Search NASA⌕ Search

SEARCH · Search NASA

Results for “ccn”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Final Report, The Influence of Organic-Aerosol Emissions and Aging on Regional and Global Aerosol Size Distributions and the CCN Number Budget

We conducted laboratory experiments and analyzed data on aging of organic aerosol and analysis of field data on volatility and CCN activity. With supplemental ASR funding we participated in the FLAME-IV campaign in Missoula MT in the Fall of 2012, deploying a two-chamber photochemical aging system to enable experimental exploration of photochemical aging of biomass burning emissions. Results from that campaign will lead to numerous publications, including demonstration of photochemical production of Brown Carbon (BrC) from secondary organic aerosol associated with biomass burning emissions as well as extensive characterization of the effect of photochemical aging on the overall concentrations of biomass burning organic aerosol. Excluding publications arising from the FLAME-IV campaign, project research resulted in 8 papers: [11, 5, 3, 10, 12, 4, 8, 7], including on in Nature Geoscience addressing the role of organic compounds in nanoparticle growth [11]

54 ENVIRONMENTAL SCIENCES↗

Tropospheric and stratospheric wildfire smoke profiling with lidar: mass, surface area, CCN, and INP retrieval

We present retrievals of tropospheric and stratospheric height profiles of particle mass, volume, surface area, and number concentrations in the case of wildfire smoke layers as well as estimates of smoke-related cloud condensation nuclei (CCN) and ice-nucleating particle (INP) concentrations from backscatter lidar measurements on the ground and in space. Conversion factors used to convert the optical measurements into microphysical properties play a central role in the data analysis, in addition to estimates of the smoke extinction-to-backscatter ratios required to obtain smoke extinction coefficients. The set of needed conversion parameters for wildfire smoke is derived from AERONET observations of major smoke events, e.g., in western Canada in August 2017, California in September 2020, and southeastern Australia in January–February 2020 as well as from AERONET long-term observations of smoke in the Amazon region, southern Africa, and Southeast Asia. The new smoke analysis scheme is applied to CALIPSO observations of tropospheric smoke plumes over the United States in September 2020 and to ground-based lidar observation in Punta Arenas, in southern Chile, in aged Australian smoke layers in the stratosphere in January 2020. These case studies show the potential of spaceborne and ground-based lidars to document large-scale and long-lasting wildfire smoke events in detail and thus to provide valuable information for climate, cloud, and air chemistry modeling efforts performed to investigate the role of wildfire smoke in the atmospheric system.

54 ENVIRONMENTAL SCIENCES↗

The CCN counter of the IOPG of Puy de Dome: Main characterisics and results of measurements

In performing the data analysis of the measurements achieved during the Workshop with the device, a global approach was preferred rather than an individual analysis, in order to illustrate some main characteristics in the behavior of the device with respect to a mean behavior resulting from a general survey of all the equipments involved in each experiment. The device tends generally to overestimate the CCN concentrations measured near the high supersaturations and sometimes underestimates the concentrations close to 0.1% or 0.2% of supersaturation. Despite the fact that it belongs to a type of static diffusion chamber, it shows, however, similar spectra to those obtained with other types of chambers (continuous flow diffusion chamber and haze chamber).

Serpolay, R.↗

A description of the UK Meteorological Office CCN counter

The chamber is a thermal gradient diffusion type with the upper plate at room temperature and the lower plate thermoelectrically cooled. The light from a 25W projector bulb is focused in a beam of approximations 1x3 mm in the central part of the chamber. The light scattered by drops is viewed in the forward direction (40 deg) by a microscope and a sensitive photodetector. Experiments were performed to relate the peak output from the photocell with the maximum number of drops in the beam recorded photographically. The microscope is used to check the calibration at low concentrations of CCN. The results of the experiments and the performance of the counter are reported.

Kitchen, M.↗

CCN comparisons of static diffusion chambers

Nine CCN counters of the static diffusion (SDC) type were compared with one another and with continuous flow diffusion (CFD) chambers. The nine SDCs showed a considerable amount of variation, largely attributable to newness and/or lack of prior calibration of some units. The five more consistent instruments agreed quite well, to within at least 20 percent of the NRL mobility analyzer and to within 10 percent at 1 percent supersaturation. There was satisfactory agreement between the more reliable SDC and CFD chambers.

Jiusto, J. E.↗

Project Final Report: Linking Plant Stress, Biogenic SOA, and CCN Production - A New Feedback in the Climate System?

This project worked toward understanding the role of variable biogenic emissions in the formation of secondary organic aerosol (SOA), and in turn the potential for this aerosol to affect cloud droplet formation. It was premised on the idea that a changing climate could impose biogenic and abiogenic stresses on plants that would affect the emissions of volatile organic compounds (VOCs). The transformation of these VOCs to SOA and cloud condensation nuclei (CCN) implied the possibility of a feedback mechanism within the biosphere/atmosphere/climate system. The project’s activities centered on laboratory experiments to study the effects of stresses on plants and plant-derived material under controlled conditions, observing both the VOC emissions and the aerosol that formed from the oxidation of those VOCs. The results highlighted the potentially important contributions of stress and decomposition mechanisms to biogenic SOA formation. Related field measurements elucidated the conditions when these factors could be important in the ambient environment. The project also revealed repeated the complexity of the stress/VOC emission relationship, and the difficulty in expressing these relationships in a comprehensive manner.

