Search NASA⌕ Search

SEARCH · Search NASA

Results for “curing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Designing Cure Cycles for Matrix/Fiber Composite Parts

A methodology has been devised for designing cure cycles to be used in the fabrication of matrix/fiber composite parts (including laminated parts). As used here, cure cycles signifies schedules of elevated temperature and pressure as functions of time, chosen to obtain desired rates of chemical conversion of initially chemically reactive matrix materials and to consolidate the matrix and fiber materials into dense solids. Heretofore, cure cycles have been designed following an empirical, trial-and-error approach, which cannot be relied upon to yield optimum results. In contrast, the present methodology makes it possible to design an optimum or nearly optimum cure cycle for a specific application. Proper design of a cure cycle is critical for achieving consolidation of a reactive matrix/fiber layup into a void-free laminate. A cure cycle for a composite containing a reactive resin matrix usually consists of a two-stage ramp-and-hold temperature profile. The temperature and the duration of the hold for each stage are unique for a given composite material. The first, lower-temperature ramp-and hold stage is called the B stage in composite- fabrication terminology. At this stage, pressure is not applied, and volatiles (solvents and reaction by-products) are free to escape. The second, higher-temperature stage is for final forced consolidation.

Hou, Tan-Hung↗

Investigation of Lunar-Inspired Geopolymer Concrete Formulations Mixed and Cured in Microgravity on the International Space Station (ISS)

The research outlined in this presentation investigates the use of various lunar regolith simulants in geopolymer lunar concrete mixes mixed and cured on the International Space Station (ISS). The motivation for this work is to study the effects of gravity on the microstructure of alkali-activated materials cured with heat, and to develop materials for the construction of long-term infrastructure on the lunar surface with in-situ resource utilization (ISRU). ISRU for construction materials reduces the cost and mass of payloads related to lunar construction. The advantage of geopolymer concrete as opposed to traditional portland cement concrete is that water acts as a medium for the polymerization reaction and leaves the system throughout the process, reducing its demand. Twelve samples of lunar regolith simulant and a solution composed of sodium hydroxide and sodium silicate were sent to the ISS. The three simulants were OPRH2N, OPRL2N, and JSC-1AF, using only particles less than 53 µm in diameter to increase reactivity of the simulant. Simulant to solution ratios were determined by workability while mixing. The simulant and solution were sealed Burst Pouches® along with 2 other sealed bags to prevent material from leaking. Crew member F-14 conducted testing on the ISS by introducing the solution to the simulant in the Burst Pouch®, mixing the sample with a spatula, and then clamping the specimen in the fresh state to prevent flow inside the Burst Pouch®. These specimens were then put in a thermos heated to 80C via sealed drinking water bags to cure for 24 hours with a temperature logger. The cured specimens remained in microgravity for at least 28 days and were returned from the ISS in February 2025. The specimens were then brought to the NASA Marshall Space Flight Center (MSFC) to analyze. Material characterization consisted of conducting Micro-CT tests of entire samples in their sealed apparatus to a resolution of 25µm. 2D image slices were saved in each orthogonal direction of each specimen at a 0.03 mm step size from the 3D model to conduct analytical porosity calculations. Representative samples from each specimen were sampled to perform helium gas pycnometery and were then mounted in resin for SEM imaging, EDS, and nanoindentation. Porosity was analyzed analytically using micromechanics modelling with the assistance of the NASA Multiscale Analysis Tool (NASMAT), as well as the NASA Advanced Supercomputing (NAS) servers (V. Saseendran & N. Yamamoto, 2024). Density was measured using helium gas pycnometery and was then compared to the theoretical density for experimental porosity calculation. Due to the samples’ non-uniform shape being cured in a pouch, traditional compression and tensile strength testing could not be performed. Nanoindentation was conducted at Clarkson University to determine the microhardness and reduced modulus of elasticity. Results from flight samples can be compared to ground samples currently in DLR’s possession to determine the effect on microstructure from being mixed and cured in microgravity. This study gives further insight and understanding of geopolymer lunar concrete and its viability as a lunar construction material with ISRU.

