Search NASA⌕ Search

SEARCH · Search NASA

Results for “container materials valves”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

57 records · Page 4

Nearly Seamless Vacuum-Insulated Boxes

A design concept, and a fabrication process that would implement the design concept, have been proposed for nearly seamless vacuum-insulated boxes that could be the main structural components of a variety of controlled-temperature containers, including common household refrigerators and insulating containers for shipping foods. In a typical case, a vacuum-insulated box would be shaped like a rectangular parallelepiped conventional refrigerator box having five fully closed sides and a hinged door on the sixth side. Although it is possible to construct the five-closed-side portion of the box as an assembly of five unitary vacuum-insulated panels, it is not desirable to do so because the relatively high thermal conductances of the seams between the panels would contribute significant amounts of heat leakage, relative to the leakage through the panels themselves. In contrast, the proposal would make it possible to reduce heat leakage by constructing the five-closed-side portion of the box plus the stationary portion (if any) of the sixth side as a single, seamless unit; the only remaining seam would be the edge seal around the door. The basic cross-sectional configuration of each side of a vacuum-insulated box according to the proposal would be that of a conventional vacuum-insulated panel: a low-density, porous core material filling a partially evacuated space between face sheets. However, neither the face sheets nor the core would be conventional. The face sheets would be opposite sides of a vacuum bag. The core material would be a flexible polymer-modified silica aerogel of the type described in Silica/Polymer and Silica/Polymer/Fiber Composite Aero - gels (MSC-23736) in this issue of NASA Tech Briefs. As noted in that article, the stiffness of this core material against compression is greater than that of prior aerogels. This is an important advantage because it translates to greater retention of thickness and, hence, of insulation performance when pressure is applied across the thickness, in particular, when the space between the face sheets is evacuated, causing the core material to be squeezed between the face sheets by atmospheric pressure. Fabrication of a typical vacuum-insulated box according to the proposal would begin with fabrication of a cross-shaped polymer-modified aerogel blanket. The dimensions of the cross would be chosen so that (1) the central rectangular portion of the cross would form the core for the back of the box and (2) the arms of the cross could be folded 90 from the back plane to form the cores of the adjacent four sides of the box. Optionally, the blanket could include tabs for joining the folded sides of the blanket along mating edges and tabs that could serve as hinges for the door. Vacuum bags in the form of similar five-sided boxes would be made of a suitable polymeric film, one bag to fit the outer core surface, the other to fit the inner core surface. By use of commercially available film-sealing equipment, these box-shaped bags would be seamed together to form a single vacuum bag encasing the box-shaped core. Also, a one-way valve would be sealed to the bag. Through this valve, the interior of the bag would be evacuated to a pressure between 1 and 10 torr (approximately between 0.13 and 1.3 kPa). The polymer-modified aerogel core material is known to perform well as a thermal insulator in such a partial vacuum.

