Search NASA⌕ Search

SEARCH · Search NASA

Results for “centrifugal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Materials processing in a centrifuge - Numerical modeling of macrogravity effects

The fluid mechanics associated with crystal growth processes on a centrifuge is investigated. A simple scaling analysis is used to examine the relative magnitudes of the forces acting on the system and good agreement is obtained with previous studies. A two-dimensional model of crystal growth on a centrifuge is proposed and calculations are undertaken to help in understanding the fundamental transport processes within the crystal growth cell. Results from three-dimensional calculations of actual centrifuge-based crystal growth systems are presented both for the thermodynamically stable and unstable configurations. The calculations show the existence of flow bifurcations in certain configurations but not in all instances. The numerical simulations also show that the centrifugal force is the dominant stabilizing force on fluid convection in the stable configuration. The stabilizing influence of the Coriolis force is found to be only secondary in nature. No significant impact of gravity gradient is found in the calculations. Simulations of unstable configurations show that the Coriolis force has a stabilizing influence on fluid motion by delaying the onset of unsteady convection. Detailed flow and thermal field characteristics are presented for all the different cases that are simulated.

Ramachandran, N.↗

Possible biomedical applications and limitations of a variable-force centrifuge on the lunar surface: A research tool and an enabling resource

Centrifuges will continue to serve as a valuable research tool in gaining an understanding of the biological significance of the inertial acceleration due to gravity. Space- and possibly lunar-based centrifuges will play a significant and enabling role with regard to the human component of future lunar and martian exploration, both as a means of accessing potential health and performance risks and as a means of alleviating these risks. Lunar-based centrifuges could be particularly useful as part of a program of physiologic countermeasures designed to alleviate the physical deconditioning that may result from prolonged exposure to a 1/6-g environment. Centrifuges on the lunar surface could also be used as part of a high-fidelity simulation of a trip to Mars. Other uses could include crew readaptation to 1 g, waste separation, materials processing, optical mirror production in situ on the Moon, and laboratory specimen separation.

Cowing, Keith L.↗

Simulation of Shuttle launch G forces and acoustic loads using the NASA Ames Research Center 20G centrifuge

The high cost and long times required to develop research packages for space flight can often be offset by using ground test techniques. This paper describes a space shuttle launch and reentry simulating using the NASA Ames Research Center's 20G centrifuge facility. The combined G-forces and acoustic environment during shuttle launch and landing were simulated to evaluate the effect on a payload of laboratory rates. The launch G force and acoustic profiles are matched to actual shuttle launch data to produce the required G-forces and acoustic spectrum in the centrifuge test cab where the rats were caged on a free-swinging platform. For reentry, only G force is simulated as the aero-acoustic noise is insignificant compared to that during launch. The shuttle G-force profiles of launch and landing are achieved by programming the centrifuge drive computer to continuously adjust centrifuge rotational speed to obtain the correct launch and landing G forces. The shuttle launch acoustic environment is simulated using a high-power, low-frequency audio system. Accelerometer data from STS-56 and microphone data from STS-1 through STS-5 are used as baselines for the simulations. This paper provides a description of the test setup and the results of the simulation with recommendations for follow-on simulations.

Shaw, T. L.↗

Maximum Likelihood Factor Analysis of the Effects of Chronic Centrifugation on the Structural Development of the Musculoskeletal System of the Rat

At the age of 30 days female Sprague-Dawley rats were placed on a 3.66 m radius centrifuge and subsequently exposed almost continuously for 810 days to either 2.76 or 4.15 G. An age-matched control group of rats was raised near the centrifuge facility at earth gravity. Three further control groups of rats were obtained from the animal colony and sacrificed at the age of 34, 72 and 102 days. A total of 16 variables were simultaneously factor analyzed by maximum-likelihood extraction routine and the factor loadings presented after-rotation to simple structure by a varimax rotation routine. The variables include the G-load, age, body mass, femoral length and cross-sectional area, inner and outer radii, density and strength at the mid-length of the femur, dry weight of gluteus medius, semimenbranosus and triceps surae muscles. Factor analyses on A) all controls, B) all controls and the 2.76 G group, and C) all controls and centrifuged animals, produced highly similar loading structures of three common factors which accounted for 74%, 68% and 68%. respectively, of the total variance. The 3 factors were interpreted as: 1. An age and size factor which stimulates the growth in length and diameter and increases the density and strength of the femur. This factor is positively correlated with G-load but is also active in the control animals living at earth gravity. 2. A growth inhibition factor which acts on body size, femoral length and on both the outer and inner radius at mid-length of the femur. This factor is intensified by centrifugation.

