Search NASA⌕ Search

SEARCH · Search NASA

Results for “coordinated operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP): Site Energy Management System Platform Development

A site energy management system is a critical component of future high-power EV charging hubs. It monitors and supervises all inter-hub operations, coordinates grid interactions, and implements energy management strategies and load-sharing controls at various levels and time scales. This report provides a comprehensive high-level overview and guidelines on the essential elements of such energy management systems. These elements primarily focus on the core functions, architecture, and monitoring aspects of site energy management. The core functions define the grid services and operational objectives that a charging hub is expected to provide and achieve. The architectural section investigates the coordination between hub assets, different control schemes, and their potential benefits and drawbacks. Lastly, the report discusses the needs, types, and functionalities of a monitoring and visualization system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Safe Cooperative Framework for Atmospheric Science Missions with Multiple Heterogeneous UAS using Piecewise Bezier Curves

Autonomous operation of UAS holds promise for greater productivity of atmospheric science missions. However, several challenges need to be overcome before such missions can be made autonomous. This paper presents a framework for safe autonomous operations of multiple vehicles, particularly suited for atmospheric science missions. The framework revolves around the use of piecewise Bezier curves for trajectory representation, which in conjunction with path-following and time-coordination algorithms, allows for safe coordinated operations of multiple vehicles.

Mehdi, S. Bilal↗

Exactly solvable problems in the momentum space with a minimum uncertainty in position

A new approach in solution of simple quantum mechanical problems in deformed space with minimal length is presented. We propose the generalization of Schrödinger equation in momentum representation on the case of deformed Heisenberg algebra with minimal length. Assuming that the kernel of potential energy operator does not change in the case of deformation, we obtain exact solution of eigenproblem of a particle in delta potential as well as double delta potential. Particle in Coulomb like potential is revisited and the problem of inversibility and hermicity of inverse coordinate operator is solved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Three-Phase Microgrid Restoration Model Considering Unbalanced Operation of Distributed Generation

Recent severe outages highlight the urgency of improving grid resiliency in the U.S. Microgrid formation schemes are proposed to restore critical loads after outages occur. Most distribution networks have unbalanced configurations that are not represented in sufficient detail by single-phase models. This study provides a microgrid formation plan that adopts a three-phase network model to represent unbalanced distribution networks. The problem formulation has a quadratic objective function with mixed-integer linear constraints. The three-phase network model enables us to examine the three-phase power outputs of distributed generators (DGs), preventing unbalanced operation that might trip DGs. Because the DG unbalanced operation constraint is non-convex, an iterative process is presented that checks whether the unbalanced operation limits for DGs are satisfied after each iteration of optimization. We also develop a relatively conservative linear approximation on the unbalanced operation constraint to handle larger networks. Compared with the iterative solution process, the conservative linear approximation is able to accelerate the solution process at the cost of sacrificing optimality to a limited extent. Simulation in the IEEE 34 node and IEEE 123 test feeders indicate that the proposed method yields more practical microgrid formations results. In addition, this paper explores the coordinated operation of DGs and energy storage (ES) installations. The unbalanced three-phase outputs of ESs combined with the relatively balanced outputs of DGs could supply unbalanced loads. In conclusion, the case study also validates the DG-ES coordination.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a Deployable Nonmetallic Boom for Reconfigurable Systems of Small Modular Spacecraft

