Search NASA⌕ Search

SEARCH · Search NASA

Results for “chemical detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Countering Weapons of Mass Destruction Office (CWMD) Data Categorization Study: Chemical, Biological, Radiological, and Nuclear (CBRN) Detection Device Data

Pacific Northwest National Laboratory (PNNL) seeks to address critical questions related to chemical, biological, radiological, and nuclear (CBRN) detection devices. This research aims to enhance the security and understanding of these devices by investigating various aspects of their identification, communication, and functionality. The primary focus is on network security, malware detection, device identification, and intelligence gathering. CBRN data can be categorized in various ways depending on the purpose of CBRN detection devices and the specific context of the applications for analysis. Criteria that can be used to assist in this effort include but are not limited to data type, data protocol, source/destination, application, time, security, and content. This study will inform additional paths for data classification, data profiling, data mapping, and data modeling. This will help the Countering Weapons of Mass Destruction Office (CWMD) better understand their data and make informed decisions based on the insights gained from this study and their application. The CBRN Data Categorization study will include the identification of 5–10 different CBRN detection devices with unique characteristics for assessing and analyzing the data that is being produced by and transmitted from these devices.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Ambient ion focusing from a field-free region to a detector: enhanced signal for explosives and drug detection with mass spectrometry

This study demonstrates ion focusing at ambient pressure and increased ion signal by creating a voltage gradient from a field-free region to a detector, thereby improving the detection of chemicals, such as explosives and drugs. At ambient pressure, ion loss and resulting signal reduction pose challenges that limit detection sensitivity in analytical instruments. Techniques to increase sensitivity, such as atmospheric flow tube-mass spectrometry (AFT-MS), extend ion-molecule reaction times but result in significant overall ion loss due to diffusion. Ion manipulation techniques, though challenging at ambient pressure, can mitigate these losses by concentrating ions toward the detector inlet. Using SIMION, ion trajectories were modeled with a voltage gradient applied between a flow tube and a detector, revealing ion focusing at ambient pressure. Experimental verification with an atmospheric flow tube employed both mass spectrometry and Faraday plate detectors to measure ion beam profiles across varying flow rates, tube diameters, and voltage gradients. Application of a voltage gradient effectively directed ions to the axial center of the flow tube, narrowed ion beam width, and increased signal intensity by 5 to 10 times compared to conditions without a voltage gradient. This ion focusing approach shows promise for improving sensitivity in ambient-pressure instruments. This technique has the potential to enhance detection levels in security and forensic applications, with particular benefits for field-portable devices used at checkpoints to identify explosives and drugs.

ambient pressure↗

Zero Trust Strategies for Chemical, Biological, Radiological, and Nuclear Detection Systems: D.1 Cyber Scenarios

The evolving landscape of cybersecurity necessitates a paradigm shift to a Zero Trust (ZT) model, which assumes breaches and continuously verifies trust. This approach reshapes how trust boundaries are established, focusing on identities, devices, networks, applications, and data, rather than solely relying on perimeter defenses such as firewalls. Central to this transformation is the National Institute of Standards and Technology's (NIST) Special Publication 800-207, outlining the Zero Trust Architecture (ZTA), along with Executive Order 14028, which mandates federal agencies to adopt ZT principles. Complementary to these efforts, the Cybersecurity and Infrastructure Security Agency (CISA) developed the Zero Trust Maturity Model (ZTMM), providing a framework with five pillars and three cross-cutting capabilities to guide agencies toward enhanced cybersecurity maturity. In support of these initiatives, the DHS Countering Weapons of Mass Destruction Office (CWMD) is applying ZT principles to secure Chemical, Biological, Radiological, and Nuclear (CBRN) detection systems. Recognizing the diverse deployment models and network connectivity of these systems—from stationary, non-networked units to mobile, cloud-connected devices—the Pacific Northwest National Laboratory (PNNL) is developing cybersecurity scenarios specifically for CBRN environments. These scenarios examine various configurations and technological capabilities, offering insights into the application of ZTMM pillars in enhancing the security postures of CBRN devices. The cybersecurity scenarios presented by PNNL are hypothetical, crafted to explore theoretical situations and stimulate discussion on the potential use or compromise of CBRN detection systems in varied contexts. These narratives are illustrative and do not reference any real events or actual networks. Instead, they employ generalized reference models to highlight concepts and potential issues within CBRN security, focusing on how Zero Trust strategies can be adapted to address these challenges effectively.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Tri-molybdenum phosphide (Mo 3 P) and multi-walled carbon nanotube junctions for volatile organic compounds (VOCs) detection

