Search NASA⌕ Search

SEARCH · Search NASA

Results for “capacitive loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Experimental Evaluation of PV Inverter Anti-Islanding with Grid Support Functions in Multi-Inverter Island Scenarios

As PV and other DER systems are connected to the grid at increased penetration levels, island detection may become more challenging for two reasons: 1.) In islands containing many DERs, active inverter-based anti-islanding methods may have more difficulty detecting islands because each individual inverter's efforts to detect the island may be interfered with by the other inverters in the island. 2.) The increasing numbers of DERs are leading to new requirements that DERs ride through grid disturbances and even actively try to regulate grid voltage and frequency back towards nominal operating conditions. These new grid support requirements may directly or indirectly interfere with anti-islanding controls. This report describes a series of tests designed to examine the impacts of both grid support functions and multi-inverter islands on anti-islanding effectiveness. Crucially, the multi-inverter anti-islanding tests described in this report examine scenarios with multiple inverters connected to multiple different points on the grid. While this so-called 'solar subdivision' scenario has been examined to some extent through simulation, this is the first known work to test it using hardware inverters. This was accomplished through the use of power hardware-in-the-loop (PHIL) simulation, which allows the hardware inverters to be connected to a real-time transient simulation of an electric power system that can be easily reconfigured to test various distribution circuit scenarios. The anti-islanding test design was a modified version of the unintentional islanding test in IEEE Standard 1547.1, which creates a balanced, resonant island with the intent of creating a highly challenging condition for island detection. Three common, commercially available single-phase PV inverters from three different manufacturers were tested. The first part of this work examined each inverter individually using a series of pure hardware resistive-inductive-capacitive (RLC) resonant load based anti-islanding tests to determine the worst-case configuration of grid support functions for each inverter. A grid support function is a function an inverter performs to help stabilize the grid or drive the grid back towards its nominal operating point. The four grid support functions examined here were voltage ride-through, frequency ride-through, Volt-VAr control, and frequency-Watt control. The worst-case grid support configuration was defined as the configuration that led to the maximum island duration (or run-on time, ROT) out of 50 tests of each inverter. For each of the three inverters, it was observed that maximum ROT increased when voltage and frequency ride-through were activated. No conclusive evidence was found that Volt-VAr control or frequency-Watt control increased maximum ROT. Over all single-inverter test cases, the maximum ROT was 711 ms, well below the two-second limit currently imposed by IEEE Standard 1547-2003. A subsequent series of 244 experiments tested all three inverters simultaneously in the same island. These tests again used a procedure based on the IEEE 1547.1 unintentional islanding test to create a difficult-to-detect island condition. For these tests, which used the two worst-case grid support function configurations from the single-inverter tests, the inverters were connected to a variety of island circuit topologies designed to represent the variety of multiple-inverter islands that may occur on real distribution circuits. The interconnecting circuits and the resonant island load itself were represented in the real-time PHIL model. PHIL techniques similar to those employed here have been previously used and validated for anti-islanding tests, and the PHIL resonant load model used in this test was successfully validated by comparing single-inverter PHIL tests to conventional tests using an RLC load bank.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The design of hydraulic pressure regulators that are stable without the use of sensing line restrictors or frictional dampers

A direct-acting hydraulic pressure regulator design which incorporates stability margin, response and droop margin is developed. The pressure regulator system does not involve a nonlinear sensing line restrictor (which may degrade transient response) or linear damping (which is sensitive to clearance and viscosity). The direct-acting hydraulic pressure regulator makes use of the technique of lead network stabilization (i.e., the tuned stabilizer concept). An analytically derived circuit pressure regulator is tested to study the stability limit under a parallel capacitive plus resistive load and the stabilizing effect of the tuned stabilizer.

Gold, H.↗

Extended Characterization of the Common-Source and Common-Gate Amplifiers using a Metal-Ferroelectric-Semiconductor Field Effect Transistor

Collected data for both common-source and common-gate amplifiers is presented in this paper. Characterizations of the two amplifier circuits using metal-ferroelectric-semiconductor field effect transistors (MFSFETs) are developed with wider input frequency ranges and varying device sizes compared to earlier characterizations. The effects of the ferroelectric layer's capacitance and variation load, quiescent point, or input signal on each circuit are discussed. Comparisons between the MFSFET and MOSFET circuit operation and performance are discussed at length as well as applications and advantages for the MFSFETs.

