Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 1 – Steady state modeling and speed ratio selection

Helium cryogenic systems which can provide cooling below the normal boiling point of helium (approximately 4.2 K) are often required by superconducting radio-frequency niobium resonators utilized in modern high-energy particle accelerators. Achieving temperatures below 4.2 K generally involves operating a cryogenic vessel with liquid helium under sub-atmospheric conditions, thereby lowering the saturation pressure and corresponding saturation temperature. Over the last several decades, multi-stage cryogenic centrifugal compressor trains (CC’s) have been operated efficiently and reliably within large-scale cryogenic systems to continuously evacuate helium vapor generated by a device within the vessel, maintaining sub-atmospheric conditions in the vessel while pressurizing the return vapor to above atmospheric conditions. Traditionally, these CC systems have been operated using empirically derived control philosophies and insight gathered from previous operational experience. Recent efforts at the Facility for Rare Isotope Beams (FRIB) have been aimed at the development of a theoretical basis to characterize the operation of multi-stage cryogenic centrifugal compressor train and utilizing predictive model results to generate control parameters. The objective of this research was identifying operational points which adequately balance cryogenic system efficiency, stability, and overall ease of operation. Furthermore, this manuscript provides an overview of the predictive model development, characterization of the FRIB cryogenic centrifugal compressors and implementation of the predicted performance results during steady-state system operation.

Compressor train control↗

First demonstration of a cryocooler conduction cooled superconducting radiofrequency cavity operating at practical cw accelerating gradients

Abstract We demonstrate practical accelerating gradients on a superconducting radiofrequency (SRF) accelerator cavity with cryocooler conduction cooling, a cooling technique that does not involve the complexities of the conventional liquid helium bath. A design is first presented that enables conduction cooling an elliptical-cell SRF cavity. Implementing this design, a single cell 650 MHz Nb 3 Sn cavity coupled using high purity aluminum thermal links to a 4 K pulse tube cryocooler generated accelerating gradients up to 6.6 MV m −1 at 100% duty cycle. The experiments were carried out with the cavity-cryocooler assembly in a simple vacuum vessel, completely free of circulating liquid cryogens. We anticipate that this cryocooling technique will make the SRF technology accessible to interested accelerator researchers who lack access to full-stack helium cryogenic systems. Furthermore, the technique can lead to SRF based compact sources of high average power electron beams for environmental protection and industrial applications. A concept of such an SRF compact accelerator is presented.

43 PARTICLE ACCELERATORS↗

Pulsating Heat Pipes for Accelerator Magnets. Phase I Final Report

The primary objective of the Phase 1 award was to investigate the performance of cryogenic pulsating heat pipes (PHPs) and their use in practical large superconducting magnet systems. PHPs exhibit an effective thermal conductivity an order of magnitude and more over high purity metals such as copper and aluminum. They can therefore be utilized to reduce cold mass and effectively transfer heat from the magnet system components such as the coil pack, shields, or current leads to cryocoolers or cryogen reservoirs.

43 PARTICLE ACCELERATORS↗

In-Field Testing of Components for Feedback and Control of the ITER Disruption Mitigation System

Here, the shattered pellet injection (SPI) method has been chosen as the disruption mitigation system (DMS) for ITER. To protect the device from plasma disruptions that cause damaging heat and electromagnetic loads, SPI is used to inject high-Z material into the plasma. The process of SPI utilizes cryogenic cooling to form solid pellets. Pellets are accelerated down a barrel and into an angled surface, causing the pellet to shatter prior to entering the tokamak chamber. For the DMS to function reliably, the 27 separate shattered pellet injectors planned for ITER must rely on many components to provide accurate feedback data and for control functions. Each component in the DMS is exposed to an elevated background magnetic field depending on its placement and proximity to the plasma chamber. A Helmholtz coil test stand that is operated at Oak Ridge National Laboratory was utilized to test the components in relevant background field levels to assess component performance. This paper details the test design and results for in-field component operation for a variety of components. This list includes the following components: two different network switches for camera connectivity, a VAT fast shutter valve intended to reduce the flow of SPI propellant gas into the torus, a solenoid control valve intended for use in the pellet formation process, pressure/vacuum switches to be used for feedback and control, a printed circuit board piezo pressure sensor to be used to measure breech pressure, and various relays for the high-voltage pulsed power supply used to drive the SPI propellant valve.

