Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic chilldown”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Feasibility study for a Cryogenic On-Orbit Liquid Depot-Storage, Acquisition and Transfer (COLD-SAT) satellite

This feasibility study presents the conceptual design of a spacecraft for performing a series of cryogenic fluid management flight experiments. This spacecraft, the Cryogenic On-Orbit Liquid Depot-Storage, Acquisition, and Transfer (COLD-SAT) satellite, will use liquid hydrogen as the test fluid, be launched on a Delta expendable launch vehicle, and conduct a series of experiments over a two to three month period. These experiments will investigate the physics of subcritical cryogens in the low gravity space environment to characterize their behavior and to correlate the data with analytical and numerical models of in-space cryogenic fluid management systems. Primary technologies addressed by COLD-SAT are: (1) pressure control; (2) chilldown; (3) no-vent fill; (4) liquid acquisition device fill; (5) pressurization; (6) low-g fill and drain; (7) liquid acquisition device expulsion; (8) line chilldown; (9) thermodynamic state control; and (10) fluid dumping.

Rybak, S. C.↗

CFD Modeling of Bi-Directional PMD inside Cryogenic Propellant Tanks Onboard Parabolic Flights

Future cryogenic propulsion systems will require efficient methods with which to transfer cryogenic propellants from a depot storage tank to a customer receiver tank to minimize cost and maximize reusability. The Reduced Gravity Cryogenic Transfer project is currently developing advanced cryogenic fluid management technology and developing and validating new numerical models for three phases of transfer: line chilldown, tank chilldown, and tank fill. Additionally, multiple liquid nitrogen (LN 2 ) parabolic flight transfer rigs are being designed by universities and NASA to investigate the gravitational sensitivities that exist in these three technologies. In order to maximize the collection of low-g data during flights, it is required to extract as much (LN 2 as possible from the supply tank, despite variable gravity levels. The purpose of this paper is to present computational fluid dynamics (CFD) volume of fluid simulations of (LN 2 behavior in the supply tank onboard parabolic flights to validate the optimal design of a bi-directional propellant management device (PMD) using the commercial software FLOW-3D. A parametric study is conducted on the effects of gravity level, fill level, pore size, open area, thickness, and type of baffle on PMD performance. Based on results, the PMD as designed exceeds the targeted expulsion efficiency.

Jason Hartwig↗

Numerical Simulation of No-Vent Chill and Fill of a Large Liquid Hydrogen Tank

To enable the design of future in-space cryogenic propellant transfer vehicles, high accuracy models of the cryogenic propellant transfer process are desired. For in-space refueling applications, accurate simulations are desired of the propellant tank chilldown and no-vent fill (NVF) process in order to estimate the amount of propellant required, to determine the maximum sustainable flow rate to fill the tank, and to establish a timeline for the filling process. NVF is a complex process that involves numerous two-phase heat and mass transfer phenomena, such as boiling at the wall and evaporation and condensation at the liquid/vapor interface. In recent years, progress has been made in developing a numerical modeling technique using the Generalized Fluid System Simulation Program (GFSSP) that has been validated against several small-scale liquid nitrogen NVF tests. This paper presents GFSSP numerical model validation against three liquid hydrogen NVF tests on a large-scale propellant tank. Comparing the GFSSP model to the data for pressure, fill level, and wall temperature, the mean absolute percentage error is below 20% across the range of simulated conditions, indicating very good predictive agreement for this large-scale hydrogen NVF test series.

Alok Majumdar↗

Numerical Simulation of No-Vent Chill and Fill of a Large Liquid Hydrogen Tank

To enable the design of future in-space cryogenic propellant transfer vehicles, high accuracy models of the cryogenic propellant transfer process are desired. For in-space refueling applications, accurate simulations are desired of the propellant tank chilldown and no-vent fill (NVF) process in order to estimate the amount of propellant required, to determine the maximum sustainable flow rate to fill the tank, and to establish a timeline for the filling process. NVF is a complex process that involves numerous two-phase heat and mass transfer phenomena, such as boiling at the wall and evaporation and condensation at the liquid/vapor interface. In recent years, progress has been made in developing a numerical modeling technique using the Generalized Fluid System Simulation Program (GFSSP) that has been validated against several small-scale liquid nitrogen NVF tests. This paper presents GFSSP numerical model validation against three liquid hydrogen NVF tests on a large-scale propellant tank. Comparing the GFSSP model to the data for pressure, fill level, and wall temperature, the mean absolute percentage error is below 20% across the range of simulated conditions, indicating very good predictive agreement for this large-scale hydrogen NVF test series.

