Search NASA⌕ Search

SEARCH · Search NASA

Results for “contrast enhancement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Shape-Controlled Synthesis of Copper Nanocrystals for Plasmonic, Biomedical, and Electrocatalytic Applications

As a metal that can occur in nature in the elemental form, copper (Cu) has been used by humans since ca. 8000 BC. With most properties matching those of Ag and Au, Cu has played a more significant role in commercial applications owing to its much higher (the 25th among all elements) abundance in Earth’s crust and thus more affordable price. In addition to its common use as a conductor of heat and electricity, it is a constituent of various metal alloys for hardware, coins, strain gauges, and thermocouples. Bulk Cu is also widely utilized as a building material. When downsized to the nanoscale, Cu and Cu-based structures have found widespread use in applications ranging from electronics to optoelectronics, plasmonics, catalysis, sensing, and biomedicine. Besides Ag and Au, for example, Cu is another metal known for its localized surface plasmon resonance (LSPR) in the visible and near-infrared regions when prepared as nanocrystals. As a potential replacement for indium–tin oxide (ITO) films, polymer coatings containing Cu nanowires are strong candidates for the fabrication of transparent and flexible electrodes key to touchscreen display and related applications. The commercial catalysts for water–gas shift and gas detoxification reactions are also based on Cu nanoparticles. Most recently, Cu nanocrystals have attracted considerable interest for their superior selectivity toward hydrocarbons and multicarbon species during the electrochemical reduction of CO 2 . The success of all these applications critically depends on our ability to control the shape and surface structure of the nanocrystals. Relative to Ag and Au, it is more challenging to generate Cu-based nanocrystals using colloidal methods due to its lower reduction potential and greater vulnerability to oxidation. Here, in this account, we discuss recent progress in the colloidal synthesis of Cu nanocrystals with controlled shapes for plasmonic, biomedical, and catalytic applications. With glucose serving as a reducing agent, Cu nanocrystals bearing a twinned or single-crystal structure can be synthesized using an aqueous system with the assistance of hexadecylamine (HDA). In this synthetic protocol, HDA not only passivates the surface to protect the nanocrystals from oxidation but also manipulates the reduction kinetics of Cu(II) precursor through coordination and an increase of solution pH. Typical products include nanocubes and penta-twinned nanowires whose surfaces are dominated by {100} facets. When seeds produced either in situ or ex situ are introduced, Cu-based nanocrystals featuring a singly twinned, core–shell, or Janus structure can be readily synthesized. Aside from segmented structures, Cu-based alloys with various noble metals can be synthesized through coreduction or a galvanic replacement reaction with preformed Cu nanocrystals. By controlling the size and/or shape of Cu nanocrystals, their LSPR peaks can be tuned into the near-infrared region, making them promising candidates for optical imaging contrast enhancement and photothermal treatment. The inclusion of the 64 Cu isotope makes them immediately useful in positron emission tomography and thus image-guided therapy. The surface structure, elemental distribution, and valence state of Cu-based nanocrystals can all be tailored to augment their electrocatalytic performance. It is hoped that this Account will inspire more studies into the development of rational methods capable of producing Cu-based nanocrystals with diverse and well-controlled shapes, internal structures, and compositions for a broader range of applications.

36 MATERIALS SCIENCE↗

Tetris-inspired detector with neural network for radiation mapping

Abstract Radiation mapping has attracted widespread research attention and increased public concerns on environmental monitoring. Regarding materials and their configurations, radiation detectors have been developed to identify the position and strength of the radioactive sources. However, due to the complex mechanisms of radiation-matter interaction and data limitation, high-performance and low-cost radiation mapping is still challenging. Here, we present a radiation mapping framework using Tetris-inspired detector pixels. Applying inter-pixel padding for enhancing contrast between pixels and neural networks trained with Monte Carlo (MC) simulation data, a detector with as few as four pixels can achieve high-resolution directional prediction. A moving detector with Maximum a Posteriori (MAP) further achieved radiation position localization. Field testing with a simple detector has verified the capability of the MAP method for source localization. Our framework offers an avenue for high-quality radiation mapping with simple detector configurations and is anticipated to be deployed for real-world radiation detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine learning pipeline for denoising low signal-to-noise ratio and out-of-distribution transmission electron microscopy datasets

