At least 73 records · Page 4

Design and Evaluation of a Tethered, Open Port Sampling Interface for Liquid Extraction-Mass Spectrometry Chemical Analysis

Presented in this work is a tethered, liquid-extraction-sampling interface designed for the mass spectrometric surface sampling/analysis of 3D objects. The tethered, open port sampling interface (TOPSI) incorporates a vacuum line between the sampling probe and ionization source, which enables the ability for an extended, tethered sample transfer line. Herein, several designs of the hand-held TOPSI are presented and evaluated on the basis of the analytical metrics of analyte transport time, peak width, and analyte sensitivity. The best analytical metrics were obtained with capillary flow resistances arranged in a particular order and the vacuum region set at 6.2 kPa. This TOPSI design incorporated a transfer capillary 1 m in length, while retaining a fast analyte transport time (12 s), short signal peak width (5 s baseline-to-baseline), and high analyte signal at 90% of that obtained with a regular open port sampling interface (OPSI). The hand-held TOPSI was demonstrated for the characterization of extracted small molecules and metabolites from the surface of mint and rosemary leaves.

47 OTHER INSTRUMENTATION↗

Tolerance requirements to prevent fluid leakage in the crucible/plunger MEA experiment MPS 770030

Molten Al-In leaked unexpectedly out of the crucible of a proposed MEA materials processing in space experiment. The molten metals use a spring loaded plunger to eliminate most free surfaces. The critical criteria necessary to initiate flow and the rate of fluid flow into the crucible/plunger annulus is calculated. Experimental in situ X-radiographs are interpreted according to the calculations. A note on possible effects of capillary flow if wetting occurs between crucible/plunger and liquids is included.

Rathz, T. J.↗

Acoustic Insights into Flow Condensation Mechanisms

Two-phase thermal management systems, with both boiling and condensation processes, offer great potential and heat transfer coefficients that are orders of magnitude higher than traditional single-phase systems. However, two-phase flows can suffer from a wide range of interfacial instabilities leading to significant thermal performance degradation. In this study, we aim to detect regime transitions and characterize dominating physical mechanisms of flow condensation, such as turbulent diffusion in annular liquid film and interfacial waves, using an integrated system of acoustic, modal, and optical sensing techniques and thermofluidic characterizations. A wideband acoustic emissions sensor and high-sensitivity accelerometer are utilized to capture acoustic and vibrational signatures that signal the onset of liquid film formation and interfacial waves during flow pattern transitions. Compared to optical imaging, wideband acoustic emission sensing allows for higher sampling rates to capture high-frequency interface oscillations critical to the flow regime transitions and works well even for condensation in opaque tubes. Acoustic features (e.g., amplitude, frequency, energy, duration) are correlated with thermofluidic processes (e.g., capillary flows, turbulent flows, boiling, condensation). By relating thermal performance metrics with these dynamic signatures in acoustic and modal regimes, we explore the ability to probe and monitor critical flow regime transitions and transport efficiency in flow condensation.

Acoustic Modal Regimes↗

An All Hydrophilic Fluid Diode for Unidirectional Flow in Porous Systems

Abstract A fluid diode that allows fluid flow in one direction but blocks fluid flow in the opposite direction has wide applications including oil recovery, drug delivery, and lab‐on‐a‐chip microfluidics. Many studies are conducted to facilitate directional liquid motion on the solid surface or across thin porous layers. However, the self‐driven one‐way flow inside porous systems still remains a significant challenge. Here, a novel all‐hydrophilic fluid diode (AHFD) made of porous materials with asymmetric pores is reported, which allows capillary flow in a chosen direction. The direction‐dependent flow process and the breakthrough pressure are experimentally and theoretically examined. The proposed AHFD can have many potential applications such as functional protective clothing, microfluidic valve, and oil–water separator, and the idea can be extended to develop other all lyophilic fluid diodes such as oleophilic diode.