Alok Majumdar↗

Extended temperature range ACPS thruster investigation

The successful hot fire demonstration of a pulsing liquid hydrogen/liquid oxygen and gaseous hydrogen/liquid oxygen attitude control propulsion system thruster is described. The test was the result of research to develop a simple, lightweight, and high performance reaction control system without the traditional requirements for extensive periods of engine thermal conditioning, or the use of complex equipment to convert both liquid propellants to gas prior to delivery to the engine. Significant departures from conventional injector design practice were employed to achieve an operable design. The work discussed includes thermal and injector manifold priming analyses, subscale injector chilldown tests, and 168 full scale and 550 N (1250 lbF) rocket engine tests. Ignition experiments, at propellant temperatures ranging from cryogenic to ambient, led to the generation of a universal spark ignition system which can reliably ignite an engine when supplied with liquid, two phase, or gaseous propellants. Electrical power requirements for spark igniter are very low.

Blubaugh, A. L.↗

OTV orbital tanking systems

Orbital transfer of cryogenic propellants could benefit spacecraft and Orbital Transfer Vehicle (OTV) missions in the 1980s by supplying main propulsion, attitude control, or other fluid systems. The Space Shuttle can operate as a tanker when equipped with cryogenic propellant storage and orbital transfer systems. The key technologies are multilayer insulation, capillary propellant acquisition, zero-g gaging, orbital chilldown, and possibly large flight weight dewars. The technologies and operations could be realistically demonstrated using a Centaur that has been integrated with the Shuttle. Orbital refueling capability can enhance the usefulness of the whole Shuttle program

Heald, D. A.↗

Cryogenic fluid transfer - orbital transfer vehicle

Fluid transfer requirements are presented for the orbital transfer vehicle (OTV) issues such as OTV configuration, hardware design and size are taken into consideration. Tank chilldown, tank fill and thermodynamic properties are all evaluated in relationship to fluid transfer needs.

Hastings, L. J.↗

Heat Transfer Enhancement in Cryogenic Quenching Process

This paper reports a heat transfer advancement in the cryogenic quenching process. An experiment was performed to evaluate the enhancement of quenching heat transfer by the use of metal tubes with low thermal conductivity coating layers. Four coating thicknesses with various coolant mass flow rates of liquid nitrogen were investigated. The results indicated that the tube inner surface coating greatly enhanced the quenching efficiency. The quenching efficiency was found to increase with increasing number of coating layers, and the efficiency also increased with decreasing mass flow rates. In general, the efficiencies cover a range between 40.6% and 80%. Comparing to the bare surface case, the percentage increase in the quenching efficiency was the minimum at 4.2% for a single coated layer at the highest flow rate and the maximum of 109.1% for four coated layers at the lowest flow rate. The coated tubes could save up to 53% in the amount of cryogen consumption.

Surface coating↗

CFD Predictions of Boiling Regime Transitions during Line Chilldown validated against a 1G LN2 Experiment