54 ENVIRONMENTAL SCIENCES↗

Improving BC Mixing State and CCN Activity Representation With Machine Learning in the Community Atmosphere Model Version 6 (CAM6)

Abstract Representing mixing state of black carbon (BC) is challenging for global climate models (GCMs). The Community Atmosphere Model version 6 (CAM6) with the four‐mode version of the Modal Aerosol Module (MAM4) represents aerosols as fully internal mixtures with uniform composition within each aerosol mode, resulting in high degree of internal mixing of BC with non‐BC species and large mass ratio of coating to BC ( R BC , the mass ratio of non‐BC species to BC in BC‐containing particles). To improve BC mixing state representation, we coupled a machine learning (ML) model of BC mixing state index trained on particle‐resolved simulations to the CAM6 with MAM4 (MAM4‐ML). In MAM4‐ML, we use R BC to partition accumulation mode particles into two new modes, BC‐free particles and BC‐containing particles. We adjust R BC to make the modeled BC mixing state index ( χ mode ) match the one predicted by the ML model ( χ ML ). On a global average, the mass fraction of BC‐containing particles in accumulation mode decreases from 100% (MAM4‐default) to 48% (MAM4‐ML). The globally averaged χ mode decreases from 78% (MAM4‐default) to 63% (MAM4‐ML, 19% reduction) and agrees well with χ ML (66%). The R BC decreases by 52% for accumulation mode and better agrees with observations. The hygroscopicity drops by 9% for BC‐containing particles in accumulation mode, leading to a 20% reduction in the BC activation fraction. The surface BC concentration increases most (6.9%) in the Arctic, and the BC burden increases by 4%, globally. Our study highlights the application of the ML model for improving key aerosol processes in GCMs.

Meteorology & Atmospheric Sciences↗

Memo, "Incorporation of HLW Glass Shell V2.0 into the Flowsheets," to ED Lee, CCN: 184905, October 20, 2009

Efforts are being made to increase the efficiency and decrease the cost of vitrifying radioactive waste stored in tanks at the U.S. Department of Energy Hanford Site. The compositions of acceptable and processable high-level waste (HL W) glasses need to be optimized to minimize the waste-form volume and, hence, to reduce cost. A database of glass properties of waste glass and associated simulated waste glasses was collected and documented in PNNL 18501, Glass Property Data and Models for Estimating High-Level Waste Glass Volume and glass property models were curve-fitted to the glass compositions. A routine was developed that estimates HL W glass volumes using the following glass property models: II Nepheline, II One-Percent Crystal Temperature (T1%), II Viscosity (11) II Product Consistency Tests (PCT) for boron, sodium, and lithium, and II Liquidus Temperature (TL). The routine, commonly called the HL W Glass Shell, is presented in this document. In addition to the use of the glass property models, glass composition constraints and rules, as recommend in PNNL 18501 and in other documents (as referenced in this report) were incorporated. This new version of the HL W Glass Shell should generally estimate higher waste loading in the HL W glass than previous versions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TRACER-CAT-LANL Aerosol Optics and Chemical Speciation - CCN

Aerosol size distribution, optical properties, and speciation data collected in La Port TX, during TRACER-CAT-LANL, July 2022, with basic trace gas measurements. All sampling was conducted with an identical aerosol inlet as the standard ARM-AOS systems. The TRacking Aerosol Convection interactions ExpeRiment Carbonaceous Aerosols Thrust by Los Alamos National Laboratory (TRACER-CAT-LANL, July 2022) was designed to complement the larger ARM TRACER science goals to understand convective cloud lifecycles and aerosol-convection interactions. TRACER-CAT-LANL is focused on understanding the relationship between particle composition and light absorption and the influence of water uptake on this relationship. This aerosol and trace gas data can be used to understand the relationship between particle composition and light absorption and the influence of water uptake on this relationship. Instruments Include: Picarro GHG Photoacoustic Soot Spectrometer (PASS-3) Humidified-cavity attenuated phase shift-single scattering albedo particulate matter monitor (H-CAPS-PMSSA) Soot Particle Aerosol Mass Spectrometer (SPAMS) Single-Particle Soot Photometer (SP2) Cloud Condensation Nuclei Counter (CCNc) Aerodynamic Particle Sizer (APS) Scanning Mobility Particle Sizer (SMPS)

54 ENVIRONMENTAL SCIENCES↗

UMR dual mode CCN counter (modes: CFD plus haze)

The chamber consists of two vertical plates 100 cm long in the vertical direction and 13 cm wide, with a 0.8 cm spacing between the plates. The haze mode is used for the nuclei active at supersaturations (S) from 0.0133 to 0.173%. In this mode the two plates are kept at the same temperature (25 C). In the CFD mode the supersaturation is determined by the temperature difference between the two plates. About 40 minutes is required to obtain a spectrum (5 values of S in the CFD mode, plus 7 values of S in the haze mode). About half of this time is used to adjust the temperatures and flows; the rest is used in actual counting of the nuclei. Comparisons of the counter to other types of counters are reported.

Alofs, D. J.↗

An automatic light scattering CCN counter

The counter is a static thermal diffusion chamber which has been modified to include an optical system for the determination of droplet concentration by the measurement of scattered light. The determination of concentration is made by measurement of the peak scattered light signal from the cloud of growing droplets which is a function of both the droplet concentration and chamber supersaturation. Because the formation of the peak is related to the rate of growth of the droplets and sedimentation, both of which are determined by supersaturation, the system calibration can be uniquely determined by comparison with an absolute counter such as a static diffusion chamber with a photographic recording system.

Lala, G. G.↗