Search NASA⌕ Search

SEARCH · Search NASA

Results for “communication system security”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

End-to-End Encryption for Cyber-Physical Systems Using Fully Homomorphic Encryption

Cyber-physical systems require reliable, safe, and secure control of critical infrastructure, combining computational and networking capabilities, which heighten the risk of cyber attacks. These attacks can disrupt the physical process, causing unforeseen consequences. One solution is the use of fully homomorphic encryption (FHE) to protect the control loop, allowing for secure computations and communications without compromising signal and control system privacy. The challenge with FHE, however, is its requirement for inputs to be integers. This presentation introduces a modified Learning With Errors (LWE) FHE approach that encodes control system dynamics and signals into integers. Our proposed scheme leverages a generalized LWE encoding function and modifies the Gentry-Sahai-Waters gadget decomposition tool to encrypt the control system. Using the modified LWE scheme, we formalize a fully encrypted control system, supported by simulated results.

97 MATHEMATICS AND COMPUTING↗

Encrypted Control Using Modified Learning With Errors-based Schemes

Cyber-physical systems (CPSs) require reliable, safe, and secure control of critical infrastructure, combining computational and networking capabilities, which heighten the risk of cyber attacks. These attacks can disrupt the physical process, causing unforeseen consequences. One solution is the use of fully homomorphic encryption (FHE) to protect the control loop, allowing for secure computations and communications without compromising signal and control system privacy. The challenge with FHE, however, is its requirement for inputs to be integers. This paper introduces a modified Learning With Errors (LWE) FHE approach that encodes control system dynamics and signals into integers. Our proposed scheme leverages a generalized LWE encoding function and modifies the Gentry-Sahai-Waters (GSW) gadget decomposition tool to encrypt the control system. Using the modified LWE scheme, we formalize a fully encrypted control system, supported by simulated results.

42 - ENGINEERING↗

Revealing conductivity of p-type delta layer systems for novel computing applications

This project uses a quantum simulation technique to reveal the true conducting properties of novel atomic precision advanced manufacturing materials. With Moore's law approaching the limit of scaling for the CMOS technology, it is crucial to provide the best computing power and resources to National Security missions. Atomic precision advanced manufacturing-based computing systems can become the key to the design, use, and security of modern weapon systems, critical infrastructure, and communications. We will utilize the state-of-the-art computational methodology to create a predictive simulator for p-type atomic precision advanced manufacturing systems, which may also find applications in counterfeit detection and anti-tamper.

97 MATHEMATICS AND COMPUTING↗

Overview and Commentary on Applying the Coordinated Vulnerability Disclosure Process to Photovoltaic System Devices

The rapid expansion of photovoltaic (PV) systems, particularly inverters, has introduced new cybersecurity challenges that threaten both local operations as well as the broader electrical grid’s stability. PV inverters, integrated into critical energy infrastructure are potential targets for cyber attacks due to vulnerabilities in firmware, remote access systems, and communication protocols. The Coordinated Vulnerability Disclosure (CVD) process, as defined by the Cybersecurity and Infrastructure Security Agency (CISA), provides a framework for identifying, reporting, and addressing these vulnerabilities in a transparent and collaborative manner. This report outlines the CVD process as it applies to PV systems, detailing the roles of key stakeholders, such as manufacturers, grid operators, and security researchers. The report also highlights specific challenges in managing vulnerabilities for new and legacy PV systems, which includes those introduced by insecure communications and third-party supply chain components. By adhering to the CVD process, the PV industry can mitigate cybersecurity risks, ensure regulatory compliance, and maintain consumer trust, while safeguarding the operational resilience of the energy grid. Ultimately, the effective coordination of vulnerability management is crucial for securing the future of PV systems within the critical electric grid infrastructure landscape.

14 SOLAR ENERGY↗

The Design and Evaluation of Zero Trust Architecture for Electric Vehicle Charging Infrastructure: EVs @ Scale Series on EV Charging Station Cybersecurity