Detection and analysis of volatile organic compounds' (VOCs) biomarkers lead to improvement in healthcare diagnosis and other applications such as chemical threat detection and food quality control. Here, we report on tri-molybdenum phosphide (Mo3P) and multiwalled carbon nanotube (MWCNT) junction-based vapor quantum resistive sensors (vQRSs), which exhibit more than one order of magnitude higher sensitivity and superior selectivity for biomarkers in comparison to pristine MWCNT junctions based vQRSs. Transmission electron microscope/scanning tunneling electron microscope with energy dispersive x-ray spectroscopy, x-ray diffraction, and x-ray photoelectron spectroscopy studies reveal the crystallinity and the presence of Mo and P elements in the network. The presence of Mo3P clearly enhanced the performance of vQRS as evidenced in sensitivity and selectivity studies. The vQRSs are stable over extended periods of time and are reproducible, making them a potential candidate for sensing related applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comprehensive Chemical Fingerprinting by Multidimensional GC and Supervised Machine Learning

This project leverages advances in machine learning based data analysis techniques and untargeted omic analytical methods to progress nuclear nonproliferation technologies beyond current capabilities. The developed approaches can be used to identify and detect complex chemical fingerprints of facilities of interest. These techniques have been developed for fields such as metabolomics and genomics but have not been applied to nuclear nonproliferation applications. Adaptation of these techniques for volatile organic compound analysis has far reaching application within the scientific community including environmental chemistry, atmospheric physics, and climate sciences.

97 MATHEMATICS AND COMPUTING↗

Self-contained, automated, long-term sensor system for monitoring of soil and water nutrients in fields

An automated, fieldable ion-selective sensor system for frequent detection of nutrients in soils or water is set forth. In one aspect, an integrated small form-factor housing includes a battery, processor, a fluid manipulation unit and reservoirs, and a chemical species detection cell. A flow-through sampling head can be connected to the detection cell and a waste reservoir by flexible tubing sealingly connected at opposite ends of the tube. In one aspect, improved performance of the ion-selective sensor includes adding an ion-to-electron transfer interlayer between an ion-selective membrane and its working electrode. In one aspect, the sensor is solid-state and uses printed polymeric composite of POT-MoS$_{2}$. The use of a porous tube for a sampling head and fluid connection at opposite ends allows not only fluid to be removed from the head to the detection cell for measurement but also flow in an opposite direction and out to a waste reservoir to clean and reset for a next sample measurement.

60 APPLIED LIFE SCIENCES↗

Standoff Detection of Oil and Powder Mixtures at 12 Meters Using a Tunable Quantum Cascade Laser-Based System with a Close Focus Telescope and Uncooled Infrared Detector

We have designed and demonstrated a quantum cascade laser (QCL) based standoff system that utilizes an uncooled mercury cadmium telluride (MCT) detector with lock-in signal processing for chemical identification at a distance of 12.5 meters in indoor ambient light conditions. In the system, a tunable quad-QCL operating (1 MHz) in quasi-continuous wave mode between 8.45 and 10.03 μm (~1182 to 1000 cm –1 ) serves as the active mid-infrared source for remotely interrogating mineral, powder, and thin film oil samples including powder mixtures (6, 12.5, 25, and 50%) of crystalline quartz (SiO 2 ) in KBr. Light as reflected from a given sample is collected using a 10-inch (25.4 cm) Dall Kirkham telescope and coupled with ZnSe optics to an uncooled MCT detector. Furthermore, the mixture dependence of the highly transparent KBr and strongly absorbing quartz was found to fit a modified version of the Schatz reflectance model for compacted powder mixtures. All reflectance spectra reported are relative to an Au-coated diffuse reflector. A NIST traceable polystyrene standard reflector was also used to determine the QCL wavelength tuning range and calibration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bio-distribution and deposition of wildfire smoke chemicals into olfactory bulb and brain of rats after intranasal instillation