High-resolution transmission electron microscopy (HRTEM) is crucial for observing material’s structural and morphological evolution at Angstrom scales, but the electron beam can alter these processes. Devices such as CMOS-based direct-electron detectors operating in electron-counting mode can be utilized to substantially reduce the electron dosage. However, the resulting images often lead to a low signal-to-noise ratio, which requires frame integration that sacrifices temporal resolution. Several machine learning (ML) models have been recently developed to successfully denoise HRTEM images. Yet, these models are often computationally expensive, and their inference speeds on GPUs are outpaced by the imaging speed of advanced detectors, precluding in situ analysis. Furthermore, the performance of these denoising models on datasets with imaging conditions that deviate from the training datasets has not been evaluated. To mitigate these gaps, we propose a new self-supervised ML denoising pipeline specifically designed for time-series HRTEM images. This pipeline integrates a blind-spot convolution neural network with pre-processing and post-processing steps, including drift correction and low-pass filtering. Results demonstrate that our model outperforms various other ML and non-ML denoising methods in noise reduction and contrast enhancement, leading to improved visual clarity of atomic features. Additionally, the model is drastically faster than U-Net-based ML models and demonstrates excellent out-of-distribution generalization. The model’s computational inference speed is in the order of milliseconds per image, rendering it suitable for application in in-situ HRTEM experiments.

36 MATERIALS SCIENCE↗

Label-free X-ray estimation of brain amyloid burden

Amyloid plaque deposits in the brain are indicative of Alzheimer’s and other diseases. Measurements of brain amyloid burden in small animals require laborious post-mortem histological analysis or resource-intensive, contrast-enhanced imaging techniques. We describe a label-free method based on spectral small-angle X-ray scattering with a polychromatic beam for in vivo estimation of brain amyloid burden. Our findings comparing 5XFAD versus wild-type mice correlate well with histology, showing promise for a fast and practical in vivo technique.

59 BASIC BIOLOGICAL SCIENCES↗

Scalable method for micro-CT analysis enables large scale quantitative characterization of brain lesions and implants

Anatomic evaluation is an important aspect of many studies in neuroscience; however, it often lacks information about the three-dimensional structure of the brain. Micro-CT imaging provides an excellent, nondestructive, method for the evaluation of brain structure, but current applications to neurophysiological or lesion studies require removal of the skull as well as hazardous chemicals, dehydration, or embedding, limiting their scalability and utility. Here we present a protocol using eosin in combination with bone decalcification to enhance contrast in the tissue and then employ monochromatic and propagation phase-contrast micro-CT imaging to enable the imaging of brain structure with the preservation of the surrounding skull. Instead of relying on descriptive, time-consuming, or subjective methods, we develop simple quantitative analyses to map the locations of recording electrodes and to characterize the presence and extent of hippocampal brain lesions.

3-D reconstruction↗

Haze Mitigation in High-Resolution Satellite Imagery using Enhanced Style-Transfer Neural Network and Normalization Across Multiple GPUs

Despite recent advances in deep learning approaches, haze mitigation in large satellite images is still a challenging problem. Due to amorphous nature of haze, object detection or image segmentation approaches are not applicable. Also it is practically infeasible to obtain ground truths for training. Bounded memory capacity of GPUs is another constraint that limits the size of image to be processed. In this paper, we propose a style transfer based neural network approach to mitigate haze in a large overhead imagery. The network is trained without paired ground truths; further, perception loss is added to restore vivid colors, enhance contrast and minimize artifacts. The paper also illustrates our use of multiple GPUs in a collective way to produce a single coherent clear image where each GPU dehazes different portions of a large hazy image.

Park, Byung↗

Associations between regional blood-brain barrier permeability, aging, and Alzheimer’s disease biomarkers in cognitively normal older adults

Background Increased blood-brain barrier permeability (BBBp) has been hypothesized as a feature of aging that may lead to the development of Alzheimer’s disease (AD). We sought to identify the brain regions most vulnerable to greater BBBp during aging and examine their regional relationship with neuroimaging biomarkers of AD. Methods We studied 31 cognitively normal older adults (OA) and 10 young adults (YA) from the Berkeley Aging Cohort Study (BACS). Both OA and YA received dynamic contrast-enhanced MRI (DCE-MRI) to quantify K trans values, as a measure of BBBp, in 37 brain regions across the cortex. The OA also received Pittsburgh compound B (PiB)-PET to create distribution volume ratios (DVR) images and flortaucipir (FTP)- PET to create partial volume corrected standardized uptake volume ratios (SUVR) images. Repeated measures ANOVA assessed the brain regions where OA showed greater BBBp than YA. In OA, K trans values were compared based on sex, Aβ positivity status, and APOE4carrier status within a composite region across the areas susceptible to aging. We used linear models and sparse canonical correlation analysis (SCCA) to examine the relationship between K trans and AD biomarkers. Results OA showed greater BBBp than YA predominately in the temporal lobe, with some involvement of parietal, occipital and frontal lobes. Within an averaged ROI of affected regions, there was no difference in K trans values based on sex or Aβ positivity, but OA who were APOE4carriers had significantly higher K trans values. There was no direct relationship between averaged K trans and global Aβ pathology, but there was a trend for an Ab status by tau interaction on K trans in this region. SCCA showed increased K trans was associated with increased PiB DVR, mainly in temporal and parietal brain regions. There was not a significant relationship between K trans and FTP SUVR. Discussion Our findings indicate that the BBB shows regional vulnerability during normal aging that overlaps considerably with the pattern of AD pathology. Greater BBBp in brain regions affected in aging is related to APOE genotype and may also be related to the pathological accumulation of Aβ.

