Search NASA⌕ Search

SEARCH · Search NASA

Results for “controller test bed”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Change of Paradigm for the Reversed Field Pinch

The reversed field pinch (RFP) is a magnetic configuration germane to the tokamak, but it produces most of its magnetic field by the currents flowing inside the plasma; external coils provide only a small edge toroidal field whose sign is reversed with respect to the central one, whence the name of the configuration. Because of the presence of magnetic turbulence and chaos, the RFP had been considered for a long period as a terrible confinement configuration. However, recently a change of paradigm occurred for this device. Indeed, when the toroidal current is increased in the RFX-mod RFP in Padua (Italy), a self-organized helical state with an internal transport barrier (ITB) develops, and a broad zone of the plasma becomes hot (above 1 keV for a magnetic field above 0.8 T). The present theoretical picture of the RFP mainly comes from three-dimensional nonlinear visco-resistive MHD simulations whose dynamics has strong similarities with the experimental one, and triggered the experimental search for RFP states with improved confinement. The RFP ohmic state involves a helical electrostatic potential generating, as an electric drift, the so-called dynamo velocity field. The magnetic topology can bifurcate from a magnetic island to kink-like magnetic surfaces with higher resilience to magnetic chaos. This theoretical scenario was found to be relevant when ITB's enclosing a broad hot domain were discovered. The ITBs occur in the vicinity of the maximum of the safety factor. The new paradigm for the RFP supports its reappraisal as a low-external field, non-disruptive, ohmically heated approach to magnetic fusion, exploiting both self-organization and technological simplicity. Furthermore the RFP has the same Greenwald density limit as the tokamak, and it is an excellent test bed for the efficient control of multiple resistive wall modes. Its helical magnetic structure makes it germane to the stellarator too. As a result the RFP is also useful to bring support to the present two main lines of magnetic confinement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DRI Renewable Energy Center

The primary objective of this project was to utilize a flexible, energy-efficient facility, called the DRI Renewable Energy Experimental Facility (REEF) to support various renewable energy research and development (R&D) efforts, along with education and outreach activities. The REEF itself consists of two separate buildings: (1) a 1200-ft2 off-grid capable house and (2) a 600-ft2 workshop/garage to support larger-scale experimental work. Numerous enhancements were made to DRI's existing renewable power generation systems, and several additional components were incorporated to support operation of the REEF House. The power demands of this house are satisfied by integrating and controlling PV arrays, solar thermal systems, wind turbines, an electrolyzer for renewable hydrogen production, a gaseous-fuel internal combustion engine/generator set, and other components. Cooling needs of the REEF House are satisfied by an absorption chiller, driven by solar thermal collectors. The REEF Workshop includes a unique, solar air collector system that is integrated into the roof structure. This system provides space heating inside the Workshop, as well as a hot water supply. The Workshop houses a custom-designed process development unit (PDU) that is used to convert woody biomass into a friable, hydrophobic char that has physical and chemical properties similar to low grade coal. Besides providing sufficient space for operation of this PDU, the REEF Workshop supplies hot water that is used in the biomass treatment process. The DRI-REEF serves as a working laboratory for evaluating and optimizing the performance of renewable energy components within an integrated, residential-like setting. The modular nature of the system allows for exploring alternative configurations and control strategies. This experimental test bed is also highly valuable as an education and outreach tool both in providing an infrastructure for student research projects, and in highlighting renewable energy features to the public.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Security Programs - Cyber: MMAREJBLIGE – Modular Multi Agent Grid Emulation for Joined Breakdowns in Linked Generative Emulations - 23-0644

Modular Multi Agent Grid Emulations for Joined Breakdowns in Linked Generative Emulations (MMAREJBLIGE) introduces an agent-based modeling framework into real-time cyber-physical emulation to achieve a context-aware environment that introduces operator/attacker/external-condition variability to improve emulation fidelity and testing rigor. We detail our agent framework design, internal communication via message passing, and time synchronization, as well as the individual components of the system. We include a brief analysis of several scenarios run on a real-time, hardware-in-the-loop, Industrial Control Systems (ICS) test-bed which include normal operation, physical disruption, disruption with mitigation, and disruption with mitigation during a cyber denial-of-service (DOS) attack.

