At least 73 records · Page 4

Hybrid Cooling and Water Treatment for Resilient, Water-Self-Sufficient Data Centers

The continued growth of data center infrastructure is intensifying demand for freshwater resources, particularly in water-stressed regions, and is increasingly limiting sustainable capacity expansion. This work investigates a conceptual hybrid system that integrates freeze desalination with ultrasonic-assisted ice separation to enable on-site production of pure water from diverse sources, including seawater, brackish groundwater, and reclaimed industrial or agricultural wastewater. Simultaneously, the system produces low-temperature cooling streams that enhance heat removal in high power density computing environments. A process-level thermodynamic analysis is performed across a range of boundary and operating conditions, including variations in feed concentration, freezing temperature, and mass flow rate. The results are presented as performance curves relating feedwater concentration and target purified water output to the corresponding intake flow requirements, enabling estimation of source water demand per unit of Information Technology Equipment (ITE) energy consumption (kWh) across varying data center scales and operational scenarios. The corresponding electrical energy consumption for integrated cooling and water treatment is also evaluated as a function of system operating parameters and target water production levels. These results provide a basis for evaluating system feasibility across different conditions and for identifying parameter ranges in which integrated water treatment and cooling improve resource efficiency, thermal performance, and operational flexibility in data centers.

Elhefny, Aly [ORNL] (ORCID:0000000284907923)↗

Pool boiling heat transfer evaluation of next-generation dielectric fluid: Opteon™ 2P50

The growing use of artificial intelligence has led to heavy thermal loads and high heat dissipation rates in data centers. Conventional air-cooled technologies are not able to fulfill these requirements. To overcome these challenges, two-phase immersion cooling (2PIC) has emerged as one of the leading technologies for high power-density chips. 2PIC increases the heat dissipation rate and efficiency of the system while reducing the footprint of the cooling equipment. A fluid with adequate dielectric properties, a suitable normal boiling temperature to maintain chip temperatures, and good material compatibility, is desired for 2PIC system. In this study, the pool boiling heat transfer of a new developmental dielectric fluid, Opteon™ 2P50, was experimentally investigated. The heat transfer coefficients at various heat fluxes (20–150 kW/m 2 ) and the critical heat flux were measured using a smooth aluminum surface. Compared with HFE-7100, Opteon™ 2P50 shows higher heat transfer coefficient (up to 59% higher) and a slightly lower value of critical heat flux (around 5.9% lower). The modified Cooper correlation with the optimized leading constant resulted in reliable prediction accuracy with a 5.3% mean absolute error percentage. Overall, these results indicate that the new dielectric fluid provides similar thermal performance to some legacy fluids.

2P50↗

Synthesis of Gold Hydride at High Pressure and High Temperature

Gold is an unreactive metal and its chemical interactions with hydrogen have only recently been explored. Here, in this study, we report the formation of gold hydride above 40 GPa and 2200 K in X-ray free electron laser heated diamond anvil cells using various hydrocarbons as hydrogen sources. Above 40 GPa, a hexagonal phase emerges close to the gold melting point, corresponding to a hydride with stoichiometry Au 2 H x , with x increasing from 0 to near 1 with pressure from 40 to 80 GPa. This is a high-temperature phase which reverts to face centered cubic gold on cooling to 295 K. Accompanying DFT-MD simulations are in excellent agreement with experiment and reveal the structure to consist of an hexagonal close packed gold lattice with atomic hydrogen disordered in the interstices. The hydrogen is superionic and exhibits high diffusivity through the crystalline gold lattice. Our results present the first solid-state binary compound of gold and hydrogen.

Ab initio calculations↗

Mo-100 Disk Structural Integrity Tests I

The NorthStar pressed and sintered 29 mm diameter, 0.5 mm thick Mo-100 disks will be subjected to large temperature gradients when in beam during production. The beam preferentially heats the disk center, while the aggressive cooling by the helium keeps areas outside the beam spot relatively cool. The result is a temperature gradient of up to 900°C over the radial distance of 14.5 mm. To test the disk integrity with this high temperature gradient, a special holder for a single disk was made such that proper cooling can be applied as in the design target and the disk heating can be replicated with induction heating. NorthStar press and sintered disks were used for these tests.

