Search NASA⌕ Search

SEARCH · Search NASA

Results for “capacity utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Wyoming Trails Carbon Hub (WyoTCH)

The Wyoming Trails Carbon Hub (WyoTCH) project completed a front-end engineering and design (FEED) study for a commercial-scale, open-access carbon dioxide (CO 2 ) transport pipeline in Wyoming under U.S. Department of Energy (DOE) Award DEFE0032347, funded through the Bipartisan Infrastructure Law Carbon Capture Technology Program and administered by the National Energy Technology Laboratory. The project’s approach of designing a multi-source, multi-destination pipeline, rather than a dedicated line serving a single project, would lower the barrier to entry for individual CO 2 projects. The projects would leverage Wyoming's concentrated industrial and power generation CO 2 sources, its existing CO 2 pipeline infrastructure, and its extensive CO 2 storage and utilization capacity. This is the project's final technical report.

01 COAL, LIGNITE, AND PEAT↗

Synthesis, structural and electrochemical properties of V4O9 cathode for lithium batteries

Single-phase three-dimensional vanadium oxide (V 4 O 9 ) was synthesized by reduction of V 2 O 5 using a gas stream of ammonia/argon (NH 3 /Ar). The as-synthesized oxide, prepared by this simple gas reduction method was subsequently electrochemically transformed into a disordered rock salt type-“Li3.7V4O9” phase while cycling over the voltage window 3.5 to 1.8 V versus Li. The Li-deficient phase delivers an initial reversible capacity of ∼260 mAhg −1 at an average voltage of 2.5 V vs. Li + /Li 0 . Further cycling to 50 cycles yields a steady 225 mAhg −1 . Ex situ X-ray diffraction studies confirmed that (de) intercalation phenomena follows a solid-solution electrochemical reaction mechanism. As demonstrated, the reversibility and capacity utilization of this V 4 O 9 is found to be superior to battery grade, micron-sized V 2 O 5 cathodes in lithium cells.

25 ENERGY STORAGE↗

Composite Ionogel Electrodes for Polymeric Solid-State Li-Ion Batteries

Realizing rechargeable cells with practical energy and power density requires electrodes with high active material loading, a remaining challenge for solid-state batteries. Here, we present a new strategy based on ionogel-derived solid-state electrolytes (SSEs) to form composite electrodes that enable high active material loading (>10 mg/cm 2 , ~9 mA/cm 2 at 1C) in a scalable approach for fabricating Li-ion cells. By tuning the precursor and active materials composition incorporated into the composite lithium titanate electrodes, we achieve near-theoretical capacity utilization at C/5 rates and cells capable of stable cycling at 5.85 mA/cm 2 (11.70 A/g) with over 99% average Coulombic efficiency at room temperature. Finally, we demonstrate a complete polymeric solid-state cell with a composite anode and a composite lithium iron phosphate cathode with ionogel SSEs, which is capable of stable cycling at a 1C rate.

25 ENERGY STORAGE↗

Advancing Concentrating Solar Thermal Modeling Using System Advisor Model (SAM)