Implementing a zero trust architecture can significantly bolster the security of electric vehicle (EV) charging infrastructure. EV charging infrastructure includes numerous networked interfaces, each of which can present potential vulnerabilities. When these vulnerabilities are exploited, they can compromise the entire system, leading to severe operational and security risks. Zero trust is a security model that operates on the principle of "never trust, always verify," which helps manage the attack surface and limit the scope of any potential compromises. Fundamentally, this model ensures that no entity, whether inside or outside the network, is trusted by default. The design principles of zero trust include continuous verification, strict deny-by-default access controls, and micro-segmentation. Continuous verification ensures that every request is thoroughly checked, regardless of its origin. Strict access controls enforce the principle of least privilege, allowing users and devices only the minimum necessary access to perform their functions. Micro-segmentation involves dividing the network into smaller, isolated segments to prevent lateral movement in case of a breach. In the context of EV charging infrastructure, zero trust can be implemented through various strategies. For example, multi-factor authentication (MFA) can be required for engineers to access the management interfaces and control systems of charging stations. Real-time monitoring and analysis of network traffic can help detect and respond to anomalies. Systems that do not need to communicate with each other can be micro-segmented to enhance security. All communications should adhere to predefined policies to be permitted. Additionally, encrypting communications can protect sensitive information exchanged between chargers and management systems. This paper presents a zero trust architecture specifically designed for EV charging infrastructure. Implementing zero trust not only mitigates risks but also builds a resilient infrastructure capable of withstanding and quickly recovering from cyber threats. The architecture addresses six defined security objectives. A comprehensive test plan is developed to assess the architecture against these objectives, and the results of the evaluation are reported. This approach is essential for maintaining the reliability and integrity of EV charging services in an increasingly interconnected and vulnerable digital landscape. This is the first in a planned series of papers exploring the implementation of zero trust in EV charging infrastructure. Each paper will delve into different aspects and applications of zero trust, highlighting how various work processes and requirements can lead to distinct architectural designs. These architectures will be tailored to address specific security challenges and operational needs within the EV charging ecosystem, ensuring a robust and adaptable security framework.

33 ADVANCED PROPULSION SYSTEMS↗

CPES-QSM: A Quantitative Method Towards the Secure Operation of Cyber-Physical Energy Systems

Power systems are evolving into cyber-physical energy systems (CPES) mainly due to the integration of modern communication and Internet-of-Things (IoT) devices. CPES security evaluation is challenging since the physical and cyber layers are often not considered holistically. Existing literature focuses on only optimizing the operation of either the physical or cyber layer while ignoring the interactions between them. This paper proposes a metric, the Cyber-Physical Energy System Quantitative Security Metric (CPES-QSM), that quantifies the interaction between the cyber and physical layers across three domains: electrical, cyber-risk, and network topology. A method for incorporating the proposed cyber-metric into operational decisions is also proposed by formulating a cyber-constrained AC optimal power flow (C-ACOPF) that considers the status of all the CPES layers. The C-ACOPF considers the vulnerabilities of physical and cyber networks by incorporating factors such as voltage stability, contingencies, graph-theory, and IoT cyber risks, while using a multi-criteria decision-making technique. We note that simulation studies are conducted using standard IEEE test systems to evaluate the effectiveness of the proposed metric and the C-ACOPF formulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber and Physical Security Analysis of GSI and Noventum Application for IoT Communications

We present our findings of the red team exercise conducted on the device and application developed by Guardian Sensors, Inc. (GSI) and Noventum. The app is used for situational awareness and control of photovoltaics (PV) and microgrid energy systems. The assessments performed are practical case scenarios that assess the risks and vulnerabilities posed by the app through targeted activities that could be engaged by an adversary. The assessment team’s results and recommendations are provided to inform on and mitigate the identified weaknesses to improve secure user authentication, connections, and communications. The recommendations in this report are not intended to be a security panacea but will add the desired defense-in-depth layer to securing communication of such interconnected systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synergies Between Nuclear Security and Critical Infrastructure: National Legal and Regulatory Frameworks

Nuclear reactors and other nuclear facilities are part of a nation's critical infrastructure assets. Key cross-sector interdependencies, in relation to energy, transportation systems, communications, emergency services, water, information technologies and others, result in inevitable synergies between legal frameworks for the security of nuclear facilities and legal frameworks for the protection of critical infrastructure. The protection of nuclear facilities against sabotage and other malicious acts is paramount in ensuring energy security and thus ensuring uninterrupted energy supply. The protection of other sectors, such as uninterrupted communications, secure water supply, and others, supports a safe and secure operation of nuclear facilities. Some countries rely on broader critical infrastructure frameworks to impose security requirements on nuclear facilities, or to achieve robust cybersecurity systems. This paper will analyze the interdependencies and synergies between the legal and regulatory frameworks for critical infrastructure protection and nuclear facilities' security by comparing various national frameworks. The paper will also propose modalities to leverage the best practices and requirements from each framework towards energy security goals and stronger national nuclear security regimes.