Science & Technology - Other Topics↗

Reconstruction of the 4D beam matrix

The widely used transverse parameters characterizing particle beams are the Twiss parameters. These parameters can be measured experimentally but they do not fully characterize the beam since they do not account for possible correlations in particle distribution between two transverse coordinates. These correlations may occur due to uncompensated magnetic field at the cathode or misalignment of focusing quadrupoles in the transport beamline. We test a novel diagnostic for diagnosing full 4D beam matrix which may be used to identify such imperfections. The diagnostic is based on transporting the beam through the beamline which includes a quadrupole and a skew quadrupole magnets and measuring the resulting 2D beam distribution at the screen downstream. Such a measurement can be viewed as measuring a 2D projection of the 4D distribution. Different settings of the quads provide measurements of different slices of the phase space. The reconstruction of the original beam matrix from a number of measurements is done using machine learning algorithm, which provides a fast and reliable way of reconstruction for an arbitrary configuration of the scanning beamline. In August 2024, we set up the diagnostic beamline to perform a quadrupole scan of the beam. The setup includes a skew quadrupole, a regular quadrupole, and a screen. The images on the screen were post-processed to remove experimental artifacts and enhance contrast by eliminating background noise outside the core of the distribution=. The rms parameters of the distribution were then calculated and used as inputs for the reconstruction algorithm. This algorithm attempts to determine the initial beam matrix that produces expected images on the screen closely matching the observed images across all quadrupole settings. The algorithm found a solution in which the expected rms parameters closely align with the observations. Validation of the results is planned for FY25.

43 PARTICLE ACCELERATORS↗

Shielding development for the VENUS imaging instrument

VENUS is an imaging instrument that will use a broad range of neutron wavelengths, from epithermal to cold, will include enhanced contrast mechanisms, and will offer novel energy-selective imaging techniques that directly connect the structures, properties, and function of complex engineering materials and systems to reveal practical and fundamental answers about their real-world performance. The instrument is to be built at SNS beam line 10 and will face the decoupled poisoned hydrogen moderator. The driving cost for the instrument is the beam line and instrument cave shielding. Initial scoping analyses were performed to estimate thickness and composition of shielding materials for the instrument cave and beam line. In light of the upcoming Proton Power Upgrade (PPU) project, these transport analyses were performed for proton beam on target at 1.3 GeV and 2 MW.

Popova, Irina I.↗

A versatile enhanced freeze-substitution protocol for volume electron microscopy

Volume electron microscopy, a powerful approach to generate large three-dimensional cell and tissue volumes at electron microscopy resolutions, is rapidly becoming a routine tool for understanding fundamental and applied biological questions. One of the enabling factors for its adoption has been the development of conventional fixation protocols with improved heavy metal staining. However, freeze-substitution with organic solvent-based fixation and staining has not realized the same level of benefit. Here, we report a straightforward approach including osmium tetroxide, acetone and up to 3% water substitution fluid (compatible with traditional or fast freeze-substitution protocols), warm-up and transition from organic solvent to aqueous 2% osmium tetroxide. Once fully hydrated, samples were processed in aqueous based potassium ferrocyanide, thiocarbohydrazide, osmium tetroxide, uranyl acetate and lead acetate before resin infiltration and polymerization. We observed a consistent and substantial increase in heavy metal staining across diverse and difficult-to-fix test organisms and tissue types, including plant tissues ( Hordeum vulgare ), nematode ( Caenorhabditis elegans ) and yeast ( Saccharomyces cerevisiae ). Our approach opens new possibilities to combine the benefits of cryo-preservation with enhanced contrast for volume electron microscopy in diverse organisms.

