Global Event-identifier Module: A distributed digital approach to event-of-interest identification logic for physics experiments

The demands from current data acquisition systems are to acquire data from a large number of detectors (or signals) while providing a high throughput. This can be achieved by having some preprocessing capability in the data acquisition system so that it can identify the events of interest. Precise selection of events with minimal time for identification and preprocessing is an experimental challenge. To address this challenge, we have developed a ''Global Event-identifier Module'' (GEM) on the CAMAC platform, which can flexibly adapt to the experimental requirements and validate an event with minimal time. GEM is a single width CAMAC module capable of operating in a ''distributed'' data acquisition environment where multiple CAMAC crates (each with one GEM module) can be used to collect synchronized data from all the crates. Event-of-interest decision can be made on signals connected to different crates. Inter-GEM communication is via the ubiquitous ethernet (unshielded twisted pair, CAT5) cable. The event of interest is decided within 32 ns (excluding cable delay). Implementation is accomplished using field programmable gate array which enables greater flexibility for algorithm modifications and updates without hardware changes. GEM supports unified, distributed, and multi-strobe data acquisition, enabling higher throughput, with data collection from a large number of signals by selective reads of events of interest as determined by the experimenter while providing timestamped data of each event.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LCP Identification Method based on Pulse Shape Analysis

An improved LCP identification method based on Pulse shape analyses has been designed, the module 'Dual Pulse-Shape Analyzer' has been built and tested and resent experimental results of instrument utilizing have been presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test results of an ITER relevant FPGA when irradiated with neutrons

The data acquisition and control instrumentation cubicles room of the ITER tokamak will be irradiated with neutrons during the fusion reactor operation. A Virtex-6 FPGA from Xilinx (XC6VLX365T-1FFG1156C) is used on the ATCA-IO-PROCESSOR board, included in the ITER Catalog of I and C products - Fast Controllers. The Virtex-6 is a re-programmable logic device where the configuration is stored in Static RAM (SRAM), functional data stored in dedicated Block RAM (BRAM) and functional state logic in Flip-Flops. Single Event Upsets (SEU) due to the ionizing radiation of neutrons causes soft errors, unintended changes (bit-flips) to the values stored in state elements of the FPGA. The SEU monitoring and soft errors repairing, when possible, were explored in this work. An FPGA built-in Soft Error Mitigation (SEM) controller detects and corrects soft errors in the FPGA configuration memory. Novel SEU sensors with Error Correction Code (ECC) detect and repair the BRAM memories. Proper management of SEU can increase reliability and availability of control instrumentation hardware for nuclear applications. The results of the tests performed using the SEM controller and the BRAM SEU sensors are presented for a Virtex-6 FPGA (XC6VLX240T-1FFG1156C) when irradiated with neutrons from the Portuguese Research Reactor (RPI), a 1 MW nuclear fission reactor operated by IST in the neighborhood of Lisbon. Results show that the proposed SEU mitigation technique is able to repair the majority of the detected SEU errors in the configuration and BRAM memories. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive Noise Analysis for Advanced Tamper Indication. End of Year Report 2015

Idaho National Laboratory (INL) is part of a multi-lab project assessing front-end electronics for unattended measurement (FEUM) being developed for the International Atomic Energy Agency (IAEA) unattended systems. The FEUM development activity provides an opportunity to address tampering detection between FEUM and the detector, signal integrity from FEUM to the data acquisition systems, and data validity – long-standing challenges for the IAEA. This report summarizes the INL activities in Fiscal Year (FY) 2015 to characterize and test passive noise analysis as a potential tamper-indicating approach for implementation into FEUM or as a stand-alone method. The project’s primary objectives in FY-15 were to (1) determine detectable tamper scenarios using four pre-amplifier/detector systems, (2) perform tests of tampering scenarios with three common cable types used by the IAEA, (3) separate radio-frequency-induced events from inherent effect by means of an anechoic chamber, and (4) perform tests at an industrial facility. General conclusions were reached in several areas.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A Hydrazine Leak Sensor Based on Chemically Reactive Thermistors

Leaks in the hydrazine supply system of the Shuttle APU can result in hydrazine ignition and fire in the aft compartment of the Shuttle. Indication of the location of a leak could provide valuable information required for operational decisions. WSTF has developed a small, single use sensor for detection of hydrazine leaks. The sensor is composed of a thermistor bead coated with copper(II) oxide (CuO) dispersed in a clay or alumina binder. The CuO-coated thermistor is one of a pair of closely located thermistors, the other being a reference. On exposure to hydrazine the CuO reacts exothermically with the hydrazine and increases the temperature of the coated-thermistor by several degrees. The temperature rise is sensed by a resistive bridge circuit and an alarm registered by data acquisition software. Responses of this sensor to humidity changes, hydrazine concentration, binder characteristics, distance from a liquid leak, and ambient pressure levels as well as application of this sensor concept to other fluids are presented.