Launch vehicle payload capacity and the launch environment represent two of the most operationally limiting constraints on space system mass, volume, and configuration. Large-scale space science and power platforms as well as transit vehicles have been proposed that greatly exceed single-launch capabilities. Reconfigurable systems launched as multiple small modular spacecraft with the ability to rendezvous, approach, mate, and conduct coordinated operations have the potential to make these designs feasible. A key characteristic of these proposed systems is their ability to assemble into desired geometric (spatial) configurations. While flexible and sparse formations may be realized by groups of spacecraft flying in close proximity, flyers physically connected by active structural elements could continuously exchange power, fluids, and heat (via fluids). Configurations of small modular spacecraft temporarily linked together could be sustained as long as needed with minimal propellant use and reconfigured as often as needed over extended missions with changing requirements. For example, these vehicles could operate in extremely compact configurations during boost phases of a mission and then redeploy to generate power or communicate while coasting and upon reaching orbit. In 2005, NASA funded Phase 1 of a program called Modular Reconfigurable High-Energy Technology Demonstrator Assembly Testbed (MRHE) to investigate reconfigurable systems of small spacecraft. The MRHE team was led by NASA's Marshall Space Flight Center and included Lockheed Martin's Advanced Technology Center (ATC) in Palo Alto and its subcontractor, ATK. One of the goals of Phase 1 was to develop an MRHE concept demonstration in a relevant 1-g environment to highlight a number of requisite technologies. In Phase 1 of the MRHE program, Lockheed Martin devised and conducted an automated space system assembly demonstration featuring multipurpose free-floating robots representing Spacecraft in the newly built Controls and Automation Laboratory (CAL) at the ATC. The CAL lab features a 12' x 24' granite air-bearing table and an overhead simulated starfield. Among the technologies needed for the concept demo were mating interfaces allowing the spacecraft to dock and deployable structures allowing for adjustable separation between spacecraft after a rigid connection had been established. The decision to use a nonmetallic deployable boom for this purpose was driven by the MRHE concept demo requirements reproduced in Table 1.

Rehnmark, Fredrik↗

Heisenberg algebra, umbral calculus and orthogonal polynomials

Umbral calculus can be viewed as an abstract theory of the Heisenberg commutation relation [P,M]=1. In ordinary quantum mechanics, P is the derivative and M the coordinate operator. Here, we shall realize P as a second order differential operator and M as a first order integral one. We show that this makes it possible to solve large classes of differential and integrodifferential equations and to introduce new classes of orthogonal polynomials, related to Laguerre polynomials. These polynomials are particularly well suited for describing the so-called flatenned beams in laser theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preliminary design study of a lateral-directional control system using thrust vectoring

A preliminary design of a lateral-directional control system for a fighter airplane capable of controlled operation at extreme angles of attack is developed. The subject airplane is representative of a modern twin-engine high-performance jet fighter, is equipped with ailerons, rudder, and independent horizontal-tail surfaces. Idealized bidirectional thrust-vectoring engine nozzles are appended to the mathematic model of the airplane to provide additional control moments. Optimal schedules for lateral and directional pseudo control variables are calculated. Use of pseudo controls results in coordinated operation of the aerodynamic and thrust-vectoring controls with minimum coupling between the lateral and directional airplane dynamics. Linear quadratic regulator designs are used to specify a preliminary flight control system to improve the stability and response characteristics of the airplane. Simulated responses to step pilot control inputs are stable and well behaved. For lateral stick deflections, peak stability axis roll rates are between 1.25 and 1.60 rad/sec over an angle-of-attack range of 10 deg to 70 deg. For rudder pedal deflections, the roll rates accompanying the sideslip responses can be arrested by small lateral stick motions.

Lallman, F. J.↗

Coupled Heat Power Operation of Smart Buildings via Modular Pumped Hydro Storage

In the United States, building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings’ energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low-grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high-efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground level. This unique design eliminates the geographical limitation associated with the existing state-of-the-art energy storage technologies. It is easy to be scaled for building level, community level, and grid level applications. By using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g., from thermal storage, combined cooling, heat and power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Here, several groups of comparison experiments have been conducted, and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bridging Control and Deployment: A Cross-Layer Analysis of Scalable Building Cluster Control

Building cluster control has emerged as a promising approach for enabling flexible and coordinated operation of distributed building systems, yet its transition from pilot demonstrations to routine grid-interactive operation remains limited. This paper argues that this gap cannot be explained by control algorithms alone. Instead, it arises from interacting barriers in communication infrastructure, data and semantic interoperability, uncertainty management, stakeholder participation, market design, and policy support. Accordingly, the paper reviews both technical and non-technical barriers to building cluster control. Technical challenges include heterogeneous devices and protocols, communication latency and reliability, distributed decision-making, and uncertainty propagation across aggregated loads. Non-technical barriers include user participation, stakeholder coordination, incentive allocation, and data governance. Existing solution approaches are synthesized, including semantic interoperability frameworks, edge and hierarchical communication architectures, distributed and transactive control strategies, uncertainty-aware optimization, policy mechanisms, and market reforms. Based on this analysis, two research directions are identified: testing infrastructures that can evaluate control performance under realistic multi-building conditions, and abstraction methods that allow building clusters to interact with other energy sectors through standardized flexibility representations. Overall, the paper provides a structured review of how building cluster control can move from isolated demonstrations toward reproducible, market-compatible, and grid-relevant implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Provider of Services for Urban Air Mobility (PSU) Prototype Simulation (X5) Final Report

