Search NASASearch

SEARCH · Search NASA

Results for “case study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Optimizing district energy systems under uncertainty: Insights from a case study from Washington D.C., USA

This study investigates solutions for delivering affordable heating and cooling to a brownfield site, focusing on a case study in Washington, DC. Moving towards more diverse and resilient energy systems, we identify the optimal portfolio for a district energy system with diverse energy sources to meet the area’s energy demands. Our methodological approach integrates two detailed models: one calculating building-level energy demand and the other optimizing district energy technology choices based on their demand profiles, accounting for uncertainties in energy prices, policies, and other parameters. The results provide an economic comparison of district and individual supply options at the building level, emphasizing the flexibility district systems can offer to the electricity sector. District energy systems demonstrate cost-stabilization benefits amidst volatile energy prices and external uncertainties. For heating, district systems yield significant cost savings compared to individual solutions, driven by fuel flexibility and the use of local renewable energy sources. For cooling, district systems also show advantages, though individual systems may remain more cost-effective for smaller buildings. Additionally, district systems exhibit considerable flexibility on the heating side, as evidenced by variations in electricity consumption. We recommend future research to explore the relationship between the economics of district energy systems, particularly at the building level, and their flexibility potential for the electricity sector across diverse geographic contexts to reduce overall grid costs and promote grid reliability. This includes areas with distinct zoning laws, municipal priorities, utility structures, and funding mechanisms, such as the United States, and regions like Europe with pronounced electricity price volatility.

24 POWER TRANSMISSION AND DISTRIBUTION

Geothermal Heat Pump Case Study: Seattle Public Schools

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on Seattle Public Schools and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

geothermal

Geothermal Heat Pump Case Study: The Inn on Boltwood

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on The Inn on Boltwood and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

geothermal

Geothermal Heat Pump Case Study: Westwood Hills Nature Center

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on Westwood Hills Nature Center and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

geothermal

Geothermal Heat Pump Case Study: The Town at Trilith

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on The Town at Trilith and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

15 GEOTHERMAL ENERGY

Geothermal Heat Pump Case Study: Berkeley County School District

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on Berkeley County School District and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

15 GEOTHERMAL ENERGY

Affordable and Scalable Modular Multifamily Housing: A Case Study on Cost, Construction Time Savings, and Waste Reduction in California: Preprint

Modular construction can significantly reduce waste when compared to traditional methods. This case study evaluates cost, construction time, and waste metrics for a 195-unit stick-built project and for a 66-unit modular project both based in Los Angeles, CA. We partner with SoLa Impact (real estate developer) and Model/Z (modular manufacturer) to evaluate the impact of Model/Z's 1-bedroom modular unit which is produced in a 160,000 sq ft local factory in South Los Angeles. We compare them to similar stick-built/site-built multifamily construction by the same developer in Los Angeles. This study finds that modular production reduced construction waste through precise prefabrication, concentrated workforce expertise, and streamlined logistics while cutting transportation needs, improving project efficiency and lowering associated timelines and costs. Economies of scale are being realized as Model/Z has produced over 500 affordable housing units and supplied for projects up to 188 units, shortening schedules and lowering per-unit costs and supporting affordable housing goals in income-challenged South Los Angeles. Modular methods offer a scalable, resource-efficient pathway to increasing affordable housing supply while reducing total development costs by 10-15% and project timelines by 50%, while simultaneously creating local jobs and training opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Case Study: Leveraging GenAI to Build AI-based Surrogates and Regressors for Modeling Radio Frequency Heating in Fusion Energy Science

This work presents a detailed case study on using Generative AI (GenAI) to develop AI surrogates for simulation models in fusion energy research. The scope includes the methodology, implementation, and results of using GenAI to assist in model development and optimization, comparing these results with previous manually developed models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Geothermal Heat Pump Case Study: PCC Austin Family Health Center

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on PCC Austin Family Health Center and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

geothermal

Geothermal Heat Pump Case Study: University of North Carolina Asheville

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on University of North Carolina Asheville and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

geothermal

Geothermal Heat Pump Case Study: Central New Mexico Community College

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on Central New Mexico Community College and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

15 GEOTHERMAL ENERGY

Extending Shared Socioeconomic Pathways to Future Water Supply In-frastructure Scenarios: A Case Study of San Antonio, TX

