Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Validation of MODIS Aerosol Optical Depth Retrievals over a Tropical Urban Site, Pune, India

In the present paper, MODIS (Terra and Aqua; level 2, collection 5) derived aerosoloptical depths (AODs) are compared with the ground-based measurements obtained from AERONET (level 2.0) and Microtops - II sun-photometer over a tropical urban station, Pune (18 deg 32'N; 73 deg 49'E, 559 m amsl). This is the first ever systematic validation of the MODIS aerosol products over Pune. Analysis of the data indicates that the Terra and Aqua MODIS AOD retrievals at 550 nm have good correlations with the AERONET and Microtops - II sun-photometer AOD measurements. During winter the linear regression correlation coefficients for MODIS products against AERONET measurements are 0.79 for Terra and 0.62 for Aqua; however for premonsoon, the corresponding coefficients are 0.78 and 0.74. Similarly, the linear regression correlation coefficients for Microtops measurements against MODIS products are 0.72 and 0.93 for Terra and Aqua data respectively during winter and are 0.78 and 0.75 during pre-monsoon. On yearly basis in 2008-2009, correlation coefficients for MODIS products against AERONET measurements are 0.80 and 0.78 for Terra and Aqua respectively while the corresponding coefficients are 0.70 and 0.73 during 2009-2010. The regressed intercepts with MODIS vs. AERONET are 0.09 for Terra and 0.05 for Aqua during winter whereas their values are 0.04 and 0.07 during pre-monsoon. However, MODIS AODs are found to underestimate during winter and overestimate during pre-monsoon with respect to AERONET and Microtops measurements having slopes 0.63 (Terra) and 0.74 (Aqua) during winter and 0.97 (Terra) and 0.94 (Aqua) during pre-monsoon. Wavelength dependency of Single Scattering Albedo (SSA) shows presence of absorbing and scattering aerosol particles. For winter, SSA decreases with wavelength with the values 0.86 +/- 0.03 at 440 nm and 0.82 +/- 0.04 at 1020nm. In pre-monsoon, it increases with wavelength (SSA is 0.87 +/- 0.02 at 440nm; and 0.88 +/-0.04 at 1020 nm).

More, Sanjay↗

Prospective Study Validating Inter- and Intraobserver Variability of Tissue Compliance Meter in Breast Tissue of Healthy Volunteers: Potential Implications for Patients With Radiation-Induced Fibrosis of the Breast

Purpose: Accurate detection of radiation-induced fibrosis (RIF) is crucial in management of breast cancer survivors. Tissue compliance meter (TCM) has been validated in musculature. We validate TCM in healthy breast tissue with respect to interobserver and intraobserver variability before applying it in RIF. Methods and Materials: Three medical professionals obtained three consecutive TCM measurements in each of the four quadrants of the right and left breasts of 40 women with no breast disease or surgical intervention. The intraclass correlation coefficient (ICC) assessed interobserver variability. The paired t test and Pearson correlation coefficient (r) were used to assess intraobserver variability within each rater. Results: The median age was 45 years (range, 24-68 years). The median bra size was 35C (range, 32A-40DD). Of the participants, 27 were white (67%), 4 black (10%), 5 Asian (13%), and 4 Hispanic (10%). ICCs indicated excellent interrater reliability (low interobserver variability) among the three raters, by breast and quadrant (all ICC {>=}0.99). The paired t test and Pearson correlation coefficient both indicated low intraobserver variability within each rater (right vs. left breast), stratified by quadrant (all r{>=} 0.94, p < 0.0001). Conclusions: The interobserver and intraobserver variability is small using TCM in healthy mammary tissue. We are now embarking on a prospective study using TCM in women with breast cancer at risk of developing RIF that may guide early detection, timely therapeutic intervention, and assessment of success of therapy for RIF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Weak data do not make a free lunch, only a cheap meal