Man, Madalina-Anca↗

An Experimental Setup for Mechanical Vibration Analysis Using VLC

This study explores the potential applications across various domains, including earthquake detection and warning systems, where the system’s sensitivity to ground vibrations can contribute to early seismic event detection. Additionally, the study paves the way of developing applications of VLC/T in mechanical vibration and stability analysis of engines and platforms, offering insights into structural integrity and performance optimization. These multifaceted applications underscore the adaptability and potential of VLC/T systems in diverse fields, heralding advancements in sensing, communication, and security technologies. To achieve this, in this study, Peak to Average Power Ratio (PAPR) is proposed to represent the impact of mechanical shocks and vibrations generated by several weights dropped onto the platform with which the receiver is fixed. Even though non-contact measurement methodology is preferred for various reasons, the proposed measurement campaign obtains the data in contact form; however, the system and signal model proposed in this study could easily be extended into non-contact form. Considering the fact that the proposed measurement campaign employs off-the-shelf products, it is cost-effective and very scalable.

Yilmaz, Ahmet Mucahit↗

Cross-Layered Cyber-Physical Power System State Estimation towards a Secure Grid Operation

In the Smart Grid paradigm, this critical infrastructure operation is increasingly exposed to cyber-threats due to the increased dependency on communication networks. An adversary can launch an attack on a power grid operation through False Data Injection into system measurements and/or through attacks on the communication network, such as flooding the communication channels with unnecessary data or intercepting messages. A cross-layered strategy that combines power grid data, communication grid monitoring and Machine Learning based processing is a promising solution for detecting cyberthreats. In this paper, an implementation of an integrated solution of a cross-layer framework is presented. The advantage of such a framework is the augmentation of valuable data that enhances the detection of anomalies in the operation of power grid. IEEE 118-bus system is built in Simulink to provide a power grid testing environment and communication network data is emulated using SimComponents. The performance of the framework is investigated under various FDI and communication attacks.

cyber security, network security, cyber-physical s↗

SOLAr Critical Infrastructure Energization (SOLACE): Leveraging Distributed Energy Resources to Provide Local Power

This document is a technical report based on a large-scale DOE-funded project conducted between 2019 and 2022. The project, called SOLAr Critical infrastructure Energization (SOLACE), is aimed at leveraging distributed energy resources (DERs) to provide local power to communities, feeders, or other regions. The project included a particular focus on high-value critical loads such as municipal water supply, telecommunication hubs, and disaster shelters. The key developments of the project were: (1) A comprehensive pre-event power system analysis methodology that identifies and characterizes the viable local power options. (2) A DMS-based example control system for activating and operating the local power solution during a time of crisis. (3) Grid-forming inverter technology to enable isolated local power operation and black-starting. (4) Cyber-security considerations for isolated systems when wider-area communication may be offline. This report describes the overall process that identifies and assesses the viable DER-based local power solutions for a given facility, region, or community. The report documents the process, including the key analysis steps, tools required, data requirements, and recommended pass/fail criteria for each step. It also provides a sample implementation of this process through a test case. Finally, it provides details of how a viable pre-event plan can be selected and activated at go-time when an event has occurred.

14 SOLAR ENERGY↗

Methods and systems for detection of man-in-the-middle attacks for SCADA communication networks and applications of same

A system for detecting MITM for SCADA communication networks includes secure substation-substation communication links for providing secure and reliable paths to exchange OT data between substations for OT data consistency check; a SIB in each substation for sampling CT and PT measurements to calculate voltage magnitude and phase angle thereof; a S&C server in each substation coupled to the SIB for receiving the voltage magnitude and phase angle from the SIB and obtaining a packet carrying active power flow in transmission lines between two substations and a time stamp; an IDS server placed in a SCADA center for collecting the packet of each substation sent by the S&C server; analyzing the received packet from every adjacent substation; inspecting the payload of the received packet; and triggering an intrusion alarm to a SCADA operator when the power flow is not the same as the payload of the packets.

McCann, Roy A.↗

Module-OT: A Turnkey Solution for Securing Energy Systems

The Modular Security Apparatus for Managing Distributed Cryptography for Command-and-Control Messages on Operational Technology Networks (Module-OT) is a flexible and lightweight solution for grid-edge devices focusing on end-to-end security. It is a bump- in- the-wire solution acting as a secure conduit for data between devices or systems across a network. It improves the cybersecurity posture of DER systems by providing authentication, authorization, and data integrity to secure DER communications. Additionally, it performs key management, provides data security through whitelisting Internet Protocol addresses and ports, blocks unauthorized connections, controls user access, and allows serial or Ethernet connections for added flexibility. The core software is portable to various Linux-based operating systems and is developed to be customized by the developer and researcher communities. Module-OT has been validated in the lab, has been demonstrated at a 500-KW PV-plus-storage site, and has been proven ready to secure operational technology devices. Its core functionality meets current standards, including validation procedures of the NIST Cryptographic Algorithm Validation Program (CAVP) and the Federal Information Processing Standard (FIPS 140-2). Because of its capability to provide an accessible and affordable option for stepping up security across modern energy systems, Module-OT can serve as an effective technological option to standardize cybersecurity moving forward.