59 BASIC BIOLOGICAL SCIENCES↗

Embedded Sensing in Additive Manufacturing Metal and Polymer Parts: A Comparative Study of Integration Techniques and Structural Health Monitoring Performance

This study presents a comparative evaluation of post-process sensor integration in additively manufactured (AM) metal and the in-situ process for polymer structures for structural health monitoring (SHM), with an emphasis on embedded sensors. Geometrically identical specimens were fabricated using copper via metal fused filament fabrication (FFF) and PLA via polymer FFF, with piezoelectric transducers (PZTs) inserted into internal cavities to assess the influence of material and placement on sensing fidelity. Mechanical testing under compressive and point loads generated signals that were transformed into time–frequency spectrograms using a Short-Time Fourier Transform (STFT) framework. An engineered RGB representation was developed, combining global amplitude scaling with an amplitude-envelope encoding to enhance contrast and highlight subtle wave features. These spectrograms served as inputs to convolutional neural networks (CNNs) for classification of load conditions and detection of damage-related features. Results showed reliable recognition in both copper and PLA specimens, with CNN classification accuracies exceeding 95%. Embedded PZTs were especially effective in PLA, where signal damping and environmental sensitivity often hinder surface-mounted sensors. This work demonstrates the advantages of embedded sensing in AM structures, particularly when paired with spectrogram-based feature engineering and CNN modeling, advancing real-time SHM for aerospace, energy, and defense applications.

additive manufacturing↗

Computer program for Video Data Processing System /VDPS/

Video data from spacecraft photographic mission telemetry is scanned to generate digital tape computer program which prints out intensity points, cleans noise and telemetry drop-out, enhances contrast, modifies the picture, and calculates contour lines. The output is converted into new photographic film.

Billingsley, F. C.↗

Water depth estimation with ERTS-1 imagery

Contrast-enhanced 9.5 inch ERTS-1 images were produced for an investigation on ocean water color. Such images lend themselves to water depth estimation by photographic and electronic density contouring. MSS-4 and -5 images of the Great Bahama Bank were density sliced by both methods. Correlation was found between the MSS-4 image and a hydrographic chart at 1:467,000 scale, in a number of areas corresponding to water depth of less than 2 meters, 5 to 10 meters and 10 to about 20 meters. The MSS-5 image was restricted to depths of about 2 meters. Where reflective bottom and clear water are found, ERTS-1 MSS-4 images can be used with density contouring by electronic or photographic methods for estimating depths to 5 meters within about one meter.

Ross, D. S.↗

Variable features on Mars - Preliminary Mariner 9 television results.

Systematic Mariner 9 photography of a range of Martian surface features, observed with all three photometric angles approximately invariant, reveals three general categories of albedo variations: (1) an essentially uniform contrast enhancement due to the dissipation of the dust storm; (2) the appearance of splotches, irregular dark markings at least partially related to topography; and (3) the development of both bright and dark linear streaks, generally emanating from craters. Some splotches and streaks vary on characteristic timescales of about two weeks; they have characteristic dimensions of kilometers to tens of kilometers. The morphology and variability of streaks and splotches, and the resolution of at least one splotch into an extensive dune system, implicate windblown dust as the principal agent of Martian albedo differences and variability.

Sagan, C.↗

Remote identification of soil conditions with ratioed multispectral data

Some of the information concerning soils that a multispectral scanner system may provide is discussed, and a practical approach for realizing this potential is suggested. Some reflectance and emittance characteristics of soil surfaces are reviewed, and the feasibility of selectively enhancing contrasts associated with differing soil conditions is demonstrated. The simplicity of the proposed ratio technique, its relative economy, and the compatibility of the image output with conventional survey methods commends it for consideration as an operational method.

Wagner, T. W.↗

Interactive imaging and data processing

Image processing method is capable of contrast enhancement, noise filtering, and photometric distortion removal in near real time. System uses digital image integration and digital video recorder as image buffer. Each frame of data is entered into memory; registers provide readout of stored TV frame.

Alsberg, H.↗

Guide to the use of Mariner images

Planetary imaging from unmanned spacecraft, almost exclusively done by digital systems, is examined. The Mars Mariner 9 television camera, representative of such systems, is considered. Each image consists of 700 lines, each containing 832 picture elements, or pixels. Each pixel contains nine binary bits of information capable of displaying 512 discrete brightness levels. Several problems inherent in television systems are discussed. These include nonuniform target response, residual images, noise, and blemishes. These defects can be removed to some extent by decalibration of the image. The final product is geometrically corrected for camera distortion and photometrically corrected. Several versions of the decalibrated images are available. The most generally useful are the geometrically corrected images with enhanced contrast. The Mariner 10 imaging of Mercury is briefly discussed.

Saunders, R. S.↗

Numerical image manipulation and display in solar astronomy

The paper describes the system configuration and data manipulation capabilities of a solar image display system which allows interactive analysis of visual images and on-line manipulation of digital data. Image processing features include smoothing or filtering of images stored in the display, contrast enhancement, and blinking or flickering images. A computer with a core memory of 28,672 words provides the capacity to perform complex calculations based on stored images, including computing histograms, selecting subsets of images for further analysis, combining portions of images to produce images with physical meaning, and constructing mathematical models of features in an image. Some of the processing modes are illustrated by some image sequences from solar observations.

Levine, R. H.↗