Amtmann, E.↗

Fluid Redistribution and Heart Rate in Humans During Whole-Body Tilting, G(z) Centrifugation, and Lower Body Negative Pressure

Gravity creates blood pressure gradients which redistribute body fluids towards the feet. Positive G(z) centrifugation and lower body negative pressure (LBNP) have been proposed to simulate these and other effects of gravity during long-term existence in microgravity. We hypothesized that the magnitude of upper-to-lower body fluid redistribution would increase according to the following order: short-arm centrifugation (SAC), long-arm centrifugation (LAC), head-up tilt (HUT), and LBNP. To test this hypothesis, we employed strain gauge plethysmography of the neck, thigh and calf during HUT and supine SAC and LAC up to lG(z) at the feet, and during supine LBNP to 100 mm Hg. Supine 100 mm Hg LBNP generates footward force and produces transmural blood pressures in the foot approximately equal to 1 G(z) (90 deg) HUT. Heart rate was measured via cardiotachometry. Control measurements were made while supine. SAC and LAC elicited similar increases in thigh volume at 1 G(z) (2.3 +/- 0.4 and 2.1 +/- 0.1%, respectively; mean +/- se, n greater than or equal to 7). At 100 mm Hg LBNP, thigh volume increased (3.4 +/- 0.3%) significantly more than during l G(z) centrifugation (p less than 0.05). Surprisingly, due to a paradoxical 0.6% reduction of thigh volume between 0.8 and 1.0 G(z) HUT, thigh volume was increased only 0.6 +/- 0.3% at 1 G(z) HUT. The calf demonstrated similar, although less definitive, responses to the various gravitational stimuli. Neck volume tended to decrease less during HUT than during the other stimuli. Heart rate increased similarly during HUT (18 +/- 2 beats/min) and LAC (12 +/- 2 beats/min), and exhibited still greater elevation during LBNP (29 +/- 4 beats/min), yet did not increase during SAC. These results suggest upright posture activates mechanisms that counteract footward fluid redistribution which are not activated during supine applications of simulated gravity. LAC more closely approximated effects of normal gravity (HUT) than LBNP. Therefore, when considering LBNP to simulate gravity, these findings support efforts to reduce the cardiovascular stress imposed by LBNP, while preserving the gravity-like force generated by LBNP.

Watenpaugh, D. E.↗

Body Weight Gain during Altered Gravity: Spaceflight, Centrifugation and Transitions

Gravity is a force that influences all living systems, and is often disregarded in the study of environment on growth and development. To assess the effect of gravity exposure on growth, immature rats (130-200 g) were evaluated during chronic altered gravity exposure and during transition between gravity fields. The effects of 14 days of spaceflight on body weight gain were evaluated (n=12) and compared to controls. Spaceflight did not affect weight gain. In 6 rats, the transition from spaceflight to 1 G showed a significant (p less than 0.05) post flight weight loss over 48 hr of 13 g compared to controls. Over subsequent days this loss was compensated for with no difference noted after 5 days. Exposure to hypergravity, 2 G for 16 days, was evaluated in groups of n=6 (Control; On Center Control (OCC); Centrifuged). With centrifugation or OCC there was a reduction in body weight within 24 hr. The OCC regained control weights within 13 days. The weight difference, 26 +/- 1 g, persisted with 2 G with no subsequent difference in weight gain over days 3-16 compared to controls; 3.7 +/- 0.1 versus 3.9 +/- 0.1 g/day respectively. Transition from centrifugation to 1 G resulted in a weight increase within 48 hours. Over 16 days the rate of gain was increased 3.1 +/- 0.1 g/day for centrifuge compared to 2.1 +/- 0.1 g/day for controls between Day 3 to 16. However, differences from control were still noted on Day 16. Transition from one gravity field to another causes acute changes in body weight. Transition to microgravity or 1 G, following the acute changes, results in adjustments to attain a normal weight. In hypergravity the acute reduction in body weight persist, but weight gain is normal. Transitioning from hypergravity to 1G results in an increased weight gain to compensate for the persistent reduction during exposure.