42 ENGINEERING↗

A comparison of WEC control strategies

The operation of Wave Energy Converter (WEC) devices can pose many challenging problems to the Water Power Community. A key research question is how to significantly improve the performance of these WEC devices through improving the control system design. This report summarizes an effort to analyze and improve the performance of WEC through the design and implementation of control systems. Controllers were selected to span the WEC control design space with the aim of building a more comprehensive understanding of different controller capabilities and requirements. To design and evaluate these control strategies, a model scale test-bed WEC was designed for both numerical and experimental testing (see Section 1.1). Seven control strategies have been developed and applied on a numerical model of the selected WEC. This model is capable of performing at a range of levels, spanning from a fully-linear realization to varying levels of nonlinearity. The details of this model and its ongoing development are described in Section 1.2.

30 DIRECT ENERGY CONVERSION↗

CARBON BED MERCURY EMISSIONS CONTROL FOR MIXED WASTE TREATMENT

Mercury has had various uses in nuclear fuel reprocessing and other nuclear processes, and so is often present in radioactive and mixed (both radioactive and hazardous according tohe Resource Conservation and Recovery Act) wastes. Depending on regulatory requirements, the mercury in the off-gas must be controlled with sometimes very high efficiencies. Compliance to the Hazardous Waste Combustor (HWC) Maximum Achievable Control Technology (MACT) standards can require off-gas mercury removal efficiencies up to 99.999% for thermally treating some mixed waste streams. Several test programs have demonstrated this level of off-gas mercury control using fixed beds of granular sulfur-impregnated activated carbon. Other results of these tests include: (a) The depth of the mercury control mass transfer zone was less than 15-30 cm for the operating conditions of these tests, (b) MERSORB® carbon can sorb Hg up to 19 wt% of the carbon mass, and (c) the spent carbon retained almost all (98 – 99.99%) of the Hg; but when even a small fraction of the total Hg dissolves, the spent carbon can fail the TCLP test when the spent carbon contains high Hg concentrations. Localized areas in a carbon bed that become heated through heat of adsorption, to temperatures where oxidation occurs, are referred to as “bed hot spots.” Carbon bed hot spots must be avoided in processes that treat radioactive and mixed waste. Key to carbon bed hot spot mitigation are (a) designing for sufficient gas velocity, for avoiding gas flow maldistribution, and for sufficient but not excessive bed depth, (b) monitoring and control of inlet gas flowrate, temperature, and composition, (c) monitoring and control of in-bed and bed outlet gas temperatures, and (d) most important, monitoring of bed outlet CO concentrations. An increase of CO levels in the off-gas downstream of the carbon bed to levels about 50-100 ppm higher than the inlet CO concentration indicate CO formation in the bed, caused by carbon bed hot spots. Corrective actions must be implemented quickly if bed hot spots are detected, using a graded approach and sequence starting with corrective actions that are simple, quick, cause the least impact to the process, and are easiest to recover from. Multiple high and high-high alarm levels should be used, with appropriate corrective actions for each level.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a Hardware-in-The-Loop Testbed for a Decentralized, Data-Driven Electric Vehicle Charging Control Algorithm

This study presents the design of an electric vehicle (EV)-grid integration (EVGI) hardware test-bed to implement smart EV charging algorithms. Here, the proposed test-bed also allows to create different grid events via flexible integration of other power hardware (e.g., controllable loads and battery energy storage systems) and test their impacts on EV charging. The design uses a real-time digital simulator to realize a complex distribution grid model with primary and secondary networks. A grid simulator physically realizes the selected nodes of the simulated grid to power an actual EV, forming a hardware-in-the-loop (HIL) test setup. The EV-grid integration is demonstrated based on the custom hardware and software implementation of the J1772 charging protocol using dSPACE MicroLabBox, operating as a custom EV Supply Equipment (EVSE). The HIL test-bed features a novel testing platform for accurate implementation and analysis of scalable charging algorithms. To this end, a data-driven, decentralized, model-free charging controller based on the Additive Increase and Multiplicative Decrease (AIMD) algorithm is presented and validated on an EV using the HIL test-bed. We tested the proposed algorithm under various case studies, and presented a comparison study with an existing droop-based, decentralized charging solution. The results showed that the EV successfully performed charging commands generated by the EVSE and regulated its charging power to effectively reduce the system loading caused by high EV penetration.