Stepanian, Christopher J.↗

RELAP5-3D Modeling of High Temperature Test Facility (HTTF) Test PG-26

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors with prismatic fuel and reflector blocks. Several tests have been completed, and more are still planned to at the HTTF, including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This report analyses test PG-26, a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC. PG-26 has been performed at the HTTF between May 30 and June 30, 2019. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heaters. The DCC transient was initiated during the 50 th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test. Version 4.4.2ie of the RELAP5-3D computer code has been used to model the HTTF PG-26 test, and results have been compared to available high-quality measured data. The model used in this study is the quality-controlled HTTF RELAP5-3D model (HTTF base 2018-04-19 QA), originally developed by P. Bayless. The report includes RELAP5-3D results of the “base calculations” as well as some sensitivities to important uncertain model inputs, such as primary helium mass flow rate, core ceramic thermal properties, as well as heat evacuation and loop friction models. Using the base RELAP5-3D model predicts a countercurrent helium flow in the hot duct observed at the beginning of the DCC, but instead of going into a molecular diffusion mode, the model predicts the onset of natural convection. Increasing friction in the core and hot duct prevents the natural convection from happening in some of the simulations. Although some temperatures are well predicted (and even overpredicted), the general tendency is to underpredict the ceramic and helium temperatures and heat removal rates during the DCC, resulting in many of the assessment findings being in minimal or insufficient agreement with the data. It is worth noting that the described discrepancies between measured data and RELAP5-3D predictions are not RELAP5-3D code limitations. More so, they reflect limitations in boundary condition and thermal property knowledge. While the RELAP5-3D calculations of the test provide some insights into what happens during the transient, and point to missing or potentially uncertain data to which the experimenters can direct their attention, the principal conclusion is that the PG-26 test data are insufficient for a system code assessment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications, including high strength-to-weight ratio, and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods. This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel during cure. In order to perform ultrasonic scans in-situ during cure, the system needed to be able to operate at oven temperatures up to 200 °C. There are no commercially available ultrasonic scanning systems that can operate continuously at these temperatures, so an enclosure was fabricated to insulate the ultrasonic system in the curing oven. The enclosure housed a MISTRAS® motorized X-Y raster scanner and contact transducer (Olympus® X2002). The Olympus® X2002 contact transducer is a continuous high-temperature delay line transducer with a center frequency of 2.25 MHz. In order to prevent the inside of the enclosure from reaching high temperatures, a sparge pipe inside the cooling enclosure was connected to a liquid nitrogen (LN2) tank outside of the oven via insulated hoses. The cooling system was automatically controlled by a temperature controller that was programmed to open a solenoid valve along the hose at 31 ℃ and close at 28 ℃ inside the cooling enclosure. When the solenoid valve was open, LN2 would flow from the LN2 tank and vaporize prior to reaching cooling enclosure. A U-shaped sparge pipe had holes drilled along its length to uniformly introduce cold nitrogen gas into the cooling enclosure. This prevented the motors from ever reaching the maximum desired operating temperature of 38 ℃. In the bottom of the enclosure, the tool plate was placed with the composite facing the outside of the enclosure, exposing it to the temperatures of the oven. The tool plate was 63.5 mm thick borosilicate glass, which was chosen for its low ultrasonic attenuation and moderate thermal conductivity. A thin layer of ultrasonic couplant was placed on the tool plate. The transducer sent and received ultrasonic waves through the tool plate into the composite. A MISTRAS® Remote UT System performed all wave generation, analog to digital conversion, and data acquisition and processing. The transducer was connected directly to the Remote UT System via a high-temperature BNC cable (CD International, RG-316). Polyimide insulated copper wire was used to connect the scanner to a 2-axis motor drive, which was connected to the Remote UT System. The motor drive and Remote UT System were located outside the industrial oven. A diagram of the ultrasonic system is shown in Figure 1. Figure 1: Diagram of ultrasonic in-situ defect detection system. In this study, a porosity gradient was introduced into the carbon fiber reinforced polymer (CFRP) composite through a misfit of the part and caul plate. A 24-ply quasi-isotropic ([0/90, ±45]12S) composite panel was laid up using Newport® AS4C-M/NB321 out-of-autoclave (OOA) plain weave (PW) prepreg (42% resin content, 195 g/m2). The first 16 plies were 203 mm × 203 mm. Ply drops were incorporated into the panel by decreasing the length of plies 17-24. The sizes of each ply are included in Table 1. All plies were centered along their length (x-axis) creating a trapezoidal type cross-section. Table 1: Ply sizes Plies Length (mm) Width (mm) 1-16 203 203 17-18 102 203 19-20 85 203 21-22 68 203 23-24 51 203 A 15-5 stainless steel caul plate (Size: 203 × 203 × 1.2 mm) was placed on the laminate. The composite and caul plate were vacuum bagged to the tool plate. Per the product datasheet, Newport 321 can be cured between 121 °C and 149 °C, depending on service temperature, with a hold for 90-120 minutes. Based on prior thermal testing of the cooling enclosure, the desired composite temperature cycle could be attained when the air temperature of the oven was ramped to 160 °C at a rate of 1.7 °C/min with a 3 hour hold. The extended hold was not necessary to cure the composite, but did allow for additional scans at the cure temperature during preliminary testing. The composite panel was under vacuum pressure for the entire cure cycle. Under vacuum, the caul plate deformed causing high and low pressure regions. The low-pressure regions formed high porosity in the composite part. The ultrasonic data collected showed that the inspection system was able to monitor the evolution of porosity within the composite throughout the cure cycle. Fifty scans of a 203 mm × 51 mm (8 in. × 2 in.) area of the composite were completed throughout the cure cycle. The scan speed was set to 43 mm/s in the x-direction and 36 mm/s in the y-direction, with a 1.0 mm/pixel resolution in both directions. Each scan took approximately five minutes to complete. Figure 2 shows C-scan amplitude data (top view) from one scan during the cure cycle. The color map indicates the maximum amplitude (%) measured with a time gate that contains reflections from the back surface (furthest from the transducer in contact with the caul plate) of the composite. Because porosity in the composite increases the ultrasonic attenuation in the composite part, a higher amplitude (red) indicates low porosity and a lower amplitude (blue) indicates high porosity. The regions where the caul plate was applying increased pressure (center and ends of the panel) resulted in reduced porosity, whereas the ply drop regions had reduced pressure and thus had higher porosity. Figure 2: Amplitude C-scan (top view) of OOA composite from one scan during the 160 °C temperature hold. Higher amplitude (red) indicates low porosity. Lower amplitude (blue) indicates high porosity. A B-scan is a two-dimensional image plotting the ultrasonic signals from a single y-position at every x-location of the composite panel. The travel time (μs) of the ultrasonic wave (representing the through-thickness location) is plotted along the y-axis, and the ultrasonic wave signal is represented as a contour map. Based on the B-scan data, the location of the defects with respect to the composite thickness was able to be determined. The ply drop regions had high porosity near the front (tool plate) surface of the composite (Figure 3). Figure 3: B-scan (cross-section view) of OOA composite from one scan during the 160 °C temperature hold. Using the data obtained from amplitude C-scans and B-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized with high spatial resolution. This paper will discuss the evolution of porosity content in the OOA composite during cure. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

Tyler B. Hudson↗