Wade, Charles E.↗

Re-Adaptation to 1-G of Pregnant Rats Following Exposure to Spaceflight or Centrifugation

Late-pregnant rat dams were flown on a 9-day Space Shuttle mission or exposed to 1.5, 1.75 or 2-g centrifugation and compared with 1 .O-g vivarium controls. Exposure to altered gravity began on the 11th day and recovery occurred on the 20th day of the dams' 22-day pregnancy. In the 1 st experiment, comparisons were made between Flight (FLT), Synchronous (SYN; identically-housed) and Vivarium (VIV) controls. In the 2nd experiment, comparisons were made between dams centrifuged at 2-G, 1.75-G, 1.5-G, Rotational controls (1.08-G) or Stationary controls (1 G). Within three hours of recovery from either spaceflight or centrifugation, the dams' locomotor behavior was videotaped for 2 min. FLT dams showed dramatically reduced movement relative to both SYN and VIV control conditions, with significantly greater amounts of locomotor activity observed in SYN as compared to VIV dams. Significantly greater locomotor activity was observed in SYN as compared to VIV controls. In the second experiment, no differences were observed between dams exposed either 1, 1.5, 1.75, or 2-G. In both studies, the dams showed similar patterns of hindlimb rearing. Together, these findings provide quantitative evidence for decreased locomotor activity during re-adaptation to 1-g following spaceflight, but not centrifugation.

Johnson, K. E.↗

Gender Differences in Cardiovascular Tolerance to Short Arm Centrifugation

In preparation for the NASA Artificial Gravity (AG) pilot study, the tolerability of the proposed AG parameters was tested in 11 ambulatory human subjects (6m, 5w) by exposing each to a short arm centrifuge trial. Subjects were oriented in the supine position (but inclined 6deg head down) on one arm of the centrifuge, and the rotation rate (30.6-33.4 rpm) and radial position of the feet were set to produce 2.5G of equivalent gravitational load at the force plate directly beneath the feet, 1G at the level of the mediastinum, and approximately 0.55G at the labyrinth. Amongst the 6 men participating in this preliminary study, 5 completed at least 60 minutes of the trial successfully with no adverse sequelae. However, amongst the female cohort the test was stopped by the medical monitor before 60 min in all but one case, with pre-syncope listed as the reason for termination in all cases. Mean time before abort of the centrifuge run amongst the women was 33.2 +/- 20.97 min. It is known that women have a greater predisposition to syncope during orthostatic stress, under normal tilt table conditions, during LBNP, and following space flight. The reasons for this difference are the subject of some debate, but anthropometric factors, the vasoactive effects of sex hormones, gender differences in susceptibility to motion sickness, catecholamine levels, ability to augment total peripheral resistance in response to orthostatic stress, and structural differences in cardiac anatomy and physiology have all been suggested. This finding led to the exclusion of women from the AG pilot study. Clearly if AG is to be employed as a multi-system countermeasure it must provide physiological protection at rotation rates within the tolerance limits of all potential astronauts. Further investigation of the responses of women to centrifugation will be necessary to determine how to adjust AG parameters for tolerance by female subjects before a more detailed investigation of the appropriate dose in terms of G load, rotation rate, exposure duration and frequency can be performed.