Introduction Before filling a propellant tank on the ground or in Space, the transfer line between the donor and receiver tanks must be cooled down preferably by sacrificing a minimum amount of the cryogenic fluid. The cryogenic line chill-down process involves a transition between different flow boiling regimes, namely, film boiling, transition film boiling, and nucleate boiling which are complex and may be quite gravity-dependent. Capturing these boiling phenomena and predicting the transition between them in a CFD framework is new and challenging both for 1g and microgravity applications. Materials & Methods The present work addresses this challenge by employing a two-phase Eulerian approach in the context of a homogeneous fluid mixture together with the Lee phase change model to capture the film boiling regime of the chill-down process using ANSYS Fluent®. The nucleate boiling regime is predicted by incorporating an in-house developed sub-grid model that accounts for bubble nucleation, bubble growth, bubble departure diameter, and their shedding frequency. The sub-grid model is encoded and implemented into Fluent via a user-defined function for the wall-fluid heat flux calculations. The mathematical formulation and numerical implementation of the CFD model are described in detail. The coupled CFD-Subgrid model is validated against published experimental data for liquid nitrogen chill-down of a heated stainless-steel pipe in 1g. Results Numerical simulation results show good agreements between the CFD predictions of the wall temperature evolution, rewetting temperature, and transition between film and nucleate boiling, with the experimental measurements published by Darr et al [2] for several different LN2 flowrates in the vertical pipe orientation. The CFD predictions for the wall temperature distribution indicate a rapid quenching of the wall at two upstream and downstream temperature sensing locations as compared to the experimental measurement. The only tuning parameter in the CFD model is the Lee mass transfer coefficient. The CFD Model predicts the Liedenfrost rewetting temperature in close agreement with the experiment. This marks a transition between stable and transitionary flow boiling regimes. The CFD-predicted boiling curve for the downstream sensor location is also compared against its experimental counterpart and indicates that the model is able to predict all the key temperature and heat flux parameters during the transitions from stable to transitionary film boiling to nucleate boiling in close agreement with the experiment. A sequence of predicted volume fraction, and temperature contours depicting these transitions will be presented.

Evaporation Condensation↗

Large-Scale Liquid Hydrogen Tank Rapid Chill and Fill Testing for the Advanced Shuttle Upper Stage Concept

Cryogenic upper stages in the Space Shuttle program were prohibited primarily due to a safety risk of a 'return to launch site' abort. An upper stage concept addressed this concern by proposing that the stage be launched empty and filled using shuttle external tank residuals after the atmospheric pressure could no longer sustain an explosion. However, only about 5 minutes was allowed for tank fill. Liquid hydrogen testing was conducted within a near-ambient environment using the multipurpose hydrogen test bed 638.5 ft3 (18m3) cylindrical tank with a spray bar mounted longitudinally inside. Although the tank was filled within 5 minutes, chilldown of the tank structure was incomplete, and excessive tank pressures occurred upon vent valve closure. Elevated tank wall temperatures below the liquid level were clearly characteristic of film boiling. The test results have substantial implications for on-orbit cryogen transfer since the formation of a vapor film would be much less inhibited due to the reduced gravity. However, the heavy tank walls could become an asset in normal gravity testing for on-orbit transfer, i.e., if film boiling in a nonflight weight tank can be inhibited in normal gravity, then analytical modeling anchored with the data could be applied to reduced gravity environments with increased confidence.

Flachbart, R. H.↗

On-orbit cryogenic storage and resupply

Methods of integrating pressure control, liquid acquisition, and liquid transfer concepts for the Cryogenic Fluid Management Facility, a reusable test bed in the Shuttle cargo bay studying the efficient management of cryogens in space, are investigated. Significant design data and criteria for future subcritical cryogenic storage and transfer systems are presented. Technology requirements for liquid storage/supply systems, thermal control systems, and fluid transfer/resupply are addressed, and fluid and thermal analysis pertaining to receiver tank chilldown and no-vent fill of the receiver tank are discussed.

Eberhardt, R. N.↗

CRYOTE (Cryogenic Orbital Testbed) Concept

Demonstrating cryo-fluid management (CFM) technologies in space is critical for advances in long duration space missions. Current space-based cryogenic propulsion is viable for hours, not the weeks to years needed by space exploration and space science. CRYogenic Orbital TEstbed (CRYOTE) provides an affordable low-risk environment to demonstrate a broad array of critical CFM technologies that cannot be tested in Earth's gravity. These technologies include system chilldown, transfer, handling, health management, mixing, pressure control, active cooling, and long-term storage. United Launch Alliance is partnering with Innovative Engineering Solutions, the National Aeronautics and Space Administration, and others to develop CRYOTE to fly as an auxiliary payload between the primary payload and the Centaur upper stage on an Atlas V rocket. Because satellites are expensive, the space industry is largely risk averse to incorporating unproven systems or conducting experiments using flight hardware that is supporting a primary mission. To minimize launch risk, the CRYOTE system will only activate after the primary payload is separated from the rocket. Flying the testbed as an auxiliary payload utilizes Evolved Expendable Launch Vehicle performance excess to cost-effectively demonstrate enhanced CFM.