Refinement and analysis of four structures with various data resolution cutoffs suggests that at present there are no reliable criteria for judging the diffraction data resolution limit and the condition I/σ(I) = 2.0 is reasonable. However, extending the limit by about 0.2 Å beyond the resolution defined by this threshold does not deteriorate the quality of refined structures and in some cases may be beneficial. Four data sets were processed at resolutions significantly exceeding the criteria traditionally used for estimating the diffraction data resolution limit. The analysis of these data and the corresponding model-quality indicators suggests that the criteria of resolution limits widely adopted in the past may be somewhat conservative. Various parameters, such as R{sub merge} and I/σ(I), optical resolution and the correlation coefficients CC{sub 1/2} and CC*, can be used for judging the internal data quality, whereas the reliability factors R and R{sub free} as well as the maximum-likelihood target values and real-space map correlation coefficients can be used to estimate the agreement between the data and the refined model. However, none of these criteria provide a reliable estimate of the data resolution cutoff limit. The analysis suggests that extension of the maximum resolution by about 0.2 Å beyond the currently adopted limit where the I/σ(I) value drops to 2.0 does not degrade the quality of the refined structural models, but may sometimes be advantageous. Such an extension may be particularly beneficial for significantly anisotropic diffraction. Extension of the maximum resolution at the stage of data collection and structure refinement is cheap in terms of the required effort and is definitely more advisable than accepting a too conservative resolution cutoff, which is unfortunately quite frequent among the crystal structures deposited in the Protein Data Bank.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Incorporating microbial dormancy dynamics into soil decomposition models to improve quantification of soil carbon dynamics of northern temperate forests

Abstract Soil carbon dynamics of terrestrial ecosystems play a significant role in the global carbon cycle. Microbial‐based decomposition models have seen much growth recently for quantifying this role, yet dormancy as a common strategy used by microorganisms has not usually been represented and tested in these models against field observations. Here we developed an explicit microbial‐enzyme decomposition model and examined model performance with and without representation of microbial dormancy at six temperate forest sites of different forest types. We then extrapolated the model to global temperate forest ecosystems to investigate biogeochemical controls on soil heterotrophic respiration and microbial dormancy dynamics at different temporal‐spatial scales. The dormancy model consistently produced better match with field‐observed heterotrophic soil CO 2 efflux ( R H ) than the no dormancy model. Our regional modeling results further indicated that models with dormancy were able to produce more realistic magnitude of microbial biomass (<2% of soil organic carbon) and soil R H (7.5 ± 2.4 Pg C yr −1 ). Spatial correlation analysis showed that soil organic carbon content was the dominating factor (correlation coefficient = 0.4–0.6) in the simulated spatial pattern of soil R H with both models. In contrast to strong temporal and local controls of soil temperature and moisture on microbial dormancy, our modeling results showed that soil carbon‐to‐nitrogen ratio (C:N) was a major regulating factor at regional scales (correlation coefficient = −0.43 to −0.58), indicating scale‐dependent biogeochemical controls on microbial dynamics. Our findings suggest that incorporating microbial dormancy could improve the realism of microbial‐based decomposition models and enhance the integration of soil experiments and mechanistically based modeling.

He, Yujie↗

Internal additive noise effects in stochastic resonance using organic field effect transistor

Stochastic resonance phenomenon was observed in organic field effect transistor using poly(3-hexylthiophene), which enhances performance of signal transmission with application of noise. The enhancement of correlation coefficient between the input and output signals was low, and the variation of correlation coefficient was not remarkable with respect to the intensity of external noise, which was due to the existence of internal additive noise following the nonlinear threshold response. In other words, internal additive noise plays a positive role on the capability of approximately constant signal transmission regardless of noise intensity, which can be said “homeostatic” behavior or “noise robustness” against external noise. Furthermore, internal additive noise causes emergence of the stochastic resonance effect even on the threshold unit without internal additive noise on which the correlation coefficient usually decreases monotonically.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Further Progress in Noise Source Identification in High Speed Jets via Causality Principle