Epidemiological and experimental studies suggest wildfire smoke is a potential contributor to neurological dysfunction and associated with neuroinflammation. Using doses comparable to those encountered during intense wildfire events (200-300 μg/m 3 ), we explore the absorption, distribution, metabolism, and elimination (ADME) and pharmacokinetics of representative members of major chemical classes (acid, phenol, PAH, aldehyde) in inhaled wood smoke condensates. Male Sprague Dawley rats were intranasally instilled with smoldering eucalyptus woodsmoke extract (WSE) reconstituted in saline spiked with 14 C-labeled palmitic acid (PA), benzo[a]pyrene (B[a]P), catechol (CAT) or benzaldehyde (BZ). Serum was collected from 5 min to 2 weeks after exposure and tissues were collected at 0.5, 2, 4, 24 h and 2 weeks after exposure. Urine was collected over the 24 h exposure. Tissues were collected, rinsed in PBS and analyzed by accelerator mass spectrometry (AMS) for 14C-labeled chemicals. PA and B[a]P entered circulation slowly, reached maximum concentration (C max ) near 15 ng/mL at 2 h, and had circulating concentrations near 1/3 C max 24 h after exposure. CAT and BZ rapidly entered circulation and were mostly cleared at 2 h. Excess 14 C from all four chemicals was detected in olfactory bulb and brain over the first 24 h but only PA (or its metabolites) was retained in olfactory bulb, brain and kidney at 2 weeks post exposure. All excess 14 C was cleared from the lung at 2 weeks. Metabolite analysis of urine (CAT, BZ and B(a)P) dosed samples did not detect any parent compound. CAT and BZ were rapidly cleared. The slower uptake and clearance of PA or B[a]P or their reactive metabolites when dosed with WSE in brain and olfactory bulb potentially provide greater opportunity for inflammatory response. This study suggests that wildfire smoke chemicals can enter the brain directly from the nasal cavity to the olfactory bulb and via systemic circulation.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Assessing Metal Ion Assignment Accuracy in Protein Data Bank Models via Elemental Spectroscopy

Accurate representation of metal ions in macromolecular structures is critical for chemical interpretation, computational modeling, and machine-learning methods that rely on Protein Data Bank (PDB) entries. However, the elemental identity of metals modeled in crystallographic structures is often inferred indirectly and rarely validated experimentally. Here, we combine Particle Induced X-ray Emission (PIXE) and X-ray Fluorescence Spectroscopy (XRFS) to determine the elemental composition of protein samples used to generate 70 deposited metalloprotein crystal structures. By analyzing the original protein material employed for crystallization, but before the addition of crystallization buffer solutions, we assess whether the modeled metal ions in deposited structures are consistent with experimentally detectable elemental content. We find that in a majority of cases, the metals modeled in the corresponding PDB entries are inconsistent with the metals present in the protein samples before crystallization, or that additional metals are present but not represented in the structural models. Spectroscopic results were integrated with automated crystallographic validation metrics, including real-space Z-difference (RSZD) analysis and systematic rerefinement, to evaluate atomic-number mismatch at metal sites. PIXE and XRFS show strong agreement for dominant elemental signals and provide complementary, scalable approaches for identifying suspect metal assignments. This work does not address physiological or functional metalation but instead highlights a widespread data integrity issue in deposited macromolecular structures, PDB-wide. These results establish an experimentally corroborated link between elemental identity and crystallographic validation metrics, enabling the large-scale detection of chemically inconsistent annotations in structural databases used for computational modeling and machine learning.

