Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Uncertainty Quantification Techniques of SCALE/TSUNAMI

The Standardized Computer Analysis for Licensing Evaluation (SCALE) code system developed at Oak Ridge National Laboratory (ORNL) includes Tools for Sensitivity and Uncertainty Analysis Methodology Implementation (TSUNAMI). The TSUNAMI code suite can quantify the predicted change in system responses, such as k eff , reactivity differences, or ratios of fluxes or reaction rates, due to changes in the energy-dependent, nuclide-reaction-specific cross-section data. Where uncertainties in the neutron cross-section data are available, the sensitivity of the system to the cross-section data can be applied to propagate the uncertainties in the cross-section data to an uncertainty in the system response. Uncertainty quantification is useful for identifying potential sources of computational biases and highlighting parameters important to code validation. Traditional validation techniques often examine one or more average physical parameters to characterize a system and identify applicable benchmark experiments. However, with TSUNAMI correlation coefficients are developed by propagating the uncertainties in neutron cross-section data to uncertainties in the computed responses for experiments and safety applications through sensitivity coefficients. The bias in the experiments, as a function of their correlation coefficient with the intended application, is extrapolated to predict the bias and bias uncertainty in the application through trending analysis or generalized linear least squares techniques, often referred to as 'data adjustment.' Even with advanced tools to identify benchmark experiments, analysts occasionally find that the application models include some feature or material for which adequately similar benchmark experiments do not exist to support validation. For example, a criticality safety analyst may want to take credit for the presence of fission products in spent nuclear fuel. In such cases, analysts sometimes rely on 'expert judgment' to select an additional administrative margin to account for gap in the validation data or to conclude that the impact on the calculated bias and bias uncertainty is negligible. As a result of advances in computer programs and the evolution of cross-section covariance data, analysts can use the sensitivity and uncertainty analysis tools in the TSUNAMI codes to estimate the potential impact on the application-specific bias and bias uncertainty resulting from nuclides not represented in available benchmark experiments. This paper presents the application of methods described in a companion paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-J-48: Development of An Abdominal Compression Device for Respiratory Correlated Radiation Therapy

Purpose: The aim of this study is to develop the abdominal compression device which could control pressure level according to the abdominal respiratory motion and evaluate its feasibility. Methods: In this study, we focused on developing the abdominal compression device which could control pressure level at any point of time so the developed device is possible to use a variety of purpose (gating technique or respiratory training system) while maintaining the merit of the existing commercial device. The compression device (air pad form) was designed to be able to compress the front and side of abdomen and the pressure level of the abdomen is controlled by air flow. Pressure level of abdomen (air flow) was determined using correlation data between external abdominal motion and respiratory volume signal measured by spirometer. In order to verify the feasibility of the device, it was necessary to confirm the correlation between the abdominal respiratory motion and respiratory volume signal and cooperation with respiratory training system also checked. Results: In the previous study, we could find that the correlation coefficient ratio between diaphragm and respiratory volume signal measured by spirometer was 0.95. In this study, we confirmed the correlation between the respiratory volume signal and the external abdominal motion measured by belt-transducer (correlation coefficient ratio was 0.92) and used the correlated respiratory volume data as an abdominal pressure level. It was possible to control the pressure level with negligible time delay and respiratory volume data based guiding waveforms could be properly inserted into the respiratory training system. Conclusion: Through this feasibility study, we confirmed the correlation between the respiratory volume signal and the external abdominal motion. Also initial assessment of the device and its compatibility with the respiratory training system were verified. Further study on application in respiratory gated therapy and respiratory training system will be investigated. This work was supported by Radiation Technology R and D program (No. 2013M2A2A7043498)and Basic Atomic Energy Research Institute (BAERI)(No. NRF-2009-0078390) through the National Research Foundation of Korea funded by the Ministry of Science, ICT and Future Planning.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effect of Audio Coaching on Correlation of Abdominal Displacement With Lung Tumor Motion