Adam Johnson↗

Effect of Composition Variation on Isothermal Rapid Curing Resins for Aerospace Applications

To meet the projected demand for single-aisle composite aircraft in 2040, the production rate of these aircraft will need to increase by four to six times what is currently achievable. A composite manufacturing process with the potential to enable the targeted rates is isothermal resin infusion where infusion and cure occur at the same temperature. However, presently there is not an accepted aerospace-grade resin that can support this isothermal infusion process and maintain acceptable resin properties. Therefore, resin development initiatives have designed anionic catalyzed epoxy systems capable of isothermal infusion and rapid cure at a temperature below 100 ˚C in one hour. High-performance aerospace properties are achieved after undergoing a freestanding post-cure. The resins facilitate faster, energy efficient production cycles by reducing the time and temperature required for cure and eliminating temperature ramps typically required of materials used in the aerospace industry. This work discusses several of the developed resin systems and the impact of varying composition on rheological, thermal, and mechanical properties. Carbon fiber composites were fabricated for one composition by resin transfer molding to demonstrate the potential of these isothermal, rapid cure systems for meeting industry needs.

resin transfer molding↗

How Optical and Electrical Properties of ITO Coated Willow Glass Affect Photonic Curing Outcome for Upscaling Perovskite Solar Cell Manufacturing

Indium tin oxide (ITO) coated Willow® glass is an excellent substrate for roll-to-roll manufacturing of perovskite solar cells (PSCs) but can have large variability in its optical and electrical properties. Photonic curing uses intense light pulses instead of heat to process materials and can facilitate faster processing speeds in roll-to-roll manufacturing to upscale the production of PSCs. Since the entire film stack can absorb light and contributes to the photonic curing outcome, the substrate materials’ properties play an integral role. Furthermore, we present the effect of ITO transmittance on the photonic curing of nickel nitrate sol-gel precursors into nickel oxide and consequently the performance of PSCs fabricated with only photonic curing and no thermal annealing. Unexpectedly, ITO samples processed by photonic curing show improved optical and electrical properties.

14 SOLAR ENERGY↗

Photonic Curing of Nickel Oxide Transport Layer and Perovskite Active Layer for Flexible Perovskite Solar Cells: A Path Towards High-Throughput Manufacturing

High-throughput roll-to-roll (R2R) manufacturing of perovskite solar cells (PSCs) is currently limited by thermal processes that take tens of minutes each, translating to impractically long annealing tools at high web speeds. In addition, PSCs are usually made with metal oxide transport layer materials that require high temperatures for thermal annealing. Here, we demonstrate the fabrication of PSCs using photonic curing, instead of thermal annealing, to convert NiO x directly from sol-gel precursors for hole transport layers and to crystallize methylammonium lead iodide (MAPbI 3 ) active layers on flexible Willow ® Glass substrates. Photonic curing uses short, intense pulses of light to process materials at a high speed, hence it is compatible with R2R manufacturing. We achieved power conversion efficiencies (PCEs) of 11.7% in forward-scan and 10.9% in reverse-scan for PSCs made with photonic cured NiO x and MAPbI 3 films. Furthermore, both NiO x and MAPbI 3 films could be processed with a single photonic curing pulse, with a web speed of 5.7 m/min, and still produce PCEs comparable to thermally annealed control samples. Based on the single-pulse photonic curing condition for each film, we project a web speed of 26 m/min, laying a pathway to high-throughput production of perovskite solar modules.

14 SOLAR ENERGY↗

Porosity Detection and Localization During Composite Cure Inside an Autoclave Using Ultrasonic Inspection

Composite materials offer unique benefits in aerospace applications such as increased strength-to-weight ratio and improved fatigue properties. They are increasingly being used in major commercial aircraft programs. However, current processing methods can lead to defects in composite parts, which must be detected using post-manufacturing inspection methods. Porosity (i.e., pores, voids) is a critical defect from the cure process that is detrimental to performance of the composite part. It is therefore necessary to understand and eliminate the formation of porosity defects. At NASA Langley Research Center, an in-situ cure monitoring system was developed to detect porosity defects as they form in real-time inside an autoclave. A capability to directly detect and localize porosity within a composite during cure did not exist before. This study is focused on an elevated-temperature ultrasonic inspection system to detect porosity defects in composites during autoclave cure. The ultrasonic inspection system operated inside an autoclave within an enclosure cooled by intermittent liquid nitrogen (LN_2) injections. A high-temperature, 2.25 MHz, transducer transmitted ultrasonic waves through the tool plate and into the composite part and measured the amplitude and time of flight of the reflected waves with a 1 mm × 1 mm step size/areal resolution. Porosity was observed via the ultrasonic reflections, which experienced increased attenuation in regions of high porosity. Distinct regions of increased porosity were present due to uneven pressure across the panel, which was driven by an intentional misfit between the flat caul plate and the tapered composite panel with ply drops. The results were validated by post-cure ultrasonic inspection and micrographs. The in-situ inspection system was able to successfully provide porosity detection and localization in the tapered ply-drop panel. The successful results indicate the promise of this system for future implementation in the manufacturing of composite structures for aerospace applications.