33 ADVANCED PROPULSION SYSTEMS↗

A Test Bed to Evaluate Advanced Distribution Management Systems for Modern Power Systems

This paper presents a test bed that utilities, vendors, and researchers can use to evaluate the performance of existing and emerging advanced distribution management systems (ADMS) or specific applications of such systems. The test bed provides a realistic laboratory test setting, including detailed modeling of the power system, controller and/or power hardware, and industry-standard communication protocols. The test bed can further represent the current state of a specific utility's distribution system or the anticipated state with increased penetrations of distributed energy resources, such as rooftop photovoltaic systems, residential battery energy storage systems, electric vehicles, and loads with smart controls. The paper describes the design and implementation of the test bed. We present two use cases of the test bed and preliminary results for these two use cases. We also discuss upcoming and potential future use cases. Results from test bed experiments are intended to accelerate industry deployment of ADMS technologies and advance development of ADMS capabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Test Bed to Evaluate Advanced Distribution Management Systems for Modern Power Systems: Preprint

This paper presents a test bed that utilities, vendors, and researchers can use to evaluate the performance of existing and emerging advanced distribution management systems (ADMS) or specific applications of such systems. The test bed provides a realistic laboratory test setting, including detailed modeling of the power system, controller and/or power hardware, and industry-standard communication protocols. The test bed can further represent the current state of a specific utility's distribution system or the anticipated state with increased penetrations of distributed energy resources, such as rooftop photovoltaic systems, residential battery energy storage systems, electric vehicles, and loads with smart controls. The paper describes the design and implementation of the test bed. We present two use cases of the test bed and preliminary results for these two use cases. We also discuss upcoming and potential future use cases. Results from test bed experiments can be used to accelerate industry deployment of ADMS technologies and advance development of ADMS capabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ATC Security Vulnerability Assessment

The National Supervisory Control and Data Acquisition (SCADA) Test Bed (NSTB) program, directed by the Department of Energy’s Office of Electricity Delivery and Energy Reliability (DOE-OE), was established to support industry and government in reducing control system vulnerabilities in the energy sector. Vulnerability assessments of several SCADA/Energy Management System (EMS) architectures have been performed at Idaho National Laboratory (INL), and it is desired that these studies be extended to a utility facility to validate results, mitigate vulnerabilities, build skills, and develop partnerships with the industry. The American Transmission Company (ATC) was selected for this assessment.

Source record↗

A Data-Driven Voltage Control Strategy for Distribution Grids With Distributed Energy Resources

Traditionally, distribution system control approaches have been model-based. The deployment of advanced metering infrastructure has provided electric utilities with the capability of data-driven control with real-time measurements. The shift from model-based to data-driven control represents a significant advancement in the management of distribution systems, offering a more adaptive approach to system control because of the ability to dynamically adapt to changing conditions without the need for system modeling. Here, in this paper, a behavioral data-driven control method is developed to provide voltage regulation to an actual distribution system by controlling the legacy devices and distributed energy resource (DER) assets. The studied distribution system has a load tap changer and three capacitor banks as the legacy devices and photovoltaic systems as the DERs. The performance of the proposed control algorithm is validated using a laboratory test bed setup considering multiple scenarios. The results show that the proposed control achieved 99% voltage regulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber Security Testing and Training Programs for Industrial Control Systems

Service providers rely on industrial control systems (ICS) to manage the flow of water at dams, open breakers on power grids, control ventilation and cooling in nuclear power plants, and more. In today's interconnected environment, this can present a serious cyber security challenge. To combat this growing challenge, government, private industry, and academia are working together to reduce cyber risks. The Idaho National Laboratory (INL) is a key contributor to the Department of Energy National SCADA Test Bed (NSTB) and the Department of Homeland Security (DHS) Control Systems Security Program (CSSP), both of which focus on improving the overall security posture of ICS in the national critical infrastructure. In support of the NSTB, INL hosts a dedicated SCADA testing facility which consists of multiple control systems supplied by leading national and international manufacturers. Within the test bed, INL researchers systematically examine control system components and work to identify vulnerabilities. In support of the CSSP, INL develops and conducts training courses which are designed to increase awareness and defensive capabilities for IT/Control System professionals. These trainings vary from web-based cyber security trainings for control systems engineers to more advanced hands-on training that culminates with a Red Team/ Blue Team exercise that is conducted within an actual control systems environment. INL also provides staffing and operational support to the DHS Industrial Control Systems Cyber Emergency Response Team (ICS-CERT) Security Operations Center which responds to and analyzes control systems cyber incidents across the 18 US critical infrastructure sectors.