Shou, Dahua↗

Vibration isolation technology: Sensitivity of selected classes of space experiments to residual accelerations

Progress performed on each task is described. Order of magnitude analyses related to liquid zone sensitivity and thermo-capillary flow sensitivity are covered. Progress with numerical models of the sensitivity of isothermal liquid zones is described. Progress towards a numerical model of coupled buoyancy-driven and thermo-capillary convection experiments is also described. Interaction with NASA personnel is covered. Results to date are summarized and they are discussed in terms of the predicted space station acceleration environment. Work planned for the second year is also discussed.

Alexander, J. Iwan D.↗

Self-Healing Technologies for Wiring and Surfaces in Aerospace and Deep Space Exploration Applications

Self-healing technologies have been identified as critical technology gaps for future exploration. NASA and KSC have been working in this area for multiple years with established intellectual property; however, there are many challenges that remain in this area of research. How do we mimic what the body does so naturally when we as NASA have unique requirements? We have been investigating several mechanisms for self-healing: microencapsulation with a healant core to fill in voids in the case of mechanical puncture and flowable (or sealable)systems that have inherent chemical properties that allow the materials to flow back together when cut or damaged. The microcapsules containing healant have to be durable and robust, must be able to take high temperatures to meet NASA unique requirements, provide good capillary flow of the healant, and be small in diameters to fill in damage voids in thin films or surfaces. Sealable systems have to flow in a range of temperatures and yet be lightweight and chemically resistant. The systems currently being developed are based on polyimide and polyurethane matrices and have been studied for use in high performance wiring systems, inflatable systems, and habitation structures. Self-healing or self-sealing capability would significantly reduce maintenance requirements and increase the safety and reliability performance of critical systems. Advances in these self-healing technologies and some of the unique challenges needed to be overcome in order to incorporate a self-healing mechanism into wiring or thin films systems will be addressed.

Self-healing technologies↗

Integrity of Polymethylmethacrylate (PMMA) Chemically Welded Joints Examined

NASA Glenn Research Center s Capillary Flow Experiments (CFE) program is developing experiment payloads to explore fluid interfaces in microgravity on the International Space Station. The information to be gained from the CFE is relevant to the design of fluid-bearing systems in which capillary forces predominate, for example in the passive positioning of liquids in spacecraft fuel tanks. To achieve the science goals of CFE, Glenn researchers constructed several types of experiment vessels. One type of vessel, known as the interior corner flow (ICF), will be used to determine important transients for low-gravity liquid management in a two-phase system. Each vessel has a cylindrical fluid reservoir connected to each end of the test chamber by internal transport tubes, each with a quarter-turn shutoff valve (see the following photograph). These multipiece vessels are made from polymethylmethacrylate (PMMA) because of its excellent optical properties (i.e., the fluids can be observed easily in the vessel). Because of the complexity of certain vessels, the test chamber had to be manufactured in pieces and welded chemically. Some past experience with adhesive bonded plastic showed that the experiment fluid degraded the adhesive to the point of failure. Therefore, it was necessary to see if the fluid also degraded the chemically welded PMMA joints.

Lerch, Bradley A.↗

Lithium Divertor Targets and Walls for the ASTER Liquid Stellarator Reactor, Distributed Divertor

Stellarators may have advantages for certain liquid metal options as Plasma Facing Components (PFC) for divertor targets and first walls due to the wide range of possible magnetic configurations, which additionally are free of disruptions and fast field variations. In a previous work (V. Queral et al., IEEE Trans. Plasma Sci. 52, 2024), a concept of stellarator reactor (ASTER-CP) based on swirling Li-molten salts and liquid lithium floating on the molten salt as PFC was presented. The divertor matters were not studied then and, thus, they are being studied and experimentally tested now. The ASTER-CP reactor concept, the initial liquid metal experiments and potential concepts for the ASTER-CP divertor and first wall are reported. Concerning the experiments, several small scale experiments of galinstan in a small rotating cylinder under magnetic field have been produced, including one experiment with high viscosity galinstan-mixture for increased thickness of layer. An experiment of floating lithium on the molten salt LiCl-PbCl2 gave fast volatilization/decomposition of the molten salt. Particularly for divertors, the traditional free-flow, Capillary Porous Systems and ‘divertorlets’ have been studied for application to ASTER-CP. Surface waves (hot spots), lack of enough surface fluid turbulence and excessive fluid speed are the main issues found in fast free-flow. The perhaps original concept of Distributed Divertor and Equi-power Surface is tentatively proposed and studied, taking advantage of stellarator fields and low recycling regime.

