Search NASA⌕ Search

SEARCH · Search NASA

Results for “cold temperatures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development and Application of High-Fidelity Models for Heterogeneous CO2 Frost Formation

Carbon America has developed a cryogenic carbon capture technology ("FrostCC") that separates CO2 from point source emissions by solidifying it at cold temperatures through preferential desublimation. Cooling is achieved through a series of interlinked compression, heat exchange, and expansion operations. In the current system, frosting of CO2 happens in heat exchangers, followed by CO2 recovery in a separate extraction step. In this work, multiphysics computational fluid dynamics (CFD) models are developed and validated for compressible and low Mach flows to simulate the formation of solid CO2 in flue gas flowing in a heat exchanger geometry. The models track the mass transfer rate of CO2 from gas phase to solid phase, heat released from desublimation, and the evolution of the solid CO2 layer. Simulations are used to answer scientific questions related to the angle of heat exchanger pipes, where buoyancy effects from flow velocity and pipe orientation influence CO2 frosting. Results show that upwardly angled pipes produce notably different flow structures compared to horizontal or vertical configurations, and that carbon capture efficiency correlates with buoyancy effects for pipe angles within plus or minus 23 degrees of horizontal.

97 MATHEMATICS AND COMPUTING↗

Energy Cost Analysis and Operational Range Prediction Based on Medium- and Heavy-Duty Electric Vehicle Real-World Deployments across the United States

While the market for medium- and heavy-duty battery-electric vehicles (MHD EVs) is still nascent, a growing number of these vehicles are being deployed across the U.S. This study used over 2.3 million miles of operational data from multiple types of MHD EVs across various regions and operating conditions to address knowledge gaps in total cost of ownership and operational range. First, real-world energy cost savings were determined: MHD fleets should experience energy cost savings each year from 2021 to 2035, regardless of vehicle platform, with the greatest savings seen in transit buses (up to USD 4459 annually) and HD trucks (up to USD 3284 annually). Second, to help fleets across various geographies throughout the U.S. assess the suitability of EVs for their year-round operating needs, operational range was modeled using the XGBoost algorithm (R2: 70%) given 22 input features relevant to vehicle efficiency. Finally, this paper recommends (1) that MHD fleets apply energy-saving practices to minimize the impacts of cold temperatures and high congestion levels on vehicle efficiency and range, and (2) that local hauling fleets select trucks with a nominal range nearly double the expected maximum daily range to account for range losses under local, urban driving conditions.

Qiu, Yin (ORCID:0009000900948794)↗

Development and evaluation of a new 4DEnVar-based weakly coupled ocean data assimilation system in E3SMv2

The development, implementation, and evaluation of a new weakly coupled ocean data assimilation (WCODA) system for the fully coupled Energy Exascale Earth System Model version 2 (E3SMv2) utilizing the four-dimensional ensemble variational (4DEnVar) method are presented in this study. The 4DEnVar method, based on the dimension-reduced projection four-dimensional variational (DRP-4DVar) approach, replaces the adjoint model with the ensemble technique, thereby reducing computational demands. Monthly mean ocean temperature and salinity data from the EN4.2.1 reanalysis are integrated into the ocean component of E3SMv2 from 1950 to 2021 with the goal of providing realistic initial conditions for decadal predictions and predictability studies. The performance of the WCODA system is assessed using various metrics, including the reduction rate of the cost function, root mean square error (RMSE) differences, correlation differences, and model biases. Results indicate that the WCODA system effectively assimilates the reanalysis data into the climate model, consistently achieving negative reduction rates of the cost function and notable improvements in RMSE and correlation across various ocean layers and regions. Significant enhancements are observed in the upper ocean layers across the majority of global ocean regions, particularly in the north Atlantic, north Pacific, and Indian Ocean. Model biases in sea surface temperature and salinity are also substantially reduced. For sea surface temperature, cold biases in the north Pacific and north Atlantic are diminished by about 1–2 °C, and warm biases in the Southern Ocean are corrected by approximately 1.5–2.5 °C. In terms of salinity, improvements are observed with bias reductions of about 0.5–1 psu in the north Atlantic and north Pacific and up to 1.5 psu in parts of the Southern Ocean. The ultimate goal of the WCODA system is to advance the predictive capabilities of E3SM for subseasonal to decadal climate predictions, thereby supporting research on strategic energy-sector policies and planning.