Crystallization↗

Developing Digital Twin Visualizations: A Methodology and Case Study on Chemical Separation Processing

As advances in digital engineering continue to push the technological boundaries, digital twin (DT) visualizations for diagnostics and safeguards advancement become much more feasible and practical. DTs generate large and complex data streams that require effective user interfaces to provide monitoring and diagnostic capabilities. Unfortunately, while these frameworks exist, there is not much research on the systematic documentation of human–computer interaction (HCI) for DT visualization. This work presents a dual-mode visualization methodology (two dimensional [2D] graphical user interface dashboard and 3D mixed reality) designed to support diagnostic tasks in DT systems and building on a validated framework and applying established HCI principles. The methodology is demonstrated through a case study of aqueous processing at Idaho National Laboratory, using experimental data from the chemical solvent extraction runs. Our interfaces display real-time alerts and monitoring to inform users of safeguards anomalies. The interfaces use immersive 3D mixed-reality visualization for further system and experiment investigation. This work demonstrates how the systematic application of HCI principles can inform DT visualization design for diagnostic and safeguards applications. While formal user evaluation studies remain as future work, this paper documents the systematic design methodology and demonstrates a proof-of-concept implementation.

3D visualization↗

Practical benzylation of N,N -substituted ethanolamines related to chemical warfare agents for analysis and detection by Electron Ionization Gas Chromatography-Mass Spectrometry

The benzylation of three, low-molecular weight N,N-disubstituted ethanolamines related to chemical warfare agents (CWAs) to furnish derivatives with improved Gas Chromatography-Mass Spectrometry (GC-MS) profiles is described. Due to their low molecular weight and polar nature, N,N-disubstituted ethanolamines are notoriously difficult to detect by routine GC-MS analyses during Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency tests (PTs), particularly in scenarios when they are present at low levels (~1-10 ppm) amidst more abundant interferences. Our studies revealed that the optimal derivatization conditions involved the treatment of the ethanolamine with benzyl bromide in the presence of an inorganic base (e.g., Na 2 CO 3 ) in dichloromethane at 55 °C for 2 hours. This optimized set of conditions were then successfully applied to the derivatization of N,N-dimethylethanolamine, N,N-diethylethanolamine and N,N-diisopropylethanolamine present separately at 1 and 10 μg/mL concentrations in a glycerol-rich matrix sample featured in the 48 th OPCW PT. The benzylated derivatives of the three ethanolamines possessed retention times long enough to clear the massive glycerol-containing matrix interferences. In conclusion, the protocol herein is introduced as an alternative method for derivatization of these CWA and pharmaceutically important species and should find broad applicability in laboratories where their routine forensic analysis is carried out.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reducing ion diffusion at atmospheric pressure through intermingled positive and negative ions

Increasing ion molecule reaction times for ambient ionization techniques can increase sensitivity of detection. Longer reaction times result in an increase in analyte signal relative to the reactant ion signal, however with a subsequent decrease in the total ion intensity. This loss in the total number of ions reaching the detector limits the extent to which increased reaction time can improve detection in practical applications. In this study ion loss was measured using either electric fields or gas flow to control ion transit time. Ion transit times ranged from 40 ms to 8s, which resulted in ion densities ranging from 5 x 10 6 to 2 x 10 4 ions/cm 3 , respectively. These results provide insights into practical reaction time limitations or experimental boundaries when exploring sensitivity enhancements in ambient ionization. When exploring longer reaction times with an atmospheric flow tube coupled to a mass spectrometer (AFT-MS), an additional corona discharge ionization source of the same polarity was added in an attempt to increase total ion signal, but no improvement in signal was observed. This observation suggested that there was a maximum ion density being reached by the corona discharge that could not be increased by adding more of the same polarity ions. A hypothesis was that intermingling both polarities of ions would reduce ion loss and increase the measured ion signal. When two corona discharge sources—one each of positive and negative polarity—were used simultaneously in an AFT-MS, the total ion signal of either polarity measured by the MS was approximately double the current from a single corona discharge source. An increase in the negative ion signal was also observed when ~10 parts-per-trillion vapor levels of an explosive (RDX) were introduced. In this case both the nitrate reactant ions and the RDX signal more than doubled with the addition of a corona discharge source producing positive ions. When intermingling positive and negative ions, an increase in ion current was also observed when the AFT was coupled directly to a Faraday detector or to an ion mobility spectrometer. This was the first demonstration of interfacing the AFT to an IMS. The observations and developments from this work will help in creating more portable instruments with improved sensitivity for detection of chemicals.