Concentrating solar thermal (CST) technologies play a critical role in enabling dispatchable power and high-temperature industrial heat applications. Accurate and flexible modeling tools are essential for evaluating system performance, guiding technology research and development, and informing investment decisions. The National Laboratory of the Rockies's System Advisor Model (SAM) is a widely used techno-economic simulation platform for CST systems, providing detailed performance and financial modeling capabilities for multiple CST system configurations. SAM integrates physics-based performance models with financial analysis to simulate the behavior of complex energy systems under realistic operating conditions. For CST technologies (including tower, parabolic trough, and linear Fresnel), SAM enables hourly simulations using site-specific weather data that ensure feasible operating conditions and convergence of mass and energy between core system components (i.e., solar field, receiver, thermal energy storage, and power cycle). These capabilities allow researchers and developers to evaluate annual energy production, capacity factors, levelized cost of energy (LCOE), and system dispatch strategies. A key advantage of SAM lies in its flexibility for parametric analysis and large-scale computational studies. Users can vary system design parameters such as heliostat field layout, receiver dimensions, thermal energy storage capacity, power block sizing, and installation cost assumptions to investigate their impact on system performance and financial metrics. When combined with automated scripting through LK, SDKTool, or Python interfaces, SAM enables high-throughput simulation workflows that support sensitivity analysis, technology benchmarking, and optimization studies. These approaches are particularly valuable for next-generation CST concepts, where design spaces are large and system interactions are complex. Another important capability of SAM is its support for dispatch optimization and thermal energy storage modeling, which are central to the value proposition of CST technologies. The ability to simulate integrated storage and flexible power generation allows researchers to explore strategies that maximize grid value, improve capacity utilization, and enhance integration with variable resources such as photovoltaic and wind generation. This poster will present an overview of SAM's thermal system modeling capabilities including concentrating solar. Additionally, we will highlight new feature developments including: 1) implementing Google's OR-Tools optimization platform for faster and more robust dispatch optimization, 2) developing a new power load following controller for modeling behind-the-meter applications, 3) enabling direct modeling of CSP-PV hybrid systems with the inclusion of battery storage, and 4) developing a multi-receiver falling particle Gen3 system model.

14 SOLAR ENERGY↗

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY↗

Manufacturing Thermal Energy Use in 2014

The first data set estimates thermal energy use (i.e., fuels combusted for process heating, boilers, and combined heat and power/cogeneration) by end use, temperature, county, and facility employment size class for all U.S. manufacturing industries in 2014. The estimation methodology builds off of prior estimates of industrial energy use (https://dx.doi.org/10.7799/1481899, https://dx.doi.org/10.7799/1461488). The second data set estimates hourly heat load (as a fraction of annual energy used for heat) using hourly observations of industrial boiler and combined heat and power/cogeneration heat load from EPA's Air Markets Program Data (https://ampd.epa.gov/ampd/), weekly operating hours in 2014 from Census Quarterly Survey of Plant Capacity Utilization (https://www.census.gov/programs-surveys/qpc/data.html), and annual production hours reported by assessments conducted by Industrial Assessment Centers (https://iac.university/).

14 SOLAR ENERGY↗

Manufacturing Thermal Energy Use in 2014

The first data set estimates thermal energy use (i.e., fuels combusted for process heating, boilers, and combined heat and power/cogeneration) by end use, temperature, county, and facility employment size class for all U.S. manufacturing industries in 2014. The estimation methodology builds off of prior estimates of industrial energy use (https://dx.doi.org/10.7799/1481899, https://dx.doi.org/10.7799/1461488). The second data set estimates hourly heat load (as a fraction of annual energy used for heat) using hourly observations of industrial boiler and combined heat and power/cogeneration heat load from EPA's Air Markets Program Data (https://ampd.epa.gov/ampd/), weekly operating hours in 2014 from Census Quarterly Survey of Plant Capacity Utilization (https://www.census.gov/programs-surveys/qpc/data.html), and annual production hours reported by assessments conducted by Industrial Assessment Centers (https://iac.university/).

14 SOLAR ENERGY↗

Channel capacity of Moore automata.

Algorithm for calculating Moore automaton or connected network channel capacity and source of input symbols for full capacity utilization

Conant, R. C.↗

Pricing of NASA Space Shuttle transportation system cargo

A two-part pricing policy is investigated as the most feasible method of pricing the transportation services to be provided by NASA's SSTS. Engineering cost estimates and a deterministic operating cost model generate a data base and develop a procedure for pricing the services of the SSTS. It is expected that the SSTS will have a monopoly on space material processing in areas of crystal growth, glass processing, metallurgical space applications, and biomedical processes using electrophoresis which will require efficient pricing. Pricing problems, the SSTS operating costs based on orbit elevation, number of launch sites, and number of flights, capital costs of the SSTS, research and development costs, allocation of joint transportation costs of the SSTS to a particular space processing activity, and rates for the SSTS are discussed. It is concluded that joint costs for commercial cargoes carried in the SSTS can be most usefully handled by making cost allocations based on proportionate capacity utilization.

