Search NASA⌕ Search

SEARCH · Search NASA

Results for “camera system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The impact of plasma dynamics on the self-magnetic-pinch diode impedance

In this study, the self-magnetic-pinch diode is being developed as an intense electron beam source for pulsed-power-driven x-ray radiography. The basic operation of this diode has long been understood in the context of pinched diodes, including the dynamic effect that the diode impedance decreases during the pulse due to electrode plasma formation and expansion. Experiments being conducted at Sandia National Laboratories' RITS-6 accelerator are helping to characterize these plasmas using time-resolved and time-integrated camera systems in the x-ray and visible. These diagnostics are analyzed in conjunction with particle-in-cell simulations of anode plasma formation and evolution. The results confirm the long-standing theory of critical-current operation with the addition of a time-dependent anode-cathode gap length. The results may suggest that anomalous impedance collapse is driven by increased plasma radial drift, leading to larger-than-average ion v r × B θ acceleration into the gap.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of an IAEA Training Course for Future U.S. Inspectors

U.S. citizens currently make up only 12% of the positions held in the IAEA’s Department of Safeguards. While the United States has maintained a high level of support for the Agency over the duration of its history, the number of American inspectors currently in the field does not reflect this level of involvement. As a result, the National Nuclear Security Administration’s Office of International Relations, as part of the Next Generation Safeguards Initiative (NGSI) mission, has tasked Idaho National Laboratory (INL) to develop a rigorous two week hands-on training program to encourage and operationally acclimatize U.S. Citizens who are interested in applying for IAEA inspector positions using IAEA authorized equipment at INL. Idaho National Laboratory is one-of-a-kind in its ability to train IAEA inspectors by including training at nuclear facilities on site and includes, for example, direct measurement of an active spent fuel storage cooling pond. This accredited course will introduce and train attendees on the major IAEA systems used in collecting nuclear safeguards data and performing safeguards inspections. Unique in the United States, these classes will give attendees direct hands-on training and will address equipment purpose, function, operating principles, application, and troubleshooting, based upon what would be expected of an IAEA Safeguards Inspector in the field and in the office. Upon completion, U.S. applicants will be better qualified to pursue a position in the IAEA Department of Safeguards Operational Divisions. In support, INL has recently established a new laboratory space to house state of the art nuclear safeguards instrumentation. Currently, equipment installed in the laboratory space includes attended systems: 3DLR (3-D Imaging Laser) for design information verification, a Digital Cerenkov Viewing Device for measurement of spent fuel, HM-5 handheld radiation detectors, quantitative neutron and gamma systems; unattended monitoring systems including: NGAM and MiniGRAND radiation systems and a DMOS camera system, and VACOSS/EOSS Optical Sealing Systems..

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Patient positioning in radiotherapy based on surface imaging using time of flight cameras

Purpose: To evaluate the patient positioning accuracy in radiotherapy using a stereo-time of flight (ToF)-camera system. Methods: A system using two ToF cameras was used to scan the surface of the patients in order to position them daily on the treatment couch. The obtained point clouds were registered to (a) detect translations applied to the table (intrafraction motion) and (b) predict the displacement to be applied in order to place the patient in its reference position (interfraction motion). The measures provided by this system were compared to the effectively applied translations. The authors analyzed 150 fractions including lung, pelvis/prostate, and head and neck cancer patients. Results: The authors obtained small absolute errors for displacement detection: 0.8 ± 0.7, 0.8 ± 0.7, and 0.7 ± 0.6 mm along the vertical, longitudinal, and lateral axes, respectively, and 0.8 ± 0.7 mm for the total norm displacement. Lung cancer patients presented the largest errors with a respective mean of 1.1 ± 0.9, 0.9 ± 0.9, and 0.8 ± 0.7 mm. Conclusions: The proposed stereo-ToF system allows for sufficient accuracy and faster patient repositioning in radiotherapy. Its capability to track the complete patient surface in real time could allow, in the future, not only for an accurate positioning but also a real time tracking of any patient intrafraction motion (translation, involuntary, and breathing).