13 HYDRO ENERGY↗

Development of an integrated platform for hardware-in-the-loop evaluation of microgrids prior to site commissioning

This paper presents an integrated hardware-in-the-loop (HIL) platform for testing the operation and control of a real-world microgrid system prior to site commissioning. The proposed testing approach shows the value of setting up an integrated HIL platform to test multiple hardware devices (including the system-level controller, device controllers, and field devices). A test bed developed for the Borrego Springs community microgrid is used as an example to demonstrate the feasibility of the integrated platform. Comprehensive tests are carried out using the Borrego Springs test bed to validate the platform, meet the test objectives, and gain valuable insight prior to site commissioning. The selected test scenarios, initial conditions, events, test metrics, etc., are similar to those defined in IEEE P2030.8. The test objectives are to evaluate the microgrid controller and the operation of the microgrid. The HIL platform presented in this paper shows good value for microgrid testing in terms of its flexibility and scalability for testing various microgrids; its accuracy in its representation of the field; the comprehensiveness of the testing capability; and the efficiency of testing, which can reduce risks prior to field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Validation of an Explicit Power-Flow Primary Control in Microgrids

The existing approaches to control electrical grids combine frequency and voltage controls at different time-scales. When applied in microgrids with stochastic distributed generation, grid quality of service problems may occur, such as under- or overvoltages as well as congestion of lines and transformers. The COMMELEC framework proposes to solve this compelling issue by performing explicit control of power flows with two novel strategies: 1) a common abstract model is used by resources to advertise their state in real time to a grid agent; and 2) subsystems can be aggregated into virtual devices that hide their internal complexity in order to ensure scalability. While the framework has already been published in the literature, in this paper, we present the first experimental validation of a practicable explicit power-flow primary control applied in a real-scale test-bed microgrid. We demonstrate how an explicit power-flow control solves the active and reactive power sharing problem in real time, easily allowing the microgrid to be dispatchable in real time (i.e., it is able to participate in energy markets) and capable of providing frequency support, while always maintaining quality of service.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Recent results from a testbed for the reliability of the digital instrumentation and control systems and cybersecurity in nuclear power plants - 392

Transition from analog to digital instrumentation and control systems requires a systematic study of the modifications, and assessment of their reliability. Such studies are often carried out on a test bed. The test bed developed earlier includes a commercially available triple modular redundant (TMR) programmable logic controller (PLC) for testing not only the reliability of the digital I and C but also the cyber-security of the system during plant operation. This paper reports results of our preliminary analyses carried out using the test bed following the injection of faults mimicking faulty sensors. The fault injection tool generates faulty signals in single or multiple sensors located in the primary loop. These scenarios studied under steady-state operation conditions simulate a bad sensor, a cut wire, noise, etc. The faults injected can lead to information being displayed in the main control room (MCR) to not match the conditions in the plant. In addition to a fault injection module, a result analyzer module is also a part of this testbed. Operator actions can be based on information displayed in the MCR, or they can be informed by the result analyzer. Potential operator actions following these single- or multiple faulty signals are assessed. It is concluded that the result analyzer in some cases can be helpful in guiding operators to make the right decisions. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Transition to Online Cable Insulation Condition Monitoring

Nuclear power plant cables were originally qualified for 40 year life and generally have not required specific test verification to assure service availability through the initial plant qualification period. However, license renewals to 60 and 80 years of operation require a cable aging management program that depends on some form of test and verification to assure fitness for service. Environmental stress (temperature, radiation, chemicals, water, and mechanical) varies dramatically within a nuclear power plant and, in some cases, cables have degraded and required repair or replacement before their qualified end-of-life period. In other cases, cable conditions have been mild and dependable cable performance confirmed to extend well beyond the initial qualified life. Most offline performance-based testing requires cables to be de-coupled and de-energized for specially trained technicians to perform testing. These offline tests constitute an expensive operational burden that limits the economic viability of nuclear power plants. Although initial investment may be higher, new online test practices are emerging as options or complements to offline testing that avoid or minimize the regularly scheduled offline test burden. These online methods include electrical and fiber-optic partial discharge measurement, spread spectrum time or frequency domain reflectometry, distributed temperature profile measurements, and local interdigital capacitance measurement of insulation characteristics. Introduction of these methods must be supported by research to confirm efficacy plus either publicly financed or market driven investment to support the start-up expense of cost-effective instrumentation to monitor cable condition and assure reliable operation. This work summarizes various online cable assessment technologies plus introduces a new cable motor test bed to assess some of these technologies in a controlled test environment.

