Search NASA⌕ Search

SEARCH · Search NASA

Results for “counts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Photon Counting Detector Array Algorithms for Deep Space Optical Communications

For deep-space optical communications systems utilizing an uplink optical beacon, a single-photon-counting detector array on the flight terminal can be used to simultaneously perform uplink tracking and communications as well as accurate downlink pointing at photon-starved (pW/sq. m) power levels. In this paper, we discuss concepts and algorithms for uplink signal acquisition, tracking, and parameter estimation using a photon-counting camera. Statistical models of detector output data and signal processing algorithms are presented, incorporating realistic effects such as Earth background and detector/readout blocking. Analysis and simulation results are validated against measured laboratory data using state-of-the-art commercial photon-counting detector arrays, demonstrating sub-microradian tracking errors under channel conditions representative of deep space optical links.

beacon tracking↗

A Critical Look at Coulomb Counting Approach for State of Charge Estimation in Batteries

In this paper, we consider the problem of state-of-charge estimation for rechargeable batteries. Coulomb counting is a well-known method for estimating the state of charge, and it is regarded as accurate as long as the battery capacity and the beginning state of charge are known. The Coulomb counting approach, on the other hand, is prone to inaccuracies from a variety of sources, and the magnitude of these errors has not been explored in the literature. We formally construct and quantify the state-of-charge estimate error during Coulomb counting due to four types of error sources: (1) current measurement error; (2) current integration approximation error; (3) battery capacity uncertainty; and (4) timing oscillator error/drift. It is demonstrated that the state-of-charge error produced can be either time-cumulative or state-of-charge-proportional. Time-cumulative errors accumulate over time and have the potential to render the state-of-charge estimation utterly invalid in the long term. The proportional errors of the state of charge rise with the accumulated state of charge and reach their worst value within one charge/discharge cycle. The study presents methods for reducing time-cumulative and state-of-charge-proportional mistakes through simulation analysis.

Battery management system↗

Effect of laminae count and manufacturing methods on mechanical properties of thin‐ply woven composites

Abstract Thin‐ply woven composites exhibit exceptional mechanical performance by delaying the onset of damage, making them suitable for high‐performance structural applications. This study outlines the impact of manufacturing techniques (vacuum bagging and hot pressing), ply count, and fiber waviness on the mechanical properties of aromatic thermosetting copolyester/carbon‐fiber (ATSP/CF) composites. The analysis encompasses several different ply counts, evaluating their effects on the in‐plane elastic modulus (0°–90°) and tensile strength. Results demonstrate that reducing the waviness (or crimp) ratio significantly enhances the in‐plane elastic modulus, with improvements up to 188%, highlighting the importance of fiber alignment. Vacuum bagging produced ply thicknesses from 128 to 58 μm for 1–36 plies, with in‐plane elastic moduli from 30.3 to 87.2 GPa, and 4‐ and 8‐ply samples showed approximately 40% higher stiffness than those made by hot pressing. ATSP resin with high thermal stability (up to 400°C) and recyclability was used. Furthermore, this study highlights the microstructural enhancements achieved through vacuum bagging, as revealed by scanning electron and optical microscopy, and micro‐computed tomography imaging. This paper provides insights into damage mitigation and achieving enhanced mechanical properties by controlling fiber waviness using vacuum bagging and higher ply count in thin‐ply ATSP/CF composites. Highlights Crimp ratio reduction enhances elastic in‐plane elastic modulus up to 188%. Vacuum bagging increases modulus over the hot pressing manufacturing method by 40%. Lowering thickness‐per‐ply increases failure strain from 0.8% to 1.2%. Explored the performance of a novel ATSP matrix with high recyclability and thermal stability.

Kushwaha, Shashank [The Grainger College of Engine↗

Calibration of a broadband x-ray crystal spectrometer using a continuum x-ray source and photon-counting detectors

We report measurements of sensitivity of a broadband (≃20–30 keV) x-ray crystal spectrometer using a bremsstrahlung continuum x-ray source and several detectors, including an energy-discriminating photon-counting point detector (Si drift diode, Amptek Inc.), imaging hybrid photon-counting detectors (Eiger2-Si and Eiger2-CdTe, DECTRIS Ltd.), and image plates (SR type). Sensitivity is defined as a ratio of the crystal-reflected energy-position-dispersed spectrum measured by a given detector to the incident non-dispersed spectrum measured using the energy-discriminating point detector. The sensitivity derived from data measured exclusively by the point detector is considered detector-independent and serves as a reference. The sensitivities derived from data collected with the hybrid photon-counting detectors were matched to the reference using a scale factor of 1.05. The image plate-derived sensitivities required a scale factor of 1.16 to match the reference. Furthermore, the resulting mismatch in the shapes of all measured scaled sensitivities in the range of the spectrometer was ≲±10%, while the mismatch between the shapes of the sensitivities corresponding to the Si-based detectors was ≲±2.5%.