Composites↗

Latent Cure Epoxy Resins for Reliable Joints in Secondary-Bonded Composite Structures

In high-performance polymer matrix composite assemblies, adhesive bonding is generally superior to mechanical fastening in structural performance and manufacturing efficiency. However, adhesive bonds are susceptible to minute levels of contamination accumulated during assembly that can lead to unpredictable, weak bonds. Current methods of measuring bond strength are all destructive mechanical tests. To overcome these challenges, redundant load paths (e.g., mechanical fasteners) are often implemented in secondary-bonded, primary-structures, which can greatly reduce structural performance. This study investigated reformulated aerospace epoxy matrix resins with stoichiometric offset to inhibit cure of the matrix resin prior to assembly. Inhibited resins can reflow and mix across the joint interface, which eliminates the material discontinuity and forms a homogenous joint with reliable fracture properties. The goal of this study was to develop and demonstrate secondary composite assemblies that are mechanically and microscopically indistinguishable from a co-cured composite joint. This article describes the development of latent epoxy resins, the fabrication of test articles, and the mechanical properties measured from experimental joints compared with conventional, co-cured laminates. Methods of in-line quality control using and infrared spectroscopy and post-assembly forensics are also described. The final mode-II fracture toughness measured from precracked AERoBOND specimens was similar to that measured from co-cured laminates indicating that later cure epoxy materials could be a suitable replacement for secondary bonding.

Polymer-matrix composites (PMCs)↗

Impact of carbamate formation on the surface tension of epoxy‐amine curing systems

Abstract Epoxy‐amine reactive systems, including their surface tension, have been studied due to their use and importance in composites and adhesives in laboratory and industrial applications. Understanding how the system's surface tension changes during curing could help target applications for tailored composites. Using the Wilhelmy plate method, surface tensions for epoxy‐curing agent systems were investigated under different environments. While the epoxy exhibited an expected negative temperature coefficient of −0.096 mN/m/°C, the curing agent exhibited a positive temperature coefficient of 0.073 mN/m/°C, which is due to the curing agent reacting with atmospheric CO 2 to form carbamate through a zwitterion pathway and functional groups accumulating at the surface of the reacting systems. Carbamate formation results in a surface tension below that of the individual constituents in the epoxy‐amine curing agent system. Fourier transform infrared (FTIR) spectroscopy was used to verify in situ formation of carbamate, and by reducing the system's temperature, it was demonstrated that the system surface tension profiles displayed micellar surfactant‐like characteristics. FTIR was used to explore the difference in composition between the surface and the bulk, in particular carbamate formation at the surface, resulting in a lowering of the surface tension of reacting systems.

Shenk, Timothy M.↗

Chemical structure and curing dynamics of bisphenol S, PEEK™-like, and resveratrol phthalonitrile thermoset resins

This effort provides a multifaceted analysis of the structural changes and material dynamics of thermally driven softening and curing of three distinct phthalonitrile (PN) resins that cross-link into thermally stable and oxidation-resistant thermosets. Although this material system has yielded a large subset of fire-retardant composites that require facile processing and low-temperature curing, to date, insufficient information had been available on the fundamental processes that drive their softening and curing stages. Our approach conducted a complementary analysis the chemistry, monomer mobility, and rheology of three PN polymers in order to correlate the curing processes with corresponding structural and behavioral transformations of thermosets. Here, we focused on PNs with a bisphenol S backbone, a bisphenol A (PEEK™-like) backbone, and a resveratrol backbone. We relied on quasi-elastic neutron scattering (QENS) in order to analyze the in situ dynamics and self-diffusion properties of PN monomers, and to track changes in their mobilities during cross-linking and staging. Our analysis facilitates proper control over the staging and final curing of these resins and enables more efficient processing of these thermosets.