Urban Air Mobility (UAM) is a new air transportation service concept to carry passengers or cargo in metropolitan areas, leveraged by innovative aircraft and air traffic automation technologies. NASA has conducted a series of simulations, called the X-series simulation, to evaluate the UAM concept of operations and support the development of airspace procedures and services for UAM operations. The simulation called “X5” was conducted in 2023 to test a Provider of Services for UAM (PSU) prototype developed by NASA for UAM flight planning, strategic conflict management support, and data exchange between UAM operators. In this simulation, two strategic conflict management capabilities, Demand-Capacity Balancing and Sequencing and Scheduling, were further investigated. This document describes the UAM system architecture modeled, the X5 simulation environment to be executed (e.g., traffic scenario and UAM airspace construct), and the strategic conflict management processes developed and evaluated in this study. Then, the simulation results are provided using several system performance metrics, such as the number of operations planned and activated, demand-capacity imbalances detected and resolved, and pre-departure delays. Based on these metrics, the test findings and lessons learned from this simulation are discussed. NASA developed a PSU prototype as part of a reference implementation of UAM system architecture and evolved strategic conflict management capabilities for UAM operations from the previous collaborative simulations with industry partners. Below is the summary of the achievements: - Aligned NASA’s UAM reference architecture with the FAA’s UAM ConOps notional architecture - Extended UAM airspace management capabilities to include 1) Demand-Capacity Balancing (DCB) to ensure operators coordinate planned usage of shared vertiports, and 2) Sequencing and Scheduling (S&S) at UAM corridor entry and exit points to help facilitate an orderly flow of traffic - Defined the PSU information exchange APIs and requirements towards informing industry standards - Developed and tested a NASA PSU prototype as reference implementation to validate the requirements and APIs - Developed a prototype service connecting NASA’s PSU and the FAA system for testing future PSU-ATM interface requirements - Tested NASA-developed assumptions for UAM operations such as airspace design, procedures, vehicle performance, and strategic conflict management methods to inform future Cooperative Operating Practices (COPs) development with industry - Evaluated system performance metrics such as number of simultaneous operations and ground delays that can help define system-level requirements. The simulation results showed that the UAM traffic demand could be managed to minimize the needs of tactical separation provision with ground delays assigned by DCB and S&S. These accomplishments and the lessons learned from the PSU Prototype X5 simulation activities will be valuable inputs for the Air Mobility Pathfinders (AMP) project, which is NASA’s new project to create and evaluate a reference architecture for safe, secure, and scalable UAM operations.

Simulation↗

Community Coordinated Modeling Center Support of Operations: Real-Time Simulations and V & V.

In support of Operations Community Coordinated Modeling Center (CCMC) performing validation and verification of space weather models. To identify suitable metrics the CCMC focus on parameters most useful to operations that CCMC resident models can provide. The real time simulations carried out at CCMC are an essential tool to test model performance and stability by using input conditions that may occur in nature at any time. Since 2001, the magnetospheric MHD model BATSRUS has been run in real time using ACE real time data. CCMC staff developed an experimental real-time system that controls uploading of the real-time ACE data, monitors continuous model execution, initiates automatic recovery procedure in case of data gaps or hardware failures, synchronizes BATSRUS and FRC runs, and periodically runs IDL based visualization software.