Davis, Dennis D.↗

NASA Tech Briefs, September 1996

Topics: Data Acquisition and Analysis; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Books and Reports.

Source record↗

NASA Tech Briefs, September 1997

Topics include: Data Acquisition and Analysis; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Software; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences.

Source record↗

NASA Tech Briefs, July 1993

Topics include: Data Acquisition and Analysis: Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery; Fabrication Technology; Mathematics and Information Sciences; Life Sciences.

Source record↗

Recent Developments in Chemically Reactive Sensors for Propellants

Propellant system leaks can pose a significant hazard in aerospace operations. For example, a leak in the hydrazine supply system of the shuttle auxiliary power unit (APU) has resulted in hydrazine ignition and fire in the aft compartment of the shuttle. Sensors indicating the location of a leak could provide valuable information required for operational decisions. WSTF has developed a small, single-use sensor for detection of propellant leaks. The sensor is composed of a thermistor bead coated with a substance which is chemically reactive with the propellant. The reactive thermistor is one of a pair of closely located thermistors, the other being a reference. On exposure to the propellant, the reactive coating responds exothermically to it and increases the temperature of the coated-thermistor by several degrees. The temperature rise is sensed by a resistive bridge circuit, and an alarm is registered by data acquisition software. The concept is general and has been applied to sensors for hydrazine, monomethylhydrazine, unsym-dimethylhydrazine, ammonia, hydrogen peroxide, ethanol, and dinitrogen tetroxide. Responses of these sensors to humidity, propellant concentration, distance from the liquid leak, and ambient pressure levels arc presented. A multi-use sensor has also been developed for hydrazine based on its catalytic reactivity with noble metals.

Davis, Dennis D.↗

NASA Tech Briefs, January 1999

Topics include: special coverage sections on sensors and data acquisition and sections on electronic components and circuits, electronic software, materials, mechanics, bio-medical physical sciences, book and reports, and a special section of Photonics Tech Briefs.

Source record↗

Readout system of TPC/MPD NICA project

The time-projection chamber (TPC) is the main tracking detector in the MPD/NICA. The information on charge-particle tracks in the TPC is registered by the MWPG with cathode pad readout. The frontend electronics (FEE) are developed with use of modern technologies such as application specific integrated circuits (ASIC), field-programmable gate arrays (FPGA), and data transfer to a concentrator via a fast optical interface. The main parameters of the FEE are as follows: total number of channels, ∼95 000; data stream from the whole TPC, 5 GB/s; low power consumption, less than 100 mW/ch; signal to noise ratio (S/N), 30; equivalent noise charge (ENC), <1000e{sup –} (C{sub in} = 10–20 pF); and zero suppression (pad signal rejection ∼90%). The article presents the status of the readout chamber construction and the data acquisition system. The results of testing FEE prototypes are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Energy Muon Beam Diagnostics - Scintillating Fiber Profile Monitor (SFPM)

The MeV Test Area (MTA) houses the 400 MeV H^− Beam at the end of the Linac and a secondary beamline of muons and pions created from hitting a Tungsten target. The MTA is in the Irradiation Test Area (ITA), where experiments involve studying the effects of radiation on materials in the MTA beam. There is a need for a retractable detector to monitor the secondary beam s intensity and coarse profile. The SFPM was chosen when considering factors like ability to measure low rates and handle high intensities. The plan was to test different scintillating fibers & Silicon Photomultiplier (SiPM) models to figure out which combination gives the best signals, and gain familiarity with the detector assembly, operation, and data acquisition software before using with final detectors in beamline. The SiPM circuit has been tested with a LED pulser successfully. The immediate steps that follow will be to set the SiPM up on the monitor with three different types of optical fibers, use the Caen software to configure the best mode of data acquisition, and proceed with an offline source test using Strontium-90. Once the most efficient measurement method is clear, they will be ready for use in the beamline.

Leith, Justin↗

Low Energy Muon Beam Diagnostics: Scintillating Fiber Profile Monitor

The MeV Test Area (MTA) houses the 400 MeV H- Beam at the end of the Linac and a secondary beamline of muons and pions created from hitting a Tungsten target. The MTA is in the Irradiation Test Area (ITA), where experiments involve studying the effects of radiation on materials in the MTA beam. There is a need for a retractable detector to monitor the secondary beam’s intensity and coarse profile. The SFPM was chosen when considering factors like ability to measure low rates and handle high intensities. The plan was to test different scintillating fibers & Silicon Photomultiplier (SiPM) models to figure out which combination gives the best signals, and gain familiarity with the detector assembly, operation, and data acquisition software before using with final detectors in beamline. The SiPM circuit has been tested with a LED pulser successfully. The immediate steps that follow will be to set the SiPM up on the monitor with three different types of optical fibers, use the Caen software to configure the best mode of data acquisition, and proceed with an offline source test using Strontium-90. Once the most efficient measurement method is clear, they will be ready for use in the beamline.