36 MATERIALS SCIENCE↗

The environmental footprint of data centers in the United States

Much of the world's data are stored, managed, and distributed by data centers. Data centers require a tremendous amount of energy to operate, accounting for around 1.8% of electricity use in the United States. Large amounts of water are also required to operate data centers, both directly for liquid cooling and indirectly to produce electricity. For the first time, we calculate spatially-detailed carbon and water footprints of data centers operating within the United States, which is home to around one-quarter of all data center servers globally. Our bottom-up approach reveals one-fifth of data center servers direct water footprint comes from moderately to highly water stressed watersheds, while nearly half of servers are fully or partially powered by power plants located within water stressed regions. Approximately 0.5% of total US greenhouse gas emissions are attributed to data centers. We investigate tradeoffs and synergies between data center's water and energy utilization by strategically locating data centers in areas of the country that will minimize one or more environmental footprints. Our study quantifies the environmental implications behind our data creation and storage and shows a path to decrease the environmental footprint of our increasing digital footprint.

54 ENVIRONMENTAL SCIENCES↗

Alpha particle channeling in ITER

Alpha particle channeling, the attempt to extract energy from high-energy fusion alpha particles using a combination of high- and low-frequency waves introduced in the plasma with antennae, is studied using a guiding center code. We examine the effect of the combination of cooling caused by a cyclotron mode, particle diffusion due to Alfvén modes introduced for ash removal, the inclusion of microturbulent diffusion, and the slowing down of the alpha particles on electrons. Induced cooling is achieved with a cyclotron resonance, producing additional losses of particles above 3.5 MeV in an amount about equal to the prompt loss. The removal of the low-energy cooled particles by additional modes or by microturbulent diffusion is the hardest challenge for alpha channeling. The cooled alpha particles remain deep in the plasma center, so for this removal, the method used must be capable of providing transport from the plasma center to the edge without also causing losses of high-energy particles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The roles of kinematic constraint and diffusion in non-equilibrium solid state phase transformations of Ti-6Al-4V

A solid state phase transformation of Ti-6Al-4V was studied using high speed in situ x-ray diffraction measurements made during rapid cooling of a cold metal transfer arc weld bead deposited onto a water cooled substrate. Analysis of body centered cubic (BCC) and hexagonal close packed (HCP) lattices revealed an abrupt, nonlinear shift in the lattice parameters of both phases just after the HCP phase had nucleated. Postmortem transmission electron microscopy confirmed that V diffusion was mostly suppressed during cooling. Together, these results indicate that at this cooling rate of approximately 10 4 K/s, which is representative of cooling rates of many additive manufacturing and welding processes, kinematic coherency of the BCC–HCP interfaces gives rise to the anomalous lattice expansion and contraction behaviors of both phases during the initial nucleation and growth stages of (mostly) martensitic transformation from BCC to HCP; the role of diffusion in such lattice anomalies is shown to be minimal.

36 MATERIALS SCIENCE↗

Improving Thermal Management Strategies for Data Centers: A Physical Testbed Incorporating Small Modular Reactor and Microreactor Technology

This study aims to accelerate the demonstration of various thermal management systems for data centers using nuclear-generated heat to enhance energy and grid reliability. Utilizing mobile containerized and stationary test beds at INL's High Performance Computing (HPC) facility, this project integrates with various nuclear-related energy systems testing facilities. Key components include immersion cooling apparatus, absorption chillers, and adjustable thermal management simulators. Tasks involve acquiring necessary hardware, sensors, and cooling apparatus, engaging with data center industry stakeholders, and providing a testing platform for algorithms, models, tools, and software. The objective is to expedite the deployment of nuclear-powered data centers, thereby improving energy reliability and affordability.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Ion-chain sympathetic cooling and gate dynamics

Sympathetic cooling is a technique often employed to mitigate motional heating in trapped-ion quantum computers. However, choosing system parameters such as number of coolants and cooling duty cycle for optimal gate performance requires evaluating trade-offs between motional errors and other slower errors such as qubit dephasing. The optimal parameters depend on cooling power, heating rate, and ion spacing in a particular system. In this study, we aim to analyze best practices for sympathetic cooling of long chains of trapped ions using analytical and computational methods. We use a case study to show that optimal cooling performance is achieved when coolants are placed at the center of the chain and provide a perturbative upper bound on the cooling limit of a mode given a particular set of cooling parameters. In addition, using computational tools, we analyze the trade-off between the number of coolant ions in a chain and the center-of-mass mode heating rate. We also show that cooling as often as possible when running a circuit is optimal when the qubit coherence time is otherwise long. These results provide a roadmap for how to choose sympathetic cooling parameters to maximize circuit performance in trapped-ion quantum computers using long chains of ions.