36 MATERIALS SCIENCE↗

Understanding curing dynamics of arylacetylene and phthalonitrile thermoset blends

Tetrakis(phenylethynyl)benzene (TPEB), a high char yield arylacetylene resin, was blended with a resorcinol-based PEEK™-like oligomeric phthalonitrile resin (Res). Here, we observed the influence of each polymer precursor on the structural changes and material dynamics of different mixtures of these resins during thermal curing to produce thermosets with high char retention. We provide insight to help understand fundamental processes that control and tune this complex thermally driven curing mechanism, which, to date, has not been well understood. We show that an equivalent blend of Res and TPEB mitigates the exothermic curing process and exhibits a low viscosity, which may facilitate processing of these thermosetting blends for composite manufacturing. To obtain a more comprehensive overview of the different dynamics of these polymers during curing, we correlated thermodynamic changes with rheology, materials characterization, and molecular dynamics derived from neutron scattering. Our efforts shed more light on the thermally driven chemical changes, physical transformation, and gelation dynamics that drive or accompany softening and curing of these two distinct crosslinking resin groups.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-time cure monitoring of fiber-reinforced polymer composites using infrared thermography and recursive Bayesian filtering

Despite the desirable characteristics of fiber-reinforced polymer (FRP) composites, their utilization in high volume production industries is limited by a lack of efficient manufacturing techniques. Monitoring the curing process of these composites can help with improving the quality and efficiency of the manufacturing process. This article discusses a method that uses Kalman-filter-based fusion of the information obtained from infrared thermography (surface temperature measurements) and a heat conduction model to estimate degrees of cure and internal temperatures of curing FRP composite parts in real time. The effectiveness of the methodology is demonstrated by successfully monitoring the curing of an FRP composite part in a laboratory experiment. Finally, the proposed methodology is a crucial step towards identifying anomalies in the curing process that negatively impact the quality of FRP composite parts.

36 MATERIALS SCIENCE↗

Effect of post cure time and temperature on the properties of two phenolic-fiber composites

Some effects of post-cure time and temperature on the physicomechanical properties of a phenolic-asbestos and a phenolic-glass composite are studied. The molding and post-curing procedures are discussed along with physical and mechanical test results. It is found that the specific gravity of the panels tested decreased slightly but the hardness always increased with post cure, and that the mechanical properties had different patterns of response to increasing post-cure time and temperature. For tensile properties, strength decreased, modulus increased, and elongation at break exhibited little change. In general, the phenolic-asbestos showed more positive response to post cure than did the phenolic-glass. Mold venting is found to impart better properties to the composites concerned.

Lucy, M. H.↗

Acoustic characterization of composite cure

The relationship between the time evolution of ultrasonic longitudinal velocities, measured in the course of the cure of 3501-6 neat and fiber-reinforced resin, and the time evolution of the degree of cure was studied. The resin samples were placed in a mold, one side of which was a graphite plate, while the rest was made of stainless steel. After placing the mold in a press and applying a single-cycle 5-MHz pulse to the transducer bonded to the outer side of the graphite plate, the echo resulting from the resin-graphite interface and the subsequent echoes from within the resin layer were recorded with a 200-MHz, 8-bit digitizer. The degree of cure was calculated from the acoustic response, using the relationships derived by Winfree and Parker (1986). The calculated degree of cure had the expected time dependence, and the agreement between the degree of cure measured for the neat resin and the prepreg was reasonable.

Parker, F. R.↗

Differential Curing In Fiber/Resin Laminates

Modified layup schedule counteracts tendency toward delamination. Improved manufacturing process resembles conventional process, except prepregs partially cured laid on mold in sequence in degree of partial cure decreases from mold side to bag side. Degree of partial cure of each layer at time of layup selected by controlling storage and partial-curing temperatures of prepreg according to Arrhenius equation for rate of gel of resin as function of temperature and time from moment of mixing. Differential advancement of cure in layers made large enough to offset effect of advance bag-side heating in oven or autoclave. Technique helps prevent entrapment of volatile materials during manufacturing of fiber/resin laminates.

