Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Constraints on the polarization angle oscillations of the Crab Nebula with the Simons Array and its applications to the search for axionlike particles

Here, we present a search for polarization oscillation of the Crab Nebula, also known as Tau A, at millimeter wavelengths using observations with the Simons Array, the successor experiment to POLARBEAR. We follow up on previous work by POLARBEAR using 90 GHz band data of the 2023 observing season of the Simons Array to evaluate the variability of Tau A’s polarization angle. Tau A is widely used as a polarization angle calibration source in millimeter-wave astronomy, and thus it is necessary to validate the stability. Additionally, an interesting application of the time-resolved polarimetry of Tau A is to search for axionlike particles (ALPs). We do not detect a global signal across the frequencies considered in this analysis and place a median 95% upper bound of polarization oscillation amplitude A < 0.12° over oscillation frequencies from 3.39 yr -1 to 1.50 day -1 . This constrains the ALP-photon coupling at a median 95% upper bound of g aγγ < 3.84 × 10 -12 × (m a /10 -21 eV) in the mass range from 4.4 × 10 -22 to 7.2 × 10 -20 eV, assuming the ALP constitutes all of dark matter, its field is a stochastic Gaussian field, and it is the sole source of Tau A’s polarization angle oscillation. Additionally, we do not detect signal at the frequencies where 2.5σ hints were previously reported by POLARBEAR, but we do not exclude these signals at the 95% confidence level.

Adkins, Tylor [University of California, Berkeley]↗

Measurement of neutron-proton capture in the $\mathrmSNO+ water phase

The SNO+ experiment collected data as a low-threshold water Cherenkov detector from September 2017 to July 2019. Measurements of the 2.2-MeV γ 's produced by neutron capture on hydrogen were made using an Am-Be calibration source, for which a large fraction of emitted neutrons are produced simultaneously with a 4.4-MeV γ. Analysis of the delayed coincidence between the 4.4-MeV γ and the 2.2-MeV capture γ revealed a neutron detection efficiency that is centered around 50% and varies at the level of 1% across the inner region of the detector, which to our knowledge is the highest efficiency achieved among pure water Cherenkov detectors. Finally, in addition, the neutron capture time constant was measured and converted to a thermal neutron-proton capture cross section of $336.3^{+1.2}_{-1.5}$ mb .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ka-Band ARM Zenith Radar (KAZR) Active Remote Sensing of Clouds (ARSCL) CloudSat Calibration (KAZRARSCL-CLOUDSAT) (Value-Added Product Report)

The Ka-band ARM Zenith Radar Active Remote Sensing of CLouds CloudSat-aligned (KAZRARSCL-CLOUDSAT) Value-Added Product (VAP) applies satellite-based reflectivity calibrations to KAZRARSCL data sets. The Atmospheric Radiation Measurement (ARM) user facility has primarily used radar subsystem calibration monitoring to track cloud radar reflectivity drift over time, since reliable external calibration sources or other absolute references (such as corner reflectors) have historically been unavailable or impracticable. A study by Kollias et al. (2019) examined cloud reflectivity profiles observed with a well-characterized spaceborne downward-pointing millimeter cloud radar, operating as part of NASA’s CloudSat satellite mission (Tanelli et al. 2008). The Kollias team derived monthly statistical reflectivity offsets between CloudSat and the various generations of ARM cloud radars (millimeter wavelength cloud radar [MMCR], W-Band ARM Cloud Radar [WACR[, and Ka-band ARM Zenith Radar [KAZR]) for many, but not all, months at most fixed and mobile ARM sites over the period 2007-2017. These offsets, when available, are applied to the existing KAZRARSCL VAP products using the KAZRARSCL-CLOUDSAT VAP.