Leith, Justin↗

Operation of a New COTS Crystal Oscillator - CXOMHT over a Wide Temperature Range

Crystal oscillators are extensively used in electronic circuits to provide timing or clocking signals in data acquisition, communications links, and control systems, to name a few. They are affordable, small in size, and reliable. Because of the inherent characteristics of the crystal, the oscillator usually exhibits extreme accuracy in its output frequency within the intrinsic crystal stability. Stability of the frequency could be affected under varying load levels or other operational conditions. Temperature is one of those important factors that influence the frequency stability of an oscillator; as it does to the functionality of other electronic components. Electronics designed for use in NASA deep space and planetary exploration missions are expected to be exposed to extreme temperatures and thermal cycling over a wide range. Thus, it is important to design and develop circuits that are able to operate efficiently and reliably under in these harsh temperature environments. Most of the commercial-off-the-shelf (COTS) devices are very limited in terms of their specified operational temperature while very few custom-made commercial and military-grade parts have the ability to operate in a slightly wider range of temperature than those of the COTS parts. These parts are usually designed for operation under one temperature extreme, i.e. hot or cold, and do not address the wide swing in the operational temperature, which is typical of the space environment. For safe and successful space missions, electronic systems must therefore be designed not only to withstand the extreme temperature exposure but also to operate efficiently and reliably. This report presents the results obtained on the evaluation of a new COTS crystal oscillator under extreme temperatures.

Patterson, Richard↗

Recent results from the InP homojunction cell module on the LIPS III spacecraft

The flight performance of the NASA Lewis Research Center's indium phosphide homojunction cell module on the LIPs III spacecraft is presented. Four n+-p diffused junction cells, an early product of an InP development program, were flown. The voltage range of the data prohibits determination of the open-circuit voltage or the maximum power point. However, analysis of the 32 months of short-circuit current data reveals a slight increase, not the 4 percent decrease expected from radiation tolerance studies. This increase may be due to continual cleaning of possible prelaunch dust contamination or changes in data acquisition system calibration. For all cells, the average short-circuit current remains below prelaunch values.

Brinker, David J.↗

Juvenile Salmon Acoustic Telemetry System Transmitter Downsize Assessment

At the request of the U.S. Army Corps of Engineers, Portland District, researchers from Pacific Northwest National Laboratory investigated the use of an application-specific integrated circuit (ASIC) to reduce the weight and volume of Juvenile Salmon Acoustic Telemetry System (JSATS) transmitters while retaining current functionality. Review of the design of current JSATS transmitters identified components that could be replaced by an ASIC while retaining the function of the current transmitter and offering opportunities to extend function if desired. ASIC design alternatives were identified that could meet transmitter weight and volume targets of 200 mg and 100 mm3. If alternatives to the cylindrical batteries used in current JSATS transmitters can be identified, it could be possible to implant ASIC-based JSATS transmitters by injection rather than surgery. Using criteria for the size of fish suitable for surgical implantation of current JSATS transmitters, it was concluded that fish as small as 70 mm in length could be implanted with an ASIC-based transmitter, particularly if implantation by injection became feasible.

47 OTHER INSTRUMENTATION↗

A Full-length Quench Antenna for MQXFA Production Series Quadrupole Magnet Testing

The MQXFA production series quadrupoles being built for the Hi-Lumi (HL) LHC upgrade by the US Accelerator Upgrade Project (US-HL-LHC AUP) will have very limited instrumentation for characterizing quench events that occur during magnet training and performance validation testing. In order to understand the origin of the quenches, and whether they have some implication for ongoing magnet fabrication, it was decided to build a full-length Quench Antenna (QA) with axial resolution of 50mm to be employed during cold testing in the anticryostat used for magnetic measurements. The goal is to have fineresolution, full-length coverage detection of quench events axially, as well as to have azimuthal resolution on the order of the cable width (about 1 degree for the cross-section), in a device that can be used both for vertical and horizontal testing. To achieve this, a 5m long QA with 128 channels of high-speed data acquisition has been designed and fabricated. The cylindrical antenna features an array of 12 full-length, dipole- and quadrupole-bucked coils positioned radially in the QA interior for azimuthal localization, and over 100 individual channels of short, high-sensitivity, antennas etched as flexible PCB circuits (which also buck dipole and quadrupole fields) wrapped circumferentially on the cylinder exterior in steps of 50mm along the magnet length for axial detection. This report discusses the design, construction and analysis of the MQXFA QA, and first results from using the antenna during quench testing in the production magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