Cooling & trapping↗

Data Center Facility Monitoring with Physics Aware Approach

U.S. Department of Energy's National Renewable Energy Laboratory (NREL) hosts one of the world's most energy-efficient HPC data centers; this system uses component-level warm-water liquid cooling to efficiently remove heat from the data center and capture it for reuse in the building or rejection to the atmosphere. Given the complexity of this system, building data-driven tools for holistically monitoring and operating the entire data center is a priority for ensuring maximal efficiency and resiliency. In this advanced smart facility, over one million metrics are recorded per minute using state-of-the-art streaming data architecture and software to capture and process the state of the system in real time. Here we detail two efforts to effectively analyze, visualize, and interpret this large volume streaming data. We have developed a novel, flexible system for identifying and visualizing individual metric anomalies and component performance across the data center through automatic metadata extraction and physically-motivated visualization for quick interpretation. Additionally, to directly connect system maintenance to data stream processing we explore a physics informed multi-metric drift and anomaly detection application to detect scale-build up in heat exchangers.

anomaly detection↗

Motor with Advanced Concepts for High power density and INtegrated cooling for Efficiency (MACHINE)

Raytheon Technologies Research Center (RTRC) is the central research and development (R&D) organization for RTX, and has extensive expertise in the design, modeling and analysis of high-performance electrical machines and thermal management for all its business units. The proposing team consists of researchers from RTRC and John Deere (JD), will be referred as “Team”. Each organization a has long track record of successful R&D of materials, manufacturing, components, and systems for energy efficiency applications. Motor power density and efficiency are limited by fundamental physical trade-offs between electromagnetics, thermal management, and structural design considerations. The team is proposing to utilize novel technologies and multi-physics design methods to develop a Motor with Advanced Concepts for High power density and INtegrated cooling for Efficiency (MACHINE), demonstrating an 8X improvement in power density.

33 ADVANCED PROPULSION SYSTEMS↗

Metal additively manufactured wavy fin cold-plate architecture for improved thermal-hydraulic performance

Rapid growth in artificial intelligence and data center workloads demands high-performance liquid cooling to manage increasing chip power. This study presents two metal-additive-manufactured cold plates with sinusoidal fins, constant-amplitude wavy fins and linearly variable-amplitude wavy fins and compares them against metal-additive-manufactured straight fins using experiments conducted at 1 kW heat dissipation as well as high-fidelity 3D conjugate computational fluid dynamic simulations. The cold plates were printed in AlSi10Mg material and underwent design using a Python-automated workflow prior to manufacture and testing. The experiments show that wavy fins reduce the normalized thermal resistance by 35 to 45 % at water flow rates from 1 to 4 LPM. At a fixed 20 kPa pressure drop, the variable-waviness design lowered peak surface temperature by 9 °C and thermal resistance by 51 %, while edge-channel maldistribution in the constant wavy fin design limited gains. A thermal resistance breakdown revealed that 55–63 % of the total thermal resistance in wavy designs comes from base heat conduction, 27–33 % from fin heat conduction, and 9–13 % from fin heat convection, indicating the need to address conduction bottlenecks. Parametric sweeps identify a 3 mm fin pitch as optimal, and that horizontal inlet/outlet manifolds further reduce pressure drop by 30–60 % and thermal resistance by 9–16 % relative to vertical inlet-outlet manifolds. The results yield comprehensive guidelines for fin geometry, manifold alignment, material selection and additive-manufacturing constraints to realize high-performance liquid-cooled cold plates for power-dense electronics.

3d printing↗

Fermi surface studies of the low-temperature structure of sodium

Sodium is the most abundant alkali-metal element and has one of the simplest electronic structures of any metal. At ambient conditions, sodium forms a body-centered-cubic lattice. However, during cooling, it undergoes a partial martensitic phase transition to a complex mixture of rhombohedral polytypes commencing from 36 K. Although the Fermi surface (FS) of bcc sodium has been extensively studied, not much attention has been given to the FS of the martensite structure. Here we report results for the Fermi surface and quantum oscillation (QO) frequencies of several energetically favorable crystal structures of Na at low temperature from first-principles calculations. Interestingly we find that despite drastic differences in the crystal structures of the candidate low-temperature phases of sodium, for all these phases the strongest quantum oscillation peak is centered at 28 kT. Our theoretical results are accompanied by experimental data of QO on a multigrain sodium sample at T = 0.3 K and B max = 18 T exhibiting a sharp peak at 28 kT, independent of the sample orientation. The persistence of this peak even in the presence of the structural transitions has an implication for using the quantum oscillations of polycrystalline sodium for high magnetic field calibration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An Update on Cardinal: Toward Full Core Pebble Simulations

