Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Design and Comparison of Lunar Sample Return Options

Returning lunar samples to earth is a high priority for NASA in order to better understand Lunar Geology, Lunar formation, and potential resource utilization. Core samples of frozen volatiles from permanently shadowed regions are sought after, but require intensive cryogenic cooling to preserve. Returning samples to Earth using the Orion capsule is restrictive for moderate amounts of mass/volume and thus alternate means of transport are investigated in this paper. The trade-space of potential options includes varying: sample mass amount, sample containment conditions, transfer path from Lunar surface to Earth surface, and various vehicle system trades. An integrated solver is applied with parametric estimators and known system heuristics to effectively estimate size, mass, and power of various subsystems. Modeled subsystems include sample containment, EDL technologies(heat shield, parachute, recovery), power, thermal, avionics, structures, and propulsive systems. Transfer path options include various trajectory options, transfer methods, staging points, and vehicle staging options. A Design of Experiments was conducted to explore the tradespace, to identify sensitivities, and to identify promising designs. Results are detailed for various stakeholder objectives including total mass, sample mass, science return, architecture impacts, and operational flexibility.

Lunar outpost↗

Collecting Ground Samples for Balloon-Borne Instruments

A proposed system in a gondola containing scientific instruments suspended by a balloon over the surface of the Saturn moon Titan would quickly acquire samples of rock or ice from the ground below. Prototypes of a sample-collecting device that would be a major part of the system have been tested under cryogenic and non-cryogenic conditions on Earth. Systems like this one could also be used in non-cryogenic environments on Earth to collect samples of rock, soil, ice, mud, or other ground material from such inaccessible or hazardous locations as sites of suspected chemical spills or biological contamination. The sample-collecting device would be a harpoonlike device that would be connected to the balloon-borne gondola by a tether long enough to reach the ground. The device would be dropped from the gondola to acquire a sample, then would be reeled back up to the gondola, where the sample would be analyzed by the onboard instruments. Each prototype of the sample-collecting device has a sharp front (lower) end, a hollow core for retaining a sample, a spring for holding the sample in the hollow core, and a rear (upper) annular cavity for retaining liquid sample material. Aerodynamic fins at the rear help to keep the front end pointed downward. In tests, these prototype devices were dropped from various heights and used to gather samples of dry sand, moist sand, cryogenic water ice, and warmer water ice.

Jones, Jack↗

Dynamic Mechanical Analysis of Post-Cured Bismaleimide Resins for Composite-Overwrapped Combustion Chambers Cycled From Cryogenic to High Temperatures

In support of the Rapid Analysis and Manufacturing Propulsion Technology (RAMPT) project, samples made of polybismaleimide (BMI) resin were made and tested under cryogenic conditions. Neat resin samples were tested for multiple cycles, from high temperature (300°C) to cryogenic temperature (-150°C), to replicate the conditions a rocket engine assembly would experience in a test campaign and in operation. To increase the glass transition temperature (and thus mechanical stability), samples were exposed to different post-cure temperatures and were tested using a dynamic mechanical analysis (DMA) instrument. Consistent with expectations, the BMI samples post-cured at higher temperatures generally resulted in higher storage modulus under high temperature test conditions but at the expense of storage modulus values at low temperature test conditions.

Christopher Stelter↗

Instrumentation for in situ sampling and analysis of compounds of interest to Astrobiology in the lower atmosphere and surface of Titan

Instrumentation for exploration of the solar system will require new enabling technology for in situ sample acquisition and analysis of pre-biotic chemistry in extreme planetary environments, such as that encountered at the surface of Titan. The potential use of balloon aero-rovers for Titan places special emphasis on the importance of miniaturization, low power and low usage of consumables. To help meet this need, we are developing a miniature gas chromatograph coupled with a new Mini-Cell ion mobility spectrometer (GC-IMS), and one of us (PMH) has begun development work on a miniaturized cryogenic inlet system with sampling probes for Titan. This instrumentation, and its approach for meeting measurement needs for the analysis of prebiotic chemistry on Titan, will be discussed.

Holland, Paul M.↗

Study of the Thermal Physical Properties of Insulating Materials in A Titan Environment

Dragonfly is a planned rotorcraft mission that NASA/APL will be sending to Saturn’s moon Titan to study its chemistry. The Dragonfly Mass Spectrometer (DraMS) is a mass spectrometer that is being developed to identify different kinds of organic material that comprises Titan’s surface. The Cryogenic engineering team on DraMS is developing and interface between the room temperature rotorcraft body and the near-cryogenic temperatures of an onboard sample chamber, while minimizing the thermal leak to the Titan environment. As part of design process, the Cryogenic team has built a conductivity test rig for testing the thermophysical properties of candidate insulators, which includes Rohacell 31HF and hollowed 3D printed PEEK structures, at simulated Titan environmental conditions.

