Search NASA⌕ Search

SEARCH · Search NASA

Results for “column separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Rotating Apparatus for Isoelectric Focusing

Remixing of separated fractions prevented. Improved isoelectric focusing apparatus helps to prevent electro-osmosis and convection, both of which cause remixing of separated fractions. Fractionating column segmented and rotated about horizontal axis: Only combined effects of both features fully effective in making good separations. Improved apparatus slowly rotated continuously or rocked (at rotational amplitude of at least 180 degrees) about its horizontal axis so average gravitational vector experienced by fluid is zero and convection is therefore suppressed. Electro-osmosis suppressed and convection further suppressed by separating column into disklike compartments along its length with filters. Experiments have shown dimensions of apparatus not critical. Typical compartment and column volumes are 2 and 40 ml, respectively. Rotation speeds lie between 3 and 30 rpm.

Bier, M.↗

Development of a slicing device for Apollo-Soyuz Test Project (ASTP) electrophoresis technology experiment MA-011

The electrophoresis of six columns was accomplished on the Apollo-Soyuz test Project. After separation, these columns were frozen in orbit and were returned for ground-based analyses. One major goal of the MA-011 experiment was the assessment of the separation achieved in orbit by slicing these frozen columns. The slicing of the frozen columns required a new device. The development of that device is described.

Nerren, B. H.↗

Static and Dynamic Intensification of Water–Ethylene Glycol Separation Using a Dividing Wall Column

This paper makes several first-of-a-kind contributions toward “double intensification” (static/dynamic) of distillation systems, focusing in particular on the energy-intensive separation of a mixture of water and ethylene glycols. First, we demonstrate that a dividing wall column (DWC) can be an appropriate choice for separating wide-boiling zeotropic mixtures. Additionally, we show that the conventional DWC configuration where the wall is in the “middle” should be discarded in favor of a less frequently encountered “common-bottom” setup. For the mixture considered, choosing a DWC in lieu of a conventional two-column sequence can lead to over 6% energy cost savings and a 5% reduction in the number of stages compared to the conventional direct sequence two-column counterpart. The second part of this paper focuses on applying the previously introduced concept of dynamic process intensification to the DWC, the first time that such an effort is reported in the literature, to our knowledge. Here, we show that an additional 1.4% energy savings can be unlocked in this way, and confirm the stable operation of the column via dynamic simulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrogen Analysis by Gas Chromatography–Mass Spectrometry

The detection of hydrogen in complex gas mixtures is essential for many applications. Conventional approaches such as gas chromatography (GC) with thermal conductivity detection (TCD) and residual gas analyzers (RGAs) face significant limitations: TCD exhibits poor response when helium is used as a carrier gas, whereas RGAs lack chromatographic separation, preventing reliable quantification of hydrogen because of interference from other species. Traditional GC methods rely on dual-column configurations with packed or molecular-sieve porous layer open tubular (PLOT) columns to separate hydrogen from O2, N2, CO, CO2, CH4, and other hydrocarbons, increasing system complexity and limiting compatibility with mass spectrometry (MS) detection. In this work, we developed and validated a robust GC–MS method capable of directly detecting and quantifying hydrogen using electron ionization (EI) without dopants, reagent gases, or ion–molecule reaction schemes. By integrating a modified EI source and a cryogenically cooled single capillary column configuration, we achieved baseline separation of hydrogen from all major permanent gases and hydrocarbons in a refinery gas mixture using helium as the carrier gas. The method demonstrated excellent linearity, high sensitivity, and exceptional reproducibility. Adjustable sample-loop volumes and split ratios enabled optimization of peak shape and signal-to-noise performance for trace-level and percent-level hydrogen concentrations. Beyond hydrogen quantitation, the method provides simultaneous compositional profiling of other gases in a mixture in a single run, making it valuable for a wide range of tasks.