Fong, Kevin J.↗

Centrifugal Adsorption Cartridge System

The centrifugal adsorption cartridge system (CACS) is an apparatus that recovers one or more bioproduct(s) from a dilute aqueous solution or suspension flowing from a bioreactor. The CACS can be used both on Earth in unit gravity and in space in low gravity. The CACS can be connected downstream from the bioreactor; alternatively, it can be connected into a flow loop that includes the bioreactor so that the liquid can be recycled. A centrifugal adsorption cartridge in the CACS (see figure) includes two concentric cylinders with a spiral ramp between them. The volume between the inner and outer cylinders, and between the turns of the spiral ramp is packed with an adsorbent material. The inner cylinder is a sieve tube covered with a gas-permeable, hydrophobic membrane. During operation, the liquid effluent from the bioreactor is introduced at one end of the spiral ramp, which then constrains the liquid to flow along the spiral path through the adsorbent material. The spiral ramp also makes the flow more nearly uniform than it would otherwise be, and it minimizes any channeling other than that of the spiral flow itself. The adsorbent material is formulated to selectively capture the bioproduct(s) of interest. The bioproduct(s) can then be stored in bound form in the cartridge or else eluted from the cartridge. The centrifugal effect of the spiral flow is utilized to remove gas bubbles from the liquid. The centrifugal effect forces the bubbles radially inward, toward and through the membrane of the inner cylinder. The gas-permeable, hydrophobic membrane allows the bubbles to enter the inner cylinder while keeping the liquid out. The bubbles that thus enter the cylinder are vented to the atmosphere. The spacing between the ramps determines rate of flow along the spiral, and thereby affects the air-bubble-removal efficiency. The spacing between the ramps also determines the length of the fluid path through the cartridge adsorbent, and thus affects the bioproduct-capture efficiency of the cartridge. Depending on the application, several cartridges could be connected in a serial or parallel flow arrangement. A parallel arrangement can be used to increase product-capturing and flow capacities while maintaining a low pressure drop. A serial arrangement can be used to obtain high product-capturing capacity; alternatively, series-connected cartridges can be packed with different adsorbents to capture different bioproducts simultaneously.

Gonda, Steve R.↗

Space-Cent: Studying the Physiological and Anatomical Effects of Centrifugation and Head Down Tilt: 2021 Update

BACKGROUND The objective of this study was to evaluate the cerebral and ocular physiological and anatomical effects of head-down tilt bedrest (HDBR) with and without daily artificial gravity (AG) in healthy subjects to provide novel insights into possible countermeasures for the Spaceflight Associated Neuro-ocular Syndrome (SANS). Previous long-term studies using the spaceflight analog of strict 6° HDBR for 30 days revealed changes in ocular structure, including optic disc edema. The effects of an AG countermeasure using intermittent centrifugation to restore upright hydrostatic gradients and reduce the ocular and brain anatomical effects has not been explored. METHODS The effects of 60-day exposure to simulated microgravity (6° HDBR) on the cerebral, ocular and vestibular systems with and without the intervention of daily 30 minute exposure to AG (short-arm centrifugation) was evaluated in 24 healthy subjects. Non-invasive measurements of cerebral blood flow, intracranial blood volume (near infrared spectroscopy, NIRS), cerebral and ocular structure (MRI and optical coherence tomography), internal jugular vein area (ultrasound), lateral ventricular volumes (MRI), intraocular pressure, and sensorimotor/vestibular (i.e. balance and coordination) systems were made during various time-points during the bedrest study. Additional measures with ultrasound and NIRS were made during centrifugation. RESULTS The study began in Spring 2019 and all 24 subjects completed the testing by end of 2019. Data analysis continues. We report the following updated results for 2021. MRI showed significant decreases in carotid artery flow, increases in brain and CSF volumes, and aqueductal flow velocities in all subjects in HDT compared to baseline supine, but no effects of the short duration AG. All groups showed increased posterior globe flattening during bedrest compared to baseline, without protection from AG. As previously reported we observed chorioretinal folds for the first time in a bedrest analog, as well as optic disc edema, with no protection from the short-term AG. Data from the study is now being transmitted to the NASA LSDA which will allow for future research. CONCLUSIONS The 6 degree HDBR analog produced significant changes in the anatomical and physiological functions of the brain and eye in healthy subjects. Daily 30 minute exposure to AG with short-arm centrifugation had significant transient effects on physiology of the cerebrovascular system, but was not sufficient to prevent the anatomical effects of HDBR on the brain and eye.