Crystal optics↗

Constrained variational optimization of counting-time allocation in sequential scattering measurements: Application to Bonse–Hart USANS

Sequential scattering measurements are often performed under a fixed experimental-time budget, even though the expected count rate varies strongly across the measured coordinate. When the dwell time at each measurement position can be controlled independently, this variation creates a general resource-allocation problem: how should the available time be distributed to minimize the uncertainty of the reconstructed profile? We formulate this problem as a constrained variational optimization for measurements governed by Poisson counting statistics. When each measurement is treated independently, minimizing the averaged squared relative uncertainty yields an inverse-square-root intensity allocation. The formulation is then generalized to include correlations between neighboring measurements and an instrumental resolution operator, leading to an allocation criterion that equalizes the marginal reduction in posterior uncertainty per unit measurement time. Bonse–Hart ultra-small-angle neutron scattering (USANS), in which reciprocal space is sampled sequentially through analyzer-angle stepping, provides an experimentally grounded application. Computational benchmarking shows that the optimized allocation outperforms uniform-time and constant-relative-error strategies, while application to an experimentally measured graphite USANS profile from the Spallation Neutron Source, using Poisson resampling under alternative schedules, demonstrates how counting time should be redistributed toward weak-intensity regions under an identical total duration. The resulting framework applies to sequential scattering and related scanning measurements whenever local dwell times are adjustable and directly determine the measurement uncertainties, and when the relevant correlation and instrumental-response models are available.

Tung, Chi-Huan [ORNL] (ORCID:0000000221972074)↗

Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. Here, we calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

47 OTHER INSTRUMENTATION↗

Radon emanation rate measurements using liquid scintillation counting

This article describes a radon emanation measurement technique using liquid scintillator counting. A model for radon loading and transport is described, along with its calibration. Detector background and blank have been studied and quantified. The Minimal detectable activity has been determined for the counting setup using a toy Monte Carlo simulation. Here, the measurement technique is validated using a butyl rubber sample previously used for cross-calibration between different radon counting facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation and optimization of the advanced signal counting techniques on weldments

The signal counting technique with the Delta ultrasonic method is evaluated and optimized for flaw detection in aluminum welds. A comparison is made between the counting and conventional amplitude-gate methods to detect flaws. No conclusion is drawn on the sensitivity of these two methods to detect flaws when the mismatch at the welds is small (25 mils or less). When the mismatch is 25 mils or more, the signal counting method is more sensitive. Of the 24 welded specimens, 50 flaws were found by X-ray inspection and 59 by the Delta method. On 1/4-inch thick welds, X-ray is equal to or slightly more sensitive than Delta method, but on the 1/2-inch thick welds Delta ultrasonic appears more sensitive in flaw detection.

Yee, B. G. W.↗

White blood cell counting system

The design, fabrication, and tests of a prototype white blood cell counting system for use in the Skylab IMSS are presented. The counting system consists of a sample collection subsystem, sample dilution and fluid containment subsystem, and a cell counter. Preliminary test results show the sample collection and the dilution subsystems are functional and fulfill design goals. Results for the fluid containment subsystem show the handling bags cause counting errors due to: (1) adsorption of cells to the walls of the container, and (2) inadequate cleaning of the plastic bag material before fabrication. It was recommended that another bag material be selected.

Source record↗

Photon counting and Laguerre detection.

In this correspondence maximum-likelihood binary detection theory is applied to an incoherent optical system model employing photodetectors governed by Laguerre counting statistics. It is shown that a maximum-likelihood Laguerre detector corresponds to a count comparison over each signaling interval. Laguerre error probabilities are presented and compared with those for Poisson counting.

Gagliardi, R. M.↗

Architecture and data processing alternatives for the TSE computer. Volume 3: Execution of a parallel counting algorithm using array logic (Tse) devices

A parallel algorithm for counting the number of logic-l elements in a binary array or image developed during preliminary investigation of the Tse concept is described. The counting algorithm is implemented using a basic combinational structure. Modifications which improve the efficiency of the basic structure are also presented. A programmable Tse computer structure is proposed, along with a hardware control unit, Tse instruction set, and software program for execution of the counting algorithm. Finally, a comparison is made between the different structures in terms of their more important characteristics.