Lobodin, Vlad [ORNL]↗

A Rapid Sequential Separation Method for Determination of Actinides and TENORM in Fracking Wastes - 20223

With recent advances in unconventional drilling technology in the US and around the world, the risks of environmental contamination and exposure due to technologically enhanced naturally occurring radioactive materials (TENORM) from fracking wastes have also surfaced. Although the Permian Basin (southeastern New Mexico, western Texas) has long been a modest producer of oil, the advent of fracking technology a decade ago turned it into hot property for producers. A 2018 assessment of undiscovered, technically recoverable continuous oil and gas resources by the U.S. Geological Survey estimates an average 46.3 billion barrels of oil and 281 trillion cubic feet of gas. This is likely to increase the use of unconventional drilling and TENORM generation. TENORM concentrations in oil and gas exploration and production waste can be several hundred to several thousand times higher than background TENORM concentrations. Both the thorium and uranium decay chains contribute to airborne radionuclides arising from the radon gas escaping the ground and subsequently decaying as airborne particulates. Additionally, radon decay products {sup 210}Pb and {sup 210}Po can build up in scale on the internal surfaces of oil and gas handling pipes and in sludge in refineries, becoming potential inhalation and ingestion hazards for workers. Furthermore, southeastern NM is also home to world's only licensed and operating transuranic nuclear waste repository, the DoE's Waste Isolation Pilot Plant (WIPP). Plutonium isotopes ({sup 239+240}Pu) and {sup 241}Am, are expected to account for more than 99% of the total radioactivity scheduled for disposal in the WIPP repository. Thus, an improved understanding of the environmental fate and transport of TENORM, liberated by unconventional drilling, is essential to assess how best to protect individuals and the environment. In this context, accurate measurement of TENORM and actinides in environmental and biological samples is essential. In this presentation, a new sequential method for the separation and pre-concentration of actinides (Pu, Am, Np) and TENORM (Po, U and Th) derived from oil and gas exploration is proposed. The TEVA method involves a rapid co-precipitation step to remove matrix interferences from the samples, followed by plutonium oxidation state adjustment to Pu (IV) and an incubation period of ∼ 1 hour at 50-60 deg. C to allow the resultant Po (II) to oxidize into Po(IV). The polonium, neptunium, thorium and plutonium are then separated on a TEVA column, while americium and uranium are separated on a TRU column. After separation, the alpha counting source was prepared by micro-precipitation with copper sulfide (CuS) for polonium and neodymium fluoride (NdF{sub 3}) for actinides. The efficiency and reliability of the procedures were tested by analyzing filter, drinking water and frack sand samples. The method is simple, robust and can be performed quickly with excellent removal of interferences, high chemical recovery and very good alpha peak resolution. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Research on miniature gas analysis systems

Technology for fabricating very small valves, whose function will be to introduce a small sample of the gas to be analyzed into the main carrier gas stream flowing through the chromatograph column is described. In addition, some analyses were made of the factors governing the resolution of gas chromatographs, particularly those with miniature columns. These analyses show how important the column lining thickness is in governing the ability of a miniature column to separate components of an unknown gas. A brief description of column lining factors is included. Preliminary work on a super small thermistor detector is included.

Angell, J. B.↗

Radically Engineered Modular Air Separation System with Tailored Oxygen Sorbents

The commercial energy sector relies heavily on fossil fuel conversion, and in the process releases a significant amount of CO 2 . A promising technology to utilize fossil fuels with relatively affordable CO 2 capture is gasification. However, it requires a pure oxygen stream. The current state of the art method to produce oxygen is cryogenic air separation, which supercools air to a liquid, and then using distillation columns to separate the components. While this method has been thoroughly studied, it only has a 25% efficiency from a second law standpoint and therefore requires a significant amount of energy (and associated emissions) for oxygen production. This, then, lowers the incentive for carbon capture within a plant, so alternative methods need to be investigated. One potential method, chemical looping air separation (CLAS), is a promising method to replace state of the art oxygen generation technologies. CLAS utilizes a cyclic redox scheme with an oxygen sorbent to create pure oxygen streams. This approach typically utilizes a dual reactor scheme where the oxygen deficient sorbent enters the first reactor and is subjected to high oxygen partial pressures to re-oxidize the sorbent. Then the sorbent is sent to the reducing reactor, where it is subjected to low oxygen partial pressure (steam or vacuum) to releases oxygen. The overarching objective of this project was to discover the principles for rational design and optimization of oxygen sorbents and process design to ensure the process is a viable replacement for cryogenic air separation, especially in the context of modular gasification systems. This was done through development, characterization, testing, and analyses of (a) high temperature mixed composite oxides; (b) low temperature doped perovskite oxides (A1 x A2 1-x B1 y B2 1-y O 3 ); (c) scale up synthesis and testing of the optimized sorbent particles; (d) process design and analyses of the CLAS system in the context of modular gasification applications.