distributed divertor↗

Capillary movement of liquid in granular beds in microgravity

A more complete understanding of the dynamics of capillary flow through an unsaturated porous medium would be useful for the development of an effective water and nutrient delivery system for the growth of plants in space. An experiment was conducted on the Mir Space Station that used an experimental cuvette called "Capillary Test Bed" to compare fluid migration under terrestrial laboratory conditions by positioning the cuvette such that the hydrostatic force is negated and on Mir under microgravity conditions. Differences in fluid migration in the cuvette were observed with migration being slower in microgravity compared with some ground control experiments.

Mir Project↗

Capillary Movement of Liquid in Granular Beds in Microgravity

A more complete understanding of the dynamics of capillary flow through an g unsaturated porous medium would be useful for a number of space and terrestrial applications. One such application involves the development of an effective water and nutrient delivery system for the growth of plants in space. An experiment was conducted on the Mir Space Station that used an experimental cuvette called "Capillary Test Bed". An objective of this experiment was to compare fluid migration in the "Capillary Test Bed" under terrestrial laboratory simulated microgravity conditions by positioning the cuvette such that the hydrostatic force is negated and on Mir at microgravity conditions. Difference in fluid migration in the cuvette were observed. Based on these observations, improvements in the design of the cuvette are under-way that should allow for collection of more precise data in future flight experiments. The results of the MIR experiment and modifications being made to the cuvette for improved data collection will be discussed.

Yendeler, Boris S.↗

Terrestrial Testing of the CapiBRIC, a Microgravity Optimized Brine Processor

Utilizing geometry based static phase separation exhibited in the radial vaned capillary drying tray, a system was conceived to recover water from brine. This technology has been named the Capillary BRIC; abbreviated CapiBRIC. The CapiBRIC utilizes a capillary drying tray within a drying chamber. Water is recovered from clean water vapor evaporating from the free surface leaving waste brine solids behind. A novel approach of optimizing the containment geometry to support passive capillary flow and static phase separation provides the opportunity for a low power system that is not as susceptible to fouling as membranes or other technologies employing physical barriers across the free brine surface to achieve phase separation in microgravity. Having been optimized for operation in microgravity, full-scale testing of the CapiBRIC as designed cannot be performed on the ground as the force of gravity would dominate over the capillary forces. However, subscale units relevant to full-scale design were used to characterize fill rates, containment stability, and interaction with a variable volume reservoir in the PSU Dryden Drop Tower (DDT) facility. PSU also using tested units scaled such that capillary forces dominated in a 1-g environment to characterize evaporation from a free-surface in 1-g upward, sideways and downward orientations. In order to augment the subscale testing performed by PSU, a full scale 1-g analogue of the CapiBRIC drying unit was initiated to help validate performance predictions regarding expected water recovery ratio, estimated processing time, and interface definitions for inlets, outlets, and internal processes, including vent gas composition. This paper describes the design, development and test of the terrestrial CapiBRIC prototypes.