Kuznetsova, M.↗

Groundwater Remediation in a Flood plain Aquifer at Shiprock, New Mexico - 16097

The Shiprock, New Mexico, Disposal Site is the location of a former uranium and vanadium ore-processing mill that operated from 1954 to 1968. During milling years, tailings leachate and other mill-related liquids migrated into underlying sediments, resulting in the contamination of groundwater beneath the river terrace containing the mill and a nearby flood plain alluvial aquifer adjacent to the San Juan River. The US DOE Office of Legacy Management manages the site and is implementing the current groundwater remedy for the flood plain area, consisting of natural flushing supplemented by extraction of alluvial groundwater to accelerate reduction in contaminant concentrations. The alluvial aquifer contains elevated concentrations of sulfate, uranium, and nitrate derived largely from the historical eastward migration of groundwater through terrace alluvium and underlying bedrock to the flood plain. The bedrock formation beneath the entire Shiprock site is Mancos shale, which forms an escarpment that separates the terrace from the flood plain. Contamination in the flood plain alluvial aquifer is influenced by a dynamic flow system that changes seasonally and from year to year. Simulations with a flood plain flow model based on monitored groundwater levels and coincident river-surface elevations show that background groundwater flow, unaffected by remediation pumping, is characterized by distinct hydraulic conditions for three separate periods each year. During months of low river flow in winter and early spring, river losses to the aquifer create a large hypo-rheic zone in the south half of the flood plain. Simultaneously, recharge of continually flowing surface water emptying onto the north half of the flood plain from Bob Lee Wash creates divergent, radial flow from the wash outlet and diverts northwestward-migrating contaminant plumes to the northeast where they discharge to the river. Subsequent bank storage processes in May and June from high snow melt runoff change background flow directions, increasing the spread of contamination in the alluvium. From mid-summer through fall, river flows are typically similar in value to those observed prior to the onset of snow melt, but groundwater elevations in the aquifer are noticeably lower than water levels observed in winter and early spring and may induce river losses to the aquifer. Several different contaminant sources have impacted the alluvial aquifer. Much of the contamination originated as tailings leachate and raffinate wastewater that infiltrated the terrace subsurface and eventually reached the flood plain at the escarpment. Additional sources of contamination in the aquifer included discharge of mill effluent to Bob Lee Wash and a pond at the base of the escarpment, and aqueous mobilization of solid-phase contamination in the form of windblown deposits and contaminants adsorbed to alluvial sediments. The degree to which remnant, secondary-source processes, such as leaching of solid-phase deposits and discharge of terrace groundwater across the escarpment, contribute to existing contaminant plumes is uncertain. The flood plain remediation system consists of two groundwater extraction wells, pumping from two horizontal wells placed in trenches near the base of the escarpment, a sump collecting discharges from seeps in the escarpment wall, and discharge of collected water to an evaporation pond on the terrace. Flow-model simulations indicate that most contaminated areas are captured by remediation pumping, resulting in several zones of freshwater between the river and the escarpment. Despite the highly transient nature of groundwater flow beneath the flood plain and the varied contaminant sources, initiation of remediation pumping in 2003 and coordinated operation of the system's various components have successfully removed large amounts of contaminant mass and helped prevent discharge of contaminated groundwater to the river. The percentage reductions of dissolved sulfate, uranium, and nitrate mass in the aquifer estimated for the first 9 years of remediation range from 40% to 72%. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transactive control of fast-acting demand response based on thermostatic loads in real-time retail electricity markets

Coordinated operation of distributed thermostatic loads such as heat pumps and air conditioners can reduce energy costs and prevents grid congestion, while maintaining room temperatures in the comfort range set by consumers. This paper furthers efforts towards enabling thermostatically controlled loads (TCLs) to participate in real-time retail electricity markets under a transactive control paradigm. An agent-based approach is used to develop an effective and low complexity demand response control scheme for TCLs. The proposed scheme adjusts aggregated thermostatic loads according to real-time grid conditions under both heating and cooling modes. Here, a case study is presented showing the method reduces consumer electricity costs by over 10% compared to uncoordinated operation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Getting lost tracking the carbon footprint of hydropower