Hunt, Mitchell↗

Shuttle propellant loading instrumenation development

A continuous capacitance sensor was developed and an analog signal conditioner was evaluated to demonstrate the acceptability of these items for use in the space shuttle propellant loading system. An existing basic sensor concept was redesigned to provide capability for cryogenic operation, to improve performance, and to minimize production costs. Sensor development verification consisted of evaluation of sensor linearity, cryogenic performance, and stability during vibration. The signal conditioner evaluation consisted mainly of establishing the effects of the variations in temperature and cable parameters and evaluating the stability. A sensor linearity of 0.04 in. was achieved over most of the sensor length. The sensor instability caused by vibration was 0.04 percent. The cryogenic performance data show a maximum instability of 0.19 percent at liquid hydrogen temperature; a theoretical calibration can be computed a within 1 percent. The signal conditioner evaluation showed that, with temperature compensation, all error sources typically contribute much less than 1 percent. An estimate of the accuracy achievable with the sensor and signal conditioner shows an rss estimate of 0.75 in. for liquid oxygen and 1.02 in. for liquid hydrogen. These are approximately four times better than the shuttle requirements. Comparison of continuous sensor and discrete sensor performance show the continuous sensor to be significantly better when there is surface activity due to sloshing, boiling, or other disturbances.

Hamlet, J.↗

Integrated Stirling Convertor and Hall Thruster Test Conducted

An important aspect of implementing Stirling Radioisotope Generators on future NASA missions is the integration of the generator and controller with potential spacecraft loads. Some recent studies have indicated that the combination of Stirling Radioisotope Generators and electric propulsion devices offer significant trip time and payload fraction benefits for deep space missions. A test was devised to begin to understand the interactions between Stirling generators and electric thrusters. An electrically heated RG- 350 (350-W output) Stirling convertor, designed and built by Stirling Technology Company of Kennewick, Washington, under a NASA Small Business Innovation Research agreement, was coupled to a 300-W SPT-50 Hall-effect thruster built for NASA by the Moscow Aviation Institute (RIAME). The RG-350 and the SPT-50 shown, were installed in adjacent vacuum chamber ports at NASA Glenn Research Center's Electric Propulsion Laboratory, Vacuum Facility 8. The Stirling electrical controller interfaced directly with the Hall thruster power-processing unit, both of which were located outside of the vacuum chamber. The power-processing unit accepted the 48 Vdc output from the Stirling controller and distributed the power to all the loads of the SPT-50, including the magnets, keeper, heater, and discharge. On February 28, 2001, the Glenn test team successfully operated the Hall-effect thruster with the Stirling convertor. This is the world's first known test of a dynamic power source with electric propulsion. The RG-350 successfully managed the transition from the purely resistive load bank within the Stirling controller to the highly capacitive power-processing unit load. At the time of the demonstration, the Stirling convertor was operating at a hot temperature of 530 C and a cold temperature of -6 C. The linear alternator was producing approximately 250 W at 109 Vac, while the power-processing unit was drawing 175 W at 48 Vdc. The majority of power was delivered to the Hall thruster discharge circuit operating at 115 Vdc and 0.9 A. Testing planned for late 2001 will examine the possibility of directly driving the Hall thruster discharge circuit using rectified and filtered output from the Stirling alternator.

Mason, Lee S.↗

Advanced Power Conditioning System

The second portion of the advanced power conditioning system development program is reported. Five 100-watt parallel power stages with majority-vote-logic feedback-regulator were breadboarded and tested to the design goals. The input voltage range was 22.1 to 57.4 volts at loads from zero to 500 watts. The maximum input ripple current was 200 mA pk-pk (not including spikes) at 511 watts load; the output voltage was 56V dc with a maximum change of 0.89 volts for all variations of line, load, and temperature; the maximum output ripple was 320 mV pk-pk at 512 watts load (dependent on filter capacitance value); the maximum efficiency was 93.9% at 212 watts and 50V dc input; the minimum efficiency was 87.2% at 80-watt load and 50V dc input; the efficiency was above 90% from 102 watts to 372 watts; the maximum excursion for an 80-watt load change was 2.1 volts with a recovery time of 7 milliseconds; and the unit performed within regulation limits from -20 C to +85 C. During the test sequence, margin tests and failure mode tests were run with no resulting degradation in performance.