Webster, Charles N.↗

Monitoring cure of composite resins using frequency dependent electromagnetic sensing techniques

A nondestructive in situ measurement technique has been developed for monitoring and measuring the cure processing properties of composite resins. Frequency dependent electromagnetic sensors (FDEMS) were used to directly measure resin viscosity during cure. The effects of the cure cycle and resin aging on the viscosity during cure were investigated using the sensor. Viscosity measurements obtained using the sensor are compared with the viscosities calculated by the Loos-Springer cure process model. Good overall agreement was obtained except for the aged resin samples.

Kranbuehl, D. E.↗

Nonintrusive method and apparatus for monitoring the cure of polymeric materials

The invention is a nonintrusive method of monitoring the cure of a polymeric material using an electromagnetic field to sense a change of resistance of the polymeric material in the electromagnetic field that occurs during curing. This change of resistance is used to vary the impedance of an alternating voltage power supply that produces the electromagnetic field and which change of impedance is measured periodically or continuously to monitor the cure of said polymeric material. The apparatus for practicing the method of this invention may include a nonintrusive sensing head providing an inner, electromagnetic core within an open ended outer pot formed of magnet material. The open end of the pot core is positioned from a selected area of the surface of a sheet of the polymeric material. An alternating voltage supply circuit includes an inductance coil around the electromagnetic core and capacitor connected in parallel with the inductance coil forms a resonant tank circuit when energized. The resulting change in resistance of the polymeric material opposite the open end, a function of the curing, is measured as a corresponding change in the impedance of the power supply circuit to thereby monitor the cure of the polymeric material in the selected area.

Johnston, David F.↗

Monitoring Fiber Stress During Curing of Single Fiber Glass- and Graphite-Epoxy Composites

The difference in thermal expansion characteristics of epoxy matrices and graphite fibers can produce significant residual stresses in the fibers during curing of composite materials. Tests on single fiber glass-epoxy and graphite-epoxy composite specimens were conducted in which the glass and graphite fibers were preloaded in tension, and the epoxy matrix was cast around the fibers. The fiber tension was monitored while the matrix was placed around the fiber and subjected to the temperature-time curing cycle. Two mechanisms responsible for producing stress in embedded fibers were identified as matrix thermal expansion and contraction and matrix cure shrinkage. A simple analysis based on the change in fiber tension during the curing cycle was conducted to estimate the produced stresses. Experimental results on single fiber glass- and graphite-epoxy composites show that the fiber was subjected to significant tensile stresses when the temperature was raised from the first to the second dwell period. When initial fiber pretension is about 60 percent of the fiber failure load, these curing-induced stresses can cause tensile fracture of the embedded fiber.

Madhukar, Madhu S.↗

[Methods Used for Monitoring Cure Reactions in Real-time in an Autoclave]

The goal of the research was to investigate methods for monitoring cure reactions in real-time in an autoclave. This is of particular importance to NASA Langley Research Center because polyimides were proposed for use in the High Speed Civil Transport (HSCT) program. Understanding the cure chemistry behind the polyimides would allow for intelligent processing of the composites made from their use. This work has led to two publications in peer-reviewed journals and a patent. The journal articles are listed as Appendix A which is on the instrument design of the research and Appendix B which is on the cure chemistry. Also, a patent has been awarded for the instrumental design developed under this grant which is given as Appendix C. There has been a significant amount of research directed at developing methods for monitoring cure reactions in real-time within the autoclave. The various research efforts can be categorized as methods providing either direct chemical bonding information or methods that provide indirect chemical bonding information. Methods falling into the latter category are fluorescence, dielectric loss, ultrasonic and similar type methods. Correlation of such measurements with the underlying chemistry is often quite difficult since these techniques do not allow monitoring of the curing chemistry which is ultimately responsible for material properties. Direct methods such as vibrational spectroscopy, however, can often be easily correlated with the underlying chemistry of a reaction. Such methods include Raman spectroscopy, mid-IR absorbance, and near-IR absorbance. With the recent advances in fiber-optics, these spectroscopic techniques can be applied to remote on-line monitoring.

Cooper, John B.↗