54 ENVIRONMENTAL SCIENCES↗

Diagnosing the DARHT Electron Beam-Target Interaction and Hydrodynamic Expansion [Dissertation]

Quantitative electron beam-target interaction studies on the Dual-Axis Radiographic Hydrodynamic Test (DARHT) electron linear induction accelerators have only been performed recently. This includes characterization of the temperature, density, pressure, extent, and expansion velocity of the plasma plume. The results presented in this dissertation present a detailed and unified overview of the accelerator systems, target heating physics, beam transport, and diagnostic tools. Additional information includes calibration sources, radiation hydrodynamics, spectroscopic-quality radiation transport modeling, experimental measurements, and analyses of electron beam driven aluminum experiments. The first set of spatially and temporally resolved spectroscopic measurements of electron beam driven aluminum are presented. Contamination quantification analyses are used to understand the origin of the strong Na-I 3p-3s lines that are observed in absorption within the aluminum plasma continuum. These results inform the creation of the first spectroscopic-quality radiation transport model that links several atomic physics codes to interpret the conditions from which the Na-I lines originate. A good agreement is found between the surface analysis results and the model which confirms the concentration of the sodium present within the aluminum alloy foil material. It also demonstrates, for the first time on electron beam-driven target experiments, the ability to interpret plasma conditions from measured absorption lines. In a second experimental campaign which focuses on pure aluminum, the Al-I 3p-4s and 3p3d doublets are both measured in emission. A detailed analysis of the Al-I 3p-4s doublet reveals that the lines undergo moderate self-absorption. A simple model of the self-absorption effect is successfully used to match measured spectra at various temperature/density/plasma scale length combinations. These measurements led to the realization of the minimum density that can be resolved by the spectrometers for the Al-I 3p-4s lines due to the large slit width required to observe a signal on aluminum. These measurements also demonstrate the sensitivity of visible and long wave UV spectroscopy to minor changes in both temperature and density. The simple self-absorption model will be useful for analysis of other beam-target interaction experiments with spectra exhibiting either self-absorption or full self-reversal. Substantial headway has been made on the modeling front by linking together several codes needed to model both the energy deposition, hydrodynamic motion, and atomic kinetics to produce synthetic spectral calculations that are compared with experimental measurements. There exists ample space for improvement, especially with benchmarking the hydrodynamics codes and equation-of-state tables with experimental measurements. The X-ray diagnostics required to make these new measurements along with the simulation capabilities required to interpret the results are under development and will be the subject of future studies.

43 PARTICLE ACCELERATORS↗

GEANT4 code for DANCE with NEUANCE detector-response simulations

A new GEANT4 model for DANCE with NEUANCE has been developed to account for the change in the DANCE configuration when NEUANCE is installed. In this model, the energy resolution and the shape of the threshold of the individual DANCE detectors are used as an input to provide realistic representation of the measured γ-ray spectra. In addition, the distance from each detector to the target is defined in an input file as well as the physical presence of the a detector in the DANCE and NEUANCE arrays. The azimuthal angle of NEUANCE is also an external parameter to be tuned to represent the measurement. Simulated spectra are compared with measurements with standard γ-ray calibrated sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Delayed Neutron Temporal Signatures for Uranium Enrichment Measurement NA-241 SGTech (Final Report)

Nondestructive determination of uranium enrichment is a core capability for nuclear material accounting and control (NMAC) and safeguards verification measurements; however, traditional gamma spectroscopy-based techniques for enrichment measurement rely on significant assumptions of material composition and geometry, precluding their use in scenarios where a heterogeneous spatial distribution of enrichments is encountered. As an alternative, we are developing a technique to use delayed neutron temporal signatures for the measurement of uranium enrichment. Each uranium isotope has unique delayed neutron group yields, resulting in a unique delayed neutron decay time profile which can be analyzed to determine enrichment without the need for calibration sources. As part of this effort, we performed a series of measurement campaigns in which we used an active well coincidence counter (AWCC) retrofitted with commercial D-D and D-T generators to evaluate the operational characteristics of this method in response to a set of uranium enrichment and mass standards, as well as representative diversion scenarios in which either “concealed” enriched uranium is shielded by depleted uranium or declared enriched uranium is “hollowed out” and replaced with a central region of depleted uranium. A standard operating procedure and best practices were compiled to facilitate the use of delayed neutron-based enrichment measurements for international safeguards inspections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma and Neutron Measurement and Modeling of Irradiated TRISO Fuel