E M Bershad↗

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 1 – Steady state modeling and speed ratio selection

Helium cryogenic systems which can provide cooling below the normal boiling point of helium (approximately 4.2 K) are often required by superconducting radio-frequency niobium resonators utilized in modern high-energy particle accelerators. Achieving temperatures below 4.2 K generally involves operating a cryogenic vessel with liquid helium under sub-atmospheric conditions, thereby lowering the saturation pressure and corresponding saturation temperature. Over the last several decades, multi-stage cryogenic centrifugal compressor trains (CC’s) have been operated efficiently and reliably within large-scale cryogenic systems to continuously evacuate helium vapor generated by a device within the vessel, maintaining sub-atmospheric conditions in the vessel while pressurizing the return vapor to above atmospheric conditions. Traditionally, these CC systems have been operated using empirically derived control philosophies and insight gathered from previous operational experience. Recent efforts at the Facility for Rare Isotope Beams (FRIB) have been aimed at the development of a theoretical basis to characterize the operation of multi-stage cryogenic centrifugal compressor train and utilizing predictive model results to generate control parameters. The objective of this research was identifying operational points which adequately balance cryogenic system efficiency, stability, and overall ease of operation. Furthermore, this manuscript provides an overview of the predictive model development, characterization of the FRIB cryogenic centrifugal compressors and implementation of the predicted performance results during steady-state system operation.

Compressor train control↗

Centrifuge modeling and numerical analysis on lateral performance of mono-bucket foundation for offshore wind turbines

The lateral loading performance of the mono-bucket foundation for offshore wind turbines is investigated in this study through a series of centrifuge tests and numerical analysis. Six mono-bucket models are considered to assess the influences of aspect ratio under the ultimate condition. The FE model is validated against the centrifuge test results, and the failure mechanism of the foundation is revealed. The parametric study and sensitivity analysis of the soil parameters are performed in the numerical simulations. A modified theoretical calculation method is proposed to estimate the ultimate lateral capacity of the suction bucket foundation by solving the limit equilibrium equations. A correction term is added in the calculation using the “m” method. The position of the rotation center is calculated, demonstrating a better accuracy compared to the previously reported geometric method. The modified calculation method is verified against the field test, the centrifuge test, and the laboratory test. The method is proved to be applicable in estimating the lateral performance of the mono-bucket foundation in a general form. Finally, this study aims to provide well-documented data and design references for practical engineers.

17 WIND ENERGY↗

Orientation illusions and heart-rate changes during short-radius centrifugation

Intermittent short-radius centrifugation is a promising countermeasure against the adverse effects of prolonged weightlessness. To assess the feasibility of this countermeasure, we need to understand the disturbing sensory effects that accompany some movements carried out during rotation. We tested 20 subjects who executed yaw and pitch head movements while rotating at constant angular velocity. They were supine with their main body axis perpendicular to earth gravity. The head was placed at the centrifuge's axis of rotation. Head movements produced a transient elevation of heart-rate. All observers reported head-contingent sensations of body tilt although their bodies remained supine. Mostly, the subjective sensations conform to a model based on semicircular canal responses to angular acceleration. However, some surprising deviations from the model were found. Also, large inter-individual differences in direction, magnitude, and quality of the illusory body tilt were observed. The results have implications for subject screening and prediction of subjective tolerance for centrifugation.

NASA Discipline Neuroscience↗

High Efficiency Centrifugal Compressor for Rotorcraft Applications

A centrifugal compressor research effort conducted by United Technologies Research Center under NASA Research Announcement NNC08CB03C is documented. The objectives were to identify key technical barriers to advancing the aerodynamic performance of high-efficiency, high work factor, compact centrifugal compressor aft-stages for turboshaft engines; to acquire measurements needed to overcome the technical barriers and inform future designs; to design, fabricate, and test a new research compressor in which to acquire the requisite flow field data. A new High-Efficiency Centrifugal Compressor stage -- splittered impeller, splittered diffuser, 90 degree bend, and exit guide vanes -- with aerodynamically aggressive performance and configuration (compactness) goals were designed, fabricated, and subquently tested at the NASA Glenn Research Center.