Glass, Samuel W.↗

Using Qualified On-Site Nuclear Power Plant Simulators in Human Factors Validations of Control Room Upgrades

Existing commercial nuclear power plants (NPPs) are valuable assets in the infrastructure portfolio of the United States (U.S.) because they safely and reliably generate about 1/5th of all the electricity used. The instrumentation and control (I&C) systems in commercial NPPs are the ‘eyes and ears' of the operator, allowing operators to maintain situation awareness, thereby allowing the plant to operate safely and efficiently for all phases of operation. Because the I&C systems in NPPs are still mostly based on analog technologies, which are reliable but not especially cost-effective, upgrading the existing I&C in com-mercial NPPs to new digital I&C is very important. Furthermore, simulators and simulation are critical human factors engineering tools for this I&C modernization work. NPP control room simulators are essential test beds to simulate normal, abnormal, and emergency operations that allow human factors researchers to safely and realistically evaluate early design phase prototypes of the upgraded digital I&C, and validate final as-built digital I&C systems that have been modernized deployed in NPPs. This paper describes research performed using qualified on-site NPP simulators to perform human factors validations of digital I&C control room upgrades.

99 GENERAL AND MISCELLANEOUS↗

OPSAID Initial Design and Testing Report.

Process Control System (PCS) security is critical to our national security. Yet, there are a number of technological, economic, and educational impediments to PCS owners implementing effective security on their systems. OPSAID (Open PCS Security Architecture for Interoperable Design), a project sponsored by the US Department of Energy's Office of Electricity Delivery and Reliability, aims to address this issue through developing and testing an open source architecture for PCS security. Sandia National Laboratories, along with a team of PCS vendors and owners, have developed and tested this PCS security architecture. This report describes their progress to date.2 AcknowledgementsThe authors acknowledge and thank their colleagues for their assistance with the OPSAID project.Sandia National Laboratories: Alex Berry, Charles Perine, Regis Cassidy, Bryan Richardson, Laurence PhillipsTeumim Technical, LLC: Dave TeumimIn addition, the authors are greatly indebted to the invaluable help of the members of the OPSAID Core Team. Their assistance has been critical to the success and industry acceptance of the OPSAID project.Schweitzer Engineering Laboratory: Rhett Smith, Ryan Bradetich, Dennis GammelTelTone: Ori Artman Entergy: Dave Norton, Leonard Chamberlin, Mark AllenThe authors would like to acknowledge that the work that produced the results presented in this paper was funded by the U.S. Department of Energy/Office of Electricity Delivery and Energy Reliability (DOE/OE) as part of the National SCADA Test Bed (NSTB) Program. Executive SummaryProcess control systems (PCS) are very important for critical infrastructure and manufacturing operations, yet cyber security technology in PCS is generally poor. The OPSAID (Open PCS (Process Control System) Security Architecture for Interoperable Design) program is intended to address these security shortcomings by accelerating the availability and deployment of comprehensive security technology for PCS, both for existing PCS and inherently secure PCS in the future. All activities are closely linked to industry outreach and advisory efforts.Generally speaking, the OPSAID project is focused on providing comprehensive security functionality to PCS that communicate using IP. This is done through creating an interoperable PCS security architecture and developing a reference implementation, which is tested extensively for performance and reliability.This report first provides background on the PCS security problem and OPSAID, followed by goals and objectives of the project. The report also includes an overview of the results, including the OPSAID architecture and testing activities, along with results from industry outreach activities. Conclusion and recommendation sections follow. Finally, a series of appendices provide more detailed information regarding architecture and testing activities.Summarizing the project results, the OPSAID architecture was defined, which includes modular security functionality and corresponding component modules. The reference implementation, which includes the collection of component modules, was tested extensively and proved to provide more than acceptable performance in a variety of test scenarios. The primary challenge in implementation and testing was correcting initial configuration errors.OPSAID industry outreach efforts were very successful. A small group of industry partners were extensively involved in both the design and testing of OPSAID. Conference presentations resulted in creating a larger group of potential industry partners.Based upon experience implementing and testing OPSAID, as well as through collecting industry feedback, the OPSAID project has done well and is well received. Recommendations for future work include further development of advanced functionality, refinement of interoperability guidance, additional laboratory and field testing, and industry outreach that includes PCS owner education. 4 5 --This page intentionally left blank --

Hurd, Steven A.↗