Purpose: To assess the effect of audio coaching on the time-dependent behavior of the correlation between abdominal motion and lung tumor motion and the corresponding lung tumor position mismatches. Methods and Materials: Six patients who had a lung tumor with a motion range >8 mm were enrolled in the present study. Breathing-synchronized fluoroscopy was performed initially without audio coaching, followed by fluoroscopy with recorded audio coaching for multiple days. Two different measurements, anteroposterior abdominal displacement using the real-time positioning management system and superoinferior (SI) lung tumor motion by X-ray fluoroscopy, were performed simultaneously. Their sequential images were recorded using one display system. The lung tumor position was automatically detected with a template matching technique. The relationship between the abdominal and lung tumor motion was analyzed with and without audio coaching. Results: The mean SI tumor displacement was 10.4 mm without audio coaching and increased to 23.0 mm with audio coaching (p < .01). The correlation coefficients ranged from 0.89 to 0.97 with free breathing. Applying audio coaching, the correlation coefficients improved significantly (range, 0.93-0.99; p < .01), and the SI lung tumor position mismatches became larger in 75% of all sessions. Conclusion: Audio coaching served to increase the degree of correlation and make it more reproducible. In addition, the phase shifts between tumor motion and abdominal displacement were improved; however, all patients breathed more deeply, and the SI lung tumor position mismatches became slightly larger with audio coaching than without audio coaching.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Online and noninvasive monitoring of battery health at negative-half cell in all-vanadium redox flow batteries using ultrasound

Hydrogen evolution is one of the major side reactions that is detrimental to the health of all-vanadium redox flow batteries, especially for long-term cycling. Effective, low-cost, and accurate online prediction and detection methods for hydrogen generation are not yet available. In this work, we designed an online, noninvasive ultrasonic probing approach for monitoring the state of charge (SoC), predicting the hydrogen generation, and detecting hydrogen gas bubbles in anolyte solutions. The technique employs a pulse-echo method to measure the sound speed and the acoustic attenuation coefficient of the anolyte solution. Through static offline experiments and online in operando experiments, we have demonstrated that when hydrogen gas is generated in anolyte solutions, large variations are observed in both sound speed and acoustic attenuation coefficient measurements. We found that the variations of acoustic attenuation coefficient are highly correlated (correlation coefficients >0.9) with the gas flow rate. In conclusion, the designed acoustic method can monitor the SoC of anolyte, predict the hydrogen generation, and detect the presence of gas bubbles in an anolyte solution and, thus, provide information about the state of health for operation and management of flow battery systems.

25 ENERGY STORAGE↗

TU-AB-BRA-05: Repeatability of [F-18]-NaF PET Imaging Biomarkers for Bone Lesions: A Multicenter Study

Purpose: Quantifying the repeatability of imaging biomarkers is critical for assessing therapeutic response. While therapeutic efficacy has been traditionally quantified by SUV metrics, imaging texture features have shown potential for use as quantitative biomarkers. In this study we evaluated the repeatability of quantitative {sup 18}F-NaF PET-derived SUV metrics and texture features in bone lesions from patients in a multicenter study. Methods: Twenty-nine metastatic castrate-resistant prostate cancer patients received whole-body test-retest NaF PET/CT scans from one of three harmonized imaging centers. Bone lesions of volume greater than 1.5 cm{sup 3} were identified and automatically segmented using a SUV>15 threshold. From each lesion, 55 NaF PET-derived texture features (including first-order, co-occurrence, grey-level run-length, neighbor gray-level, and neighbor gray-tone difference matrix) were extracted. The test-retest repeatability of each SUV metric and texture feature was assessed with Bland-Altman analysis. Results: A total of 315 bone lesions were evaluated. Of the traditional SUV metrics, the repeatability coefficient (RC) was 12.6 SUV for SUVmax, 2.5 SUV for SUVmean, and 4.3 cm{sup 3} for volume. Their respective intralesion coefficients of variation (COVs) were 12%, 17%, and 6%. Of the texture features, COV was lowest for entropy (0.03%) and highest for kurtosis (105%). Lesion intraclass correlation coefficient (ICC) was lowest for maximum correlation coefficient (ICC=0.848), and highest for entropy (ICC=0.985). Across imaging centers, repeatability of texture features and SUV varied. For example, across imaging centers, COV for SUVmax ranged between 11–23%. Conclusion: Many NaF PET-derived SUV metrics and texture features for bone lesions demonstrated high repeatability, such as SUVmax, entropy, and volume. Several imaging texture features demonstrated poor repeatability, such as SUVtotal and SUVstd. These results can be used to establish response criteria for NaF PET-based treatment response assessment. Prostate Cancer Foundation (PCF)

