Search NASA⌕ Search

SEARCH · Search NASA

Results for “control systems control system analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Transmission and Distribution Real-Time Analysis Software for Monitoring and Control: Design and Simulation Testing

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. This paper introduces software designed to meet these challenges. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. The software architecture along with selected analysis modules is presented. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hardware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

14 SOLAR ENERGY↗

A Comprehensive Analysis of Energy and Daylighting Impact of Window Shading Systems and Control Strategies on Commercial Buildings in the United States

Commercial buildings consume approximately 1.9 EJ of energy in the United States, 50% of which is for heating, cooling, and lighting applications. It is estimated that windows contribute up to 34% of the energy used for heating and cooling. However, window retrofits are not often undertaken to increase energy efficiency because of the high cost and disruptive nature of window installation. Highly efficient window technologies would also need shading devices for glare prevention and visual comfort. An automated window shading system with an appropriate control strategy is a technology that can reduce energy demand, maintain occupant comfort, and enhance the aesthetics and privacy of the built environment. However, the benefits of the automated shades currently used by the shading industry are not well studied. The topic merits an analysis that will help building owners, designers and engineers, and utilities make informed decisions using knowledge of the impact of this technology on energy consumption, peak demand, daylighting, and occupant comfort. This study uses integrated daylight and whole-building energy simulation to evaluate the performance of various control strategies that the shading industry uses in commercial office buildings. The analysis was performed for three different vintages of medium office buildings at six different locations in United States. The results obtained show the control strategies enabled cooling energy savings of up to 40% using exterior shading, and lighting energy savings of up to 25%. The control strategies described can help building engineers and researchers explore different control methods used to control shading in actual buildings but rarely discussed in the literature. This information will give researchers the opportunity to investigate potential improvements in current technologies and their performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential Heating Energy and Cost Savings of Dual Fuel Heat Pump Controls as a Residential Building Equipment Retrofit in the U.S.

This study investigated the energy and cost savings potential by modeling a dual fuel heat pump system with its control for a residential building in (5A) cold climate in U.S. The simulation analysis showed that the application of the DFHP system and its control to the target building can save the heating energy by 42% over a gas furnace system (baseline system). Although the HP-only system can save more heating energy (i.e., 53%) over the baseline system than DFHP system does, the DFHP with its control demonstrated the higher cost savings when a time of use electricity rate was considered.

Yoon, Yeobeom↗

Advances in supervisory control strategies for a heat pump centric HVAC system − a comprehensive review on applications

There is an increase in research investigating the development and deployment of supervisory controllers that enable high efficiency electrically driven vapor compression heat pumps operating within grid interactive efficient buildings to provide demand side management. This paper reviews over sixty relevant case studies within this domain that focus on commercial off-the-shelf heat pumps whose primary task is providing space conditioning. The concept of a heat pump-centric heating, ventilation, and air-conditioning system is introduced, accompanied by a detailed overview of various kinds of electric heat pumps and building-level thermal energy storage configurations. Additionally, the different types of supervisory controller designs, including rule-based control and model predictive control, are discussed, along with the various methods for communication between a supervisory controller and a downstream heat pump’s local controller. A comparative analysis is conducted in order to categorize the reviewed case studies based on their system design, supervisory control algorithm, and validation methodology. This detailed analysis allows the review to establish current research trends, identify potential gaps, and suggest future directions for the development of this technology. Overall, the authors recommend that more future research be devoted to low-cost practical retrofits that allow for easy integration of active thermal energy storage within heat pump-centric heating, ventilation, and air-conditioning system systems that utilize direct expansion heat pumps. We also suggest more research into the development and deployment of supervisory controllers that can properly communicate with commercial off-the-shelf heat pump local controller available control inputs, e.g., zone temperature setpoint. Lastly, more rigorous experimental demonstrations of advanced supervisory control within real and or closed-loop, transient/ quasi-steady state environments are necessary to reduce industry wide skepticism of this technology.