Gravlee, Mari↗

Numerical Simulation of No Vent Chill and Fill of a Large Liquid Hydrogen Tank

On orbit transfer of cryogenic liquids is necessary for many future space missions. The techniques required to transfer cryogens in micro gravity are quite different from ground system applications. In normal gravity, cryogenic tanks are usually filled from the bottom at nearly atmospheric pressure. The vapor generated due to heat transfer from warm tank walls, is allowed to vent from the top of the tank while the tank is being filled. If the normal gravity technique is used on orbit, the uncertainty of liquid and vapor distributions in unsettled condition may result in dumping of large amounts of liquid propellant overboard. The Vented Chill and No Vent Fill (VCNVF) process is a methodology [1] used to reduce propellant loss by holding the vent valve open during initial wall chilldown, preventing over-pressurization of the tank and stalling of the incoming flow, but closing the tank vent valve after chilling the tank wall sufficiently. An accurate simulation of no vent tank chill and fill is necessary to estimate the amount of propellant necessary to chill the tank, determine the maximum sustainable flowrate to fill the tank without stalling, and establish a timeline for the filling process. Numerical modeling of filling a cryogenic tank is complex because the flow is two-phase and the process involves both boiling and condensation with heat transfer between solid and fluid. In recent years, progress has been made to develop a numerical modeling technique [2,3,4] that has been verified by comparing with the test data from a small flight tank using liquid nitrogen [5]. The purpose of the present paper is to apply this technique in a larger tank with liquid hydrogen and compare with the test data of Chato [1]. The K-site Test Facility [1], shown in Figure 1, consists of a Test Tank, spray system, instrumentation, and the vacuum chamber. The test tank selected was ellipsoidal with an 87 inch major diameter and a 1.2 to 1 major to minor axis ratio. The two ends are joined by a short 1.5 inch cylindrical section. The tank is made of 2219 aluminum chemically milled to a nominal thickness of 0.087 inches. The tank weighs 329.25 pounds, and the tank volume is 175 ft 3 . The GFSSP model of the Test Tank is shown in Figure 2. Node 13 is a boundary node that represents the supply tank which is supplying liquid hydrogen at a given pressure and temperature. The total measured flowrate is evenly distributed through Branches 131 through 139. Nodes 1 through 9 represent the test tank and they are connected with metal solid nodes 14 through 22 through fluid-to-solid conductors that allow convective heat transfer between the solid and fluid nodes. The predicted tank pressure, filling rate, wall temperature and fluid temperature will be compared with test data.

Alok Majumdar↗

Cryogenic On-Orbit Liquid Depot Storage, Acquisition, and Transfer Satellite (COLD-SAT)

The Cryogenic On-Orbit Liquid Depot Storage, Acquisition, and Transfer Satellite (COLD-SAT) will perform subcritical liquid hydrogen handling experiments under low gravity conditions to provide engineering data for future space transportation missions. Comprising the four Class 1 enabling experiments are tank press control, tank chilldown, tank no-vent fill, and liquid acquisition device fill/refill. The nine Class 2 enhancing experiments are tanker thermal performance, pressurization, low-gravity setting and outflow, liquid acquisition device performance, transfer line chilldown, outflow subcooling, low-gravity vented fill, fluid dumping, and advanced instrumentation. Consisting of an experiment module mated to a spacecraft bus, COLD-SAT will be placed in an initial 1300 km circular orbit by an Atlas commercial launch vehicle, and will perform experiments in a semi-autonomous mode for a period of up to six months. The three-axis controlled spacecraft bus provides electric power, control and data management, communications, and attitude control along with propulsive acceleration levels ranging from 10(exp -6) to 10(exp -4) g. It is desired to understand the effects that low acceleration levels might have on the heat and mass transfer processes involved in some of the experiments. The experiment module contains the three liquid hydrogen tanks, valves, pressurization and pumping equipment, and instrumentation. Within the highly insulated tanks are specialized fluid management equipment that might be used in future space transportation systems. At launch all the liquid hydrogen for the experiments is contained in the largest tank, which has helium-purged insulation to prevent cryo-pumping of air on the launch pad. The tank is loaded by the hydrogen tanking system used for the Centaur upper stage of the Atlas. After reaching orbit the two smaller tanks become receivers for fluid transfers, and when tanked, become the vessels for performing many of the experiments.