60 APPLIED LIFE SCIENCES↗

In Search of Optimum Fresh-Cut Raw Material: Using Computer Vision Systems as a Sensory Screening Tool for Browning-Resistant Romaine Lettuce Accessions

The popularity of ready-to-eat (RTE) salads has prompted novel technology to prolong the shelf life of their ingredients. Fresh-cut romaine lettuce is widely used in RTE salads; however, its tendency to quickly discolor continues to be a challenge for the industry. Selecting the ideal lettuce accessions for use in RTE salads is essential to ensure maximum shelf life, and it is critical to have a practical way to assess and compare the quality of multiple lettuce accessions that are being considered for use in fresh-cut applications. Thus, in this work we aimed to determine whether a computer vision system (CVS) composed of image acquisition, processing, and analysis could be effective to detect visual quality differences among 16 accessions of fresh-cut romaine lettuce during postharvest storage. The CVS involved a post-capturing color correction, effective image segmentation, and calculation of a browning index, which was tested as a predictor of quality and shelf life of fresh-cut romaine lettuce. The results demonstrated that machine vision software can be implemented to replace or supplement the scoring of a trained panel and instrumental quality measurements. Overall visual quality, a key sensory parameter that determines food preferences and consumer behavior, was highly correlated with the browning index, with a Pearson correlation coefficient of −0.85. Other important sensory decision parameters were also strongly or moderately correlated with the browning index, with Pearson correlation coefficients of −0.84 for freshness, 0.79 for off odor, and 0.57 for browning. The ranking of the accessions according to quality acceptability from the sensory evaluation produced a similar pattern to those obtained with the CVS. This study revealed that multiple lettuce accessions can be effectively benchmarked for their performance as fresh-cut sources via a CVS-based method. Future opportunities and challenges in using machine vision image processing to predict consumer preferences for RTE salad greens is also discussed.

Agriculture↗

Toward Online Adaptive Hyperthermia Treatment Planning: Correlation Between Measured and Simulated Specific Absorption Rate Changes Caused by Phase Steering in Patients

Purpose: Hyperthermia is the clinical application of heat, in which tumor temperatures are raised to 40°C to 45°C. This proven radiation and chemosensitizer significantly improves clinical outcome for several tumor sites. Earlier studies of the use of pre-treatment planning for hyperthermia showed good qualitative but disappointing quantitative reliability. The purpose of this study was to investigate whether hyperthermia treatment planning (HTP) can be used more reliably for online adaptive treatment planning during locoregional hyperthermia treatments. Methods and Materials: This study included 78 treatment sessions for 15 patients with non-muscle-invasive bladder cancer. At the start of treatments, temperature rise measurements were performed with 3 different antenna settings optimized for each patient, from which the absorbed power (specific absorption rate [SAR]) was derived. HTP was performed based on a computed tomography (CT) scan in treatment position with the bladder catheter in situ. The SAR along the thermocouple tracks was extracted from the simulated SAR distributions. Correlations between measured and simulated (average) SAR values were determined. To evaluate phase steering, correlations between the changes in simulated and measured SAR values averaged over the thermocouple probe were determined for all 3 combinations of antenna settings. Results: For 42% of the individual treatment sessions, the correlation coefficient between measured and simulated SAR profiles was higher than 0.5, whereas 58% showed a weak correlation (R of <0.5). The overall correlation coefficient between measured and simulated average SAR was weak (R=0.31; P<.001). The measured and simulated changes in average SAR after adapting antenna settings correlated much better (R=0.70; P<.001). The ratio between the measured and simulated quotients of maximum and average SARs was 1.03 ± 0.26 (mean ± SD), indicating that HTP can also correctly predict the relative amplitude of SAR peaks. Conclusions: HTP can correctly predict SAR changes after adapting antenna settings during hyperthermia treatments. This allows online adaptive treatment planning, assisting the operator in determining antenna settings resulting in increased tumor temperatures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CORRELATION OF HARD X-RAY AND WHITE LIGHT EMISSION IN SOLAR FLARES