In the transition to low-carbon electricity, well-quantified estimates of carbon dynamics are needed to ensure that emissions reduction targets are achieved. Here we review the state of the science on carbon accounting for hydropower reservoirs and identify limitations and future solutions. Nearly all research on reservoir greenhouse-gas (GHG) emissions has focused on individual reservoirs in isolation without considering their position in a freshwater network draining organic matter from upstream watersheds or the coordinated operation of reservoir cascades. Second, carbon inventories have extrapolated from a small, non-probabilistic sample of highly variable measurements of GHG emissions to unsampled reservoirs. A stronger statistical foundation is needed to estimate a global inventory and its uncertainty. Third, attribution to hydropower is based on ranks assigned to reservoir purpose. Instead, the physical influence of hydropower on carbon dynamics could be directly measured. Fourth, current carbon-accounting practices neglect time. A time-varying approach would quantify variation in emissions for electricity portfolios from changes in the fuel mix at different times and account for ancillary services, i.e., the ability to support the grid when variable renewables are not available without using natural gas. Reservoirs also sequester a significant portion of inflowing carbon in sediments and slow the carbon cycle by delaying the return of carbon to the atmosphere for decades to centuries. Together, these refinements would help to illuminate pathways toward meeting energy demand with the longest-possible delay in returning carbon to the atmosphere and without adding ancient sources to the pool of carbon cycling through aquatic ecosystems.

13 HYDRO ENERGY↗

Using microgrids to enhance energy security and resilience

Although microgrids are now widely studied, challenges still exist. A reliable control architecture needs to be developed to coordinate different devices. Advanced forecasting and demand response management approaches should be implemented to cope with the intermittence of renewable generation. Furthermore, interconnection issues should be further studied to eliminate the influence of microgrid integration and achieve coordinated operation throughout the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stochastic assessment of distributed generation hosting capacity and energy efficiency in active distribution networks

Active network management (ANM) aims to increase the capacity of variable distributed generation (DG), which can be connected to existing distribution networks. In this study, it is proposed to simultaneously consider the efficient use of energy resources when high shares of DG are procured through the ANM approach. To that end, a multi-period and multiobjective optimisation algorithm, based on the linearised optimal power flow, is formulated. The algorithm seeks to maximise the installed capacity of DG while minimising the energy losses and consumption of voltage-dependent loads. The objectives are optimised considering the coordinated operation of voltage regulators and on-load tap changers, and the management of DG generation curtailment and reactive power compensation from DG. Additionally, the effects of load and generation uncertainties are addressed through a two-stage stochastic programming formulation of the multiobjective problem. The result is a set of non-inferior solutions, which allows exploring the degree of conflict among the objectives. The proposed approach was tested on two IEEE test feeders and the solutions show a significant improvement in the system's energy efficiency with a low impact on the amount of connected DG.

Quijano, Darwin Alexis↗

Presentation layer of CMS Online Monitoring System

The Compact Muon Solenoid (CMS) is one of the experiments at the CERN Large Hadron Collider (LHC). The CMS Online Monitoring system (OMS) is an upgrade and successor to the CMS Web-Based Monitoring (WBM)system, which is an essential tool for shift crew members, detector subsystem experts, operations coordinators, and those performing physics analyses. The CMS OMS is divided into aggregation and presentation layers. Communication between layers uses RESTful JSON:API compliant requests. The aggregation layer is responsible for collecting data from heterogeneous sources, storage of transformed and pre-calculated (aggregated) values and exposure of data via the RESTful API. The presentation layer displays detector information via a modern, user-friendly and customizable web interface. The CMS OMS user interface is composed of a set of cutting-edge software frameworks and tools to display non-event data to any authenticated CMS user worldwide. The web interface tree-like component structure comprises (top-down): workspaces, folders, pages, controllers and portlets. A clear hierarchy gives the required flexibility and control for content organization. Each bottom element instantiates a portlet and is a reusable component that displays a single aspect of data, like a table, a plot, an article, etc. Pages consist of multiple different portlets and can be customized at runtime by using a drag-and-drop technique. This is how a single page can easily include information from multiple online sources. Different pages give access to a summary of the current status of the experiment, as well as convenient access to historical data. This paper describes the CMS OMS architecture, core concepts and technologies of the presentation layer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