To locate noise sources in high-speed jets, the sound pressure fluctuations p/, measured at far field locations, were correlated with each of density p, axial velocity u, radial velocity v, puu and pvv fluctuations measured from various points in fully expanded, unheated plumes of Mach number 0.95, 1.4 and 1.8. The velocity and density fluctuations were measured simultaneously using a recently developed, non-intrusive, point measurement technique based on molecular Rayleigh scattering (Seasholtz, Panda, and Elam, AIAA Paper 2002-0827). The technique uses a continuous wave, narrow line-width laser, Fabry-Perot interferometer and photon counting electronics. The far field sound pressure fluctuations at 30 to the jet axis provided the highest correlation coefficients with all flow variables. The correlation coefficients decreased sharply with increased microphone polar angle, and beyond about 60 all correlation mostly fell below the experimental noise floor. Among all correlations < puu; p/> showed the highest values. Interestingly, , in all respects, were very similar to . The and correlations with 90deg microphone fell below the noise floor. By moving the laser probe at various locations in the jet it was found that the strongest noise source lies downstream of the end of the potential core and extends many diameters beyond. Correlation measurement from the lip shear layer showed a Mach number dependency. While significant correlations were measured in Mach 1.8 jet, values were mostly below the noise floor for subsonic Mach 0.95 jet. Various additional analyses showed that fluctuations from large organized structures mostly contributed to the measured correlation, while that from small scale structures fell below the noise floor.

Panda, J.↗

SU-E-J-120: Comparing 4D CT Computed Ventilation to Lung Function Measured with Hyperpolarized Xenon-129 MRI

Purpose: To correlate ventilation parameters computed from 4D CT to ventilation, profusion, and gas exchange measured with hyperpolarized Xenon-129 MRI for a set of lung cancer patients. Methods: Hyperpolarized Xe-129 MRI lung scans were acquired for lung cancer patients, before and after radiation therapy, measuring ventilation, perfusion, and gas exchange. In the standard clinical workflow, these patients also received 4D CT scans before treatment. Ventilation was computed from 4D CT using deformable image registration (DIR). All phases of the 4D CT scan were registered using a B-spline deformable registration. Ventilation at the voxel level was then computed for each phase based on a Jacobian volume expansion metric, yielding phase sorted ventilation images. Ventilation based upon 4D CT and Xe-129 MRI were co-registered, allowing qualitative visual comparison and qualitative comparison via the Pearson correlation coefficient. Results: Analysis shows a weak correlation between hyperpolarized Xe-129 MRI and 4D CT DIR ventilation, with a Pearson correlation coefficient of 0.17 to 0.22. Further work will refine the DIR parameters to optimize the correlation. The weak correlation could be due to the limitations of 4D CT, registration algorithms, or the Xe-129 MRI imaging. Continued development will refine parameters to optimize correlation. Conclusion: Current analysis yields a minimal correlation between 4D CT DIR and Xe-129 MRI ventilation. Funding provided by the 2014 George Amorino Pilot Grant in Radiation Oncology at the University of Virginia.

60 APPLIED LIFE SCIENCES↗

Sensitivity Analysis of the Bone Fracture Risk Model

Introduction: The probability of bone fracture during and after spaceflight is quantified to aid in mission planning, to determine required astronaut fitness standards and training requirements and to inform countermeasure research and design. Probability is quantified with a probabilistic modeling approach where distributions of model parameter values, instead of single deterministic values, capture the parameter variability within the astronaut population and fracture predictions are probability distributions with a mean value and an associated uncertainty. Because of this uncertainty, the model in its current state cannot discern an effect of countermeasures on fracture probability, for example between use and non-use of bisphosphonates or between spaceflight exercise performed with the Advanced Resistive Exercise Device (ARED) or on devices prior to installation of ARED on the International Space Station. This is thought to be due to the inability to measure key contributors to bone strength, for example, geometry and volumetric distributions of bone mass, with areal bone mineral density (BMD) measurement techniques. To further the applicability of model, we performed a parameter sensitivity study aimed at identifying those parameter uncertainties that most effect the model forecasts in order to determine what areas of the model needed enhancements for reducing uncertainty. Methods: The bone fracture risk model (BFxRM), originally published in (Nelson et al) is a probabilistic model that can assess the risk of astronaut bone fracture. This is accomplished by utilizing biomechanical models to assess the applied loads; utilizing models of spaceflight BMD loss in at-risk skeletal locations; quantifying bone strength through a relationship between areal BMD and bone failure load; and relating fracture risk index (FRI), the ratio of applied load to bone strength, to fracture probability. There are many factors associated with these calculations including environmental factors, factors associated with the fall event, mass and anthropometric values of the astronaut, BMD characteristics, characteristics of the relationship between BMD and bone strength and bone fracture characteristics. The uncertainty in these factors is captured through the use of parameter distributions and the fracture predictions are probability distributions with a mean value and an associated uncertainty. To determine parameter sensitivity, a correlation coefficient is found between the sample set of each model parameter and the calculated fracture probabilities. Each parameters contribution to the variance is found by squaring the correlation coefficients, dividing by the sum of the squared correlation coefficients, and multiplying by 100. Results: Sensitivity analyses of BFxRM simulations of preflight, 0 days post-flight and 365 days post-flight falls onto the hip revealed a subset of the twelve factors within the model which cause the most variation in the fracture predictions. These factors include the spring constant used in the hip biomechanical model, the midpoint FRI parameter within the equation used to convert FRI to fracture probability and preflight BMD values. Future work: Plans are underway to update the BFxRM by incorporating bone strength information from finite element models (FEM) into the bone strength portion of the BFxRM. Also, FEM bone strength information along with fracture outcome data will be incorporated into the FRI to fracture probability.