Disruption mitigation↗

Proton Improvement Plan II Cryogenic Distribution System thermodynamic design

The Proton Improvement Plan – II (PIP-II) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beams for neutrino production. The Linac requires cooling at 40 K, 5 K, and 2 K temperatures, which will be provided by cryogenic helium produced by a Helium Cryoplant and distributed by a Cryogenic Distribution System (CDS). Based primarily on the Linac heat load requirements at each temperature and the allowable pressure drop, we have made a preliminary thermodynamic design of the CDS. The design also incorporates special requirements such as controlled and/or fast cooldown of the superconducting RF cavities and their dual maximum allowable working pressures. This paper presents the overall features of the PIP-II CDS, sizing of helium process circuits, different operating modes, and calculated mass flow capacities that cater to these operating modes.

43 PARTICLE ACCELERATORS↗

Development of the first 1 GHz niobium-tin quarter-wave cavity

Niobium-Tin (Nb3Sn) is a promising alternative to pure niobium for low-beta ion accelerators due to low RF losses even at high frequencies. At 4.5 K, the expected Bardeen-Cooper-Schrieffer resistance of Nb3Sn is a few nano-Ohms at 1 GHz, with two orders of magnitude improvement compared to pure niobium. The low Nb3Sn RF losses allow the use of higher frequency, much smaller cavities while maintaining 4.5 K operation that is compatible with cryocoolers. This work aims to demonstrate the feasibility of coating a high-frequency 1 GHz, compact quarter-wave cavity. The development of this cavity has the potential to transform low-beta ion accelerators through size reductions and by enabling the replacement of large helium cryoplants with small plug-in cryocoolers. We have designed, built, and tested a 1GHz Nb3Sn coated quarter-wave cavity. Nb3Sn coating has been performed once by vapor diffusion at Fermilab. Cryogenic cold tests show a quality factor of ~1E9 at low accelerating electric fields or ~7 times higher than the theoretical limit for pure niobium at 1GHz. This first coating does not yet meet our quality factor or gradient goals; however, we plan to continue to develop this cavity.

Zhou, Yang [Argonne]↗

Status of the LCLS-II Cryogenic Distribution System

The LINAC Coherent Light Source II (LCLS-II) located at SLAC National Accelerator Laboratory (SLAC) in Menlo Park, CA, is a U.S. Department of Energy project tasked to design and build a world-class x-ray free-electron laser facility for scientific research. The Linac has superconducting radio frequency cryomodules that are connected to the cryogenic plant by the Cryogenic Distribution System (CDS), which consists of distribution boxes with heat exchangers and reliefs, feed caps, end caps, and surface, vertical, and bypass transfer lines. The CDS components were designed and built to specification by industry. The components have been delivered and their installation at SLAC will be discussed. The as-built relief system design will be presented, showing minimization of relief inlet pressure drops while meeting capacity requirements. The relieving flow pressure drops along the lengths of the CDS to centrally located reliefs at the distribution box were analysed to satisfy Pressure Vessel and Process Piping Code criteria to ensure relief performance. The sub-atmospheric 2 K circuit relieving approach will be discussed, which includes a three-way diverter isolation valve suitable for sub-atmospheric service. The component anchoring load design approach and installation into concrete floor will be discussed. This addresses loading, including seismic loading, along the component’s load path to floor anchoring system.