60 APPLIED LIFE SCIENCES↗

Characterization and numerical simulation of liquid refrigerant R-134a flow emerging from a flooded evaporator tube bundle

The distribution of liquid droplets emerging from an evaporator tube bundle is characterized for refrigerant R-134a with a triangular tube arrangement with a pitch of 1.167. The purpose of this research was to improve understanding of the droplet ejection process to aid in design of evaporators typically used in larger chiller systems. A laser and camera system captured images of the evaporator headspace at varying conditions. Conventional shadowgraphy techniques were applied to recognize and match droplets for velocity calculations. The evaporator conditions varied with bundle mass fluxes of 20.3 and 40.7 kg s -1 m -2 , top-rows heat fluxes of 15.8 and 31.5 kWm -2 , and outlet saturation temperatures of 4.4 and 12.8 °C. Conditions ranged from flooded to dryout of the top rows. Droplet number, size distribution, velocity, and liquid volume fraction are presented in the headspace above the bundle. A method to numerically duplicate the droplet loading in the headspace using CFD with a Lagrangian discrete-phase model is also presented and verified, providing a powerful design tool. Liquid distribution in the headspace is found to be a strong function of all varied properties, particularly mass flux, liquid level, and saturation temperature

42 ENGINEERING↗

Spectroscopic imaging of limiter heat and particle fluxes and the resulting impurity sources during Wendelstein 7-X startup plasmas

A combined IR and visible camera system [G. A. Wurden et al., “A high resolution IR/visible imaging system for the W7-X limiter,” Rev. Sci. Instrum. (these proceedings)] and a filterscope system [R. J. Colchin et al., Rev. Sci. Instrum. 74, 2068 (2003)] were implemented together to obtain spectroscopic data of limiter and first wall recycling and impurity sources during Wendelstein 7-X startup plasmas. Both systems together provided excellent temporal and spatial spectroscopic resolution of limiter 3. Narrowband interference filters in front of the camera yielded C-III and H{sub α} photon flux, and the filterscope system provided H{sub α}, H{sub β}, He-I, He-II, C-II, and visible bremsstrahlung data. The filterscopes made additional measurements of several points on the W7-X vacuum vessel to yield wall recycling fluxes. The resulting photon flux from both the visible camera and filterscopes can then be compared to an EMC3-EIRENE synthetic diagnostic [H. Frerichs et al., “Synthetic plasma edge diagnostics for EMC3-EIRENE, highlighted for Wendelstein 7-X,” Rev. Sci. Instrum. (these proceedings)] to infer both a limiter particle flux and wall particle flux, both of which will ultimately be used to infer the complete particle balance and particle confinement time τ{sub P}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 1D Lyman-alpha profile camera for plasma edge neutral studies on the DIII-D tokamak

A one dimensional, absolutely calibrated pinhole camera system was installed on the DIII-D tokamak to measure edge Lyman-alpha (Ly-α) emission from hydrogen isotopes, which can be used to infer neutral density and ionization rate profiles. The system is composed of two cameras, each providing a toroidal fan of 20 lines of sight, viewing the plasma edge on the inboard and outboard side of DIII-D. The cameras’ views lie in a horizontal plane 77 cm below the midplane. At its tangency radius, each channel provides a radial resolution of ~2 cm full width at half maximum (FWHM) with a total coverage of 22 cm. Each camera consists of a rectangular pinhole, Ly-α reflective mirror, narrow-band Ly-α transmission filter, and a 20 channel AXUV photodetector. The combined mirror and transmission filter have a FWHM of 5 nm, centered near the Ly-α wavelength of 121.6nm and is capable of rejecting significant, parasitic carbon-III (C-III) emission from intrinsic plasma impurities. To provide a high spatial resolution measurement in a compact footprint, the camera utilizes advanced engineering and manufacturing techniques including 3D printing, high stability mirror mounts, and a novel alignment procedure. Absolutely calibrated, spatially resolved Ly-α brightness measurements utilize a bright, isolated line with low parasitic surface reflections and enable quantitative comparison to modeling to study divertor neutral leakage, main chamber fueling, and radial particle transport.