Johnson, N. L.↗

Focused excimer laser initiated, radio frequency sustained high pressure air plasmas

Measurements and analysis of air breakdown processes and plasma production by focusing 193 nm, 300 mJ, 15 MW high power laser radiation inside a 6 cm diameter helical radio frequency (RF) coil are presented. Quantum resonant multi-photon ionization (REMPI) and collisional cascade laser ionization processes are exploited that have been shown to produce high-density (n{sub e} {approx} 7 x 10{sup 16}/cm{sup 3}) cylindrical seed plasmas at 760 Torr. Air breakdown in lower pressures (from 7-22 Torr), where REMPI is the dominant laser ionization process, is investigated using an UV 18 cm focal length lens, resulting in a laser flux of 5.5 GW/cm{sup 2} at the focal spot. The focused laser power absorption and associated shock wave produce seed plasmas for sustainment by the RF (5 kW incident power, 1.5 s) pulse. Measurements of the helical RF antenna load impedance in the inductive and capacitive coupling regimes are obtained by measuring the loaded antenna reflection coefficient. A 105 GHz interferometer is used to measure the plasma electron density and collision frequency. Spectroscopic measurements of the plasma and comparison with the SPECAIR code are made to determine translational, rotational, and vibrational neutral temperatures and the associated neutral gas temperature. From this and the associated measurement of the gas pressure the electron temperature is obtained. Experiments show that the laser-formed seed plasma allows RF sustainment at higher initial air pressures (up to 22 Torr) than that obtained via RF-only initiation (<18 Torr) by means of a 0.3 J UV laser pulse.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Online Learning for Commercial Buildings

There has been an increased interest in designing optimization based techniques for the control of building heating, ventilation, and air-conditioning (HVAC) systems for either improving the energy efficiency of buildings or providing ancillary services to the electric grid. The performance of such prediction-based control techniques heavily rely on the model of a building’s thermal dynamics. However, the development of high fidelity building thermal dynamic models is challenging given the presence of large uncertainties that affect thermal loads in buildings such as building envelope performance, thermal mass, internal heat gains as well as occupants' behavior. In this paper, we propose a method to identify both a resistive-capacitive parametric model, and non -parametric load uncertainties using measured input-output data. The parametric model is obtained using semi-parametric regression, whereas the non-parametric part is based on Random Forest, where regression trees are used to derive the dependency of non-parametric terms on both building operation parameters and ambient temperature. The effectiveness of the method is evaluated using experimental data collected from an office building at the Pacific Northwest National Laboratory (PNNL) campus. The proposed methodology was observed to provide improved accuracy over appropriate baseline strategies, when predicting indoor air temperatures.

Dong, Jin↗

Advanced Stirling Convertor Dual Convertor Controller Testing at NASA Glenn Research Center in the Radioisotope Power Systems System Integration Laboratory

NASA Glenn Research Center (GRC) developed a non-nuclear representation of a Radioisotope Power System (RPS) consisting of a pair of Advanced Stirling Convertors (ASC), a Dual Convertor Controller (DCC) EM (engineering model) 2 & 3, and associated support equipment, which were tested in the Radioisotope Power Systems System Integration Laboratory (RSIL). The DCC was designed by the Johns Hopkins University/Applied Physics Laboratory (JHU/APL) to actively control a pair of Advanced Stirling Convertors (ASC). The first phase of testing included a Dual Advanced Stirling Convertor Simulator (DASCS) which was developed by JHU/APL and simulates the operation and electrical behavior of a pair of ASC's in real time via a combination of hardware and software. RSIL provides insight into the electrical interactions between a representative radioisotope power generator, its associated control schemes, and realistic electric system loads. The first phase of integration testing included the following spacecraft bus configurations: capacitive, battery, and supercapacitor. A load profile, created based on data from several missions, tested the RPS and RSIL ability to maintain operation during load demands above and below the power provided by the RPS. The integration testing also confirmed the DCC's ability to disconnect from the spacecraft when the bus voltage dipped below 22 V or exceeded 36 V. Once operation was verified with the DASCS, the tests were repeated with actual operating ASC's. The goal of this integration testing was to verify operation of the DCC when connected to a spacecraft and to verify the functionality of the newly designed RSIL. The results of these tests are presented in this paper.