Given the unique characteristics of the PBR fuel cycle, both gamma and neutron measurements are expected to play important roles in performing and maintaining nuclear material control and accounting for spent pebbles to safeguard the fuel cycle. Given the lack of irradiated pebbles in the US, a variety of irradiated TRISO fuel samples with wide ranges of burnups and cooling times available at ORNL were used in this work. A large number of gamma and neutron measurements have been performed on these samples to collect data to test the various detectors and to benchmark the computer models to simulate the depletion and decay of the fuel and the measurements themselves. Two neutron detectors, including a custom-made detector and the Very High-Performance Neutron Multiplicity Counting, were used to measure the neutrons emitted by these TRISO samples. Three gamma spectrometry detectors, including an HPGe and the M400 CZT detector, were used to measure gamma-ray emissions from these samples. The M400 was recently adopted by the IAEA for fresh uranium measurements, but it was tested for spent fuel measurements prior to this project. Detailed MCNP models were developed to simulate these neutron and gamma measurements. Some GADRAS models were also developed to cross check the MCNP models for the gamma measurements. It was found challenging to perform neutron measurements in the hot cell due to the high background counts. Close agreements were observed between the simulated and measured neutron count rates in both detectors’ measurements of californium calibration sources. Both the HPGe and M400 detectors were able to measure the 604 and 662 keV peaks from these samples, which are the two most important peaks used to infer fuel burnup. Although the M400 detector did not have nearly good energy resolution and did not detect some of the minor peaks as the HPGe detector, it was found to be capable of handling significantly higher dose rates than HPGe. Given the complexities in the TRISO samples (e.g., different samples sizes) and uncertainties in the alignments between the detector and the TRISO fuel inside the containers, large scatters were found between the peak area rates and the samples’ burnups. However, the 604/662 peak ratios were found to trend well with the samples’ burnups among most samples in both measured and simulated results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement of mean excitation energies of neutrino-relevant materials

Modern neutrino experiments require precision reconstruction of events. A crucial component of this reconstruction is the stopping power for charged particles, calculated using the Bethe equation. The main free parameter of the Bethe equation is the mean excitation energy (the "I-value"), which in most cases cannot be calculated, but must be measured for each substance. In many cases, the values are derived from very old experiments with large quoted uncertainties, or worse, small quoted uncertainties and inadequate treatment of systematics. Even if the tabulated values were reliable to the necessary degree, the I-value is affected by the phase of the substance and by chemical bonding, and only rough heuristics have been developed to convert measurements of single elements into I-values for compounds or from one phase to another. Modern neutrino experiments which need to measure an absolute energy scale, while lacking calibration sources, suffer the most from uncertainties in the I-value. DUNE is a primary example. We are performing measurements with the 400MeV Fermilab LINAC beam at the Irradiation Test Facility. We describe our efforts to measure the I-value of liquid argon, as well as those for several other materials used in past, present and potential future neutrino experiments, including water, NOvA scintillator, MINOS steel, zirconium, and molybdenum. These measurements use a set of degraders to scan the beam energy around the Bragg peak for each substance to determine the proton range. Experimental results are compared to results from Geant4 and FLUKA to determine the I-value.

Strait, Matthew L. [Fermilab] (ORCID:0000000157088↗

Long-Term Stability Metrics of Photoelectrochemical Water Splitting

Photoelectrochemical (PEC) water splitting, one of the most promising technologies for clean hydrogen generation, has drawn considerable attention over the past few decades. Achieving simultaneous highly efficient and stable unassisted PEC water splitting has been the “holy grail” in clean and renewable fuel generation. State-of-the-art photoelectrodes have shown relatively high efficiencies (∼10–20%). Still, their stability is limited due to photoelectrode chemical instability, electrolyte resistance, mass transfer issues, and an often unoptimized experimental setup. In this work, we present a framework and a set of protocols for conducting long-term stability experiments and further provide details on several critical factors such as light source calibration, choosing the right counter electrode, the configuration of the PEC cell, and photoelectrode sample preparation.

08 HYDROGEN↗

Optimization of La 2–x Sr x CuO 4 Single Crystal Film Growth via Molecular Beam Epitaxy