Ionization Rate↗

Plate Impact and Penetration at the Ballistic Launch Tube: Experiments

This report details the data collected from plate impact experiments performed at the Ballistics Launch Tube (BLT) in May 2019. The experiments consisted of 62 shots of copper projectiles (cylindrical and ogive) impacting 1/4", 1/2", and 3/4" aluminum plates at varying velocities. An additional 14 shots of copper cylinders on a 1" steel plate were fired at varying velocities as a Taylor anvil test. We recorded videos of the impact events and resulting fragmentation using a multi-view system of three high speed cameras. The purpose of these tests was to collect high quality data from the multi-view camera system and create digital representations of the deformed target, projectile and fragments. This data is intended to be used as validation data set for high fidelity simulation codes. This report covers the experimental setup, diagnostics, and collected data. Data processing and analysis are underway and will be discussed in a separate report.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A 1D Lyman-alpha Profile Camera for Plasma Edge Neutral Studies on the DIII-D Tokamak

A one dimensional, absolutely calibrated pinhole camera system was installed on the DIII-D tokamak to measure edge Lyman-alpha (Ly-a) emission from hydrogenic isotopes which can be used to infer neutral density and ionization rate proles. The system is composed of two cameras, each providing a toroidal fan of twenty lines of sight, viewing the plasma edge on the inboard and outboard side of DIII-D. The cameras' views lie in a horizontal plane 77 cm below the midplane. At its tangency radius, each channel provides a radial resolution of approximately 2 cm full width at half maximum (FWHM) with a total coverage of 22 cm. Each camera consists of a rectangular pinhole, Ly-a reflective mirror, narrow-band Ly-a transmission fiter, and a 20 channel AXUV photodetector. The combined mirror and transmission fiter have a FWHM of 5 nm, centered near the Ly-a wavelength of 121.6 nm and is capable of rejecting significant, parasitic carbon-III (C-III) emission from intrinsic plasma impurities. To provide a high spatial resolution measurement in a compact footprint, the camera utilizes advanced engineering and manufacturing techniques including 3D printing, high stability mirror mounts, and a novel alignment procedure. Absolutely calibrated, spatially resolved Ly-a brightness measurements utilize a bright, isolated line with low parasitic surface reflections and enable quantitative comparison to modeling to study divertor neutral leakage, main chamber fueling and radial particle transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

UAV-Based High Resolution Thermal Imaging for Vegetation Monitoring, and Plant Phenotyping Using ICI 8640 P, FLIR Vue Pro R 640, and thermoMap Cameras

The growing popularity of Unmanned Aerial Vehicles (UAVs) in recent years, along with decreased cost and greater accessibility of both UAVs and thermal imaging sensors, has led to the widespread use of this technology, especially for precision agriculture and plant phenotyping. There are several thermal camera systems in the market that are available at a low cost. However, their efficacy and accuracy in various applications has not been tested. In this study, three commercially available UAV thermal cameras, including ICI 8640 P-series (Infrared Cameras Inc., USA), FLIR Vue Pro R 640 (FLIR Systems, USA), and thermoMap (senseFly, Switzerland) have been tested and evaluated for their potential for forest monitoring, vegetation stress detection, and plant phenotyping. Mounted on multi-rotor or fixed wing systems, these cameras were simultaneously flown over different experimental sites located in St. Louis, Missouri (forest environment), Columbia, Missouri (plant stress detection and phenotyping), and Maricopa, Arizona (high throughput phenotyping). Thermal imagery was calibrated using procedures that utilize a blackbody, handheld thermal spot imager, ground thermal targets, emissivity and atmospheric correction. A suite of statistical analyses, including analysis of variance (ANOVA), correlation analysis between camera temperature and plant biophysical and biochemical traits, and heritability were utilized in order to examine the sensitivity and utility of the cameras against selected plant phenotypic traits and in the detection of plant water stress. In addition, in reference to quantitative assessment of image quality from different thermal cameras, a non-reference image quality evaluator, which primarily measures image focus that is based on the spatial relationship of pixels in different scales, was developed. Our results show that (1) UAV-based thermal imaging is a viable tool in precision agriculture and (2) the three examined cameras are comparable in terms of their efficacy for plant phenotyping. Overall, accuracy, when compared against field measured ground temperature and estimating power of plant biophysical and biochemical traits, the ICI 8640 P-series performed better than the other two cameras, followed by FLIR Vue Pro R 640 and thermoMap cameras. Our results demonstrated that all three UAV thermal cameras provide useful temperature data for precision agriculture and plant phenotying, with ICI 8640 P-series presenting the best results among the three systems. Cost wise, FLIR Vue Pro R 640 is more affordable than the other two cameras, providing a less expensive option for a wide range of applications.