Demand side management↗

Power Decoupling Method for Voltage Source Inverters Using Grid Voltage Modulated Direct Power Control in Unbalanced System

The grid voltage modulated direct power control (GVM-DPC) is a novel power regulation method for grid-connected voltage source inverters (VSI). However, interactions between real and reactive powers still exist in GVM-DPC under unbalanced grid voltage condition, which may deteriorate its transient performance. Here, this article proposes a power decoupling method for GVM-DPC-based VSI in unbalanced systems based on the dynamic feedforward power compensation strategy, which can reduce the coupling magnitudes of real and reactive powers in the transient stages. First, the power coupling mechanism of positive and negative sequence real and reactive powers of VSI under the unbalanced voltage condition is analyzed. Then, the power coupling magnitudes (PCM) are derived according to relationships among the positive sequence components of real power, reactive power and point of common coupling (PCC) voltages. Next, the PCM are compensated into the GVM-DPC for the better decoupling performance. Furthermore, a stability analysis of the proposed control system is studied based on the impedance model, and a comparison with the traditional power decoupling method based on virtual impedance is conducted to show the superiority of the proposed method. Finally, simulations, hardware-in-loop test and experiment are conducted to validate the effectiveness of the proposed method.

42 ENGINEERING↗

Computationally Efficient Learning of Large Scale Dynamical Systems: A Koopman Theoretic Approach

In recent years there has been a considerable drive towards data-driven analysis, discovery and control of dynamical systems. To this end, operator theoretic methods, namely, Koopman operator methods have gained a lot of interest. In general, the Koopman operator is obtained as a solution to a least-squares problem, and as such, the Koopman operator can be expressed as a closed-form solution that involves the computation of Moore-Penrose inverse of a matrix. For high dimensional systems and also if the size of the obtained data-set is large, the computation of the Moore-Penrose inverse becomes computationally challenging. In this paper, we provide an algorithm for computing the Koopman operator for high dimensional systems in a time-efficient manner. We further demonstrate the efficacy of the proposed approach on two different systems, namely a network of coupled oscillators (with state-space dimension up to 2500) and IEEE 68 bus system (with state-space dimension 204 and up to 24,000 time-points).

Sinha, Subhrajit↗

Remote Monitoring and Diagnostics of Pitch-Bearing Defects in an MW-Scale Wind Turbine Using Pitch Symmetrical-Component Analysis

Recently, multiple wind turbine failure databases have reviewed that the pitch system is one of the subassemblies with the highest failure rates and largest contributors to the overall downtime. Therefore, there has been an increasing interest to provide remote health monitoring for wind turbine pitch system. While most of the research articles are discussing pitch actuation system (hydraulic or electric actuator) faults only, there is very limited research on pitch-bearing-defect detection. This article provides a remote and hardware-free solution to monitor multiaxis pitch-bearing health condition called pitch symmetrical-component analysis. It leverages readily available low-resolution (100 Hz) electrical measurements, mechanical measurements, and control signals from the existing pitch control platform, and innovatively applies symmetrical-component analysis in multiphase ac system to multiaxis pitch control system and introduces multiaxis pitch-bearing degradation trending curves. This hardware-free solution can be directly applied to the existing wind turbines and successfully give the wind farm operator an early warning before multiaxis pitch bearing fails. It has been proved to be accurate, low cost, and has minimum impacts on turbine normal operation, and has been validated by field data from several North America MW-scale wind farms. This approach turns out to be the first hardware-free (no additional hardware needed) method to remotely monitor and diagnose multiaxis wind turbine pitch-bearing condition.

17 WIND ENERGY↗

Revisiting Theoretical Limits for One Degree-of-Freedom Wave Energy Converters

This work revisits the theoretical limits of one degree-of-freedom wave energy converters (WECs). This work considers the floating sphere used in the OES Task 10 WEC modeling and verification effort for analysis. Analytical equations are derived to determine bounds on displacement amplitude, time-averaged power (TAP), and power-take-off (PTO) force. A unique result found shows that the TAP absorbed by a WEC can be defined solely by the inertial properties and radiation hydrodynamic coefficients. In addition, a unique expression for the PTO force was derived that provides lower and upper bounds when resistive control is used to maximize power generation. For complex conjugate control, this same expression only provides a lower bound, as there is theoretically no upper bound. These bounds assist in comparing the performance of the floating sphere if it were to extract energy using surge or heave motion. The analysis shows because of differences in hydrodynamic coefficients for each oscillating mode, there are different frequency ranges that provide better power capture efficiency. The influence of a motion constraint on TAP while utilizing a nonideal power take-off is examined and found to reduce the losses associated with bidirectional energy flow. The expression to calculate TAP with a nonideal PTO is modified by the electrical conversion efficiency and the ratio of the PTO spring and damping coefficients. Furthermore, the PTO spring and damping coefficients were separated in the expression, allowing for limits to be set on the PTO coefficients to ensure net power generation.