systems integration↗

DC-to-DC switching converter

A dc-to-dc converter having nonpulsating input and output current uses two inductances, one in series with the input source, the other in series with the output load. An electrical energy transferring device with storage, namely storage capacitance, is used with suitable switching means between the inductances to DC level conversion. For isolation between the source and load, the capacitance may be divided into two capacitors coupled by a transformer, and for reducing ripple, the inductances may be coupled. With proper design of the coupling between the inductances, the current ripple can be reduced to zero at either the input or the output, or the reduction achievable in that way may be divided between the input and output.

Cuk, Slobodan M.↗

Microgrid Tiered Circuits Effects for a Planned Housing Community in Puerto Rico

Puerto Rico faced a double strike from hurricanes Irma and Maria in 2017. The resulting damage required a comprehensive rebuild of electric infrastructure. There are plans and pilot projects to rebuild with microgrids to increase resilience. This paper provides a techno-economic analysis technique and case study of a potential future community in Puerto Rico that combines probabilistic microgrid design analysis with tiered circuits in building energy modeling. Tiered circuits in buildings allow electric load reduction via remote disconnection of non-critical circuits during an emergency. When coupled to a microgrid, tiered circuitry can reduce the chances of a microgrid's storage and generation resources being depleted. The analysis technique is applied to show 1) Approximate cost savings due to a tiered circuit structure and 2) Approximate cost savings gained by simultaneously considering resilience and sustainability constraints in the microgrid optimization. The analysis technique uses a resistive capacitive thermal model with load profiles for four tiers (tier 1-3 and non-critical loads). Three analyses were conducted using: 1) open-source software called Tiered Energy in Buildings and 2) the Microgrid Design Toolkit. For a fossil fuel based microgrid 30% of the total microgrid costs of 1.18 million USD were calculated where the non-tiered case keeps all loads 99.9% available and the tiered case keeps tier 1 at 99.9%, tier 2 at 95%, tier 3 at 80% availability, with no requirement on non-critical loads. The same comparison for a sustainable microgrid showed 8% cost savings on a 5.10 million USD microgrid due to tiered circuits. The results also showed 6-7% cost savings when our analysis technique optimizes sustainability and resilience simultaneously in comparison to doing microgrid resilience analysis and renewables net present value analysis independently. Though highly specific to our case study, similar assessments using our analysis technique can elucidate value of tiered circuits and simultaneous consideration of sustainability and resilience in other locations.

building energy modeling↗

Silicon controlled rectifier polyphase bridge inverter commutated with gate-turn-off thyristor

A polyphase SCR inverter (10) having N switching poles, each comprised of two SCR switches (1A, 1B; 2A, 2B . . . NA, NB) and two diodes (D1B; D1B; D2A, D2B . . . DNA, DNB) in series opposition with saturable reactors (L1A, L1B; L2A, L2B . . . LNA, LNB) connecting the junctions between the SCR switches and diodes to an output terminal (1, 2 . . . 3) is commutated with only one GTO thyristor (16) connected between the common negative terminal of a dc source and a tap of a series inductor (14) connected to the positive terminal of the dc source. A clamp winding (22) and diode (24) are provided, as is a snubber (18) which may have its capacitance (c) sized for maximum load current divided into a plurality of capacitors (C.sub.1, C.sub.2 . . . C.sub.N), each in series with an SCR switch S.sub.1, S.sub.2 . . . S.sub.N). The total capacitance may be selected by activating selected switches as a function of load current. A resistor 28 and SCR switch 26 shunt reverse current when the load acts as a generator, such as a motor while braking.