47 OTHER INSTRUMENTATION↗

SU-E-J-139: One Institution’s Experience with Surface Imaging in Proton Therapy

Purpose: X-ray system is commonly used for IGRT in proton therapy, however image acquisition not only increases treatment time but also adds imaging dose. We studied a 3D surface camera system (AlignRT) performance for proton therapy. Methods: System accuracy was evaluated with rigid phantom under two different camera location configurations. For initial clinical applications, post mastectomy chest wall and partial breast treatments were studied. X-ray alignment was used as our ground truth. Our studies included: 1) comparison of daily patient setup shifts between X-ray alignment and SI calculation; 2) interfractional breast surface position variation when aligning to bony landmark on X-ray; 3) absolute positioning using planning CT DICOM data; 4) shifts for multi-isocenter treatment plan; 5) couch isocentric rotation accuracy. Results: Camera locations affected the system performance. After camera relocation, the accuracy of the system for the rigid phantom was within 1 mm (fixed couch), and 1.5 mm (isocentric rotation). For intrafractional patient positioning, X-ray and AlignRT shifts were highly correlated (r=0.99), with the largest difference (mean ± SD) in the longitudinal direction (2.14 ± 1.02 mm). For interfractional breast surface variation and absolute positioning, there were still larger disagreements between the two modalities due to different focus on anatomical landmarks, and 95% of the data lie within 5mm with some outliers at 7 mm–9 mm. For multi-isocenter shifts, the difference was 1 ± 0.56 mm over an 11 cm shift in longitudinal direction. For couch rotation study, the differences was 1.36 ± 1.0 mm in vertical direction, 3.04 ± 2.11 mm in longitudinal direction, and 2.10 ± 1.66 mm in lateral direction, with all rotation differences < 1.5 degree. Conclusion: Surface imaging is promising for intrafractional treatment application in proton therapy to reduce X-ray frequency. However the interfractional discrepancy between the X-ray and SI requires future validation.

60 APPLIED LIFE SCIENCES↗

Metallography Box Improvements

The information included in this poster is designed to provide information on a visualization system needed in a hot-cell with a high radiation dose level. The system is necessary to enable real-time remote monitoring of microscope function. The current configuration for viewing function of in-cell equipment is through a single window. This makes for difficult viewing of the microscope workstations which are located away from the window. A properly designed camera system enhances troubleshooting capability in-cell. The poster will aid in the exposition of the design process and implementation of the system described above.

42 ENGINEERING↗

Characterization of Orography-Influenced Riming and Secondary Ice Production and Their Effects on Precipitation Rates Using Radar Polarimetry and Doppler Spectra (CORSIPP-SAIL)