A statistical study of the correlation between hard X-ray and white light emission in solar flares is performed in order to search for a link between flare-accelerated electrons and white light formation. We analyze 43 flares spanning GOES classes M and X using observations from the Reuven Ramaty High Energy Solar Spectroscopic Imager and Helioseismic and Magnetic Imager. We calculate X-ray fluxes at 30 keV and white light fluxes at 6173 Å summed over the hard X-ray flare ribbons with an integration time of 45 s around the peak hard-X ray time. We find a good correlation between hard X-ray fluxes and excess white light fluxes, with a highest correlation coefficient of 0.68 for photons with energy of 30 keV. Assuming the thick target model, a similar correlation is found between the deposited power by flare-accelerated electrons and the white light fluxes. The correlation coefficient is found to be largest for energy deposition by electrons above ∼50 keV. At higher electron energies the correlation decreases gradually while a rapid decrease is seen if the energy provided by low-energy electrons is added. This suggests that flare-accelerated electrons of energy ∼50 keV are the main source for white light production.

79 ASTRONOMY AND ASTROPHYSICS↗

Ensemble‐Based, Large‐Eddy Reconstruction of Wind Turbine Inflow in a Near‐Stationary Atmospheric Boundary Layer Through Generative Artificial Intelligence

ABSTRACT To validate the second‐by‐second dynamics of turbines in field experiments, it is necessary to accurately reconstruct the winds going into the turbine. Current time‐resolved inflow reconstruction techniques estimate wind behavior in unobserved regions using relatively simple spectral‐based models of the atmosphere. Here, we develop a technique for time‐resolved inflow reconstruction that is rooted in a large‐eddy simulation model of the atmosphere. Our “large‐eddy reconstruction” technique blends observations and atmospheric model information through a diffusion model machine learning algorithm, allowing us to generate probabilistic ensembles of reconstructions for a single 10‐min observational period. Our generated inflows can be used directly by aeroelastic codes or as inflow boundary conditions in a large‐eddy simulation. We verify the second‐by‐second reconstruction capability of our technique in three synthetic field campaigns, finding positive Pearson correlation coefficient values () between ground‐truth and reconstructed streamwise velocity, as well as smaller positive correlation coefficient values for unobserved fields (spanwise velocity, vertical velocity, and temperature). We validate our technique in three real‐world case studies by driving large‐eddy simulations with reconstructed inflows and comparing to independent inflow measurements. The reconstructions are visually similar to measurements, follow desired power spectra properties, and track second‐by‐second behavior ().

17 WIND ENERGY↗

Method of predicting the mean lung dose based on a patient's anatomy and dose-volume histograms