54 ENVIRONMENTAL SCIENCES↗

Leipzig University W-Band Cloud Radar, Gothic (Colorado), SAIL Campaign Second Winter (15.11.2022 - 05.06.2023)

The instrument is a polarimetric W-Band simultaneous transmission simultaneous reception (STSR) Doppler Cloud Radar manufactured by Radiometer Physics GmbH (RPG, instrument type RPG-FMCW-94-DP). It was deployed about 500m away from the ARM M1 facility in Gothic (CO) near the Ore House between Nov 15, 2022 and Jun 5, 2023 at an altitude of 2913 m. The Doppler cloud radar was mounted on a prototype of a cold temperature scanner manufactured by RPG. The dataset contains common radar variables like equivalent radar reflectivity factor, mean Doppler velocity, Doppler spectrum width as well as common polarimetric radar variables like differential phase shift (PhiDP), specific differential phase shift (KDP), correlation coefficient (RHV) and differential reflectivity (ZDR). Between Nov 15, 2022, and Feb 7, 2023 the radar was operated at 40° constant elevation and 151° azimuth (towards the KAZR at the AMF1). Between Feb 7 and Mar 15, 2023 the following scan cycle was repeated in 15min intervals: zenith pointing measurements, RHI scans from 0° to 90° and 90° to 0° elevation at 151° azimuth, constant elevation measurements at 40° elevation and 151° azimuth and PPI scans at 85° elevation for wind retrievals (one PPI per hour). Between Mar 15 18:18 UTC and Apr 8, 2023 11:04 UTC, the scanner was stuck at 72° elevation, which resulted in corrupted files for this period. For that period, the files containing data are uploaded but should be treated with care. Between Apr 8 and Apr 14, 2023 the scanning pattern described above was performed again. Afterwards, except for May 17 and May 18, 2023 where scanning patterns as described above were performed, measurements continued at 40° elevation and 151° azimuth until May 22, 2023 09:00 UTC. The scanning pattern was then started again, but without hourly PPI measurements until May 31, 2023. Between May 31 and Jun 5, 2023 solely zenith-pointing observations were performed. The data provided here are the RPG Level 1 (L1) files, Doppler spectra Level 0 (L0) files are available upon request.

54 ENVIRONMENTAL SCIENCES↗

EVs@Scale: NextGen Profiles EVSE Characterization 2025

As part of the U.S. DOE EVs@Scale consortium, the Next-Generation Profiles (NextGen Profiles [NGP]) project presents analysis and results from the characterization of high-power conductive and wireless charging infrastructure. High Power Charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. Electric Vehicle Service Equipment (EVSE) characterization involves testing over a wide range of DC charging currents and voltages during nominal and off-nominal conditions. This testing allows for a better understanding of the impact that high-power charging will have on the electric grid. A common set of standard test plans, procedures, and data requirements were applied to the characterization in this document with minor updates and improvements. This report covers all conductive characterization activities performed between October 2024 and September 2025 on the Delta Electronics 350KW Electric Vehicle Charging System, consisting of power cabinet model EIDN-U350KTA01 and dispenser model EIDD-U350SSUUAEG-350.Key Findings include: Output regulation, Efficiency and power factor, Load management, Grid Resilience, Smart Charge Management (SCM) performance, Thermal control system performance, Multi-port simultaneous charging performance, and Selected performance comparisons with other EVSEs characterized in the NextGen Profiles project. Hot and cold temperature testing was not conducted on the Delta 350KW due to laboratory limitations. Future research could include continued testing the Delta hardware under off-nominal temperature conditions including multi-port/multi-session simultaneous charge testing, in addition to collecting data on other high-power conductive chargers to augment.

