices of F will be presented for the Aqua gyro configuration with N = 4.

Radomski, M. S.↗

The gas-phase mass–metallicity relation of dwarf galaxies across large-scale environments using the CAVITY parent sample

Context. The gas-phase mass–metallicity relation (MZR) of galaxies shows a noticeable break in slope and an increased scatter at low stellar masses, suggesting that the physical processes governing chemical enrichment differ between dwarf and high-mass systems. Dwarf galaxies, in particular, are highly susceptible to both internal and environmental mechanisms due to their shallow potential wells. Aims. The primary aim of this work is to assess whether a single, universal MZR can describe dwarf galaxies across diverse large-scale environments, or whether systematic environmental variations emerge. To probe these, we examine the MZR and star formation rate (SFR) of dwarf galaxies with stellar masses in the range of 8.9 < log(M ★ /M ⊙ ) < 9.5. Methods. Using optical spectra from the Sloan Digital Sky Survey, we measured the fluxes of key emission lines via the pyPipe3D full spectral fitting pipeline. Aperture-corrected fluxes, along with multiple metallicity indicators and calibrations, were used to derive the MZR and the SFR for 353, 311, and 22 dwarf galaxies located in voids, filaments, and clusters, respectively. Results. We find a systematic variation in the MZR slope, steeper in voids (0.28 ± 0.03) and progressively flatter in clusters (0.17 ± 0.08), indicating a dependence of the MZR on the large-scale environment in this mass regime. When galaxies are separated by local density, no significant differences are observed between isolated and non-isolated dwarfs in voids. Isolated dwarf galaxies in filaments also exhibit properties similar to those of their counterparts in voids. However, non-isolated filament galaxies exhibit similar MZR slopes comparable to those of cluster dwarfs and flatter slopes than their counterparts in voids. Conclusions. We report both large- and local-scale environmental dependencies in the gas-phase metallicity and in the slope of the MZR for dwarf galaxies. Consistent with the general consensus on the pre-processing of galaxies in filaments, our results indicate that the influence of the local environment becomes increasingly significant within the filamentary regions of the cosmic web, affecting the chemical enrichment and star formation activity of low-mass systems. These findings further suggest that a portion of the scatter commonly observed in the MZR of dwarf galaxies arises from environmental effects.

Bidaran, Bahar [Dpto. de Física Teórica y del Cosm↗

Strain gage selection in loads equations using a genetic algorithm

Traditionally, structural loads are measured using strain gages. A loads calibration test must be done before loads can be accurately measured. In one measurement method, a series of point loads is applied to the structure, and loads equations are derived via the least squares curve fitting algorithm using the strain gage responses to the applied point loads. However, many research structures are highly instrumented with strain gages, and the number and selection of gages used in a loads equation can be problematic. This paper presents an improved technique using a genetic algorithm to choose the strain gages used in the loads equations. Also presented are a comparison of the genetic algorithm performance with the current T-value technique and a variant known as the Best Step-down technique. Examples are shown using aerospace vehicle wings of high and low aspect ratio. In addition, a significant limitation in the current methods is revealed. The genetic algorithm arrived at a comparable or superior set of gages with significantly less human effort, and could be applied in instances when the current methods could not.

Source record↗