Datasets supporting findings and visualization behind Okoye and McManamay (2025) Extending Shared Socioeconomic Pathways to Future Water Supply Infrastructure Scenarios: A Case Study of San Antonio, TX. Environmental Research Communications, DOI: 10.57931/2563186 These datasets contains the results of a site selection analysis for municipal water supply planning across multiple Shared Socioeconomic Pathways (SSPs 1–5) and hard scenario classification of water systems in San Antonio, TX. It includes data at the resolution of individual surface water supply sources (COMIDs) and integrates a wide range of hydrologic, socioeconomic, infrastructural, and scenario-based planning variables. Please refer to the README file provided in Files for more details. Descriptions of the datasets are provided below. Dataset(s) Descriptions: Dataset_SSP1_SSP4.xlsx - Contains data used for site selection optimization under SSP1 to SSP4. This dataset was generated based on multi-indicator computations (e.g., WAI, WQI, ERI, WTC, WIC), scenario demand projections, and resource and spatial constraints, excluding new reservoir values. Dataset_SSP5.xlsx - Used for site optimization under SSP5. Unlike Dataset_SSP1_SSP4, this dataset includes new reservoir features with updated calculations of WAI, WTC, and WIC to reflect the added infrastructure and supply potential. hard_classification.xlsx - Provides the scenario classification output for each site. Includes both the initial scenario classification based on Euclidean Distance and adjusted classifications based on 30% change reduction BAU.zip - Zipped folder of .shp files showing spatially optimized water supply sites per SSP under the Business-As-Usual (BAU) water demand strategy LowGW.zip - Zipped folder of .shp files showing optimized site selections under the Low Groundwater strategy

geospatial

Data-model files associated with the manuscript "Modeling the Effects of Wetland Restoration on Coastal Hydrology: A Case Study of Elkhorn Slough Watershed, California"

This package contains the data, simulation setups, notebooks and figures used in “Modeling the Effects of Wetland Restoration on Coastal Hydrology: A Case Study of Elkhorn Slough Watershed, California” (Xu et al., 2025). In this study, we selected Elkhorn Slough, a tidal estuary, in California, to investigate the impact of wetland restoration and sea level rise on coastal hydrology using the process-based coastal hydrologic model, Advanced Terrestrial Simulator (ATS), informed by site-specific data. We designed a novel modeling workflow for incorporating wetland restoration features into land cover and soil properties for the model parameterization. The validation results demonstrate a strong agreement between modeled and observed data. We studied the characteristics of coastal watershed hydrology, then focused on the surface water dynamics at two wetland sites within Elkhorn Slough, a reference site and a restored site. Our simulation results indicate that the restored site successfully maintains surface elevation, resulting in reduced surface inundation. We also examined the impact of wetland restoration under expected sea level rise over the next few decades. The low-lying Yampah Marsh, the reference site, is likely to be inundated due to future sea level rise when highest tides arrive; while a higher percentage of Hester Marsh, the restored site, would retain marsh vegetation in coming decades, regardless of tidal conditions. Our study provides important information for examining the outcome of restoration practices that include surface elevation in tidal wetlands under climate changes.Several files can be found from this data package.1. README.md: This file describes the title, journal, co-authors, abstract, repository structure and model version.2. Simulation_Setups.zip: The file contains the model configuration files (XML format) for ATS. 3. Notebooks.zip: The file contains the Jupyter notebooks for generating the pre- and post-restoration meshes and the meshes of future scenarios. 4. Figures.zip: The file contains the figures used in the manuscript.5. Data.zip: The file contains the data used to drive the model simulations, including watershed and wetlands boundaries, mesh files and references to additional datasets (e.g., meteorological forcing, tidal dataset, DEMs, land cover, soil properties). Also, it contains water level observations at the restored wetland.

54 ENVIRONMENTAL SCIENCES

Direct Air Capture Case Studies: Sorbent System (Rev. 1)

In 2022, the National Energy Technology Laboratory published a techno-economic assessment (TEA) examining the performance and cost of a generic solid sorbent-based direct air capture (DAC) system, “Direct Air Capture Case Studies: Sorbent System”. Revision 1 of this report builds on the previous effort by updating assumptions to reflect the evolving industry and recent developments in the DAC research and development (R&D) portfolio. Revision 1 of the report also expands the case list to examine a variety of sorbent DAC system configurations. The objective of this series is to present transparent and independent TEAs that can serve as a guideline for sorbent DAC TEA development and highlight potential avenues for cost reductions that can inform R&D. The sorbent considered is not reflective of any one material type; rather, it represents an approximate average of reported material performance in the literature. The base cases presented in this series do not represent optimized systems due to the nascence of the technology and lack of publicly available information. The base cases serve as a reference for informative sensitivity analyses.

54 ENVIRONMENTAL SCIENCES

Arctic shipping under global change: A case study of offshore oil exports

We explore impacts of sea ice thinning and evolutions in the energy sector on future use of the Northern Sea Route (NSR) versus the Suez Canal Route (SCR), using a case study of shipping oil extracted from the offshore Russian Arctic to China. We combine an integrated human-Earth system model with a shipping cost model to incorporate impacts on both oil production and shipping costs under internally consistent scenarios. We find that the NSR could become cost-competitive with the SCR as sea ice thickness declines, especially in an RCP8.5 scenario, due to decreasing fuel and icebreaker escort costs. In a global energy evolution scenario consistent with RCP2.6, high emissions costs on the longer SCR may outweigh the costs associated with thicker sea ice on the NSR. Our novel framework provides integrated projections of NSR shipping traffic driven by a specific commodity likely to be shipped through the Arctic.

Arctic