25 ENERGY STORAGE↗

Analysis of Frost Prevention for Heat Recovery Ventilation in an Arctic Facility

Sub-Arctic environments present a unique challenge for the continuous operation of mechanical ventilation systems in occupied buildings where cold temperatures create complications for maintaining adequate air quality, efficiency, and system operability. Heat recovery ventilation is most difficult at the coldest temperatures, when there is the greatest availability to transfer heat between airstreams, due to the potential for frost accumulation in the exhaust airstream. Frost limits heat transfer and creates the potential for subsequent blockage of airflow. A successful frost prevention strategy is necessary to ensure that recovery ventilation systems function in locations with a large amount of annual heating degree days. Commonly, this is achieved by preheating outdoor air above freezing temperatures via airflow through a glycol-water mix hydronic coil before heat exchange occurs. Preheating the outdoor air proactively inhibits frost formation but is associated with a penalty to recovery efficiency. A commercial-scale heat recovery ventilator in a facility in Fairbanks, Alaska was analyzed for sensible recovery effectiveness and exhaust temperature at different winter conditions. The system utilized the common defrost strategy of preheating the air above-freezing with a static temperature control scheme. The heat transfer efficiency of the recovery ventilator was observed to be poor at various winter conditions with elevated exhaust temperatures indicating lost heat recovery effectiveness. Using prior findings on strategies for sub-freezing temperatures along with observed field conditions it was determined that a dynamic relationship between the coil and the exterior conditions would reduce the energy required to preheat the air and allow the heat exchanger to maximize effectiveness due to temperate difference. This reduction in preheated temperature of the air is achieved by modulating the temperature of the coil to keep the discharge air stream above a certain dewpoint temperature threshold, likely leading to energy savings for other sub-Arctic facilities using this frost control strategy.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Variability of Water Vapor in the Tropical Middle Atmosphere Observed From Satellites and Interpreted Using SD-WACCM Simulations

Water vapor in the middle atmosphere plays an essential role in global warming, ozone depletion, and the formation of polar stratospheric and mesospheric clouds. We show that tropical middle atmospheric water vapor simulated with the specified-dynamics version of the Whole Atmosphere Community Climate Model (SD-WACCM) is consistent with changes observed in a merged satellite data set, which encompasses the period 1993–2020. Consistent with previous work, we find no significant trend in the stratosphere in either the observations or the simulation; in the mesosphere, we find a long-term trend of 0.1 ppmv per decade, but only in the observations. We also analyze an SD-WACCM simulation for the longer period 1980–2019 to quantify the contribution of various factors to the decadal variation of middle atmospheric water vapor. Over 1980–1995, the simulated water vapor in the upper stratosphere and mesosphere, averaged zonally and over ±30° latitude, increases by 0.30 ppmv per decade due to increasing methane emissions. After 1995, a significant abrupt decrease of water vapor of 0.37 ppmv per decade and then a gradual increase of 0.33 ppmv per decade result from changes in stratospheric cold point temperature. The cold-point temperature is strongly influenced by the strength of the Brewer-Dobson circulation. The acceleration of the Brewer-Dobson circulation before about 2003 leads to a cooler tropical tropopause and a decrease of water vapor, and the deceleration thereafter leads to corresponding warming of the tropopause and an increase in water vapor.