Hale, C. W.↗

75 Ah and 10 boilerplate nickel-hydrogen battery designs and test results

The results of initial characterization testing of 75 Ah actively cooled bipolar battery designs and 10 boilerplate nickel-hydrogen battery designs are presented. The results demonstrate the extended cycle life capability of the Ah batteries and the high capacity utilizations at various discharge rates of the nickel-hydrogen batteries.

Daman, M. E.↗

Simple Tool for Aircraft Noise-Reduction Route Design

The design of arrival and departure routes from an airport has to balance the conflicting requirements of fuel efficiency, airport capacity utilization and community emission and noise considerations. The commonly used tools for aircraft noise assessment are the FAA’s Integrated Noise Model (INM) and Aviation Environmental Design Tool (AEDT). These tools are suitable to generate precise noise contours. However, they are harder to use with other tools for route design optimization involving evaluation of a large number of aircraft trajectories. A simplified aircraft noise computation tool, named AIRNOISE, is developed for preliminary aircraft noise-reduction route design in this paper. AIRNOISE computes aircraft noise based on the same SAE-AIR-1845 procedures used by INM and AEDT. AIRNOISE does not consider components related to terrain and atmosphere adjustments. As a result, it is not only computationally efficient but also flexible to use for customized aircraft profiles. The aircraft noise results are compared with the FAA’s AEDT2b and show that the level of accuracy achieved by AIRNOISE can be used to reduce the number of route design options to a small number from a large pool for subsequent accurate analysis by INM.

Li, Jinhua↗

Optimized Route Capability (ORC) Intelligent Offloading of Congested Arrival Routes

The Optimized Route Capability (ORC) concept is designed to enable intelligent offloading of congested arrival routes. When ORC predicts arrival route congestion as projected excess arrival meter fix delay, automation offers decision support to traffic managers by identifying candidate flights to strategically reroute to alternate meter fixes and alleviate the congestion. This concept was applied to a model of arrival operations into Houston International Airport. An arrival rush from the Northeast was simulated in fast-time to analyze ORC algorithm behavior. The results demonstrate how strategically rerouting a few flights to alternate meter fixes not only has the potential to manage meter fix delay (and possibly the need for traffic management initiatives applied upstream), but may also increase airport capacity utilization and reduce total flight delay.

Zelinski, Shannon↗

Tailored Arrival Manager Plan for ecoD 2020

TAM is an automated approach to ensuring safe separation while maximizing throughput and efficiency; as currently conceived, it would serve as an ATC tool. TAM relies on NASA’s Autoresolver technology to compute trajectory-based arrival solutions that provide separation assurance while maximizing airspace and airport capacity utilization. In addition, TAM enables optimized profile descents that minimize altitude level offs and speed interruptions. Importantly, TAM trajectory clearances are intended for delivery to the flight deck through datacomm rather than voice-based communications. Once received on the flight deck, TAM solutions can be auto-loaded into a Flight Management System (FMS) for precision guidance and control along the intended arrival trajectory.

Richard A Coppenbarger↗

Distributed Power Flow Control: Distributed Power Flow Control using Smart Wires for Energy Routing

GENI Project: Smart Wire Grid is developing a solution for controlling power flow within the electric grid to better manage unused and overall transmission capacity. The 300,000 miles of high-voltage transmission line in the U.S. today are congested and inefficient, with only around 50% of all transmission capacity utilized at any given time. Increased consumer demand should be met in part with more efficient and an economical power flow. Smart Wire Grid’s devices clamp onto existing transmission lines and control the flow of power within—much like how internet routers help allocate bandwidth throughout the web. Smart wires could support greater use of renewable energy by providing more consistent control over how that energy is routed within the grid on a real-time basis. This would lessen the concerns surrounding the grid’s inability to effectively store intermittent energy from renewables for later use.