43 PARTICLE ACCELERATORS↗

Pressure safety approach for PIP-II cryogenic distribution system and cryomodules

The Proton Improvement Plan-II (PIP-II) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beam for neutrino production. The linac consists of a total of twenty-three (23) cryomodules of five (5) different types. Cooling is required at 2K, 5K and 40K. The Cryogenic Distribution System (CDS) consists of a Distribution Valve Box, ~285 m of cryogenic transfer line, modular Bayonet Cans to interface with cryomodules, and a Turnaround Can. The cryogenic system must provide protection from over-pressure by sizing pressure relief devices for all volumes and process line circuits. The cryomodule cavity circuits have dual pressure ratings, 4.1 bara when cold and 2.05 bara when warm (T>80K). Worst case relieving cases will be identified. The methods for determining heat flux will be presented. For the relieving occurring in the linac tunnel, flow must vent to outside to avoid an oxygen deficiency hazard. Also, we will present vacuum vessel relief sizing to protect the cryogenic distribution system vacuum shells from over pressure during an internal line rupture. The project is funded by US DOE Offices of Science, High Energy Physics.

43 PARTICLE ACCELERATORS↗

PIPII cryoplant non thermal cycling updates

The Proton Improvement Plan-II (PIP-II) is a crucial upgrade to the Fermilab accelerator complex, featuring a new 800-MeV Superconducting Radio-Frequency (SRF) linear accelerator (LINAC) with 23 cryomodules operating at 2K. The LINAC thermohydraulic conditions are satisfied by the cryogenic subsystems: Cryogenic Distribution System (CDS), a helium refrigerator cold box (CB), a warm compression station (WCS) and a helium recovery system (RSYS). The accelerator has a strict requirement of non-thermal cycling of the LINAC cryomodules during planned and unplanned subsystem outages. This paper presents an integrated operating modes analysis of the of the LINAC/CDS thermohydraulic loads satisfied by the CB/WCS cooling system supported by the RSYS inventory management system. The study is based on latest cryoplant and CDS engineering deliverables, as well as the recent performance data from single cryomodule qualification tests performed at the Fermilab PIP-II Injector Test test s tand. The study evaluates both normal and abnormal operating modes, with a focus on identifying integrated scenarios that put subsystems components under stress. The conclusions of this study will help build redundancy to reduce the risk of thermal cycles during planned and unplanned subsystem outages.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PIP-II cryoplant non thermal cycling updates

The Proton Improvement Plan-II (PIP-II) is a crucial upgrade to the Fermilab accelerator complex, featuring a new 800-MeV Superconducting Radio-Frequency (SRF) linear accelerator (LINAC) with 23 cryomodules operating at 2 K. The LINAC thermohydraulic conditions are satisfied by the cryogenic subsystems: Cryogenic Distribution System (CDS), a helium refrigerator cold box (CB), a warm compression station (WCS) and a helium recovery system (RSYS). The accelerator has a strict requirement of non-thermal cycling of the LINAC cryomodules during planned and unplanned subsystem outages. This paper presents an integrated reliability analysis of the PIPII cryoplant. The study evaluates both normal and abnormal operating modes, with a focus on identifying integrated scenarios that put subsystems components under stress. The conclusions of this study will help build redundancy to mitigate LINAC thermal cycling risks during planned and unplanned subsystem outages.

43 PARTICLE ACCELERATORS↗

Warm Compressor system Overview and status of the PIP-II cryogenic system

The Proton Improvement Plan-II (PIP-II) is a major upgrade to the Fermilab accelerator complex, featuring a new 800-MeV Superconducting Radio-Frequency (SRF) linear accelerator (Linac) powering the accelerator complex to provide the world's most intense high-energy neutrino beam. The PIP-II Linac consists of 23 SRF cryomodules operating at 2 K, 5 K, and 40 K temperature levels supplied by a single helium cryoplant providing 2.5 kW of cooling capacity at 2.0 K. The PIP-II cryogenic system consists of two major systems: a helium cryogenic plant and a cryogenic distribution system. The cryogenic plant includes a refrigerator cold box, a warm compressor system, and helium storage, recovery, and purification systems. The cryogenic distribution system includes a distribution box, intermediate transfer line, and a tunnel transfer line consisting of modular bayonet cans which supply and return cryogens to the cryomodules. A turnaround can is located at the end of the Linac to turnaround cryogenic flows. This paper describes the layout, design, and current status of the PIP-II cryogenic system.