16 TIDAL AND WAVE POWER↗

Effect of injected flux and current temporal phasing on self-organization in the HIT-SI3 experiment

The HIT-SI3 device at the University of Washington uses three oscillating inductive helicity injectors to form and sustain spheromak plasma equilibria. By adjusting the temporal phase of the injector waveforms with respect to each other, the toroidal spectrum of the imposed perturbations can be controlled. Using a recently implemented GPU-based control system, the available mode spectra were explored experimentally by scanning the space of relative injector phasing. In this space, significant variation in the toroidal mode spectrum ($n$ = 1, 2, 3) of the perturbations was observed. Additionally, variation in characteristics of driven equilibria was also observed, including a ≈ $30$% range in toroidal current gain ($I$ $Φ$ / $I$ $Inj$ ). Experimental results are compared with both a composite-equilibria and nonlinear dynamic model, including extended MHD simulations using the NIMROD code and composite Taylor state equilibria computed using the PSI-Tet code. In conclusion, qualitative agreement is seen with the nonlinear models, but not with composite-equilibria models, suggesting the use of nonlinear models to better capture observed plasma dynamics and provide predictive use for future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Analysis of an Integral MPPT Control Law for Wave Energy Conversion Systems

In this paper, we propose an integral-based maximum power point tracking (MPPT) algorithm for point absorber wave energy conversion (WEC) systems. A permanent magnet synchronous generator (PMSG) is coupled to the point absorber and its drive implements the proposed MPPT control. While the rotating frame of reference of the PMSG implements power control, the slower mechanical frequency of the incident waves are processed with an additional transformation that yields another set of dc dynamics. The computed dc power in the new reference frame, which is focused on slow wave dynamics, is input to the MPPT control law that tunes the emulated resistance of the machine drive to extract peak power from the wave absorber device. We derive a stability condition for the proposed controller and validate our control design on a simulated 10kW system.

wave energy, maximum power point tracking (MPPT), ↗

On the Limits of EM Based Detection of Control Logic Injection Attacks In Noisy Environments

The difficulty in applying traditional security mechanisms in Industrial Control System (ICS) environments makes a large portion of these mission-critical assets vulnerable to cyber attacks. Therefore, there is a dire need for the development of novel security mechanisms specifically designed to protect such critical systems. Recently a lot of attention has been given to mechanisms that exploit the EM emanations of devices for defense purposes. Such practices may lead to the development of robust external and non-intrusive anomaly detection systems. Nevertheless, the majority of current work in the area neglects to consider the implications of real-life environments, particularly environmental noise. In this work, we explore the limits of EM-based anomaly detection towards identifying injection attacks in control logic software in noisy environments. Our study conducted upon both synthetically generated and real signals identified that indeed environmental noise might significantly degrade the accuracy of the anomaly detection process. Experiments done upon synthetic data indicated that assuming that signals are captured with high sampling rates, even minor code injections can be detected with above-90% accuracy in noisy environments where SNR is up to -2dB. This is true even if naive detection methods are considered. Moreover, experiments done using a real-life testbed attest that even single-instruction injections can be detected with near-perfect accuracy in relatively clean environments. Finally, noise-elimination techniques can drastically improve the reliability of the detection mechanism even in noisy environments.

97 MATHEMATICS AND COMPUTING↗

Framework for Analysis and Quantification of Wide-Area Control Resilience for Power Systems

Wide-area control helps damp the inter-area oscillations in modern power systems. However, compared to traditional local control, it is more vulnerable to cyber attacks due to its dependence on remote real-time-communicated measurements. In this paper, a formal mathematical framework for analyzing resilience of various wide-area controllers under adversarial scenarios is proposed. A novel resilience index based on the $\H_2$ norm of the post-attack closed-loop system is defined. Computation of such an index is, in general, challenging due to the combinatorial nature of the attack profiles and the bilinear nature of the problem. To address these difficulties, a gradient-based path-following-like solution is developed in this paper to solve a relaxed version of the original non-convex problem. Case studies on IEEE 39-bus system are performed to demonstrate the usage of the proposed framework.