01 COAL, LIGNITE, AND PEAT↗

A lipidomics platform to analyze the fatty acid compositions of non-polar and polar lipid molecular species from plant tissues: Examples from developing seeds and seedlings of pennycress (Thlaspi arvense)

The lipidome comprises the total content of molecular species of each lipid class, and is measured using the analytical techniques of lipidomics. Many liquid chromatography-mass spectrometry (LC-MS) methods have previously been described to characterize the lipidome. However, many lipidomic approaches may not fully uncover the subtleties of lipid molecular species, such as the full fatty acid (FA) composition of certain lipid classes. Here, we describe a stepwise targeted lipidomics approach to characterize the polar and non-polar lipid classes using complementary LC-MS methods. Our “polar” method measures 260 molecular species across 12 polar lipid classes, and is performed using hydrophilic interaction chromatography (HILIC) on a NH2 column to separate lipid classes by their headgroup. Our “non-polar” method measures 254 molecular species across three non-polar lipid classes, separating molecular species on their FA characteristics by reverse phase (RP) chromatography on a C30 column. Five different extraction methods were compared, with an MTBE-based extraction chosen for the final lipidomics workflow. A state-of-the-art strategy to determine and relatively quantify the FA composition of triacylglycerols is also described. This lipidomics workflow was applied to developing, mature, and germinated pennycress seeds/seedlings and found unexpected changes among several lipid molecular species. During development, diacylglycerols predominantly contained long chain length FAs, which contrasted with the very long chain FAs of triacylglycerols in mature seeds. Potential metabolic explanations are discussed. The lack of very long chain fatty acids in diacylglycerols of germinating seeds may indicate very long chain FAs, such as erucic acid, are preferentially channeled into beta-oxidation for energy production.

59 BASIC BIOLOGICAL SCIENCES↗

A gas chromatographic air analyzer fabricated on a silicon wafer

A miniature gas analysis system has been built based on the principles of gas chromatography (GC). The major components are fabricated in silicon using photolithography and chemical etching techniques, which allows size reductions of nearly three orders of magnitude compared to conventional laboratory instruments. The chromatography system consists of a sample injection valve and a 1.5-m-long separating capillary column, which are fabricated on a substrate silicon wafer. The output thermal conductivity detector is separately batch fabricated and integrably mounted on the substrate wafer. The theory of gas chromatography has been used to optimize the performance of the sensor so that separations of gaseous hydrocarbon mixtures are performed in less than 10 s. The system is expected to find application in the areas of portable ambient air quality monitors, implanted biological experiments, and planetary probes.

Terry, S. C.↗

Batch and column studies of radium, actinium, thorium and protactinium on CL resin in nitric acid, hydrochloric acid and hydrofluoric acid

CL resin (TrisKem International) was characterized for separations of radium, actinium, thorium and protactinium. Batch studies are presented for radium, actinium and thorium in HCl and HNO3 as well as for radium, thorium and protactinium in HF. The uptake of thorium from dilute HNO3 (≤ 10 -4 M) and dilute HCl (≤ 10 -4 M) was found to be very high (D w > 100 in HNO 3 and > 1000 in HCl). Kinetics studies on thorium were performed in HCl and HNO 3 to determine suitably for column separations. Six column separation studies are presented including the separation of trace thorium from radium and actinium in dilute HCl and HNO 3 , the separation of radium from 1 mg 232 Th in dilute HCl, the separation of thorium and radium in the presence of HCl and excess Cl-, the separation of radium, protactinium and thorium by retention of protactinium and the separation of protactinium and thorium by retention of thorium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Are Compton-thin AGNs Globally Compton Thin?

We select eight nearby active galactic nuclei (AGNs) which, based on previous work, appear to be Compton-thin in the line of sight. We model with MYTORUS their broadband X-ray spectra from 20 individual observations with Suzaku, accounting self-consistently for Fe Kα line emission, as well as direct and scattered continuum from matter with finite column density and solar Fe abundance. Our model configuration allows us to measure the global, out of the line of sight, equivalent hydrogen column density separately from that in the line of sight. For 5 out of 20 observations (in 3 AGNs) we find that the global column density is in fact ≳1.5 × 1024 per sq.cm, consistent with the distant scattering matter being Compton-thick. For a fourth AGN, two out of five observations are also consistent with being Compton-thick, although with large errors. Some of these AGNs have been reported to host relativistically broadened Fe Kα emission. Based on our modeling, the Fe Kα emission line is not resolved in all but two Suzaku observations, and the data can be fitted well with models that only include a narrow Fe Kα emission line.

