Search NASA⌕ Search

SEARCH · Search NASA

Results for “cell measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Collection efficiency measurements for solar cell research

A system was established for measuring absolute, spectral collection efficiency that is well suited to solar cell research and development. Determination of spectral collection efficiency involves measurements of the incident photon intensity, the device reflection coefficient, and the cell short circuit current. A monochromatic photon flux is obtained with a high intensity Bausch and Lomb monochromator, and an Epply thermopile detector is used to measure incident intensity. Normal incidence reflectivity measurements are achieved with a prism type beam splitter. The experimental approach is discussed, measurements of the reflectivity of evaporated silver films are considered. Collection efficiency measurements of silicon solar cells are presented, and collection efficiency studies of Cu20 solar cells are discussed.

Hampton, H. L.↗

Building Better Biosensors for Exploration into Deep-Space, Using Humanized Yeast

1.BioSentinel is 1 of 13 secondary payloads hitching a ride beyond Low Earth Orbit on Exploration Mission 1 (EM-1), set to launch from NASAs Space Launch System in 2019. EM-1 is our first opportunity to investigate the effects of the deep space environment on a eukaryotic biological system, the budding yeast S. cerevisiae. Though separated by a billion years of evolution we share hundreds of genes important for basic cell function, including responses to DNA damage. Thus, yeast is an ideal biosensor for detecting typesextent of damage induced by deep-space radiation.We will fly desiccated cells, then rehydrate to wake them up when the automated payload is ready to initiate the experiment. Rehydration solution contains SC (Synthetic Complete) media and alamarBlue, an indicator for changes in growth and metabolism. Telemetry of LED readings will then allow us to detect how cells respond throughout the mission. The desiccation-rehydration process can be extremely damaging to cells, and can severely diminish our ability to accurately measure and model cellular responses to deep-space radiation. The aim of this study is to develop a better biosensor: yeast strains that are more resistant to desiccation stress. We will over-express known cellular protectants, including hydrophilin Sip18, the protein disaggregase Hsp104, and thioredoxin Trx2, a responder to oxidative stress, then measure cell viability after desiccation to determine which factors improve stress tolerance. Over-expression of SIP18 in wine yeast starter cultures was previously reported to increase viability following desiccation stress by up to 70. Thus, we expect similar improvements in our space-yeast strains. By designing better yeast biosensors we can better prepare for and mitigate the potential dangers of deep-space radiation for future missions.This work is funded by NASAs AES program.

biosensor↗

GaAs shallow-homojunction solar cells

With the objective of demonstrating the feasibility of fabricating 2 x 2 cm efficient, shallow homojunction GaAs solar cells for space applications, this program addresses the basic problems of material preparation and device fabrication. Significant progress was made and conversion efficiencies close to 16 percent at AM0 were obtained on 2 x 2 cm cells. Measurements and computer analyses on the n(+)/p/p(+) shallow homojunction cells indicate that such cell configuration should be very resistant to 1 MeV electron irradiation.

Fan, J. C.↗

Susceptibility Measurements Near the He-3 Liquid-Gas Critical Point

An experiment is now being developed to measure both the linear susceptibility and specific heat at constant volume near the liquid-gas critical point of He-3 in a microgravity environment. An electrostriction technique for measuring susceptibility will be described. Initial electrostriction measurements were performed on the ground along the critical isochore in a 0.5 mm high measurement cell filled to within 0.1 % of the critical density. These measurements agreed with the susceptibility determined from pressure-density measurements along isotherms. The critical temperature, T(sub c), determined separately from specific heat and susceptibility measurements was self-consistent. Susceptibility measurements in the range t = T/T(sub c) - 1 > 10(exp -4)were fit to Chi(sup *)(sub T) = Gamma(sup +)t(exp -lambda)(1 + Gamma(sup +)(sub 1)t(sup delta). Best fit parameters for the asymptotic amplitude Gamma(sup +) and the first Wegner amplitude Gamma(sup +)(sub 1) will be presented and compared to previous measurements.