mathematical models↗

Automated fibroglandular tissue segmentation and volumetric density estimation in breast MRI using an atlas-aided fuzzy C-means method

Purpose: Breast magnetic resonance imaging (MRI) plays an important role in the clinical management of breast cancer. Studies suggest that the relative amount of fibroglandular (i.e., dense) tissue in the breast as quantified in MR images can be predictive of the risk for developing breast cancer, especially for high-risk women. Automated segmentation of the fibroglandular tissue and volumetric density estimation in breast MRI could therefore be useful for breast cancer risk assessment. Methods: In this work the authors develop and validate a fully automated segmentation algorithm, namely, an atlas-aided fuzzy C-means (FCM-Atlas) method, to estimate the volumetric amount of fibroglandular tissue in breast MRI. The FCM-Atlas is a 2D segmentation method working on a slice-by-slice basis. FCM clustering is first applied to the intensity space of each 2D MR slice to produce an initial voxelwise likelihood map of fibroglandular tissue. Then a prior learned fibroglandular tissue likelihood atlas is incorporated to refine the initial FCM likelihood map to achieve enhanced segmentation, from which the absolute volume of the fibroglandular tissue (|FGT|) and the relative amount (i.e., percentage) of the |FGT| relative to the whole breast volume (FGT%) are computed. The authors' method is evaluated by a representative dataset of 60 3D bilateral breast MRI scans (120 breasts) that span the full breast density range of the American College of Radiology Breast Imaging Reporting and Data System. The automated segmentation is compared to manual segmentation obtained by two experienced breast imaging radiologists. Segmentation performance is assessed by linear regression, Pearson's correlation coefficients, Student's pairedt-test, and Dice's similarity coefficients (DSC). Results: The inter-reader correlation is 0.97 for FGT% and 0.95 for |FGT|. When compared to the average of the two readers’ manual segmentation, the proposed FCM-Atlas method achieves a correlation ofr = 0.92 for FGT% and r = 0.93 for |FGT|, and the automated segmentation is not statistically significantly different (p = 0.46 for FGT% and p = 0.55 for |FGT|). The bilateral correlation between left breasts and right breasts for the FGT% is 0.94, 0.92, and 0.95 for reader 1, reader 2, and the FCM-Atlas, respectively; likewise, for the |FGT|, it is 0.92, 0.92, and 0.93, respectively. For the spatial segmentation agreement, the automated algorithm achieves a DSC of 0.69 ± 0.1 when compared to reader 1 and 0.61 ± 0.1 for reader 2, respectively, while the DSC between the two readers’ manual segmentation is 0.67 ± 0.15. Additional robustness analysis shows that the segmentation performance of the authors' method is stable both with respect to selecting different cases and to varying the number of cases needed to construct the prior probability atlas. The authors' results also show that the proposed FCM-Atlas method outperforms the commonly used two-cluster FCM-alone method. The authors' method runs at ∼5 min for each 3D bilateral MR scan (56 slices) for computing the FGT% and |FGT|, compared to ∼55 min needed for manual segmentation for the same purpose. Conclusions: The authors' method achieves robust segmentation and can serve as an efficient tool for processing large clinical datasets for quantifying the fibroglandular tissue content in breast MRI. It holds a great potential to support clinical applications in the future including breast cancer risk assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Statistical Relations among Solid Precipitation, Atmospheric Moisture and Cloud Parameters in the Arctic