cryptography↗

Investigate the Security of Electric Vehicle (EV) Ecosystem Applications

Apps that run on mobile devices are one of critical components of the electric vehicle (EV) ecosystem and pose possible threat actor points of entry that may impact the trust and security of EV charging systems in the future. Mobile apps often rely on communication between cloud servers and users, thereby creating potential points of entry for cyberattacks. Although app stores such as Apple App Store or Google Play Store generally test the security of apps, the cyber aspects may not be sufficient for many entities including DOD, federal fleets, and commercial entities. A more thorough inspection and the ability to influence developers is imminently needed. This research studies security attributes and vulnerabilities of a sample of mobile applications that support key user functions in the EV ecosystem. The study shows that all analyzed apps have security risks, categorized as either high or medium or both and a comprehensive cybersecurity guideline for developing mobile apps is necessary.

33 ADVANCED PROPULSION SYSTEMS↗

Best Practices for Grid Communications

As the grid evolves, the communications architecture will need to evolve with it. That architecture affords a structured means by which the evolving complexities of the modern electric grid can be managed. This document provides best practices that can be implemented in the grid of today and evolve towards the grid and grid architecture of the future. The evolving grid and its control communications increasingly rely on commercial communications providers and a variety of technologies, from wireless (e.g., 5G, microwave, Wi-Fi) to wireline (fiber, copper) to radio communications (P25, other repeater-based systems), and all these communications systems rely on electric power. A reliable and resilient grid must account for this complex set of interdependencies in its planning activities, especially those involving restoration and recovery. The participation of all relevant parties in both planning and exercising of plans can prevent unexpected conditions that impede the reliable operation and recovery of the grid. Best practices for grid communications include using a Network Management System to document the operational state, define and monitor baselines, detect changes, and accelerate response to abnormalities. If transitioning from SONET to IP/packet-based systems, translating grid requirements into communications requirements for latency, bandwidth and throughput, IP packet delay variation, packet loss, and availability should inform and drive technology planning and selection as well as that communication system’s Quality of Service (QoS) policies and Service Level Agreements (SLAs). Secure and reliable timing is another key component of a reliable and resilient grid that can operate through adverse events. A trusted internal NTP configuration, an integrated and diverse timing delivery system, optimizing the timing architecture based on the transport technologies of the communications system, and using established standards can deliver the level of timing accuracy required by a range of time-sensitive power system applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Field Programmable Gate Array-Based Reactor Protection Systems and Potential for Inclusion of Secure Elements to Improve Cybersecurity

For acceptable implementations of technologies like wireless communications, remote monitoring, etc., strong mitigations must be developed and evaluated to ensure that new attack pathways do not increase risk for Advanced Reactors. Secure Elements can be adopted and adapted for this purpose based on tamper resistance and cryptographic abilities, but research must be done to properly integrate into critical components such as FPGA-based Important to Safety systems in conjunction with current and future regulations on cyber security features in Advanced Reactors. Typically, the integration of a Secure Element happens during the POST and UEFI boot of a computing platform, performed by the Operating System, which is not possible with FPGAs because they do not include these firmware components. Work must be done to identify a reliable and secure method for integration in FPGA-based systems which lack Operating Systems and therefore complex boot procedures, system calls, etc.

97 MATHEMATICS AND COMPUTING↗

Field Programmable Gate Array-Based Reactor Protection Systems and Potential for Inclusion of Secure Elements to Improve Cybersecurity

For acceptable implementations of technologies like wireless communications, remote monitoring, etc., strong mitigations must be developed and evaluated to ensure that new attack pathways do not increase risk for Advanced Reactors. Secure Elements can be adopted and adapted for this purpose based on tamper resistance and cryptographic abilities, but research must be done to properly integrate into critical components such as FPGA-based Important to Safety systems in conjunction with current and future regulations on cyber security features in Advanced Reactors. Typically, the integration of a Secure Element happens during the POST and UEFI boot of a computing platform, performed by the Operating System, which is not possible with FPGAs because they do not include these firmware components. Work must be done to identify a reliable and secure method for integration in FPGA-based systems which lack Operating Systems and therefore complex boot procedures, system calls, etc.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An intelligent energy router for managing behind-the-meter resources and assets

With increase in distributed energy resources (DERs) and smart loads, each energy resource and load need a separate power conversion system leading to complex coordination and interaction, reduced energy conversion efficiency, coordinating compliance to grid standards (IEEE 1547) from multiple sources, reduced security. Also, multiple vendors with legacy system designs and proprietary communications interfaces result in redundancy and increase in cost of power electronics systems. This paper presents an energy router concept for buildings applications which provides autonomous power flow between sources and loads with a novel agent-based software interface.

Chinthavali, Madhu Sudhan↗