Barmatz, Martin↗

Some failure modes and analysis techniques for terrestrial solar cell modules

Analysis data are presented on failed/defective silicon solar cell modules of various types and produced by different manufacturers. The failure mode (e.g., internal short and open circuits, output power degradation, isolation resistance degradation, etc.) are discussed in detail and in many cases related to the type of technology used in the manufacture of the modules; wherever applicable, appropriate corrective actions are recommended. Consideration is also given to some failure analysis techniques that are applicable to such modules, including X-ray radiography, capacitance measurement, cell shunt resistance measurement by the shadowing technique, steady-state illumination test station for module performance illumination, laser scanning techniques, and the SEM.

Shumka, A.↗

Instrumentation and Methods to Measure Dynamic Forces During Exercise Using the Horizontal Exercise Machine

It is hypothesized that bone loss experienced by astronauts in zero gravity conditions may be curtailed by appropriate exercise. According to Wolf's law, bone regenerates when muscles produce stresses by pulling on the bone during daily activity and/or exercise on Earth. To use this theory to prevent or decrease bone loss, one needs to quantify musculoskeletal loads and relate them to bone density changes. In the context of the space program, it is desirable to determine musculoskeletal loads during exercise so that one may make similar measurements on Earth and in space. In this manner, load measurements on Earth may be used as reference to generate similar loads during exercise in space. A research project to investigate the effects of high-resistive exercise to decrease bone density loss underzero-gravity conditions is being carried out in Life Sciences Research Laboratories at NASA JSC. The project consists of a bed-rest study whereby subjects remain in horizontal position for seventeen weeks. During the study, a subset of those subjects executes a regime of resistive exercises in the horizontal exercise machine (HEM). The HEM was designed so that subjects remain horizontal while exercising to minimize gravity loading even during exercise. Bone density of each subject is measured throughout the duration of their participation. The objective of the study is to determine if the resistive exercises are effective in diminishing or eliminating bone loss. My participation in this project relates to instrumentation, measurement, and processing of signals from displacement sensors (optical encoders) and load-cells. Measurement of displacements will be used to determine the motion of the body during exercise, and load measurements will be used (along with displacement data) to determine forces and torques exerted on each section of the body during exercise. Further, I have assisted in specifying new sensors to be added to the HEM and to a new prototype resistive exercise machine called the Interim Resistive Exercise Device (IRED). New load cells and encoders should be mounted in these devices to obtain more complete kineto-dynamic information. This report includes a description of the instrumentation that was built to perform measurements in the HEM and the IRED, along with the software that was developed to collect the measurements. It also includes examples of measurements taken in the HEM. Finally, a plan is laid out that describes how these measurements may be used to determine forces exerted by muscles for each exercise.

Figueroa, Fernando↗

Temperature variable long path cell for absorption measurements

The design and construction of a long path cell for absorption measurements at temperatures ranging from 215-470 K and at pressures from vacuum to 10 atm are described. The cell consists of three concentric stainless-steel tubes; the innermost tube is 6.5-in. in internal diameter, has a volume of about 47 l, and contains White-type optics, six thermocouples, and a gas input tube; and the outermost tube provides a vacuum Dewar around the inner assembly. The optical design and temperature control system for the long path temperature variable cell are examined. The long path cell is applicable for analyzing temperature and pressure dependence of spectra and reaction rates of gases, and the cell has flow and photolysis capabilities for studying transient species and photochemically initiated reactions. A diagram of the cell is provided.

Shetter, R. E.↗

Status Update on the Seal/bearing Rotordynamics Test Facility at Case Western Reserve University

The CWRU Seal/Bearing test facility is shown along with the revised force measuring system. This facility has recently been retrofitted with a high pressure, high flow oil system. The high pressure high flow water system remains in place to test seals. Also, a new high flow air system is now installed. Thus, testing to determine static and dynamic properties can now be performed using oil, water, or air on this single facility. The oil system is currently being used to determine rotordynamic properties of a NASA four pocket hydrostatic journal bearing. The revised dual system force measuring configuration is performing with excellent accuracy. That is, the dynamic force measurements are made simultaneously with two independent systems, one with piezoelectric load cells and the other with strain gage load cells. The difference is less than 2 pct. between these two sets of load cell measurements on recent tests with a static eccentricity set close to zero and an orbit radius of 0.0004 inch. The extracted stiffness, damping and inertia coefficients is given for the test conditions shown, as extracted from the two independent dynamic force measurements.