The aim of this study was to propose a method to predict the minimum achievable mean lung dose (MLD) and corresponding dosimetric parameters for organs-at-risk (OAR) based on individual patient anatomy. For each patient, the dose for 36 equidistant individual multileaf collimator shaped fields in the treatment planning system (TPS) was calculated. Based on these dose matrices, the MLD for each patient was predicted by the homemade DosePredictor software in which the solution of linear equations was implemented. The software prediction results were validated based on 3D conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) plans previously prepared for 16 patients with stage III non–small-cell lung cancer (NSCLC). For each patient, dosimetric parameters derived from plans and the results calculated by DosePredictor were compared. The MLD, the maximum dose to the spinal cord (D{sub max} {sub cord}) and the mean esophageal dose (MED) were analyzed. There was a strong correlation between the MLD calculated by the DosePredictor and those obtained in treatment plans regardless of the technique used. The correlation coefficient was 0.96 for both 3D-CRT and VMAT techniques. In a similar manner, MED correlations of 0.98 and 0.96 were obtained for 3D-CRT and VMAT plans, respectively. The maximum dose to the spinal cord was not predicted very well. The correlation coefficient was 0.30 and 0.61 for 3D-CRT and VMAT, respectively. The presented method allows us to predict the minimum MLD and corresponding dosimetric parameters to OARs without the necessity of plan preparation. The method can serve as a guide during the treatment planning process, for example, as initial constraints in VMAT optimization. It allows the probability of lung pneumonitis to be predicted.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison between DVH-based doses and ICRU point-based doses to the rectum and the bladder using CT-based high-dose rate brachytherapy to the cervix

Traditionally, doses to the bladder and the rectum were quantified using the bladder and rectal reference points defined by the International Commission on Radiation Units and Measurements (ICRU) in Report No. 38. In this study, we compared the 0.1-, 1.0-, 2.0-cc doses to the bladder and the rectum with the corresponding ICRU point doses using computed tomography (CT)-based planning in the intracavitary brachytherapy of carcinoma of the cervix. CT datasets of 136 consecutive intracavitary brachytherapy insertions between January and May 2015 were analyzed. The bladder and the rectum were contoured on consecutive CT slices as per Groupe Europeen de Curietherapie and the European Socie Ty for Radiotherapy and Oncology recommendations. Dose volume histograms were generated and doses of 0.1, 1.0, and 2.0 cc to the bladder and the rectum were recorded. ICRU bladder and rectal points were identified in the treatment plan. Mean doses of 0.1, 1.0, and 2.0 cc to the bladder was found to be 2.02, 1.57, and 1.35 times the ICRU point dose, respectively. The maximum dose received by the bladder was found to be 5.83 times the average ICRU point dose. Mean doses of 0.1, 1.0, and 2.0 cc to the rectum were found to be 1.12, 0.90, and 0.78 times the ICRU rectal point dose, respectively. The maximum dose received by the rectum was 4.79 times the average ICRU point dose. The Pearson correlation coefficient value (r) was found to be 0.639 for D2cc and ICRU bladder point values. The Pearson correlation coefficient value was found to be 0.752 for D2cc and ICRU rectal point values. Our results show that the ICRU bladder points underestimated the dose to the bladder, which is in agreement with other studies. ICRU rectal point doses were higher than the corresponding D2cc doses. However, there was a good correlation between D2cc and ICRU point doses for both the bladder and the rectum.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced Temperature-Humidity Similarity Caused by Entrainment Processes With Increased Wind Shear

A number of studies already suggested that entrainment of warm/dry air from aloft degrades the similarity between air temperature (T) and specific humidity (q) in the atmospheric surface layer (ASL). Less is known about entrainment of cool/dry air on the ASL T-q similarity. Using eddy covariance measurements over a large inland water surface, enhanced T-q similarity with increased friction velocity (u*) was measured during daytime unstable conditions. Explaining this enhancement is the main goal of this work. Cool/dry air masses originating and advecting from land set the upper boundary condition on a quasi-equilibrated internal boundary layer embedding the warm/moist ASL over water. With increased u*, the entrainment velocity (dhI/dt ∝ u*) increases, thereby enhancing entrainment of cool/dry air originating from land, where t is time and hI is the internal boundary layer depth. By analyzing the scale-dependent (spectral) correlation coefficients, the enhanced T-q similarity with increased u* was shown to originate from spectral correlation coefficients in the middle- to low-frequency ranges (large eddies » z, the distance from the surface). With further increases in u*, similarity between T and q within large eddies was further enhanced and phase differences between T and q was reduced. Quadrant analysis showed large increases in flux and time fractions of downward large cool/dry eddies with increasing u*. These results provide evidence that enhanced entrainment of synchronized, large cool/dry eddies was a primary cause for the increased T-q similarity with increasing u*.