Edwards, Dean B.↗

Rapid synthesis of transition metal dichalcogenide–carbon aerogel composites for supercapacitor electrodes

Transition metal dichalcogenide (TMD) materials have recently demonstrated exceptional supercapacitor properties after conversion to a metallic phase, which increases the conductivity of the network. However, freestanding, exfoliated transition metal dichalcogenide films exhibit surface areas far below their theoretical maximum (1.2 %), can fail during electrochemical operation due to poor mechanical properties, and often require pyrophoric chemicals to process. On the other hand, pyrolyzed carbon aerogels exhibit extraordinary specific surface areas for double layer capacitance, high conductivity, and a strong mechanical network of covalent chemical bonds. In this paper, we demonstrate the scalable, rapid nanomanufacturing of TMD (MoS2 and WS2) and carbon aerogel composites, favoring liquid-phase exfoliation to avoid pyrophoric chemicals. The aerogel matrix support enhances conductivity of the composite and the synthesis can complete in 30 min. We find that the addition of transition metal dichalcogenides does not impact the structure of the aerogel, which maintains a high specific surface area up to 620 m2 g-1 with peak pore radii of 10 nm. While supercapacitor tests of the aerogels yield capacitances around 80 F g-1 at the lowest applied currents, the aerogels loaded with TMD’s exhibit volumetric capacitances up to 127% greater than the unloaded aerogels. In addition, the WS2 aerogels show excellent cycling stability with no capacitance loss over 2000 cycles, as well as markedly better rate capability and lower charge transfer resistance compared to their MoS2-loaded counterparts. We hypothesize that these differences in performance stem from differences in contact resistance and in the favorability of ion adsorption on the chalcogenides.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Multiphase Control for Robust and Complete Soft-Charging Operation of Dual Inductor Hybrid Converter

This paper presents a new Multiphase Dual Inductor Hybrid (MP-DIH) Converter for application in data center and telecommunication systems. The converter is based on addition of two output filter inductors to a Dickson switched-capacitor converter. The inductors are operated in multiple phases that are non-overlapped and evenly distributed over one switching cycle, completely soft-charging all flying capacitors even in the presence of practical capacitor mismatches and voltage ripples. In this converter operation, each branch of the switched-capacitor network is activated individually in one charging phase, and two interleaved inductors are employed to softly charge and discharge the capacitors to achieve high efficiency without any complex capacitor sizing or split phase operation. To verify the topology and its soft-charging advantages, a 48V-to-1.8V 20W experimental converter prototype is constructed. The converter achieves 92.4% peak efficiency for 40V-to-1.8V conversion and 92.1% peak efficiency for 48V-to-1.8V conversion at 4A load, and with 20% capacitance variations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

In Situ Monitoring of Direct Ink Write Process Using Electromagnetic Resonant Coupling

Additive manufacturing (AM) of multi-material objects enables the design of complex 3D architectures such as printed electronics and devices. The ability to detect the composition of multi-material printed inks in real time is an emerging need for a wide range of manufacturing applications. This study demonstrates the feasibility of using an in situ sensor to locally measure the composition of inks as they are being printed to facilitate greater control over the resulting properties and functionality of printed materials. Dielectric properties of microscale embedded metal particles in a dielectric matrix are measured and characterized as a function of particle size, shape, volume percentage and frequency. Results show that particle shape has a much greater influence on impedance measurements than the particle size. Measurements are found to agree with calculations based on an anisotropic Maxwell-Garnett dielectric function model. The resulting data can be used to generate a calibration curve correlating metal loading with impedance or capacitance and thus applied as an in situ sensor for compositional measurements during extrusion-based AM.

36 MATERIALS SCIENCE↗

Optimizing indium antimonide (InSb) detectors for low background operation

The various noise sources that affect InSb detectors (and similar voltaic devices) are discussed and calculated. Methods are given for measuring detector resistance, photon loading, detector and amplifier capacitance, amplifier frequency response, amplifier noise, and quantum efficiency. A photovoltaic InSb detector with increased sensitivity in the 1 to 5.6 mu region is dicussed.