Adams, Michael L.↗

Ice Growth Model for Polar Water Capture Systems

In-situ resource utilization (ISRU) is essential to NASA’s goal of sustainable and cost-effective missions to the Moon and beyond. Water has become a particular source of interest since its discovery in the permanently shadowed regions (PSRs) of the Moon. This water exists as ice bound within the regolith, so one mode of capture is heating to sublimation temperatures and capturing at very low pressure. It then can be stored in ice form and transported out of the PSR and to a sunlit ridge, where processes such as electrolysis can be performed[2]. An understanding of frost growth dynamics under rarefied conditions is necessary for successful water capture and storage due to transient thermal properties of frost. A Diffusion-Limited Aggregation (DLA) approach was taken to analytically model bulk thermal conductivity changes of the growing frost layer under varying wall temperatures and frost layer porosities. The model utilizes well-known correlations for effective thermal conductivity and records the values as the frost layer thickness increases. This thermal conductivity can be applied to a known temperature change and be used to evaluate heat flux through the combined frost layer and tank wall for either a flat plate or cylindrical geometry. An experiment is described that will evaluate this model using one-dimensional frost growth on a horizontal, flat plate under low-pressure. The ice growth will be measured using a millimeter-scale photogrammetry camera system and a load cell measured transient mass growth.

In situ Resource Utilization↗

Ice Growth Model for Polar Water Capture Systems

In-situ resource utilization (ISRU) is essential to NASA’s goal of sustainable and cost-effective missions to the Moon and beyond. Water has become a particular source of interest since its discovery in the permanently shadowed regions (PSRs) of the Moon. This water exists as ice bound within the regolith, so one mode of capture is heating to sublimation temperatures and capturing at very low pressure. It then can be stored in ice form and transported out of the PSR and to a sunlit ridge, where processes such as electrolysis can be performed[2]. An understanding of frost growth dynamics under rarefied conditions is necessary for successful water capture and storage due to transient thermal properties of frost. A Diffusion-Limited Aggregation (DLA) approach was taken to analytically model bulk thermal conductivity changes of the growing frost layer under varying wall temperatures and frost layer porosities. The model utilizes well-known correlations for effective thermal conductivity and records the values as the frost layer thickness increases. This thermal conductivity can be applied to a known temperature change and be used to evaluate heat flux through the combined frost layer and tank wall for either a flat plate or cylindrical geometry. An experiment is described that will evaluate this model using one-dimensional frost growth on a horizontal, flat plate under low-pressure. The ice growth will be measured using a millimeter-scale photogrammetry camera system and a load cell measured transient mass growth.

ice growth↗

Langmuir Probe Measurements in an Inductively Coupled GEC Reference Cell Plasma

Measurements of electron number density, electron temperature, and electron energy distribution function (EEDF) using a compensated Langmuir probe have been performed on an inductively (transformer ) coupled Gaseous Electronics Conference (GEC) reference cell plasma. The plasma source is operated with CH4, CF4, or their mixtures with argon. The effect of independently driving the electrode supporting the wafer on the probe data is studied. In particular, we find that the plasma structure depends on the phase in addition to the magnitude of the power coupled to the electrode relative to that of the transformer coil. The Langmuir probe is translated in a plane parallel to the electrode to investigate the spatial structure of the plasma. The probe data is also compared with fluid model predictions.

Ji, J. S.↗

Impedances of electrochemically impregnated nickel electrodes as functions of potential, KOH concentration, and impregnation method

Impedances of fifteen electrodes form each of the four U.S. manufactures were measured at 0.200 V vs. the Hg/HgO reference electrode. This corresponds to a voltage of 1.145 for a Ni/H2 cell. Measurements were also made of a representative sample of these at 0.44 V. At the higher voltage, the impedances were small and very similar, but at the lower voltage there were major differences between manufacturers. Electrodes from the same manufacturers showed only small differences. The impedances of electrodes from two manufacturers were considerably different in 26 percent KOH from those in 31 percent KOH. These preliminary results seen to correlate with the limited data from earlier life testing of cells from these manufacturers. The impedances of cells being tested for Space Station Freedom are being followed, and more impendance measurements of electrodes are being performed as functions of manufacturer, voltage, electrolyte concentration, and cycle history in hopes of finding better correlations of impedance with life.