Observations collected during cold-season precipitation periods at Utquagvik, Alaska and at the multidisciplinary drifting observatory for the study of Arctic climate (MOSAiC) are used to statistically analyze the relations among the atmospheric water cycle parameters including the columnar supercooled liquid and ice amounts (expressed as liquid-water and ice-water paths, i.e., LWP and IWP), the integrated water vapor (IWV) and the near-surface snowfall rate. Data come from radar and radiometer-based retrievals and from optical precipitation sensors. While the correlation between snowfall rate and LWP is rather weak, correlation coefficients between radar-derived snowfall rate and IWP are high (~0.8), which is explained, in part, by the generally low LWP/IWP ratios during significant precipitation. Correlation coefficients between snowfall rate and IWV are moderate (~0.45). Correlations are generally weaker if snowfall is estimated by optical sensors, which is, in part, due to blowing snow. Correlation coefficients between near-surface temperature and snowfall rates are low (r < 0.3). The results from the Alaska and MOSAiC sites are generally similar. These results are not very sensitive to the amount of time averaging (e.g., 15 min averaging versus daily averages). Observationally based relations among the water cycle parameters are informative about atmospheric moisture conversion processes and can be used for model evaluations.

54 ENVIRONMENTAL SCIENCES↗

A Metric to Quantify Shared Visual Attention in Two-Person Teams

Introduction: Critical tasks in high-risk environments are often performed by teams, the members of which must work together efficiently. In some situations, the team members may have to work together to solve a particular problem, while in others it may be better for them to divide the work into separate tasks that can be completed in parallel. We hypothesize that these two team strategies can be differentiated on the basis of shared visual attention, measured by gaze tracking. 2) Methods: Gaze recordings were obtained for two-person flight crews flying a high-fidelity simulator (Gontar, Hoermann, 2014). Gaze was categorized with respect to 12 areas of interest (AOIs). We used these data to construct time series of 12 dimensional vectors, with each vector component representing one of the AOIs. At each time step, each vector component was set to 0, except for the one corresponding to the currently fixated AOI, which was set to 1. This time series could then be averaged in time, with the averaging window time (t) as a variable parameter. For example, when we average with a t of one minute, each vector component represents the proportion of time that the corresponding AOI was fixated within the corresponding one minute interval. We then computed the Pearson product-moment correlation coefficient between the gaze proportion vectors for each of the two crew members, at each point in time, resulting in a signal representing the time-varying correlation between gaze behaviors. We determined criteria for concluding correlated gaze behavior using two methods: first, a permutation test was applied to the subjects' data. When one crew member's gaze proportion vector is correlated with a random time sample from the other crewmember's data, a distribution of correlation values is obtained that differs markedly from the distribution obtained from temporally aligned samples. In addition to validating that the gaze tracker was functioning reasonably well, this also allows us to compute probabilities of coordinated behavior for each value of the correlation. As an alternative, we also tabulated distributions of correlation coefficients for synthetic data sets, in which the behavior was modeled as a first-order Markov process, and compared correlation distributions for identical processes with those for disparate processes, allowing us to choose criteria and estimate error rates. 3) Discussion: Our method of gaze correlation is able to measure shared visual attention, and can distinguish between activities involving different instruments. We plan to analyze whether pilots strategies of sharing visual attention can predict performance. Possible measurements of performance include expert ratings from instructors, fuel consumption, total task time, and failure rate. While developed for two-person crews, our approach can be applied to larger groups, using intra-class correlation coefficients instead of the Pearson product-moment correlation.

Gontar, Patrick↗

Correlation Between Soil Moisture and Dust Emissions: An Investigation for Global Climate Modeling

This work is using the newly available NASA SMAP soil moisture measurement data to evaluate its impact on the atmospheric dust emissions. Dust is an important component of atmospheric aerosols, which affects both climate and air quality. In this work, we focused on semi-desert regions, where dust emissions show seasonal variations due to soil moisture changes, i.e. in Sahel of Africa. We first identified three Aerosol Robotic Network (AERONET) sites in the Sahel (IER_Cinzana, Banizoumbou, and Zinder_Airport). We then utilized measurements of aerosol optical depth (AOD), fine mode fraction, size distribution, and single-scattering albedo and its wave-length dependence to select dust plumes from the available measurements We matched the latitude and longitude of the AERONET station to the corresponding SMAP data cell in the years 2015 and 2016, and calculated their correlation coefficient. Additionally, we looked at the correlation coefficient with a three-day and a five-day shift to check the impact of soil moisture on dust plumes with some time delay. Due to the arid nature of Banizoumbou and Zinder_Airport, no correlation was found to exist between local soil moisture and dust aerosol load. While IER_Cinzana had soil moisture levels above the satellite threshold of 0.02cm3/cm3, R-value approaching zero indicated no presence of a correlation. On the other hand, Ilorin demonstrated a significant negative correlation between aerosol optical depth and soil moisture. When isolating the analysis to Ilorin's dry season, a negative correlation of -0.593 was the largest dust-isolated R-value recorded, suggesting that soil moisture is driven the dust emission in this semi-desert region during transitional season.