The Characterization of Orography-Influenced Riming and Secondary Ice Production and Their Effects on Precipitation Rates Using Radar Polarimetry and Doppler Spectra (CORSIPP) project was conducted to help improve the understanding of precipitation formation in orographically influenced terrain. Special focus is put on the two processes of riming and secondary ice production and their external drivers. Two instruments, a polarimetric W-band simultaneous transmission simultaneous reception (STSR) Doppler cloud radar manufactured by Radiometer Physics GmbH (RPG, instrument type RPG-FMCW-94-DP), from now on named LIMRAD94, and the video in situ snowfall sensor (VISSS), were deployed at the U. S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Surface Atmosphere Integrated Field Laboratory (SAIL) site in Gothic, Colorado between November 2022 and June 2023 during the second SAIL winter. Note that the exact dates of data availability differ between the instruments. Both instruments arrived at Gothic on November 2, 2022, 09:20 local time. VISSS, described by Maahn et al., is equipped with two camera systems with telecentric lenses. The two cameras are at a 90° angle to each other. This configuration allows for size-independent measurements by capturing images of hydrometeors from two sides at a high frame rate of 250 Hz. With a minimum detection size of 200 μm, VISSS provides valuable insights into particle size, number, shape, complexity, and fall velocity. The VISSS was deployed on the grassland next to the ARM facility with the amazing help of the ARM employees on site. The setup started on November 2, 2022, and was finished on November 5, 2022, without major problems. VISSS measurements were started on November 6, 2022. LIMRAD94 was installed on a scaffolding platform near Orehouse (Gothic) on November 9, 2022, with the great help of RMBL staff. LIMRAD94 was mounted on a cold temperature scanner prototype. After a short test of the setup on November 9, 2022, the digital control of the scanner elevation stopped working for (at that time) unknown reasons. All attempts to resolve the problem failed. This malfunction made it impossible to operate LIMRAD94 in scanning mode. The scanner was then manually moved to zenith pointing mode and between November 10 and November 15, 2022, vertical observations for polarimetric calibration were performed. On November 15, 2022, after the polarimetric calibration was applied, the scanner was manually moved to 40° elevation with azimuthal view towards the Ka-band ARM Zenith Radar (KAZR) and measurements were continued at constant elevation. Investigation of the scanner malfunction on February 6, 2023, by Benn Schmatz revealed a disengagement between the cogwheel of the elevation motor and the cogwheel moving the scanner in elevation. This mechanical issue was temporarily solved by re-engaging the cogwheels. This made the scanner operational again for about four weeks, until mechanical force disengaged the cogwheels again on March 15, 2023. This repeated scanner failure remained undetected for about three weeks until April 8, 2023; during this time the scanner was stuck at 72° elevation. However, the radar software continued to produce data files falsely indicating that the scanner was still operational. After the scanner failure was noticed, scanning was stopped again, and we returned to constant elevation measurements. On May 15, 2023, the cogwheels of the elevation motor were secured with additional screws sent by the manufacturer. At some point in May, the cogwheels of the azimuth motor were also disengaged by mechanical force, which still allowed for range height indicator (RHI) but no plan position indicator (PPI) scans in the last weeks of the campaign. The azimuth motor was repaired in Germany after the end of the campaign. Throughout the campaign, RMBL and ARM staff kept the radar and the VISSS free of snow.

54 ENVIRONMENTAL SCIENCES↗

Equipment Operational Requirements

The Iraq Department of Border Enforcement is rich in personnel, but poor in equipment. An effective border control system must include detection, discrimination, decision, tracking and interdiction, capture, identification, and disposition. An equipment solution that addresses only a part of this will not succeed, likewise equipment by itself is not the answer without considering the personnel and how they would employ the equipment. The solution should take advantage of the existing in-place system and address all of the critical functions. The solutions are envisioned as being implemented in a phased manner, where Solution 1 is followed by Solution 2 and eventually by Solution 3. This allows adequate time for training and gaining operational experience for successively more complex equipment. Detailed descriptions of the components follow the solution descriptions. Solution 1 - This solution is based on changes to CONOPs, and does not have a technology component. It consists of observers at the forts and annexes, forward patrols along the swamp edge, in depth patrols approximately 10 kilometers inland from the swamp, and checkpoints on major roads. Solution 2 - This solution adds a ground sensor array to the Solution 1 system. Solution 3 - This solution is based around installing a radar/video camera system on each fort. It employs the CONOPS from Solution 1, but uses minimal ground sensors deployed only in areas with poor radar/video camera coverage (such as canals and streams shielded by vegetation), or by roads covered by radar but outside the range of the radar associated cameras. This document provides broad operational requirements for major equipment components along with sufficient operational details to allow the technical community to identify potential hardware candidates. Continuing analysis will develop quantities required and more detailed tactics, techniques, and procedures.

42 ENGINEERING↗

The fast camera (Fastcam) imaging diagnostic systems on the DIII-D tokamak

Two camera systems are installed on the DIII-D tokamak at the toroidal positions of 90° (90° system) and 225° (225° system), respectively. The cameras have two types of relay optics, namely, a coherent optical fiber bundle and a periscope system. The periscope system provides absolute intensity calibration stability while sacrificing resolution (10 lp/mm), while the fiber system provides high resolution (16 lp/mm) while sacrificing calibration stability. The periscope is available only for the 90° system. The optics of the 225° system were designed for view stability, repeatability, and easy maintenance. The cameras are located inside optimized neutron, x ray and magnetic shielding in order to reduce electronics damage, reboots, and magnetic and neutron interference, increasing the overall system reliability. An automated filter wheel, providing remote filter change, allows for remote wavelength selection. A software suite automates camera acquisition and data storage, allowing for remote operation and reduced operator involvement. System metadata is used to streamline the data analysis workflow, particularly for intensity calibration. Here, the spatial calibration uses multiple observable wall features, resulting in a reconstruction accuracy ≤2 cm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TH-AB-202-11: Spatial and Rotational Quality Assurance of 6DOF Patient Tracking Systems