54 ENVIRONMENTAL SCIENCES↗

Ash Fouling Free Regenerative Air Preheater for Deep Cyclic Operation

The University of Kentucky (UKy) project titled “Ash Fouling Free Regenerative Air Preheater for Deep Cyclic Operation”, DE-FE0031757, was conducted from 8/15/2019 to 8/14/2024 in two Budget Periods. Other participants included PPL Corporation and Black Dragon Double Boiler. The overall goal was to investigate the proposed self-cleaning technology to achieve ash fouling free air preheater operation in a coal-fired power plant, especially during deep cycling. All project deliverables, milestones, and success criteria were met. UKy obtained the following scientific findings. • Temporary and periodic high temperature of heating elements (450 ~ 500 °F) can prevent ash accumulation and maintain air preheater free of clogging. • The ash samples analysis and unit operation provide solid evidence of ABS formed during low load with SCR ammonia slip being the major cause of ash accumulation, and air preheater clogging can be prevented by raising the heating element temperature up to 450 °F~ 500 °F at which ABS is decomposed. • In-situ self-cleaning can be controlled by monitoring temperature and/or presetting fixed number of cleanings per day. Both approaches in pilot testing show positive results for maintaining an ash free state for the air preheater. • Temperature criteria (cold end or gas outlet temperature) for entering self-cleaning service is critical to balance the number of cleaning cycles with maintaining the ash level. • Temperature criteria (cold end or gas outlet temperature) for exiting self-cleaning service is critical to balance the duration of the cleaning cycles with maintaining the ash level.

01 COAL, LIGNITE, AND PEAT↗

Cold acclimation threshold induction temperatures of switchgrass ecotypes grown under a long and short photoperiod

Abstract Plants can cold acclimate to enhance their freezing tolerance by sensing declining temperature and photoperiod cues. However, the factors influencing genotypic variation in the induction of cold acclimation are poorly understood among perennial grasses. We hypothesized that the more northern upland switchgrass ( Panicum virgatum L.) ecotype develops a higher degree of freezing tolerance by initiating cold acclimation at higher temperatures as compared with the coastal and southern lowland ecotypes. First, we determined the optimal method for assessing freezing tolerance and the length of exposure to 8/4°C required to induce the maximum level of freezing tolerance in the most northern upland and most southern lowland genotypes. We characterized the maximum freezing tolerance of eight uplands, three coastal and five lowland genotypes grown for 21 days at 8/4°C and a 10 or 16 h photoperiod. Next, we identified the temperature required to induce cold acclimation by exposing the 16 genotypes for 7 days at 20–6°C constant temperatures under a 10 or 16 h photoperiod. Cold acclimation initiated at temperatures 5 and 7°C higher in upland than in coastal and lowland genotypes. Among upland genotypes the shorter photoperiod induced cold acclimation at a 1°C higher temperature. Genotypes originating from a more northern latitude initiate cold acclimation at higher temperatures and develop higher maximum freezing tolerances. An earlier response to declining temperatures may provide the upland ecotype with additional time to prepare for winter and provide an advantage when plants are subjected to the rapid changes in fall temperature associated with injurious frosts.

60 APPLIED LIFE SCIENCES↗

Identification and Characterization of Persistent Cold Pool Events from Temperature and Wind Profilers in the Columbia River Basin

Cold pool events occur when deep layers of stable, cold air remain trapped in a valley or basin for multiple days, without mixing out from daytime heating. With large impacts on air quality, freezing events, and es-pecially on wind energy production, they are often poorly forecast by modern mesoscale numerical weather prediction (NWP) models. Understanding the characteristics of cold pools is, therefore, important to provide more accurate forecasts. This study analyzes cold pool characteristics with data collected during the Second Wind Forecast Improvement Project (WFIP2), which took place in the Columbia River basin and Gorge of Oregon and Washington from fall 2015 until spring 2017. A subset of the instrumentation included three microwave radiometer pro?lers, six radar wind pro?lers with radio acoustic sounding systems, and seven sodars, which together provided seven sites with collocated vertical pro?les of temperature, humidity, wind speed, and wind direction. Using these collocated observations, we developed a set of criteria to determine if a cold pool was present based on stability, wind speed, direction, and temporal continuity, and then developed an automated algorithm based on these criteria to identify all cold pool events over the 18 months of the ?eld project. Characteristics of these events are described, including statistics of the wind speed distributions and pro?les, stability conditions, cold pool depths, and descent rates of the cold pool top. The goal of this study is a better understanding of these characteristics and their processes to ultimately lead to improved physical parameterizations in NWP models, and consequently improve forecasts of cold pool events in the study region as well at other locations that experiences similar events.