Atomic layer-by-layer molecular beam epitaxy (ALL-MBE) combined with ozone is one of the best methods to fabricate single-crystal thin films of complex oxides. Cuprate such as La 2-x Sr x CuO 4 (LSCO) is a representative complex-oxide high-temperature superconductor (HTS) material. Our group utilizes this method to produce high-quality single-crystal HTS films with atomically smooth surfaces and interfaces. In addition, ALL-MBE enables us to engineer multilayer heterostructures with atomic precision. This allows the fabrication of tunnel junctions, various nanostructures, and other HTS devices of interest for superconducting electronics. We have synthesized over three thousand LSCO thin films in the past two decades. These films’ structural and electronic properties have been studied and characterized by various methods. Here, we distill the extensive experience we accumulated into a step-by-step protocol to fabricate atomically perfect LSCO films. The recipe includes substrate preparation, ozone generation and distillation, source calibration, the in situ monitoring of the film synthesis, post-growth annealing, and ex situ characterization. It discloses a reproducible way to fabricate single-crystal LSCO films for basic research and HTS electronic applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ozone and aerosol size distribution measurements at the Oliktok Point, AK AMF3

Aerosol size distribution measurements at the Oliktok Point, AK AMF3 as measured by a TSI model 3082 scanning mobility particle sizer (SMPS), and ozone measurements at the Oliktok Point, AK AMF3 as measured by a 2B model 205 ozone monitor. 2B specifies a limit of detection (2&sigma;) of 2 ppb and these data were calibrated using a 2B model 306 ozone calibration source. Users of the data are asked to contact PI Pratt prior to use for consultation, discussion of co-authorship, and to ensure that the most up-to-date information is provided.

54 ENVIRONMENTAL SCIENCES↗

Image plate calibration system

A calibration system for an image plate used to detect high-energy particles produced by a radioisotope includes a casing and an image plate holder disposed at least partially inside the casing. The image plate is retained by the image plate holder inside the casing. A calibration source generates energy inside the casing to prepare the image plate for detection.

Immel, Darryl R.↗

The DECADE cosmic shear project II: photometric redshift calibration of the source galaxy sample

We present the photometric redshift characterization and calibration for the Dark Energy Camera All Data Everywhere (DECADE) weak lensing dataset: a catalog of 107 million galaxies observed by the Dark Energy Camera (DECam) in the northern Galactic cap. The redshifts are estimated from a combination of wide-field photometry, deep-field photometry with associated redshift estimates, and a transfer function between the wide field and deep field that is estimated using a source injection catalog. We construct four tomographic bins for the galaxy catalog, and estimate the redshift distribution, $n(z)$, within each one using the Self-organizing Map Photo-Z (SOMPZ) methodology. Our estimates include the contributions from sample variance, zeropoint calibration uncertainties, and redshift biases, as quantified for the deep-field dataset. The total uncertainties on the mean redshifts are $σ_{\langle}$$_z$$_{\rangle} ≈ 0.01$. The SOMPZ estimates are then compared to those from the clustering redshift method, obtained by cross-correlating our source galaxies with galaxies in spectroscopic surveys, and are shown to be consistent with each other.

Anbajagane, D. [Univ. of Chicago, IL (United State↗

Advanced Energy Scale Correction Techniques for the X-ray Transition Edge Sensors of the Athena mission

The X-ray Integral Field Unit (X-IFU) onboard the future European X-ray telescope Athena will be the first space instrument carrying an array of more than a thousand transition edge sensors. One of the key challenges of the X-IFU is the measurement of narrow X-ray atomic lines to determine velocity shifts at an unprecedented level of accuracy. For this reason, the energy scale of the instrument needs to be known with extreme accuracy, of 0.4 eV (1σ) up to 7 keV. The energy scale will be measured on the ground through a dedicated calibration campaign using fiducial X-ray sources. Though calibrated, the energy scale is extremely sensitive to the environmental conditions around the TES array, and drifts in the readout chain electronics. Uncorrected, the energy scale can naturally drift up to hundreds of eVs. Changes of the TES gain will be monitored via onboard X-ray calibration sources, and the energy scale will be corrected either per pixel, or within a small groups of pixels. Although simulations show that a 0.4 eV level can be achieved, the very high accuracy required by the X-IFU calls for experimental validation. A dedicated measurement campaign has been performed by NASA Goddard Space Flight Center to characterize the energy scale of a prototype kilo-pixel array of X-IFU-representative TESs. The analysis of the data demonstrated the ability to correct for various drifts using two fiducial lines to track the temporal gain variation. In this paper, we propose to extend this study on the same data set by investigating multi-parameter correction techniques based on both the pulse-height of the fiducial line and the prepulse baseline level, using the knowledge of the TES energy scale at reference temperature/magnetic field set points acquired on the ground. Investigations on the co-adding of pixels to perform a joint correction over pools of pixels is also explored.