Metcalfe, A. G.↗

Photon-counting detector arrays based on microchannel array plates

The recent development of the channel electron multiplier (CEM) and its miniaturization into the microchannel array plate (MCP) offers the possibility of fully combining the advantages of the photographic and photoelectric detection systems. The MCP has an image-intensifying capability and the potential of being developed to yield signal outputs superior to those of conventional photomultipliers. In particular, the MCP has a photon-counting capability with a negligible dark-count rate. Furthermore, the MCP can operate stably and efficiently at extreme-ultraviolet and soft X-ray wavelengths in a windowless configuration or can be integrated with a photo-cathode in a sealed tube for use at ultraviolet and visible wavelengths. The operation of one- and two-dimensional photon-counting detector arrays based on the MCP at extreme-ultraviolet wavelengths is described, and the design of sealed arrays for use at ultraviolet and visible wavelengths is briefly discussed.

Timothy, J. G.↗

Effect of counting and tracking on verbal and production methods of time estimation

The effects of time estimation technique and task condition on the production and verbal estimation of time intervals ranging from 5 to 14 sec were investigated. The duration of time intervals during each task condition pretracking, tracking (subject performed a one-axis tracking), and posttracking was estimated by the subjects. The ratio of the subject's time estimate to actual interval length was computed for each trial. Productions were typically longer than verbal estimates of the same duration and produced durations were typically too long whereas verbal estimates were too short relative to the correct duration. A significant interaction was found between counting technique and tracking condition for both estimation methods. A significant effect could be attributed to the addition of a tracking task: produced durations increased in length, whereas verbal estimates decreased in length. The durations produced without counting were significantly less accurate and consistent with the addition of a tracking task. Verbal estimation mean accuracy, but not consistency, was adversely affected by the addition of a tracking task when the subjects were instructed not to count.

Bird, K. L.↗

A preliminary look at astrometric accuracy as a function of photon counts

The importance of photon counts as a factor in the accuracy of astrometric positions is illustrated by a preliminary look at data collected with the Allegheny Observatory's photon-counting detector, the Multichannel Astrometric Photometer. Twenty estimates are plotted of the standard errors, per hour, of astrometric positions obtained with the photometer and the blue-light lens of the observatory's 30-inch refractor. The agreement between the estimated standard errors in the X and Y coordinates supports the conclusion that, as predicted by Drake, the accuracy is dependent upon the count rate.

Gatewood, G.↗

The Shane-Wirtanen counts - Observer and time-dependent effects

In a recent paper, de Lapparent, Kurtz, and Geller (1986) announce the discovery of possible observer and time-dependent effects in the counts of galaxies in the Lick catalog and suggest that these effects may have distorted the galaxy correlation function calculated by Groth and Peebles (1986) from the Lick counts. In particular, they suggest that these effects may have introduced a break where none exists or may have diluted a break stronger than that seen by Groth and Peebles. The Lick counts have been reexamined and it is found that the observer and time-dependent effects are marginal and that they can have had only a negligible effect on the estimates of the correlation functions. Correlation functions have been calculated for each observer and time period separately and it is found that they all depart from the small-angle power law at about the expected scale. Further, the average of these correlation functions agrees extremely well with the average correlation function published by Groth and Peebles.

Groth, Edward J.↗

Development of response models for the Earth Radiation Budget Experiment (ERBE) sensors. Part 4: Preliminary nonscanner models and count conversion algorithms

Two count conversion algorithms and the associated dynamic sensor model for the M/WFOV nonscanner radiometers are defined. The sensor model provides and updates the constants necessary for the conversion algorithms, though the frequency with which these updates were needed was uncertain. This analysis therefore develops mathematical models for the conversion of irradiance at the sensor field of view (FOV) limiter into data counts, derives from this model two algorithms for the conversion of data counts to irradiance at the sensor FOV aperture and develops measurement models which account for a specific target source together with a sensor. The resulting algorithms are of the gain/offset and Kalman filter types. The gain/offset algorithm was chosen since it provided sufficient accuracy using simpler computations.

Halyo, Nesim↗

Transformational part-count in layered octahedral-tetrahedral truss configurations

The number of component part (nodes, struts and panels) termed part count, is an important factor in the design, manufacture, and assembly of modular space structures. Part count expressions are presented for a variety of profiles derived from the layered octahedral-tetrahedral truss configuration. Referred to as the tetrahedral truss in the NASA projects, this specific geometry has been used in several missions. The general expressions presented here transforms to others as one profile changes to another. Such transformational part count relations provide a measure of flexibility and generality, and may be useful when dealing with a wider range of geometric configurations.

Lalvani, Haresh↗