Sargusingh, Miriam J.↗

Measurement of Resistance, Porosity, and Water Contact Angle of Porous Transport Layers for Low-Temperature Electrolysis Technologies

The porous transport layer is an important component of low-temperature electrolysis devices, such as proton exchange membrane water electrolyzers or anion exchange membrane water electrolyzers. PTLs have significant influence on the cell performance as their bulk resistance can impact the ohmic resistance, their contact resistance can impact electrode performance, and their structure can impact the liquid flow to the cell, which could cause mass-transport losses. In order to improve cell performance, optimization of the PTL is critical. Standardized protocols should be utilized to adequately compare PTLs being developed from different institutions. This method will detail a standardized protocol for measuring the resistance of the PTL using a four-wire setup and will also detail a process for measuring the porosity and water contact angle of the PTL using capillary flow porometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Blood Plasma Self-Separation Technologies during the Self-Driven Flow in Microfluidic Platforms

Blood plasma is the most commonly used biofluid in disease diagnostic and biomedical analysis due to it contains various biomarkers. The majority of the blood plasma separation is still handled with centrifugation, which is off-chip and time-consuming. Therefore, in the Lab-on-a-chip (LOC) field, an effective microfluidic blood plasma separation platform attracts researchers’ attention globally. Blood plasma self-separation technologies are usually divided into two categories: active self-separation and passive self-separation. Passive self-separation technologies, in contrast with active self-separation, only rely on microchannel geometry, microfluidic phenomena and hydrodynamic forces. Passive self-separation devices are driven by the capillary flow, which is generated due to the characteristics of the surface of the channel and its interaction with the fluid. Comparing to the active plasma separation techniques, passive plasma separation methods are more considered in the microfluidic platform, owing to their ease of fabrication, portable, user-friendly features. We propose an extensive review of mechanisms of passive self-separation technologies and enumerate some experimental details and devices to exploit these effects. The performances, limitations and challenges of these technologies and devices are also compared and discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Dean vortex-enhanced blood plasma separation in self-driven spiral microchannel flow with cross-flow microfilters

Point-of-care (POC) diagnostic devices have been developing rapidly in recent years, but they are mainly using saliva instead of blood as a test sample. A highly efficient self-separation during the self-driven flow without power systems is desired for expanding the point-of-care diagnostic devices. Microfiltration stands out as a promising technique for blood plasma separation but faces limitations due to blood cell clogging, resulting in reduced separation speed and efficiency. These limitations are mainly caused by the high viscosity and hematocrit in the blood flow. A small increment in the hematocrit of the blood significantly increases the pressure needed for the blood plasma separation in the micro-filters and decreases the separation speed and efficiency. Addressing this challenge, this study explores the feasibility of diluting whole blood within a microfluidic device without external power systems. This study implemented a spiral microchannel utilizing the inertial focusing and Dean vortex effects to focus the red blood cells and extract the blood with lower hematocrit. The inertial migration of the particles during the capillary flow was first investigated experimentally; a maximum of 88% of the particles migrated to the bottom and top equilibrium positions in the optimized 350 × 60 μm (cross-sectional area, 5.8 aspect ratio) microchannel. With the optimized dimension of the microchannel, the whole blood samples within the physiological hematocrit range were tested in the experiments, and more than 10% of the hematocrit reduction was compared between the outer branch outlet and inner branch outlet in the 350 × 60 μm microchannel.

Biochemistry & Molecular Biology↗

A Study of the Constrained Vapor Bubble Thermosyphon

The objective of this effort is to better understand the physics of evaporation, condensation, and fluid flow as they affect the heat transfer processes in a constrained vapor bubble heat exchanger (CVBHX). This CVBHX consists of a small enclosed container with a square cross section (inside dimensions. 3 x 3 x 40 mm) partially filled with a liquid. The major portion of the liquid is in the corners, which act as arteries. When a temperature difference is applied to the ends of the CVBHX, evaporation occurs at the hot end and condensation at the cold end resulting in a very effective heat transfer device with great potential in space applications. Liquid is returned by capillary flow in the corners. A complete description of the system and the results obtained to date are given in the papers listed.