47 OTHER INSTRUMENTATION↗

Self-Assembled Bolaamphiphile-Based Organic Nanotubes as Efficient Cu(II) Ion Adsorbents

Self-assembled organic nanotubes (ONTs) have been actively examined for various applications such as chemical separations and catalysis owing to their well-defined tubular nanostructures with distinct chemical environments at the wall and internal/external surfaces. Adsorption of heavy metal ions onto ONTs plays an essential role in many of these applications, but it has rarely been assessed quantitatively. Herein, we investigated interactions between Cu 2+ and single-/quadruple-wall bolaamphiphile-based ONTs having inner carboxyl groups with different inner diameters, COOH-ONT 10nm and COOH-ONT 20nm . We first examined the effects of Cu 2+ on their nanotubular structures using SAXS, STEM, and AFM. COOH-ONT 10nm was stable in aqueous Cu 2+ solution in contrast to COOH-ONT 20nm owing to the presence of polyglycine-II-type hydrogen bonding networks within its wall. Subsequently, we studied the Cu 2+ adsorption behavior of COOH-ONT 10nm by monitoring the concentration of unbound Cu 2+ using linear sweep anodic stripping voltammetry. The Cu 2+ adsorption was quick, attributable to efficient Cu 2+ partitioning through the open ends of the ONT, followed by fast Cu 2+ diffusion in the uniform, relatively large nanochannel. More importantly, the Cu 2+ adsorption capacity and affinity of COOH-ONT 10nm were measured at different pH using the Langmuir adsorption model. The adsorption capacity was similar at the pH range examined, showing the participation of approximately 25% of the inner carboxyl groups in the adsorption. The adsorption affinity increased with pH, indicating the essential role of the deprotonated carboxyl groups in the Cu 2+ adsorption. Most interestingly, the Langmuir adsorption constant was significantly higher than those of previously reported synthetic adsorbents and planar monolayer based on carboxyl binding sites. The high Cu 2+ affinity of the ONT was attributable to the highly dense binding sites on the well-defined nanoscale concave structure of the inner channel. Furthermore, these results provide a valuable guideline to designing self-assembled nanomaterials for efficient chemical separations, detection, and catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chapter 13: Time-of-Flight Secondary-Ion Mass Spectrometry and Atom Probe Tomography

Time-of-flight secondary-ion mass spectrometry (TOF-SIMS) and atom probe tomography (APT) have many similarities. Both detect the chemical makeup of a solid material at ppm or better sensitivity, while retaining the spatial location information from the signal. Both use a similar principle to measure a signal associated with a given charged secondary ion—the flight time it takes a secondary ion to reach the detector after it is generated. Both are destructive techniques—albeit destructive of very small volumes—because the signal measured is generated by the removal of material from the sample itself. Importantly, both techniques require ultra-high vacuum (UHV) to ensure that the secondary ions, once generated, can reach the detector without collision with other atoms in the gas phase. In the case of TOF-SIMS, the samples can vary from several mm to several inches in size, whereas for APT, the samples are cones several hundred microns in size that are prepared in a special manner (covered in detail later in the chapter). We will discuss the basic fundamentals of each technique and cover several examples of the technique applied to photovoltaic materials, which should give a good idea of the types of information one can gain from TOF-SIMS and APT and how they are complementary as they both operate at different length scales: at the hundreds of microns to hundreds of nanometer scale for TOF-SIMS and at the nanometer to a few angstroms scale for APT.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Evidence of Dirac Quantum Spin Liquid in YbZn 2⁢ GaO 5

The emergence of a quantum spin liquid (QSL), a state of matter that can result when electron spins are highly correlated but do not become ordered, has been the subject of a considerable body of research in condensed matter physics [1,2]. Spin liquid states have been proposed as hosts for high-temperature superconductivity [3] and can host topological properties with potential applications in quantum information science [4]. The excitations of most quantum spin liquids are not conventional spin waves but rather quasiparticles known as spinons, whose existence is well established experimentally only in one-dimensional systems; the unambiguous experimental realization of QSL behavior in higher dimensions remains challenging. Here, in this work, we investigate the novel compound $YbZn_{2}GaO_{5}$, which hosts an ideal triangular lattice of effective spin-1/2 moments with no detectable inherent chemical disorder. Thermodynamic and inelastic neutron scattering measurements performed on high-quality single crystal samples of $YbZn_{2}GaO_{5}$ exclude the possibility of long-range magnetic ordering down to 0.06 K, demonstrate a quadratic power law for the specific heat and reveal a continuum of magnetic excitations in parts of the Brillouin zone. Both low-temperature thermodynamics and inelastic neutron scattering spectra suggest that $YbZn_{2}GaO_{5}$ is a U(1) Dirac QSL with spinon excitations concentrated at certain points in the Brillouin zone. We advanced these results by performing additional specific heat measurements under finite fields, further confirming the theoretical expectations for a Dirac QSL on the triangular lattice of $YbZn_{2}GaO_{5}$.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimal spectral resolution for solids and liquids using FT and other infrared spectrometers: How much resolution do you really need?