Marinovici, Laurentiu D.↗

Development and Analysis of Control Strategies for a 1 MW/3.2 MWh Energy Storage System at Avista Utilities

This report documents the work performed by Pacific Northwest National Laboratory (PNNL) and Washington State University (WSU) supporting an effort to develop control strategies for a 1 MW/3.2 MWh energy storage system (ESS) at Avista Utilities (Avista). The ESS project is funded though the Washington Clean Energy Fund (CEF) program administered by the Washington State Department of Commerce (DOC). A tri-party Cooperative Research and Development Agreement (CRADA), namely the CRADA 360, was created in 2015 to facilitate this work.

25 ENERGY STORAGE↗

Advanced Human-System Interface Risk Analysis Based on Redundancy-guided Systems-theoretic Hazard Analysis and Human Reliability Analysis

Human-system interfaces (HSIs) play an important role in enabling operators to communicate with the nuclear power plant (NPP) side. Getting the information required to understand a NPP’s current status or perform necessary actions for responding to a given operational context are representative operator tasks performed using HSIs. To date, HSIs have been mainly evaluated in the context of human reliability analysis (HRA). However, the current HSI evaluation that occurs during HRA may be challengeable on two fronts: (1) reflecting the unique characteristics of HSI systems and (2) considering situations in which HSIs are poorly operated due to software/hardware malfunctions. Accordingly, this study proposes an approach for specifically evaluating HSIs for digital instrumentation and controls (DI&C) systems, using Redundancy-guided Systems-theoretic Hazard Analysis (RESHA) and HRA. RESHA is a method for analyzing DI&C systems with redundancy features. In this study, we investigate how HSIs are evaluated in existing HRA methods, and what challenges exist in the current approaches. To better evaluate HSIs for DI&C systems, this study modifies the existing HSI evaluation process by additionally modeling the HSI back- and front- ends. In this paper, a HSI fault tree for the APR1400 DI&C system is introduced through a piping and instrumentation diagram. It then touches upon what aspects of the suggested method must be further researched.

99 GENERAL AND MISCELLANEOUS↗

Impact of Increased Inverter-Based Resources on Power System Small-Signal Stability

The transformation of the power system to include more distributed energy resources (DER) implies an increase in the number of inverter-based resources deployed on the grid. Envisioning future scenarios, this paper presents a small-signal stability analysis for a power grid comprising synchronous generators and inverter-based resources. Three types of inverter control are considered: grid following, droop-controlled grid forming, and virtual oscillator control grid forming. Although small-signal stability of power systems is a widely studied topic, systematic analysis of mixed machine-inverter systems with detailed control models at various inverter levels are limited. This paper addresses the gap with numerical simulations tailored to the IEEE 39-bus system. Results show the system may become unstable at high inverter level of grid-following inverters, and grid-forming inverter control can potentially improve system stability, thereby enabling very high level of DERs.

grid-following inverter↗

Impact of Increased Inverter Penetration on Power System Small-Signal Stability: Preprint

The transformation of the power system to include more distributed energy resources (DER) implies an increase in the number of inverter-based resources deployed on the grid. Envisioning future scenarios, this paper presents a small-signal stability analysis for a power grid comprising synchronous generators and inverter-based resources. Three types of inverter control are considered: grid following, droop-controlled grid forming, and virtual oscillator control grid forming. Although small-signal stability of power systems is a widely studied topic, systematic analysis of mixed machine-inverter systems with detailed control models at various inverter penetration levels are limited. This paper addresses the gap with numerical simulations tailored to the IEEE 39-bus system. Results show the system may become unstable at high inverter penetration level of grid-following inverters, and grid-forming inverter control can potentially improve system stability, thereby enabling very high level of DERs.

41 EE - Solar Energy Technologies Office (EE-4S)↗

A Cyber Threat Mitigation Approach For Wide Area Control of SVCs using Stability Monitoring

We propose a stability monitoring approach for the mitigation of cyber threats directed at the wide area control (WAC) system used for coordinated control of Flexible AC Transmission Systems (FACTS) used for power oscillation damping (POD) of active power flow on inter-area tie lines. The approach involves monitoring the modes of the active power oscillation on an inter-area tie line using the Matrix Pencil (MP) method. We use the stability characteristics of the observed modes as a proxy for the presence of destabilizing cyber threats. We monitor the system modes to determine whether any destabilizing modes appear after the WAC system engages to control the POD. If the WAC signal exacerbates the POD performance, the FACTS falls back to POD using local measurements. The proposed approach does not require an expansive system-wide view of the network. We simulate replay, control integrity, and timing attacks for a test system and present results that demonstrate the performance of the SM approach for mitigation.

24 POWER TRANSMISSION AND DISTRIBUTION↗