Centrifugal compressor↗

Development of a Computational Fluid Dynamics Model for a High-Speed Centrifugal Compressor

Computational fluid dynamics (CFD) has become widely used in the design and analysis of turbomachinery components such as centrifugal compressors. However, CFD is only a limited representation of experimental cases and struggles to model complex flows or can lack small model details to increase computation speed. To make advancements in compressor technology, designers need tools like CFD that can help them predict flow behavior in new designs. The High Efficiency Centrifugal Compressor (HECC) was designed by United Technologies Research Center (UTRC) for NASA to investigate the difficulties behind improving centrifugal compressor technology and to provide an open case to the turbomachinery research community. CFD analysis was completed by UTRC to aid in the design process. The pre-test study significantly overpredicted the compressor’s performance, and while post-test analysis was more representative, its results have yet to be publicly available. CFD technology has also since improved in recent years. In this study, a high-fidelity computational model for the vaneless configuration of HECC operating at its design point was developed and compared to an equivalent experimental case. This model incorporated GPU versions of mesh generation and solver codes from AeroDynamic Solutions, Inc. The development of such a model is significant since there has yet to be a published numerical simulation of HECC’s vaneless configuration. Additionally, the use of GPU codes decreases computation times for the model, which has allowed for the inclusion of impeller blade fillets. Initial results showed a general overprediction of compressor performance by the model. Predictions were more accurate for the impeller compared to predictions for the full compressor stage. Spanwise analyses showed that the model tended to follow flow behavior patterns exhibited in the experiment. Beyond this study, this model will be iterated upon and experimentally validated to further examine HECC performance.

centrifugal compressor↗

GT2024-139262: Development of a Computational Fluid Dynamics Model for a High-Speed Centrifugal Compressor

Computational fluid dynamics (CFD) has become widely used in the design and analysis of turbomachinery components such as centrifugal compressors. However, CFD is only a limited representation of experimental cases and struggles to model complex flows or lack model details to increase computation speed. The High Efficiency Centrifugal Compressor (HECC) was designed by United Technologies Research Center for NASA to investigate the difficulties behind improving centrifugal compressor technology and to provide an open case to the turbomachinery research community. The CFD technology seen in previous numerical models of the compressor have improved since then. In this study, a high-fidelity computational model for the vaneless configuration of HECC operating at its design point was developed and compared to an equivalent experimental case. This model incorporated GPU versions of mesh generation code WAND and solver code LEO from AeroDynamic Solutions, Inc. Blade sections extracted from the solid model formed the basis of the impeller mesh, while the remainder of the stage was modeled as ducts. Standard day aerodynamic conditions, design rotational speed, design mass flow rate, and inlet flow angles served as additional inputs. A mesh sensitivity study was performed prior to using the model for analysis. The accuracy of the model’s predictions of impeller and stage performance were assessed by comparing the total pressure ratio, total temperature rise ratio, and adiabatic efficiency to the corresponding parameters observed in the experimental case. Results showed a general overprediction of compressor performance by the model. Predictions were more accurate for the impeller performance compared to those for the full compressor stage. Spanwise analyses showed that the model tended to follow flow behavior patterns exhibited in the experiment. Beyond this study, this model was used to examine HECC aerodynamics and performance in research following thereafter.

centrifugal compressor↗

Direct observation of coherence transfer and rotational-to-vibrational energy exchange in optically centrifuged CO2 super-rotors

