Search NASA⌕ Search

SEARCH · Search NASA

Results for “condor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

62 records · Page 4

Highly-detailed neutronic and thermal-hydraulic coupled calculations for OPAL reactor using diverse codes and approaches

The industry-standard approach for designing and operating research reactors cores relies on well-established methodologies that consider uncoupled neutronic calculations and a subchannel analysis of the Thermal-Hydraulic (TH) associated problem. Advancements in computing power and codes allow detailed Multiphysics approaches to be implemented, thereby reducing conservatism. In this study, a comparative analysis of results from diverse detailed neutronic-TH coupled core approaches is developed. To address a realistic application case, the comparison is made for a reported critical configuration from the Open Pool Australian Lightwater research reactor (OPAL) at Hot Full Power (HFP) and low burnup. Both cell-core and stochastic methodologies for neutronics are evaluated, whereas two different subchannel codes are considered for TH. In conclusion, the convergence of the coupled schemes, and the consistency of the main parameters are discussed, showing the compatibility of the alternative methods and their ability to offer critical insights not captured by standard practices.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An Accurate Fast Fluid Dynamics Model for Data Center Applications

Traditional CFD is broadly useful in the design and operation of reliable and efficient data centers. It is nevertheless computationally expensive, particularly when employed for design optimization, which usually requires multiple simulations. To speed-up calculations while retaining essential airflow physics, several researchers have turned to an alternative CFD methodology, namely, fast fluid dynamics (FFD). FFD has been reported to be much faster than traditional CFD, but at an assumed (acceptable) trade-off of reduced accuracy. However, a recent comparison of FFD and traditional CFD for data center plenum applications produced nearly indistinguishable results and suggested that previously-reported FFD/traditional-CFD differences were due primarily to inconsistent: 1) advection schemes, 2) computational grids, and 3) turbulence models. The present paper extends this FFD/traditional-CFD comparison to the data center whitespace and confirms the finding that a true like-for-like comparison produces nearly identical predictions. Our FFD implementation utilizes a first-order upwind finite-volume scheme for advection like traditional CFD, so alternative advection schemes (e.g., semi-Lagrangian) are not considered further here. Likewise, the effect of grid choice on traditional-CFD predictions is well known. However, the effect of turbulence model for data center applications has not been reported extensively so we do consider this topic further here. We compare the standard k-e and a simpler algebraic model to benchmark experimental data from a real data center. We find that the algebraic turbulence model predicts rack-inlet temperatures at a similar level-of-accuracy as the k-e model for our fairly-simple-airflow reference data center.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving Data Center Energy Efficiency Through End-to-End Cooling Modeling and Optimization. Final Report

This report summarizes the development and demonstration of the three features developed for the DOE project “Improving Data Center Energy Efficiency through End-to-End Cooling Modeling and Optimization” (Award No. DE-EE0007688). The development of the three software features, Feature 1: Optimization of Cooling System Operation, Feature 2: Optimization of Airflow Management System, and Feature 3: Simultaneous Optimization of Airflow Management and Cooling Systems, are described first. Feature 1 is implemented in Phase 1 of the project and demonstrates 15% energy savings from cooling system optimization by applying the proposed retrofit solutions. Feature 2 is implemented in Phase 2 and the assessments show cooling energy-saving potential between 19.3% and 54.0%, depending on the energy-saving measures employed. In addition, investigating the energy saving potential for a hypothetical simple data center shows about 6.8% energy savings by optimizing the server load placement. Feature 3 is implemented in Phase 3 and the results show energy savings of 53.4% and 74.6% for the two partner data centers, respectively, compared to the baselines defined in Phase 1. Lastly, the project outcomes including software releases and publications are discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance of multilayer coated diffraction gratings in the EUV

The effect of multilayer coating application on the performance of a diffraction grating in the EUV spectral region was evaluated by examining the performance of a 3600-line/mm and a 1200-line/mm replica blazed gratings, designed for operation in the 300-A spectral region in first order. A ten-layer IrSi multilayer optimized for 304 A was deposited using electron-beam evaporation. The grating efficiency was measured on the SURF II calibration beamline in a chamber designed for calibrating the solar EUV rocket telescope and spectrograph multilayer coatings. A significant (by a factor of about 7) enhancement in grating efficiency in the 300-A region was demonstrated.