79 ASTRONOMY AND ASTROPHYSICS↗

Helium metastable density determination in the COST reference source by absolutely calibrated optical emission spectroscopy

Helium metastable densities in the COST Reference Microplasma Jet are estimated for a variety of He/N2 admixtures and dissipated powers by applying a collisional-radiative model to absolutely calibrated optical emission spectroscopy measurements. This is accomplished by delineating the excitation mechanisms that result in the N2(C–B) and N2+(B–X) emission bands, the latter of which is strongly coupled to the presence of helium metastables. A number of other plasma parameters are established and discussed for each operating condition including the electron energy distribution function, reduced electric field, rate constants, and electron density. With these parameters, the reaction rates for the primary ionization pathways are also calculated, emphasizing the importance of helium metastables for discharge sustainment. Good agreement with the existing literature is found for most plasma parameters and for helium metastable densities, in particular. A clear [N2]−1 relationship between the nitrogen concentration and density of helium metastables is demonstrated, as has been identified in previous studies in analogous atmospheric pressure plasma jets. This validates the efficacy of this optical technique for determining helium metastable densities and establishes it as a viable, and in many cases, more accessible alternative to other means of quantifying helium metastables in low-temperature plasmas.

Physics↗

Mapping and imaging ionizing radiation in two and three dimensions

A two-dimensional imaging system and a two-dimensional or three-dimensional optical tomographic mapping system, each employing gas scintillation induced by ionizing radiation, i.e., radioluminescence, and corresponding methods, are disclosed. The systems may employ one or more cameras and corresponding UV filters (potentially solar blind filters) for imaging a radioluminescent scene. For two-dimensional or three-dimensional mapping, the resultant UV images are spatially registered with one another and then reconstructed to form a three-dimensional tomographic map of the ionizing radiation. The two-dimensional map is a plane of the three-dimensional map. The UV images may be spatially registered by using a reference source, optionally, a calibrated reference source allowing dosimetry calculations for the ionizing radiation. Molecular nitrogen is the primary candidate for the radioluminescent gas, though a controlled ambient in a chamber of nitric oxide, argon, krypton, or xenon may be employed. The reconstruction process employs an algebraic reconstruction technique or an Abel inversion.

Bentz, Brian Z.↗

A Technical basis for in-house calibration of 252 Cf neutron source emission rates

10CFR835 stipulates that radiation protection instruments must be calibrated at least annually. Accordingly, calibration of dose rate instruments are reliant on well-known reference fields. The neutron-free-in-air facility (NFIA) located at TA36-0214 provides such a capability for neutron remmeters. One of the reference NFIA sources, 252 Cf, must be replaced every 8-10 years due to its relatively short half-life (2.645 ± 0.008 y). In the past, each newly purchased 252 Cf source has been calibrated at NIST using the Mn-bath technique prior to shipping to LANL. However, because of COVID-19 complications, the most recently acquired 252 Cf source (FTC-CF-7167) has been stored at LANL pending approval to ship to NIST for calibration. Due to the considerable expense in transporting the source to and from NIST, this TBD was written to demonstrate that new sources can be accurately calibrated via intercomparison measurements with older NIST-calibrated 252 Cf sources. It had been previously noted that such measurements yielded emission rates that agreed very well with the official rates established by NIST

252cf↗

Calibration strategy of the PROSPECT-II detector with external and intrinsic sources

This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear security applications. P-II will expand the statistical power of the original PROSPECT (P-I) dataset by at least an order of magnitude. The new design builds upon previous P-I design and focuses on improving the detector robustness and long-term stability to enable multi-year operation at one or more sites. The new design optimizes the fiducial volume by elimination of dead space previously occupied by internal calibration channels, which in turn necessitates the external deployment. In this paper, we describe a calibration strategy for P-II. Here, the expected performance of externally deployed calibration sources is evaluated using P-I data and a well-benchmarked simulation package by varying detector segmentation configurations in the analysis. The proposed external calibration scheme delivers a compatible energy scale model and achieves comparable performance with the inclusion of an additional AmBe neutron source, in comparison to the previous internal arrangement. Most importantly, the estimated uncertainty contribution from the external energy scale calibration model meets the precision requirements of the P-II experiment.

47 OTHER INSTRUMENTATION↗