Purpose: External tracking systems used for patient positioning and motion monitoring during radiotherapy are now capable of detecting both translations and rotations (6DOF). In this work, we develop a novel technique to evaluate the 6DOF performance of external motion tracking systems. We apply this methodology to an infrared (IR) marker tracking system and two 3D optical surface mapping systems in a common tumor 6DOF workspace. Methods: An in-house designed and built 6DOF parallel kinematics robotic motion phantom was used to follow input trajectories with sub-millimeter and sub-degree accuracy. The 6DOF positions of the robotic system were then tracked and recorded independently by three optical camera systems. A calibration methodology which associates the motion phantom and camera coordinate frames was first employed, followed by a comprehensive 6DOF trajectory evaluation, which spanned a full range of positions and orientations in a 20×20×16 mm and 5×5×5 degree workspace. The intended input motions were compared to the calibrated 6DOF measured points. Results: The technique found the accuracy of the IR marker tracking system to have maximal root mean square error (RMSE) values of 0.25 mm translationally and 0.09 degrees rotationally, in any one axis, comparing intended 6DOF positions to positions measured by the IR camera. The 6DOF RSME discrepancy for the first 3D optical surface tracking unit yielded maximal values of 0.60 mm and 0.11 degrees over the same 6DOF volume. An earlier generation 3D optical surface tracker was observed to have worse tracking capabilities than both the IR camera unit and the newer 3D surface tracking system with maximal RMSE of 0.74 mm and 0.28 degrees within the same 6DOF evaluation space. Conclusion: The proposed technique was effective at evaluating the performance of 6DOF patient tracking systems. All systems examined exhibited tracking capabilities at the sub-millimeter and sub-degree level within a 6DOF workspace.

60 APPLIED LIFE SCIENCES↗

X-Ray Spectroscopic Studies of X-Pinch Plasmas with 3-5 Picosecond Resolution: A Quest for Clear Experimental Evidence for Radiative Collapse in the X-ray Spectra (Final Report)

Dense Z-pinch plasmas produced from current-carrying exploding wires frequently produce very brief (less than 0.1 nanosecond), intense, bursts of soft X-rays from tiny (about 1 micrometer), very hot (10-30 million K) regions of the plasma. This project addresses the physical processes that lead to those tiny, high-energy density plasmas and develops means to measure the conditions just before and during the X-ray bursts. One possible relevant process is radiative collapse, which starts if the power radiated by a dense Z-pinch, proportional to the density-squared, exceeds the resistive heating rate from the current flow, thereby cooling the plasma and enabling the magnetic pinching force to exceed the outward plasma thermal pressure. As the resulting radius reduction further increases the radiation rate, this process produces a runaway magnetic implosion. A competing mechanism is a sausage-like instability that can develop in a Z-pinch plasma at a lower current than is needed to induce radiative collapse. This mechanism can also produce tiny hot spots in the neck regions of the sausage-shaped plasma column. It is also possible that these two mechanisms work together to produce the X-ray emitting hot spots. If radiative collapse does contribute to hot spot formation, it would be terminated when the plasma becomes so dense that the radiation cannot escape, enabling the plasma kinetic pressure to build up and stop the current-driven implosion. This project aims to study the development of the hot spots by means of high temporal and spatial resolution X-ray spectroscopy to determine if there is evidence for the presence of the radiative collapse mechanism. Progress toward this goal is presented. To summarize, during the four-year period 09/15/2017 - 9/14/2021, we have collected necessary spectroscopic data to determine the plasma conditions and continue to do so. We are also now in the process of calibrating diagnostic systems (especially the x-ray streak camera system) and analyzing data to determine plasma conditions as a function of time before, during and after the X-ray burst.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