McCaffrey, Katherine L.↗

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Insights on seasonal solifluction processes in warm permafrost Arctic landscape using a dense monitoring approach across adjacent hillslopes

Solifluction processes in the Arctic are highly complex, introducing uncertainties in estimating current and future soil carbon storage and fluxes, and assessment of hillslope and infrastructure stability. This study aims to enhance our understanding of triggers and drivers of soil movement of permafrost-affected hillslopes in the Arctic. To achieve this, we established an extensive soil deformation and temperature sensor network, covering 48 locations across multiple hillslopes within a 1 km² watershed on the Seward Peninsula, AK. We report depth-resolved measurements down to 1.8 m depth for May to September 2022, a period conducive to soil movement due to deepening thaw layers and frequent rain events. Over this period, surface movements of up to 334 mm were recorded. In general, these movements occur close to the thawing front, and are initiated as thawing reaches depths of 0.4 to 0.75 m. The largest movements were observed at the top of the south-east facing slope, where soil temperatures are cold (mean annual soil temperatures averaging -1.13°C) and slopes are steeper than 15°. Our analysis highlights three primary factors influencing movements: slope angle, soil thermal conditions, and thaw depth. The latter two significantly impact the generation of pore water pressures at the thaw–freeze interface. Specifically, soil thermal conditions govern the liquid water content, while thaw depth influences both the height of the water column and, consequently, the pressure at the thawing front. These factors affect soil properties, such as cohesion and internal friction angle, which are crucial determinants of slope stability. This underscores the significance of a precise understanding of subsurface thermal conditions, including spatial and temporal variability in soil temperature and thaw depth, when assessing and predicting slope instabilities. Based on our observations, we developed a Factor of Safety proxy that consistently falls below the triggering threshold for all probes exhibiting displacements exceeding 50 mm. This study offers novel insights into patterns and triggers of hillslope movements in the Arctic and provides a venue to evaluate their impact on soil redistribution.

54 ENVIRONMENTAL SCIENCES↗

Do Flashing and Sealant Materials Need to be Exposed to Extreme Cycling?

In the U.S., over 50% of homes were built before 1980, when minimal building codes existed. The aging of building envelopes can significantly contribute to the air leakage, moisture intrusion, and durability of buildings leading to higher energy demands. Although the durability of building materials and envelope systems has been studied extensively, the durability of specific components like window-wall flashing and sealants remains underexplored. Current standards such as ASTM, NIST, and AAMA primarily focus on durability testing considering the high temperatures only and require sealant testing on anodized aluminum panels, leaving questions about performance in cold or fluctuating temperatures unanswered. Current ASTM and AAMA standards provide guidelines for durability testing but predominantly focus on exposure to higher temperature conditions. It remains unclear how exposure to cold temperatures, or cycles of both hot and cold conditions, affect the durability of these materials. Furthermore, AAMA standards mandate that flashing materials be tested on anodized aluminum panels, which may not reflect real-world applications. Therefore, this initial study aims to explore this concern through testing by constructing two window-wall interface prototypes and applying five different flashing and sealant materials to their joints. These samples were subjected to extreme temperatures, ranging from −34 ℃ (−30 °F) to 50 ℃ (122 °F), over a 28-day period (fourteen cycles of 24 hours), with daily visual inspections to document any signs of deterioration such as wrinkling, distortion, or warping. The study has two main objectives: (1) to determine whether flashing and sealant materials lose their durability and strength when exposed to varying climate conditions, specifically cold climates, and (2) to assess whether the interaction of these materials with different substrates (e.g., lumber, PVC, insulation) affects their durability and strength under varying climate conditions. The findings demonstrate how aging impacts the durability of window-wall systems interfaces, justifying future research that potentially could lead to the development of new testing protocols if significant defects are identified.