Reid, Margaret A.↗

Absolute integrated intensity for the nu-1 sulfur dioxide band

The absolute integrated intensity of the IR vibration-rotation nu-1 SO2 band was measured using the linear portion of the curve of growth. Infrared spectroscopic-absorption cell measurements were performed on sulfur dioxide at partial pressures less than 0.15 torr with nitrogen added to give a total pressure of 705 torr, the path length being 4 mm. The absolute integrated intensity was determined to be 112.0 plus or minus 2.6/cm/sq (atm cm) at 296 K at the 95% confidence level.

Pilon, P. J.↗

Graphics modelling of non-contact thickness measuring robotics work cell

A system was developed for measuring, in real time, the thickness of a sprayable insulation during its application. The system was graphically modelled, off-line, using a state-of-the-art graphics workstation and associated software. This model was to contain a 3D color model of a workcell containing a robot and an air bearing turntable. A communication link was established between the graphics workstations and the robot's controller. Sequences of robot motion generated by the computer simulation are transmitted to the robot for execution.

Warren, Charles W.↗

Measuring Pressure Has a New Standard

The Force-Balanced Piston Gauge (FPG) tests and calibrates instrumentation operating in the low pressure range. The system provides a traceable, primary calibration standard for measuring pressures in the range of near 0 to 15 kPa (2.2 psi) in both gauge and absolute measurement modes. The hardware combines a large area piston-cylinder with a load cell measuring the force resulting from pressures across the piston. The mass of the piston can be tared out, allowing measurement to start from zero. A pressure higher than the measured pressure, which keeps the piston centered, lubricates an innovative conical gap located between the piston and the cylinder, eliminating the need for piston rotation. A pressure controller based on the control of low gas flow automates the pressure control. DHI markets the FPG as an automated primary standard for very low-gauge and absolute pressures. DHI is selling the FPG to high-end metrology laboratories on a case by case basis, with a full commercial release to follow.

Source record↗

Partial Pressures for Several In-Se Compositions from Optical Absorbance of the Vapor

The optical absorbance of the vapor phase over various In-Se compositions between 33.3-60.99 at.% Se and 673-1418 K was measured and used to obtain the partial pressures of Se2(g) and In2Se(g). The results are in agreement with silica Bourdon gauge measurements for compositions between 50-61 at.%, but significantly higher than those from Knudsen cell and simultaneous Knudsen-torsion cell measurements. It is found that 60.99 at.% Se lies outside the sesquiselenide homogeneity range and 59.98 at.% Se lies inside and is the congruently melting composition. The Gibbs energy of formation of the liquid from its pure liquid elements between 1000-1300 K is essentially independent of temperature and falls between -36 to -38 kJ per g atomic weight for 50 and 56% Se at 1200 and 1300 K.

Brebrick, R. F.↗

Solar Cell Calibration and Measurement Techniques

The increasing complexity of space solar cells and the increasing international markets for both cells and arrays has resulted in workshops jointly sponsored by NASDA, ESA and NASA. These workshops are designed to obtain international agreement on standardized values for the AMO spectrum and constant, recommend laboratory measurement practices and establish a set of protocols for international comparison of laboratory measurements. A working draft of an ISO standard, WDI 5387, 'Requirements for Measurement and Calibration Procedures for Space Solar Cells' was discussed with a focus on the scope of the document, a definition of primary standard cell, and required error analysis for all measurement techniques. Working groups addressed the issues of Air Mass Zero (AMO) solar constant and spectrum, laboratory measurement techniques, and the international round robin methodology. A summary is presented of the current state of each area and the formulation of the ISO document.

Bailey, Sheila↗