The new DOE-NE Center of Excellence for Thermal-fluids applications in Nuclear Energy inaugurated in April 2018 considers and researches novel new solution strategies for historically challenging flow issues that still plague the current fleet of deployed Light Water nuclear Reactors (LWRs) as well as predicting various fluid flow and fluid related issues with advanced reactor technologies. Our advanced thermal-fluids research and development approach synergistically combines three natural, though overlapping, length and time scales in a hierarchal multi-scale approach to avoid the temptation and pitfalls of attempting to develop a single solve-all algorithm for physical fluid flow problems that will span nine orders of magnitude in spatial and temporal scales. To demonstrate the multi-scale philosophy of the center we focus on Fluoride Cooled High Temperature Reactors (FHRs), and in particular on the Berkley’s PB-FHR Mark-I design. The Fluoride salt cooled High temperature Reactor (FHR) is a class of advanced nuclear reactors that combine the robust coated particle fuel form from high temperature gas cooled reactors, direct reactor auxiliary cooling system (DRACS) passive decay removal of liquid metal fast reactors, and the transparent, high volumetric heat capacitance liquid Fluoride salt working fluids - such as Flibe - from molten salt reactors. This combination of fuel and coolant enables FHRs to operate in a high-temperature low-pressure design space that has beneficial safety and economic implications. The PB-FHR reactor relies on a pebble bed approach and pebble bed reactors are in a sense the poster child for multi-scale analysis. The lower length-scale simulator for pebble reactor cores comprises three physics: neutronics (OpenMC), thermal-fluids (Nek5000/NekRS) and fuel performance (BISON). As part of Center of Excellence ongoing research efforts we have developed Cardinal, a new tool platform for lower length-scale simulation. Cardinal tightly couples all three physics and leverages advances in MOOSE such as the MultiApp system and the concept of MOOSE-wrapped Apps. The present report provides an update on the development of Cardinal with an extension of Cardinal to GPUs. We also perform a first-of-a-kind demonstration simulation on Summit representing a 10x capability increase in terms of pebble count for Cardinal.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fundamental problems in astroparticle physics and cosmology (Final Technical Report)

In the standard cosmological model, structure forms when gas cools and condenses to the center of dark matter halos. The onset of structure is governed by rapid star formation and subsequent evolution of the first massive stars. One of the endpoints of stellar evolution is the formation of a black hole. We showed that all black hole merger events must occur after the universe is about 85 million years old. This prediction is important because it means that if a future experiment makes a detection of a black hole merger event at an earlier time then our understanding of cosmology and the onset of structure formation is not fully developed. In addition, we explored dark matter models that have either self-interactions or experience decays. In the first case, self-interactions may lead to the formation of a thick disk that can be co-planar to the Galactic disc due to correlations in angular momentum between dark matter and baryons that are predicted by tidal torque theory. We showed that for heavy dark matter particles, either the self interaction may not be strong enough to solve the small scale structure motivation or a dark disc cannot be present in the Milky Way. In the second-case, we showed that if dark matter experiences decays into two particles, one of which behaves like radiation, then it is possible to relieve the tension that exists between measurements of the local expansion rate. Finally, we developed methods on how to distinguish gamma-ray excesses from promising dark matter targets as compared to conventional astrophysical sources. This is an important toolset that is applicable to any suspected dark matter source.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enabling CO 2 Isothermal Compression Using Liquid Piston and Integrated Gas Cooler

This report outlines the development of a near-isothermal liquid piston compressor. Initially, a proof-of-concept experiment was conducted to validate the feasibility and potential of near-isothermal compression. A first-of-its-kind near-isothermal liquid piston compressor was then successfully built and tested. Additionally, a Matlab-based transient model was developed to capture performance trends accurately. These efforts laid the groundwork for developing a second-generation prototype with enhanced efficiency and design. Subsequent field tests at the Helix Innovation Center in Ohio demonstrated a cooling capacity of 2 kW with a COP of 1.64 at an ambient temperature of 25°C. An improved model was also created to suggest different heat exchanger geometries for better compression efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