Wayner, Peter C., Jr.↗

The effects of gas-fluid-rock interactions on CO2 injection and storage: Insights from reactive transport modeling

Possible means of reducing atmospheric CO{sub 2} emissions include injecting CO{sub 2} in petroleum reservoirs for Enhanced Oil Recovery or storing CO{sub 2} in deep saline aquifers. Large-scale injection of CO{sub 2} into subsurface reservoirs would induce a complex interplay of multiphase flow, capillary trapping, dissolution, diffusion, convection, and chemical reactions that may have significant impacts on both short-term injection performance and long-term fate of CO{sub 2} storage. Reactive Transport Modeling is a promising approach that can be used to predict the spatial and temporal evolution of injected CO{sub 2} and associated gas-fluid-rock interactions. This presentation will summarize recent advances in reactive transport modeling of CO{sub 2} storage and review key technical issues on (1) the short- and long-term behavior of injected CO{sub 2} in geological formations; (2) the role of reservoir mineral heterogeneity on injection performance and storage security; (3) the effect of gas mixtures (e.g., H{sub 2}S and SO{sub 2}) on CO{sub 2} storage; and (4) the physical and chemical processes during potential leakage of CO{sub 2} from the primary storage reservoir. Simulation results suggest that CO{sub 2} trapping capacity, rate, and impact on reservoir rocks depend on primary mineral composition and injecting gas mixtures. For example, models predict that the injection of CO{sub 2} alone or co-injection with H{sub 2}S in both sandstone and carbonate reservoirs lead to acidified zones and mineral dissolution adjacent to the injection well, and carbonate precipitation and mineral trapping away from the well. Co-injection of CO{sub 2} with H{sub 2}S and in particular with SO{sub 2} causes greater formation alteration and complex sulfur mineral (alunite, anhydrite, and pyrite) trapping, sometimes at a much faster rate than previously thought. The results from Reactive Transport Modeling provide valuable insights for analyzing and assessing the dynamic behaviors of injected CO{sub 2}, identifying and characterizing potential storage sites, and managing injection performance and reducing costs.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Porous Transport Layers Towards the Development of Efficient Proton Exchange Membrane Water Electrolysis

The current goals for implementing the hydrogen economy have highlighted a need to further optimize water-splitting technologies for clean hydrogen production. Proton exchange membrane water electrolysis (PEMWE) is a leading technology, but further optimizations of anode materials including the porous transport layer (PTL) and the adjacent catalyst layer (CL) are required to increase overall cell performance and reduce cost. This literature review describes advances in PTL development and characterization, highlighting early PTL characterization work and most common methods including capillary flow porometry and mercury intrusion porometry, optical imaging, neutron and x-ray radiography, and x-ray computed tomography. The article also discusses PTL protective coatings and their characterizations, focusing on platinum group metal (PGM)-based coatings, alternative non-PGM-based coatings, post-treated PTLs, and investigations into thin PGM-based coatings. Furthermore, it highlights the integration of the PTL and the adjacent CL along with associated characterization challenges. Lastly, this review discusses future developments in the characterization needed to improve PEMWE's performance and long-term durability are discussed.

08 HYDROGEN↗

Quantifying root water extraction after drought recovery using sub-mm in situ empirical data

Root-specific responses to stress are not well-known, and have been largely based on indirect measurements of bulk soil water extraction, which limits mechanistic modeling of root function. Here, we used neutron radiography to examine in situ root-soil water dynamics of a previously droughted black cottonwood ( Populus trichocarpa ) seedling, contrasting water uptake by younger, thinner or older, thicker parts of the fine root system. The smaller diameter roots had greater water uptake capacity per unit surface area than the larger diameter roots, but they had less total surface area leading to less total water extraction; rates ranged from 0.0027 – 0.0116 g cm -2 hr -1 . The finest most-active roots were not visible in the radiographs, indicating the need to include destructive sampling. Analysis based on bulk soil hydraulic properties indicated substantial redistribution of water via saturated/unsaturated flow, capillary wicking, and root hydraulic redistribution across the layers - suggesting water uptake dynamics following an infiltration event may be more complex than approximated by common soil hydraulic or root surface area modeling approaches. Lastly, our results highlight the need for continued exploration of root-trait specific water uptake rates in situ, and impacts of roots on soil hydraulic properties – both critical components for mechanistic modeling of root function.

59 BASIC BIOLOGICAL SCIENCES↗