Thermal Conductivity↗

X-ray fluorescence analysis of alloy and stainless steels using a mercuric iodide detector

A mercuric iodide detector was used for the XRF analysis of a number of NBS standard steels, applying a specially developed correction method for interelemental effects. It is shown that, using this method and a good peak-deconvolution technique, the HgI2 detector is capable of achieving resolutions and count rates needed in the XRF anlysis of multielement samples. The freedom from cryogenic cooling and from power supplies necessary for an electrically cooled device makes this detector a very good candidate for a portable instrument.

Kelliher, Warren C.↗

Vertical distribution of CH4 and N2O over the tropical site Hyderabad

Vertical distribution profiles of N2O and CH4 have been measured from Hyderabad, India using a balloon-borne cryogenic air sampler. The samples have been analyzed using gas chromatographic techniques. Results for two balloon flights made in 1987 and 1990 show effects of tropical characteristics like higher tropopause and upwelling motion due to Hadley circulation. These profiles also exhibit perturbations around 25 km height, which are likely to be due to dynamical effects. A comparison with the SAMS data show that the SAMS values for both these gases are higher by a factor of about 1.5 to 2 around 30 km height.

Lal, Shyam↗

Atmospheric measurements of carbonyl sulfide, dimethyl sulfide, and carbon disulfide using the electron capture sulfur detector

Measurements of atmospheric dimethyl sulfide (DMS), carbonyl sulfide (COS), and carbon disulfide (CS2) were conducted over the Atlantic Ocean on board the NASA Electra aircraft during the Chemical Instrumentation Test and Evaluation (CITE 3) project using the electron capture sulfur detector (ECD-S). The system employed cryogenic preconcentration of air samples, gas chromatographic separation, catalytic fluorination, and electron capture detection. Samples collected for DMS analysis were scrubbed of oxidants with NaOH impregnated glass fiber filters to preconcentration. The detection limits (DL) of the system for COS, DMS, and CS2 were 5, 5, and 2 ppt, respectively. COS concentrations ranged from 404 to 603 ppt with a mean of 489 ppt for measurements over the North Atlantic Ocean (31 deg N to 41 deg N), and from 395 to 437 ppt with a mean of 419 ppt for measurements over the Tropical Atlantic Ocean (11 deg S to 2 deg N). DMS concentrations in the lower marine boundary layer, below 600-m altitude, ranged from below DL to 150 ppt from flights over the North Atlantic, and from 9 to 104 ppt over the Tropical Atlantic. CS2 concentrations ranged from below DL to 29 ppt over the North Atlantic. Almost all CS2 measurements over the Tropical Atlantic were below DL.

Johnson, James E.↗

Mission Incredible: A Titan Sample Return Using In-Situ Propellants

An analysis of the use of in-situ volatile propellants for a sample return mission from Titan shows that this mission should be feasible. Such a mission would be invaluable for its science return, and its contribution to our understanding the origins of organic compounds in the solar system and our place in the universe.

Titan↗

Compact drilling and sample system

The Compact Drilling and Sample System (CDSS) was developed to drill into terrestrial, cometary, and asteroid material in a cryogenic, vacuum environment in order to acquire subsurface samples. Although drills were used by the Apollo astronauts some 20 years ago, this drill is a fraction of the mass and power and operates completely autonomously, able to drill, acquire, transport, dock, and release sample containers in science instruments. The CDSS has incorporated into its control system the ability to gather science data about the material being drilled by measuring drilling rate per force applied and torque. This drill will be able to optimize rotation and thrust in order to achieve the highest drilling rate possible in any given sample. The drill can be commanded to drill at a specified force, so that force imparted on the rover or lander is limited. This paper will discuss the cryo dc brush motors, carbide gears, cryogenic lubrication, quick-release interchangeable sampling drill bits, percussion drilling and the control system developed to achieve autonomous, cryogenic, vacuum, lightweight drilling.