Abstract Optical centrifuges are laser-based molecular traps that can rotationally accelerate molecules to energies rivalling or exceeding molecular bond energies. Here we report time and frequency-resolved ultrafast coherent Raman measurements of optically centrifuged CO 2 at 380 Torr spun to energies beyond its bond dissociation energy of 5.5 eV ( J max = 364, E rot = 6.14 eV, E rot / k B = 71, 200 K). The entire rotational ladder from J = 24 to J = 364 was resolved simultaneously which enabled a more accurate measurement of the centrifugal distortion constants for CO 2 . Remarkably, coherence transfer was directly observed, and time-resolved, during the field-free relaxation of the trap as rotational energy flowed into bending-mode vibrational excitation. Vibrationally excited CO 2 ( ν 2 > 3) was observed in the time-resolved spectra to populate after 3 mean collision times as a result of rotational-to-vibrational (R-V) energy transfer. Trajectory simulations show an optimal range of J for R-V energy transfer. Dephasing rates for molecules rotating up to 5.5 times during one collision were quantified. Very slow decays of the vibrational hot band rotational coherences suggest that they are sustained by coherence transfer and line mixing.

74 ATOMIC AND MOLECULAR PHYSICS↗

Submersible Multistage Centrifugal Pump for Versatile Test Reactor Cartridge Test Loop

Submersible multistage centrifugal pumps are ideal for pumping in narrow confined spaces and achieving necessary head pressures and flow rates. Once a diameter is determined then manipulation of the number of stages and motor speed are all that are required to meet desired flow conditions. The Versatile Test Reactor (VTR) closed loop cartridge systems will need forced convection cooling independent of the main reactor. A multistage centrifugal pump can meet the necessary flow rates and pumping pressures while minimizing space taken. The pump considered for this work was based off a deep well submersible pump, a variation of a multistage centrifugal pump. We experimented with two pump sizes, 5 cm (2 inch) and 7.5 cm (3 inch) diameters. These diameters were chosen to fit into the inner diameter of standard 5 and 7.5 (2 and 3 inch) Schedule 40 pipe, respectively. This made the design for the test loop both simpler and less expensive as the need for an engineered pump housing was eliminated. Initial test cartridge planning indicated space for only a 5 cm (2 inch) diameter pump, though early testing of this size showed the need for an abnormally high-speed and high-power motor. Fine tuning of the cartridge design allowed a pump size increase to 7.5 cm (3 inches), which was the pump size most extensively tested in this work. The test loop is composed of various sizes of PVC and aluminum piping components in a loop configuration. The pump is driven by a Pittman 250 W (1/3 horsepower) electric motor with maximum speed of 3,450 RPM. Testing consisted of running the pump at a constant motor speed while varying a control valve to restrict flow through the loop, with differential pressure and flow rate recorded. This was done for one and two stage configurations for the 5 cm (2 inch) diameter impeller design and one, two, and three stage configurations for the 7.5 cm (3 inch diameter) impeller design, respectively. Due to pumping power requirements, two and three stage 7.5 cm (3 inch) diameter impeller testing at higher flowrates lowered the motor speed substantially. In regions where motor speed could not be maintained constant, the data were discarded. The test loop was also reconfigured to allow for the pump to be tested for pressure drop in a stalled or inoperable (0 RPM) flow condition. Demonstration of adequate natural convection cooling of the test cartridge fuel type is necessary under accident conditions, and this will depend upon the flow resistance through the impeller assembly when the pump is not operating. Thus, accurate knowledge of the effective impeller assembly loss coefficient is important for safety evaluations. The test loop was modified to provide water inlet and outlets on either side of the pump impeller stack, and a metered flow of lab water was provided in order to measure the pressure drop across the cartridges as a function of flowrate. Data from the pump head curve testing developed as part of this work and supported by analysis using pump head affinity laws indicates that a three stage 7.5 cm (3 inch) pump impeller design will meet target requirements for coolant flow within the VTR cartridge sodium cartridge at full power conditions [1] with margin; this corresponds to a flowrate of 45 l/min (12 gpm) at a pressure drop of 6.1 m (20 feet) of water head. The results of the pressure loss measurements across the impeller assembly when the pump is stationary (i.e., at 0 RPM) indicate that the pressure loss coefficient is 0.921 for a two impeller stack configuration; this value is calculated based on the flow velocity through the minimum available flow area within a single stage of the impeller which corresponds to 1.4 cm2.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