In this study we investigate the possibility of using spectral resolutions for infrared measurements of solids and liquids that are not powers of two, e.g. are not at 1, 2, 4, 8, or 16 cm-1 resolution. In almost all reported literature of the last fifty years the resolution used to record for a Fourier transform infrared spectrum has been a power of two. This stems from the fact that 1) the Cooley-Tukey algorithm used to compute such a transform was constructed to use only powers of two and was also driven by 2) the fact that the computing horsepower required to compute the Fourier transform increases as N?log?_2 (N), where N is the number of points in the interferogram (spectrum). For typical spectra, however, the CPU time is no longer a consideration. Our study is based on both liquid and solid spectra, all of which were recorded at 2 cm-1 resolution. There were at total of 70 solids spectra representing 2,472 spectral peaks and 61 liquids spectra (1,765 spectral peaks), each peak being inspected for being singlet / multiplet in nature. Of the 1,765 liquid bands examined, only 27 had widths less than 5 cm-1. Of the 2,472 solid bands examined, only 39 peaks have widths less than 5 cm-1. For liquids, the mean peak width is 24.7 cm-1 but the median peak width is 13.7 cm-1, and, similarly, for solids, the mean peak width is 22.2 cm-1 but the median peak width is 11.2 cm-1. In both cases, solids and liquids, a skewed peak widths distribution was observed, the peak of the distribution representing narrower bands in the 7 to 9 cm-1 FWHM range but displaying a long tail to the very broad bands, with some displaying spectral widths of 100 cm-1 or more. Because one of the most important criteria for successful instrumental design in IR spectroscopy is the spectral resolution, the data were further analyzed showing that a value to resolve 95% of all bands is 5.7 cm-1 for liquids and 5.3 cm-1 for solids; such a resolution would capture the native linewidth (no instrumental broadening) of 95% of all the solids and liquid bands, respectively. Based on the present results we suggest that, when accounting only for intrinsic linewidths an optimized resolution of 6.0 cm-1 will capture 91% of all condensed-phase bands for IR detection of chemical, mineral, and biological materials.

Forland, Brenda M.↗

Deriving the Infrared Complex Refractive Indices of Organic Powders for Optical Modeling: Comparison of Methods

Identification of solids via infrared reflection spectroscopy requires a spectral library of all solids likely to be encountered. A confounding factor in populating such a spectral library is that the reflectance spectra of solids vary with their form, including particle size, film thickness, and substrate. To reduce the efforts of experimentally constructing such a library, an alternate strategy is to use the wavelength-dependent optical constants, n and k, of a solid to calculate a series of reflectance spectra corresponding to each scenario or morphology. Because most n/k measurements are best performed on mm-sized crystals, however, the challenge of determining the optical constants increases when a solid is only readily available as a powder, as is often the case. Some organic solids, such as caffeine, are both unavailable in large crystals and difficult to press into pellets. In this study, the infrared optical constants, or complex refractive indices, of caffeine were determined using three different methods: single-angle reflectance, infrared spectroscopic ellipsometry, and quantitative absorbance measurements of KBr pellets. The n and k values derived through each method were used to model the hyperspectral imaging reflectance spectrum of a caffeine film on a steel planchet. Over 1,110 – 870 cm-1, the single-angle reflectance-derived n and k had the best correlation with the experimental spectrum. These results suggest different organic solids may require different methods to determine the most accurate infrared complex refractive indices for synthetic spectral libraries.

FTIR, hyperspectral imaging, infrared, infrared (I↗