Schuster, John R.↗

OTV fluid mangement systems

Design, performance, and technology issues associated with reduced gravity propellant management for orbital transfer vehicles (OTV's) are reviewed. The in-space cryogenic management state-of-technology significantly affects the overall confidence level associated with a resupply mission and propulsion performance. Cryogen resupply sequences, timelines, controls, and associated crew involvement are all affected by the technology state. Additionally, OTV propellant tankage configurations, tankage thermodynamic conditions, acceleration environment, propulsion interfaces, and instrumentation are significant factors. Basic propellant transfer phases examined that drive orbital servicing requirements include: (1) tankage preconditioning; (2) tankage chilldown; and (3) propellant fill. Propellant management support of the OTV propulsion phases includes engine restart requirements and orbital coast between engine burns. Technology activities in support of identified technology issues are reviewed.

Hastings, L.↗

Thermodynamic analysis and subscale modeling of space-based orbit transfer vehicle cryogenic propellant resupply

The resupply of the cryogenic propellants is an enabling technology for spacebased orbit transfer vehicles. As part of the NASA Lewis ongoing efforts in microgravity fluid management, thermodynamic analysis and subscale modeling techniques were developed to support an on-orbit test bed for cryogenic fluid management technologies. Analytical results have shown that subscale experimental modeling of liquid resupply can be used to validate analytical models when the appropriate target temperature is selected to relate the model to its prototype system. Further analyses were used to develop a thermodynamic model of the tank chilldown process which is required prior to the no-vent fill operation. These efforts were incorporated into two FORTRAN programs which were used to present preliminary analyticl results.

Defelice, David M.↗

Thermodynamic analysis and subscale modeling of space-based orbit transfer vehicle cryogenic propellant resupply

The resupply of the cryogenic propellants is an enabling technology for spacebased orbit transfer vehicles. As part of the NASA Lewis ongoing efforts in microgravity fluid management, thermodynamic analysis and subscale modeling techniques were developed to support an on-orbit test bed for cryogenic fluid management technologies. Analytical results have shown that subscale experimental modeling of liquid resupply can be used to validate analytical models when the appropriate target temperature is selected to relate the model to its prototype system. Further analyses were used to develop a thermodynamic model of the tank chilldown process which is required prior to the no-vent fill operation. These efforts were incorporated into two FORTRAN programs which were used to present preliminary analytical results.

Defelice, David M.↗

Settled Cryogenic Propellant Transfer

Cryogenic propellant transfer can significantly benefit NASA s space exploration initiative. LMSSC parametric studies indicate that "Topping off" the Earth Departure Stage (EDS) in LEO with approx.20 mT of additional propellant using cryogenic propellant transfer increases the lunar delivered payload by 5 mT. Filling the EDS to capacity in LEO with 78 mT of propellants increases the delivered payload by 20 mT. Cryogenic propellant transfer is directly extensible to Mars exploration in that it provides propellant for the Mars Earth Departure stage and in-situ propellant utilization at Mars. To enable the significant performance increase provided by cryogenic propellant transfer, the reliability and robustness of the transfer process must be guaranteed. By utilizing low vehicle acceleration during the cryogenic transfer the operation is significantly simplified and enables the maximum use of existing, reliable, mature upper stage cryogenic-fluid-management (CFM) techniques. Due to settling, large-scale propellant transfer becomes an engineering effort, and not the technology development endeavor required with zero-gravity propellant transfer. The following key CFM technologies are all currently implemented by settling on both the Centaur and Delta IV upper stages: propellant acquisition, hardware chilldown, pressure control, and mass gauging. The key remaining technology, autonomous rendezvous and docking, is already in use by the Russians, and must be perfected for NASA whether the use of propellant transfer is utilized or not.

Kutter, Bernard F.↗