54 ENVIRONMENTAL SCIENCES↗

Algorithm for the direct reconstruction of the dark matter correlation function from weak lensing and galaxy clustering

The clustering of matter on cosmological scales is an essential probe for studying the physical origin and composition of our Universe. To date, most of the direct studies have focused on shear-shear weak lensing correlations, but it is also possible to extract the dark matter clustering by combining galaxy-clustering and galaxy-galaxy-lensing measurements. In order to extract the required information, one must relate the observable galaxy distribution to the underlying dark matter distribution. In this study we develop in detail a method that can constrain the dark matter correlation function from galaxy clustering and galaxy-galaxy-lensing measurements, by focusing on the correlation coefficient between the galaxy and matter overdensity fields. Our goal is to develop an estimator that maximally correlates the two. To generate a mock galaxy catalogue for testing purposes, we use the halo occupation distribution approach applied to a large ensemble of N-body simulations to model preexisting SDSS luminous red galaxy sample observations. Using this mock catalogue, we show that a direct comparison between the excess surface mass density measured by lensing and its corresponding galaxy clustering quantity is not optimal. We develop a new statistic that suppresses the small-scale contributions to these observations and show that this new statistic leads to a cross-correlation coefficient that is within a few percent of unity down to 5h{sup -1} Mpc. Furthermore, the residual incoherence between the galaxy and matter fields can be explained using a theoretical model for scale-dependent galaxy bias, giving us a final estimator that is unbiased to within 1%, so that we can reconstruct the dark matter clustering power spectrum at this accuracy up to k{approx}1h Mpc{sup -1}. We also perform a comprehensive study of other physical effects that can affect the analysis, such as redshift space distortions and differences in radial windows between galaxy clustering and weak lensing observations. We apply the method to a range of cosmological models and explicitly show the viability of our new statistic to distinguish between cosmological models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MODELING THE ALIGNMENT PROFILE OF SATELLITE GALAXIES IN CLUSTERS

Analyzing the halo and galaxy catalogs from the Millennium Simulations at redshifts z = 0, 0.5, 1, we determine the alignment profiles of cluster galaxies by measuring the average alignments between the major axes of the pseudo inertia tensors from all satellites within a cluster's virial radius and from only those satellites within some smaller radius as a function of the top-hat scale difference. The alignment profiles quantify how well the satellite galaxies retain the memory of the external tidal fields after merging into their host clusters and how fast they lose the initial alignment tendency as the cluster's relaxation proceeds. It is found that the alignment profile drops faster at higher redshifts and on smaller mass scales. This result is consistent with the picture that the faster merging of the satellites and earlier onset of the nonlinear effect inside clusters tend to break the preferential alignments of the satellites with the external tidal fields. Modeling the alignment profile of cluster galaxies as a power law of the density correlation coefficient that is independent of the power spectrum normalization ({sigma}{sub 8}) and demonstrating that the density correlation coefficient varies sensitively with the density parameter ({Omega}{sub m}) and neutrino mass fraction (f{sub {nu}}), we suggest that the alignment profile of cluster galaxies might be useful for breaking the {Omega}{sub m}-{sigma}{sub 8} and f{sub {nu}}-{sigma}{sub 8} degeneracies.