ARPA-E↗

Managing time-substitutable electricity usage using dynamic controls

A predictive-control approach allows an electricity provider to monitor and proactively manage peak and off-peak residential intra-day electricity usage in an emerging smart energy grid using time-dependent dynamic pricing incentives. The daily load is modeled as time-shifted, but cost-differentiated and substitutable, copies of the continuously-consumed electricity resource, and a consumer-choice prediction model is constructed to forecast the corresponding intra-day shares of total daily load according to this model. This is embedded within an optimization framework for managing the daily electricity usage. A series of transformations are employed, including the reformulation-linearization technique (RLT) to obtain a Mixed-Integer Programming (MIP) model representation of the resulting nonlinear optimization problem. In addition, various regulatory and pricing constraints are incorporated in conjunction with the specified profit and capacity utilization objectives.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Managing time-substitutable electricity usage using dynamic controls

A predictive-control approach allows an electricity provider to monitor and proactively manage peak and off-peak residential intra-day electricity usage in an emerging smart energy grid using time-dependent dynamic pricing incentives. The daily load is modeled as time-shifted, but cost-differentiated and substitutable, copies of the continuously-consumed electricity resource, and a consumer-choice prediction model is constructed to forecast the corresponding intra-day shares of total daily load according to this model. This is embedded within an optimization framework for managing the daily electricity usage. A series of transformations are employed, including the reformulation-linearization technique (RLT) to obtain a Mixed-Integer Programming (MIP) model representation of the resulting nonlinear optimization problem. In addition, various regulatory and pricing constraints are incorporated in conjunction with the specified profit and capacity utilization objectives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Managing time-substitutable electricity usage using dynamic controls

A predictive-control approach allows an electricity provider to monitor and proactively manage peak and off-peak residential intra-day electricity usage in an emerging smart energy grid using time-dependent dynamic pricing incentives. The daily load is modeled as time-shifted, but cost-differentiated and substitutable, copies of the continuously-consumed electricity resource, and a consumer-choice prediction model is constructed to forecast the corresponding intra-day shares of total daily load according to this model. This is embedded within an optimization framework for managing the daily electricity usage. A series of transformations are employed, including the reformulation-linearization technique (RLT) to obtain a Mixed-Integer Programming (MIP) model representation of the resulting nonlinear optimization problem. In addition, various regulatory and pricing constraints are incorporated in conjunction with the specified profit and capacity utilization objectives.

Ghosh, Soumyadip↗

Modelling and Experimental Validation of Improved Performance of Lithium-Ion Batteries Having Thick Electrodes with Laser-Ablated Micro-Structures

For widespread adoption of electric vehicles, lithium-ion batteries (LiBs) need to achieve energy densities of >275 Wh/kg, cost less than $100/Wh, and charge to more than 80% capacity within 15 minutes. Increasing the battery electrode thicknesses is one way to increase cell energy densities while also saving on cell manufacturing cost by increasing the ratio of electrode active material to inactive material within each cell. However, increased electrode loading is often accompanied by decreased Li+-ion diffusion across the full thick electrodes. This leads to significant cell polarization that prevents full capacity utilization and accelerates cell degradation, especially at fast charging/discharging rates. The introduction of secondary pore networks in thick battery electrodes alleviates some of the trade-offs between energy and power performance. These microstructures provide low tortuosity pathways for facile Li+-ion diffusion deep into the thick electrodes, diminishing detrimental concentration gradients within the cell. Ultrafast-pulsed laser ablation is a promising method to introduce micro pores or channels in thick battery electrodes as it allows for precise control of pattern geometries, results in minimal damage to the electrode and can be introduced into existing roll-to-roll electrode manufacturing lines. Herein, the limitations of thick planer electrodes and the advanced predictive models to identify optimal electrode patterns for improved cycling performance will be presented. The impact of electrode laser patterning to create secondary pore networks also will be discussed. Materials characterization techniques (SEM-EDS, XRD) were used to explore the affect ultrafast laser ablation had on the electrode materials’ morphology and structure. The improvements in the patterned electrodes’ electrochemical cycling performances and degrees of wetting will be compared to a pristine baseline case. Finally, the discrepancies between experimentally obtained data and model predictions will be explained.

DIRECT ENERGY CONVERSION,ENERGY STORAGE↗