Keski-Kuha, Ritva A. M.↗

Extreme ultraviolet performance of a multilayer coated high density toroidal grating

The performance of a multilayer coated diffraction grating has been evaluated at EUV wavelengths both in terms of absolute efficiency and spectral resolution. The application of ten-layer Ir/Si multilayer coating to a 3600-lines/mm blazed toroidal replica grating produced a factor of 9 enhancement in peak efficiency near the design wavelength of about 30 nm in first order, without degrading its excellent quasistigmatic spectral resolution. The measured EUV efficiency peaked at 3.3 percent and was improved over the full spectral range between 25 and 35 nm compared with the premultilayer replica which had a standard gold coating. In addition, the grating's spectral resolution of greater than 5000 was maintained.

Thomas, Roger J.↗

The SERTS-97 Rocket Experiment on Study Activity on the Sun: Flight 36.167-GS on 1997 November 18

This paper describes mainly the 1997 version of the Solar EUV Rocket Telescope and Spectrograph (SERTS-97), a scientific experiment that operated on NASA's suborbital rocket flight 36.167-GS. Its function was to study activity on the Sun and to provide a cross calibration for the CDS instrument on the SOHO satellite. The experiment was designed, built, and tested by the Solar Physics Branch of the Laboratory for Astronomy and Solar Physics at the Goddard Space Flight Center (GSFC). Other essential sections of the rocket were built under the management of the Sounding Rockets Program Office. These sections include the electronics, timers, IGN despin, the SPARCS pointing controls, the S-19 flight course correction section, the rocket motors, the telemetry, ORSA, and OGIVE.

Swartz, Marvin↗

A Reflective Framework for Performance Management (REFORM) of Real-Time Hybrid Simulation

Currently, the lack of (1) a sufficiently integrated, adaptive, and reflective framework to ensure the safety, integrity, and coordinated evolution of a real-time hybrid simulation (RTHS) as it runs, and (2) the ability to articulate and gauge suitable measures of the performance and integrity of an experiment, both as it runs and post-hoc, have prevented researchers from tackling a wide range of complex research problems of vital national interest. To address these limitations of the current state-of-the-art, we propose a framework named Reflective Framework for Performance Management (REFORM) of real-time hybrid simulation. REFORM will support the execution of more complex RTHS experiments than can be conducted today, and will allow them to be configured rapidly, performed safely, and analyzed thoroughly. This study provides a description of the building blocks associated with the first phase of this development (REFORM-I). REFORM-I is verified and demonstrated through application to an expanded version of the benchmark control problem for real-time hybrid simulation.

Amin Maghareh↗

A New Fast Fluid Dynamics Model for Data-Center Floor Plenums

A raised-floor plenum is often used to distribute cooling airflow in data centers. Traditional Computational Fluid Dynamics (CFD) can accurately model airflow distribution in plenums, but it is expensive (computationally and financially) and is, therefore, often not accessible to the data center designer or operator. This paper presents an alternative CFD methodology based on Fast Fluid Dynamics (FFD), which is faster, more parallelizable, and simpler to program. The improvement in computational speed afforded by FFD is particularly important for multiple-iteration optimization, transient simulations, or applications for which near-real-time performance is required. Here, the potential speed improvements of FFD have been widely documented; however, it has been generally accepted that this benefit is accompanied by a modest loss of accuracy relative to traditional CFD. We show here that this is not necessarily true. Plenum airflow predictions by our FFD implementation, which utilizes a first-order upwind rather than Semi-Lagrangian advection scheme of previous research, are extremely close to those predicted by traditional CFD - provided the same turbulence model and computational grid are used consistently.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