79 ASTRONOMY AND ASTROPHYSICS↗

Approximation of ice phenology of Maine lakes using Aqua MODIS surface temperature data

Studies of lake ice phenology have historically relied on limited in situ data. Relatively few observations exist for ice out and fewer still for ice in, both of which are necessary to determine the temporal extent of ice cover. Satellite data provide an opportunity to better document patterns of ice phenology across landscapes and relate them to the climatological drivers behind changing ice phenology. We developed a model, the Cumulative Sum Method (CSM), that uses daytime and nighttime surface temperature observations from the Moderate Resolution Imaging Spectroradiometer (MODIS) sensor on board the Earth-observing Aqua satellite to approximate ice in (the onset of ice cover) and ice out from training datasets of 13 and 58 Maine lakes, respectively, during the 2002/2003 through 2017/2018 ice seasons. Ice in was signaled by reaching a threshold of cumulative negative degrees following the first day of the season below 0°C. Ice out was signaled by reaching a threshold of cumulative positive degrees following the first day of the year above 0°C. The comparison of observed and remotely sensed ice-in dates showed relative agreement with a correlation coefficient of 0.71 and a mean absolute error (MAE) of 9.8 days. Ice-out approximations had a correlation coefficient of 0.67 and an MAE of 8.8 days. Lakes smaller in surface area and nearer the Atlantic coast had the greatest error in approximation. Application of the CSM to 20 additional lakes in Maine produced a comparable ice-out MAE of 8.9 days. Ice-out model performance was weaker for the warmest years; there was a larger MAE of 12.0 days when the model was applied to the years 2019–2023 for the original 58 lakes. The development of this model, which utilizes daily satellite data, demonstrates the promise of remote sensing for quantifying ice phenology over short, temporal scales, and wider geographic regions than can be observed in situ, and allows exploration of the influence of surface temperature patterns on the process and timing of ice in and ice out.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-20: A Correlation Study of 2D and 3D Gamma Passing Rates for Prostate IMRT Plans

Purpose: To investigate the correlation between the two-dimensional gamma passing rate (2D %GP) and three-dimensional gamma passing rate (3D %GP) in prostate IMRT quality assurance. Methods: Eleven prostate IMRT plans were randomly selected from the clinical database and were used to obtain dose distributions in the phantom and patient. Three types of delivery errors (MLC bank sag errors, central MLC errors and monitor unit errors) were intentionally introduced to modify the clinical plans through an in-house Matlab program. This resulted in 187 modified plans. The 2D %GP and 3D %GP were analyzed using different dose-difference and distance-toagreement (1%-1mm, 2%-2mm and 3%-3mm) and 20% dose threshold. The 2D %GP and 3D %GP were then compared not only for the whole region, but also for the PTVs and critical structures using the statistical Pearson’s correlation coefficient (γ). Results: For different delivery errors, the average comparison of 2D %GP and 3D %GP showed different conclusions. The statistical correlation coefficients between 2D %GP and 3D %GP for the whole dose distribution showed that except for 3%/3mm criterion, 2D %GP and 3D %GP of 1%/1mm criterion and 2%/2mm criterion had strong correlations (Pearson’s γ value >0.8). Compared with the whole region, the correlations of 2D %GP and 3D %GP for PTV were better (the γ value for 1%/1mm, 2%/2mm and 3%/3mm criterion was 0.959, 0.931 and 0.855, respectively). However for the rectum, there was no correlation between 2D %GP and 3D %GP. Conclusion: For prostate IMRT, the correlation between 2D %GP and 3D %GP for the PTV is better than that for normal structures. The lower dose-difference and DTA criterion shows less difference between 2D %GP and 3D %GP. Other factors such as the dosimeter characteristics and TPS algorithm bias may also influence the correlation between 2D %GP and 3D %GP.