climate↗

Detection of Unexpected High Correlations between Balance Calibration Loads and Load Residuals

An algorithm was developed for the assessment of strain-gage balance calibration data that makes it possible to systematically investigate potential sources of unexpected high correlations between calibration load residuals and applied calibration loads. The algorithm investigates correlations on a load series by load series basis. The linear correlation coefficient is used to quantify the correlations. It is computed for all possible pairs of calibration load residuals and applied calibration loads that can be constructed for the given balance calibration data set. An unexpected high correlation between a load residual and a load is detected if three conditions are met: (i) the absolute value of the correlation coefficient of a residual/load pair exceeds 0.95; (ii) the maximum of the absolute values of the residuals of a load series exceeds 0.25 % of the load capacity; (iii) the load component of the load series is intentionally applied. Data from a baseline calibration of a six-component force balance is used to illustrate the application of the detection algorithm to a real-world data set. This analysis also showed that the detection algorithm can identify load alignment errors as long as repeat load series are contained in the balance calibration data set that do not suffer from load alignment problems.

strain-gage balance↗

SU-D-207B-01: Radiomics Feature Reproducibility From Repeat CT Scans of Patients with Rectal Cancer

Purpose: To evaluate the reproducibility of radiomics features by repeating computed tomographic (CT) scans in rectal cancer. To choose stable radiomics features for rectal cancer. Methods: 40 rectal cancer patients were enrolled in this study, each of whom underwent two CT scans within average 8.7 days (5 days to 17 days), before any treatment was delivered. The rectal gross tumor volume (GTV) was distinguished and segmented by an experienced oncologist in both CTs. Totally, more than 2000 radiomics features were defined in this study, which were divided into four groups (I: GLCM, II: GLRLM III: Wavelet GLCM and IV: Wavelet GLRLM). For each group, five types of features were extracted (Max slice: features from the largest slice of target images, Max value: features from all slices of target images and choose the maximum value, Min value: minimum value of features for all slices, Average value: average value of features for all slices, Matrix sum: all slices of target images translate into GLCM and GLRLM matrices and superpose all matrices, then extract features from the superposed matrix). Meanwhile a LOG (Laplace of Gauss) filter with different parameters was applied to these images. Concordance correlation coefficients (CCC) and inter-class correlation coefficients (ICC) were calculated to assess the reproducibility. Results: 403 radiomics features were extracted from each type of patients’ medical images. Features of average type are the most reproducible. Different filters have little effect for radiomics features. For the average type features, 253 out of 403 features (62.8%) showed high reproducibility (ICC≥0.8), 133 out of 403 features (33.0%) showed medium reproducibility (0.8≥ICC≥0.5) and 17 out of 403 features (4.2%) showed low reproducibility (ICC≥0.5). Conclusion: The average type radiomics features are the most stable features in rectal cancer. Further analysis of these features of rectal cancer can be warranted for treatment monitoring and prognosis prediction.