Palani, Hevar [ORNL] (ORCID:0000000220211994)↗

Viscosity of glass-forming melt at the bottom of high-level waste melter feed cold caps: Effects of temperature and incorporation of solid components

At the final stages of conversion of melter feed (glass batch) to molten glass, the transient glass-forming melt becomes a continuous liquid phase encapsulating dissolving solid particles and gas bubbles that produce primary foam at the bottom of the cold cap (the reacting melter feed in an electric glass melting furnace). The glass-forming melt viscosity plays a dominant role in primary foam formation, stability, and eventual collapse, thus affecting the rate of melting (the glass production rate per cold cap area). For several melter feeds designed for nuclear waste vitrification, we have traced the glass-forming melt viscosity during the final stages of feed-to-glass conversion as it changes in response to changing temperature and composition (resulting from dissolving solid particles). Starting with a relatively low values at the moment when the melt connects, melt viscosity reaches maximum within the primary foam layer and then decreases to its final melter-operating temperature value. We paid a particular attention to the cold-cap bottom—the boundary between the primary foam layer and the thermal boundary layer—where the melt viscosity affects the rate of melting predominantly through its effect on the temperature at which primary foam is collapsing.

Lee, Seung Min↗

Tail Dependence as a Measure of Teleconnected Warm and Cold Extremes of North American Wintertime Temperatures

Current models for spatial extremes are concerned with the joint upper (or lower) tail of the distribution at two or more locations. Such models cannot account for teleconnection patterns of 2-m surface air temperature ( T 2m ) in North America, where very low temperatures in the contiguous United States may coincide with very high temperatures in Alaska in the wintertime. This dependence between warm and cold extremes motivates the need for a model with opposite-tail dependence in spatial extremes. This work develops a statistical modeling framework that has flexible behavior in all four pairings of high and low extremes at pairs of locations. In particular, we use a mixture of rotations of common Archimedean copulas to capture various combinations of four-corner tail dependence. We study teleconnected T 2m extremes using ERA5 of daily average 2-m temperature during the boreal winter. Further, the estimated mixture model quantifies the strength of opposite-tail dependence between warm temperatures in Alaska and cold temperatures in the midlatitudes of North America, as well as the reverse pattern. These dependence patterns are shown to correspond to blocked and zonal patterns of midtropospheric flow. This analysis extends the classical notion of correlation-based teleconnections to considering dependence in higher quantiles.

54 ENVIRONMENTAL SCIENCES↗

The Interaction between the Nocturnal Amazonian Low-Level Jet and Convection in CESM

A nocturnal Amazonian low-level jet (ALLJ) was recently diagnosed using reanalysis data. This work assesses the ability of CESM1.2.2 to reproduce the jet and explores the mechanisms by which the ALLJ influences convection in the Amazon. The coupled CESM simulates the nocturnal ALLJ realistically, while CAM5 does not. A low-level cold air temperature bias in the eastern Amazon exists in CAM5, and thus the ALLJ is weaker than observed. However, a cold SST bias over the equatorial North Atlantic in the coupled model offsets the cold air temperature bias, producing a realistic ALLJ. Climate models significantly underestimate March–May (MAM) precipitation over the eastern Amazon. Here, we ran two sensitivity experiments using the coupled CESM by adding bottom-heavy diabatic heating at noon and midnight for 2.5 h along the coastal Amazon during MAM to mimic the occurrence of shallow precipitating convection. When heating is added during the early afternoon, coastal convection deepens and the ALLJ transports moisture inland from the ocean, preconditioning the environment for deep convective development during the ensuing hours. The increased convection over the eastern Amazon also moderately alleviates the equatorial Atlantic westerly wind bias, leading to deepening of the east Atlantic thermocline in the following months and partially improving the simulated June–August (JJA) Atlantic cold tongue in the coupled model. When heating is added at night, coastal convection does not strengthen as much and the ALLJ transports less moisture. Improvements in the simulated Atlantic winds and SST are negligible. Therefore, diurnal circulations matter to the organization of convection and rain across the Amazon, with impacts over the equatorial Atlantic.

54 ENVIRONMENTAL SCIENCES↗