43 PARTICLE ACCELERATORS↗

Pressure safety approach for PIP-II cryogenic distribution system and cryomodules

The Proton Improvement Plan-II (PIP-II) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beam for neutrino production. The linac consists of a total of twenty-three (23) cryomodules of five (5) different types. Cooling is required at 2K, 5K and 40K. The Cryogenic Distribution System (CDS) consists of a Distribution Valve Box, ~285 m of cryogenic transfer line, modular Bayonet Cans to interface with cryomodules, and a Turnaround Can. The cryogenic system must provide protection from over-pressure by sizing pressure relief devices for all volumes and process line circuits. The cryomodule cavity circuits have dual pressure ratings, 4.1 bara when cold and 2.05 bara when warm (T>80K). Worst case relieving cases will be identified. The methods for determining heat flux will be presented. For the relieving occurring in the linac tunnel, flow must vent to outside to avoid an oxygen deficiency hazard. Also, we will present vacuum vesse l relief sizing to protect the cryogenic distribution system vacuum shells from over pressure during an internal line rupture. The project is funded by US DOE Offices of Science, High Energy Physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mitigation of Dielectric Heating of Piezoelectric Actuators at Cryogenic Temperatures

The new generation of low beam intensity superconducting linacs will require high accelerating gradients for new scientific discoveries. The high accelerating gradient cavities in pulsed SRF linacs will experience large (~1000’s of Hz) detuning caused by Lorentz force detuning (LFD). The piezo actuators that will be used to compensate large LFD must operate at a nominal voltage of 120V to 150V to deliver the required stroke to the cavity. In this high voltage range, the piezo is expected to warm up drastically due to its location in an insulating vacuum environment. Overheating of the piezo will significantly decrease the longevity of the actuator. A collaboration between FNAL and Physik Instrumente (PI) developed a novel piezo actuator design that mitigates piezo overheating. The design consists of using a metal foam in contact with the piezoelectric ceramic stack for heat removal. The second solution used lithium niobite as an alternative material. A comparison of the temperature stability will be presented and discussed. This study characterizes the dielectric properties for both materials. The results obtained are in the temperature range of 10 K to 300 K.

43 PARTICLE ACCELERATORS↗

Comparison of copper and aluminum as the thermal link material for conduction-cooled accelerator cavities

Cryocooler conduction-cooling has recently emerged as a new frontier for cryogenic cooling for superconducting radiofrequency (SRF) cavities. In this scheme, an SRF cavity is mechanically coupled to a closed-cycle cryocooler using linkages made of high thermal conductivity metals. In this note, we compare the thermal transport properties of high purity aluminum and high purity copper as applied to SRF cavity conduction cooling. We show that copper can enable faster cooldown than aluminum from room temperature to the base temperature near 4 K and behave equally well or better during steady state cavity operation near the base temperature.

36 MATERIALS SCIENCE↗

Causes of fuel–ablator mix inferred from modeling of monochromatic time-gated radiography of OMEGA cryogenic implosions