60 APPLIED LIFE SCIENCES↗

SU-F-R-33: Can CT and CBCT Be Used Simultaneously for Radiomics Analysis

Purpose: To investigate whether CBCT and CT can be used in radiomics analysis simultaneously. To establish a batch correction method for radiomics in two similar image modalities. Methods: Four sites including rectum, bladder, femoral head and lung were considered as region of interest (ROI) in this study. For each site, 10 treatment planning CT images were collected. And 10 CBCT images which came from same site of same patient were acquired at first radiotherapy fraction. 253 radiomics features, which were selected by our test-retest study at rectum cancer CT (ICC>0.8), were calculated for both CBCT and CT images in MATLAB. Simple scaling (z-score) and nonlinear correction methods were applied to the CBCT radiomics features. The Pearson Correlation Coefficient was calculated to analyze the correlation between radiomics features of CT and CBCT images before and after correction. Cluster analysis of mixed data (for each site, 5 CT and 5 CBCT data are randomly selected) was implemented to validate the feasibility to merge radiomics data from CBCT and CT. The consistency of clustering result and site grouping was verified by a chi-square test for different datasets respectively. Results: For simple scaling, 234 of the 253 features have correlation coefficient ρ>0.8 among which 154 features haveρ>0.9 . For radiomics data after nonlinear correction, 240 of the 253 features have ρ>0.8 among which 220 features have ρ>0.9. Cluster analysis of mixed data shows that data of four sites was almost precisely separated for simple scaling(p=1.29 * 10{sup −7}, χ{sup 2} test) and nonlinear correction (p=5.98 * 10{sup −7}, χ{sup 2} test), which is similar to the cluster result of CT data (p=4.52 * 10{sup −8}, χ{sup 2} test). Conclusion: Radiomics data from CBCT can be merged with those from CT by simple scaling or nonlinear correction for radiomics analysis.

60 APPLIED LIFE SCIENCES↗

Comparison of ISEE-1 and -3 interplanetary magnetic field observations

Three hourly correlation coefficients and the lag at maximum correlation are computed using one minute averages of ISEE-1 and -3 magnetometer data during the period in which ISEE-3 moved from the earth to its halo orbit around the libration point. The maximum correlation coefficients are highly variable ranging from close to zero to almost unity. The lags, while on the average approximating the expected corotation delay, have very large departures from this value. These results suggest that the normals to the planes separating fields of differing orientation often make large angles to the ecliptic plane and/or that the interplanetary magnetic field has a significant amount of bending on a scale length the order of 200 earth radii. Furthermore, there often appears to be a significant amount of propagating structure in the IMF. Thus, ISEE-3 magnetic field measurements should be used with caution if precise timing of arrival at the earth or precise directions of the field upon arrival are important.

Russell, C. T.↗

Assessing CryoSat-2 Antarctic Snow Freeboard Retrievals Using Data From ICESat-2

NASA's Ice, Cloud, and land Elevation Satellite-2 (ICESat-2) laser altimeter launched in Fall 2018, providing an invaluable addition to the polar altimetry record generated by ESA's CryoSat-2 radar altimeter. The simultaneous operation of these two satellite altimeters enables unique comparison studies of sea ice altimetry, utilizing the different frequencies and profiling strategies of the two instruments. Here, we use freeboard data from ICESat-2 to assess Antarctic snow freeboard retrievals from CryoSat-2. We first discuss updates made to a previously published CryoSat-2 retrieval process and show how this Version 2 algorithm improves upon the original method by comparing the new retrievals to ICESat-2 in specific along-track profiles as well as on the basin-scale. In two near-coincident along-track profiles, we find mean snow freeboard differences (standard deviations of differences) of 0.3 (9.3) and 7.6 cm (9.6 cm) with 25 km binned correlation coefficients of 0.77 and 0.89. Monthly mean freeboard differences range between −2.9 (10.8) and 6.6 cm (16.8 cm) basin wide, with the largest differences typically occurring in Austral fall months that is hypothesized to be related to new ice growth and the use of static snow backscatter coefficients in the retrieval. Monthly mean correlation coefficients range between 0.57 and 0.80. While coincident data show good agreement between the two sensors, they highlight issues related to geometric and frequency sampling differences that can impact the freeboard distributions.

S W Fons↗

Phase identification using statistical analysis

A device includes at least one processor configured to determine, based on (i) a first plurality of time-varying electrical measurements corresponding to a feeder head of a power distribution network having a plurality of phases and (ii) a second plurality of time-varying electrical measurements corresponding to a node in the power distribution network, and using statistical analysis, a predicted phase, from the plurality of phases, that corresponds to the node. The processor may be configured to use ranked correlation coefficients (such as the Kendall rank correlation coefficient) to determine the predicted phase and may use principle component analysis. The processor is also configured to cause at least one device of the power distribution network to modify operation based at least on part on the predicted phase.

Veda, Santosh Sambamoorthy↗