P. Tzanavaris↗

Adapting LEU-Modified Cintichem Process for Processing Up to 750 Grams of Uranium Targets

Argonne National Laboratory (Argonne) developed a low-enriched uranium (LEU)-modified Cintichem (LMC) process to enable production and purification of fission-produced molybdenum-99 (Mo-99) from LEU foil targets. This separation scheme starts with nitric acid (HNO 3 ) dissolution of irradiated LEU foil targets that yields an approximate final volume of 2 L. The dissolved uranium solution containing fission products, including Mo-99, is then treated by loading the solution on a titania-based recovery column to separate Mo-99 from bulk uranium. After several washing steps, Mo and other fission products are stripped from the titania column using sodium hydroxide (NaOH). The eluate is then acidified using nitric acid and subsequently processed for final purification using the LMC process. Uranium and most fission products are not adsorbed on the titania column but are eluted (i.e., removed using a solvent) during the wash steps; they can be purified and recycled into new uranium targets.

07 ISOTOPE AND RADIATION SOURCES↗

Health monitoring device

Example aspects of a volatile organic compound detection device, a wearable health monitoring device, and a method of monitoring a user's health are disclosed. The volatile organic compound detection device can comprise a collector comprising a collector material configured to collect volatile organic compounds given off from a user's skin; a separator comprising a gas chromatography column configured to separate mixtures of the volatile organic compounds into their constituent chemicals; and an identifier comprising a detector and a processor, the detector configured to transduce the constituent chemicals into a signal, the processor configured to process the signal to identify specific volatile organic compounds indicative of a health condition.

42 ENGINEERING↗

Evaluation of results of cell electrophoresis experiments on space shuttle STS-3 including pre-flight and post-flight laboratory experiments

The objectives of the red blood cell experiments were to provide a visual check on the electrophoretic process and especially electroosmotic flow in space as well as to provide test separations of non-degradable standard particles for comparison with the separations of the three viable cell types studied on the Apollo-Soyuz Test Project. Determination of the maximum concentrations of cells that can be separated in column electrophore was a significant goal. Two of the eight columns were available for red cell experiments, so two concentrations of human and rabbit RBC mixtures were used. The objectives of another experiment were to evaluate the reproducibility of microgravity electrophoretic separation of living kidney cells, to separate cells with highly viability despite two freeze-thaw cycles, and to optimize the physical conditions of cell separation. Owing to the uncertain heterogeneity of the starting material, the experimental design does not assess resolution in microgravity, but improved separability was sought in comparison to density-gradient electrophoresis or continuous-flow electrophoresis. Efforts were made to increase cell yield and cell viability and to assess reproducibility directly.

Todd, P. W.↗

Dissolved gases in perennially ice-covered lakes of the McMurdo Dry Valleys, Antarctica

Measurements of dissolved N2, O2, Ar, CO2, and CH4 were made in perennially ice-covered Lake Hoare. Results confirm previous reports that O2 concentrations in the upper water column exceed atmospheric equilibrium and that N2 and Ar are supersaturated throughout the water column. The mean supersaturation of N2 was found to be 2.0 (+/- 0.37) and Ar was 3.8 (+/- 1.1). The ratios of N2/Ar (20.3 +/- 13.8), and O2/Ar (22.5 +/- 4.0) at the ice-water interface are consistent with those previously measured, suggesting that bubble formation is the main process for removing gas from the lake. However, the saturations of N2 and Ar greatly exceed those previously predicted for degassing by bubble formation only at the ice-water interface. The data support the hypothesis that removal of gas by bubbles occurs in the water column to a depth of 11 m in Lake Hoare. CO2 concentration increases from near zero at the ice-water interface to 80-100 times saturation at and below the chemocline at c. 28 m. There is considerable variability in the gas concentrations throughout the water column; samples separated in depth by one metre may vary by more than 50% in gas content. It is likely that this phenomenon results from the lack of turbulent mixing in the water column. Methane (c. 2 micrograms l-1) was detected below the chemocline and immediately above the sediment/water interface at a depth of 30 m. Samples from lakes Vanda, Joyce, and Miers, also show supersaturations of O2, N2, and Ar at levels similar to levels found in Lake Hoare.

NASA Discipline Exobiology↗