Here, we present evidence, in the context of OMEGA cryogenic target implosions, that laser imprint, known to be capable of degrading laser-direct-drive target performance, plays a major role in generating fuel–ablator mix. OMEGA cryogenic target implosions show a performance boundary correlated with acceleration-phase shell stability; for sufficiently low adiabats (where the adiabat is the ratio of the pressure to the Fermi pressure) and high in-flight aspect ratios (IFAR's), the neutron-weighted shell areal density and neutron yield relative to the clean simulated values sharply decline. Direct evidence of Rayleigh–Taylor fuel–ablator mixing was previously obtained using a Si Heα backlighter driven by an ~20-ps short pulse generated by OMEGA EP. The shadow cast by the shell shortly prior to stagnation, as diagnosed using backlit radiographs, shows a softening near the limb, which is evidence of an ablator–fuel mix region for a low-adiabat implosion (α ~ 1.9, IFAR = 14) but not for a moderate adiabat implosion (α ~ 2.5, IFAR = 10). We find good agreement between experimental and synthetic radiographs in simulations that model laser imprint and account for uncertainty in the initial ablator thickness. Furthermore, we further explore the role of other mechanisms such as classical instability growth at the fuel–ablator interface, species concentration diffusion, and long-wavelength drive and target asymmetries.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent Progress Toward a Conduction-Cooled Superconducting Radiofrequency Electron Gun

High-repetition-rate electron sources have widespread applications. This contribution discusses the progress toward a proof-of-principle demonstration for a conduction-cooled electron source. The source consists of a simple modification of an elliptical cavity that enhances the field electric field at the photocathode surface. The source was cooled to cryogenic temperatures and preliminary measurements for the quality factor and accelerating field were performed. Additionally, we present future plans to improve the source along with simulated beam-dynamics performances.

43 PARTICLE ACCELERATORS↗

Experience of developing highly reliable Tuner components (piezo actuators and cold stepper motor actuators) for SRF Linac

The resonance control team at FNAL has led the design of the LCLS-II SRF Linac SRF cavity tuner subsystem. The Linac is expected to operate for over 30 years, and the longevity of the tuner is crucial to the overall reliability of the Linac. When the tuner's design was started, there were no active actuators (stepper and piezo) that could meet the longevity requirements of the Linac. The FNAL resonance control team, in collaboration with industrial partners (Phytron and PI), has developed actuators that have been shown to withstand a cryogenic and insulating vacuum environment for over 100 years in accelerated lifetime tests. Details of actuators design and longevity testing will be presented. Now, practically all (small and large) SRF systems that are under construction around the world are using actuators developed at FNAL. A review of possible actuators improvement will be presented.

Pischalnikov, Yuriy [Fermilab]↗

MEASUREMENT OF Fn 2 /Fp 2 FROM DEEP INELASTIC ELECTRON SCATTERING OFF A=3 MIRROR NUCLEI AT JEFFERSON LAB

This research is part of the Je?erson Lab MARATHON experiment (MeAsurement of the Fn 2 /Fp 2 , d/u RAtios and A = 3 EMC E?ect in Deep Inelastic Electron Scattering Off the Tritium and Helium MirrOr Nuclei). MARATHON is an experiment on electron deep inelastic scattering off the 3H, 3He mirror nuclei. It has extracted, from the measured deep inelastic scattering cross section ratio o? 3H and 3He, the ratio of the neutron to proton inelastic structure functions Fn 2 /Fp 2 . The extraction has taken advantage of the isospin symmetry of the A = 3 mirror nuclei within a novel technique, which avoids the theoretical uncertainties that are present in the SLAC experiments of the 1970s, which used hydrogen and deuterium targets. The experiment was performed using the upgraded 11 GeV beam of the Jefferson Lab electron accelerator, the Hall A Experimental Facility, and a newly designed cryogenic, high-pressure gas target system containing 3H and 3He cells. Electrons scattered o? the gas targets were detected in the two superconducting, high-resolution magnetic spectrometers of Hall A. The cross section data cover the four-momentum transfer squared range 2.0 < Q2 < 14.0 (GeV/c)2, and the Bjorken x scaling variable range 0.19 < x < 0.83. The experiment also measured, for calibration purposes, electron deep inelastic scattering off hydrogen and deuterium at selected kinematics.

Su, Tong↗