Gillis-Smith, Greg R.↗

Recent Developments in the Curation of Cold, Volatile-Rich Extraterrestrial Samples

In recent years, the study of samples from cold, potentially volatile-rich Solar System bodies has increased dramatically. Returned samples from low- or cryogenic-temperature regions are highly sensitive to ambient temperatures, pressures, and materials. In order to maximize the scientific utility of such samples, they must be returned, handled, and stored under conditions that minimize sample alteration and contamination. The Johnson Space Center (JSC) Astromaterials Acquisition and Curation Office (hereafter called the Curation Office) is currently developing the ability to curate cold, volatile-rich samples; this abstract summarizes these efforts for Apollo lunar samples, organic-rich meteorites, comet samples, and lunar polar samples.

Mitchell, J. L.↗

An Experimental Study of Launch Vehicle Propellant Tank Fragmentation

In order to better understand launch vehicle abort environments, Bangham Engineering Inc. (BEi) built a test assembly that fails sample materials (steel and aluminum plates of various alloys and thicknesses) under quasi-realistic vehicle failure conditions. Samples are exposed to pressures similar to those expected in vehicle failure scenarios and filmed at high speed to increase understanding of complex fracture mechanics. After failure, the fragments of each test sample are collected, catalogued and reconstructed for further study. Post-test analysis shows that aluminum samples consistently produce fewer fragments than steel samples of similar thickness and at similar failure pressures. Video analysis shows that there are several failure 'patterns' that can be observed for all test samples based on configuration. Fragment velocities are also measured from high speed video data. Sample thickness and material are analyzed for trends in failure pressure. Testing is also done with cryogenic and noncryogenic liquid loading on the samples. It is determined that liquid loading and cryogenic temperatures can decrease material fragmentation for sub-flight thicknesses. A method is developed for capture and collection of fragments that is greater than 97 percent effective in recovering sample mass, addressing the generation of tiny fragments. Currently, samples tested do not match actual launch vehicle propellant tank material thicknesses because of size constraints on test assembly, but test findings are used to inform the design and build of another, larger test assembly with the purpose of testing actual vehicle flight materials that include structural components such as iso-grid and friction stir welds.

Richardson, Erin↗

Analysis of Screen Channel LAD Bubble Point Tests in Liquid Methane at Elevated Temperature

This paper examines the effect of varying the liquid temperature and pressure on the bubble point pressure for screen channel Liquid Acquisition Devices in cryogenic liquid methane using gaseous helium across a wide range of elevated pressures and temperatures. Testing of a 325 x 2300 Dutch Twill screen sample was conducted in the Cryogenic Components Lab 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. Test conditions ranged from 105 to 160K and 0.0965 - 1.78 MPa. Bubble point is shown to be a strong function of the liquid temperature and a weak function of the amount of subcooling at the LAD screen. The model predicts well for saturated liquid but under predicts the subcooled data.

Hartwig, Jason↗

Analysis of Screen Channel LAD Bubble Point Tests in Liquid Oxygen at Elevated Temperature

The purpose of this paper is to examine the key parameters that affect the bubble point pressure for screen channel Liquid Acquisition Devices in cryogenic liquid oxygen at elevated pressures and temperatures. An in depth analysis of the effect of varying temperature, pressure, and pressurization gas on bubble point is presented. Testing of a 200 x 1400 and 325 x 2300 Dutch Twill screen sample was conducted in the Cryogenics Components Lab 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. Test conditions ranged from 92 to 130K and 0.138 - 1.79 MPa. Bubble point is shown to be a strong function of temperature with a secondary dependence on pressure. The pressure dependence is believed to be a function of the amount of evaporation and condensation occurring at the screen. Good agreement exists between data and theory for normally saturated liquid but the model generally under predicts the bubble point in subcooled liquid. Better correlation with the data is obtained by using the liquid temperature at the screen to determine surface tension of the fluid, as opposed to the bulk liquid temperature.

Hartwig, Jason↗

Development of the Thermal Interface Between the Dragonfly Mass Spectrometer and the DrACO Sample Delivery Carousel

Icy celestial bodies are an exciting new frontier for surface exploration and in-situ sampling and analysis. These destinations are inherently cryogenic in nature, and each body presents unique challenges related to thermal design. The Dragonfly mission to Titan is one such example. One of the most important requirements of a sampling system is to preserve the integrity of the surface material. The interface between the Dragonfly Mass Spectrometer (DraMS) and the Drill for Acquisition of Complex Organics (DrACO) is complicated by several competing requirements. Development of this interface has required the use of new enabling technologies such as 3D printing to achieve a successful design. This overview of the DraMS Cryogenic subsystem will show how the design meets all the requirements of the interface and preserves integrity of Titan surface samples.

Peter W. Barfknecht↗