60 APPLIED LIFE SCIENCES↗

Sensitivities and correlations of critical experiments due to uncertainties of system parameters and nuclear data - 14416

With increasing demand on accuracy of criticality calculations, correlations between benchmark experiments due to system parameter uncertainties become of interest in bias determination. The impact of different interpretations of system parameter uncertainties on the calculation of covariances and correlations of k{sub eff} is discussed in this article. Following the suggestion of the OECD/NEA EGUACSA Benchmark phase IV [1], 21 experiments from the ICSBEP international Handbook of Evaluated Criticality Safety Benchmarks [2] are used for this analysis (LEU-COMP-THERM series 07, exp. 01-04 and 39, exp. 01-17). The experiments share certain assembly and fuel features and were carried out in the same lab. Therefore, correlations in the calculation of k{sub eff} appear. Correlation coefficients between experiments due to nuclear data uncertainties are calculated with TSUNAMI [3] and show high values for most experiments. For the correlation analysis due to system parameter uncertainties mainly two scenarios are considered: In scenario A all uncertain parameters are varied mutually for all fuel rods, representing a systematic deviation of the actual experimental setup from the design value. This analysis is performed for all experiments listed above. In scenario E certain parameters like the outer cladding diameter are varied for each fuel rod individually, representing a random scattering of the varied parameter. Scenarios B, C and D represent intermediate scenarios between A and E, which are discussed shortly. Uncertainty and sensitivity calculations of k{sub eff} on the uncertain experimental parameters based on Monte Carlo sampling are presented and discussed. The calculations were performed with SUnCISTT (Sensitivities and Uncertainties in Criticality Inventory and Source Term Tool [4]) and SCALE 6.1.2 [3]. For the 21 EGUACSA proposed experiments the outer cladding diameter is the leading effect for the uncertainty of k{sub eff} for scenario A. In contrast, for scenario E the impact of the cladding diameter on k{sub eff} cancels out due to rod wise variations leaving the fuel diameter as the leading effect. The correlation analysis based on system parameter uncertainties indicates a significant dependence of the correlation coefficients on the interpretation of the uncertainties. It shows high values for scenario A, if the neutronic features are similar (EALF, H/U). For scenario E the overall correlations are significantly smaller and variations between experiments decrease. The impact of the determined correlations on bias calculations of application cases will be discussed by the authors in the accompanying paper 'Impact of correlated data in validation procedures'. (authors)

42 ENGINEERING↗

Linear Correlation Between Patient Survival and Decreased Percentage of Tumor [{sup 18}F]Fluorodeoxyglucose Uptake for Late-Course Accelerated Hyperfractionated Radiotherapy for Esophageal Cancer

Purpose: The aims of this trial were to study whether a decreased percentage of tumor fluorodeoxyglucose (FDG) uptake (%DeltaSUVmax) correlated with overall survival and local control times for patients with esophageal cancer and which patients would benefit from a late-course accelerated hyperfractionated (LCHF) radiation scheme. Methods and Materials: A total of 50 eligible patients with squamous esophageal cancer received positron-emission tomography examinations three times and were treated with the LCHF radiation scheme, with a dose of 68.4 Gy/41 fractions in 6.5 weeks. A %DeltaSUVmax value was calculated, and patients were stratified as highly radiosensitive (HR), moderately radiosensitive (MR), and low radiosensitivity (LR) according to %DeltaSUVmax values in the conventional fraction (CF) scheme. Then, a linear correlation was calculated between patients' survival time and %DeltaSUVmax. Local control and overall survival rates were compared after stratification. Results: In the MR subgroup, there was no linear correlation between %DeltaSUVmax and the CF and LCHF schemes (correlation coefficient, R < 0.4; p > 0.05). In the other subgroups (HR and LR), %DeltaSUVmax values between the CF and LCHF schemes were correlated. Also, in the HR and LR subgroups, %DeltaSUVmax after radiation correlated with overall survival or local control rates (correlation coefficient, R >0.5, and p < 0.05). Three-year local control rates in the HR, MR, and LR subgroups were 100%, 81.5%, and 0%, respectively (p < 0.001). Also, 3-year overall survival rates were 92.4%, 58.8%, and 0% for HR, MR, and LR subgroups, respectively (p < 0.001). Conclusions: Postradiation %DeltaSUVmax was positively correlated with survival time for patients' with esophageal cancer. Patients who benefited from LCHF schedules were those with a decrease of 30% to 60% in tumor FDG uptake after the completion of CF radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