Treffers, R. R.↗

Modeling and Analysis of Stirling Power Convertors

Modeling and Analysis of Stirling Power Convertors Luis A. Rodriguez1 Steven M. Geng, Terry V. Reid, Scott D. Wilson NASA Glenn Research Center, Cleveland, OH, 44135, USA NASA Glenn’s Thermal Energy Conversion Branch is supporting the development of the next generation free-piston Stirling power convertors. American Superconductor (AMSC) and Sunpower Inc. are the two firms under contract to develop the Flexure Isotope Stirling Convertor (FISC) and the Sunpower Robust Stirling Convertor (SRSC), respectively. To comprehend and forecast convertor performance, Sage, ANSYS® Maxwell, and ANSYS® Fluent were used to model the Stirling thermodynamic cycle, alternator electromagnetics, and piston and displacer dynamics. I. Introduction Stirling convertors are being developed by NASA as a potential steady source of electrical power for NASA’s future scientific space missions. Currently, NASA Glenn Research Center has two corporations under contract, American Superconductor (AMSC) and Sunpower Inc., for the development of the next generation of free-piston Stirling convertors for dynamic radioisotope power systems. AMSC is developing the Flexure Isotope Stirling Convertor (FISC), which uses flexures to prevent side motion and rubbing of the piston. Similarly, Sunpower Inc, is developing the Sunpower Robust Stirling Convertor (SRSC). The SRSC uses gas bearings to prevent radial contact of the moving piston. As convertor development continues, it is increasingly important to understand and predict the interactions of components in the system, how they respond to one another, and how they perform as a response to changes in operating conditions. A suitable and enlightening way to demonstrate and foresee these interactions is with the use of accurate modeling software. Sage, ANSYS® Maxwell, and ANSYS® Fluent are the current modeling tools used by NASA to analytically determine convertor performance. Sage is a one-dimensional object-oriented commercial software package used for modeling and optimizing Stirling convertors for Dynamic Radioisotope Power Systems (DRPS) and it is one of the most accurate Stirling convertor codes in use by NASA. This code is the successor to GLIMPS (Globally-Implicit Stirling Cycle Simulation) and GLOP (GLIMPS Optimization) software created by Gedeon Associates [1]. Model input parameters are typically material/gas type, component physical dimensions, temperatures, frequency, charge pressure, and number of time/space nodes. Sage is used to model both the FISC’s and SRSC’s Stirling cycle thermodynamics and piston/displacer dynamics. Performance maps were created and analyzed for both power systems to better understand the relationship between the following conditions: cold-end temperature, hot-end temperature, piston/displacer amplitudes, pressure drop, and thermal input power. The synergy between these conditions will help determine parameter sensitivity. ANSYS® Maxwell was used to create a three-dimensional (3-D) axisymmetric model for both FISC and SRSC alternators. The significant physical components included in each model are the magnets, magnet carrier, outer/inner laminations, and the coil. Inputs to the model are piston amplitude, piston frequency, alternator load, coil resistance, tuning capacitance, and specific material properties. The alternator models calculate terminal voltage, current, piston/current phase, voltage/current phase, coil inductance, terminal power and efficiency. The RI2 losses, core (hysteresis and eddy) losses, and magnet/can eddy losses are also a part of the final results. ANSYS® Fluent is used to build 3-D computational fluid dynamic (CFD) models to examine the Stirling cycle thermodynamics for both the FISC and SRSC systems. Three-dimensional Computer Aided Design (CAD) models were used to create the physical components of each convertor. Steady-state simulations were conducted for hardware testing, prediction of environmental losses during testing, and generation of radiation look-up tables. The model inputs to the aforementioned analysis are the material properties and boundary thermal conditions. The steady-state model calculates temperature and heat flow distributions. Transient 3-D calculations were also part of the CFD analysis. In this study a physically reduced version of the FISC is used to obtain a prediction of available engine power. For the gas bearing SRSC, the transient effort is used to obtain a prediction of bearing pad performance and its sensitivity to micro-channel geometric variation. The model inputs to the transient simulations are the piston amplitude, displacer amplitude, frequency, displacer/piston phase angle, dynamic deforming CFD grid, temperature boundary conditions, and user defined files describing motion profile of piston/displacer. The results of the model are temperature distributions, heat distributions, and PV power produced at pre-determined conditions.

Luis A Rodriguez↗